HYDROQUIP BIS-15-120-GF Baptistery Immersion Heater System Instructions
- June 13, 2024
- HYDROQUIP
Table of Contents
HYDROQUIP BIS-15-120-GF Baptistery Immersion Heater
MODEL AND DESCRIPTION
Model | Description |
---|---|
BIS-15-120-GF | 1.5 kW, 120V – with GFCI Cord and Float |
BIS-15-120-G | 1.5 kW, 120V – with GFCI Cord, No Float |
BIS-60-240-GF | 6.0 kW, 240V – with GFCI Cord and Float |
BIS-60-240-B | 6.0 kW, 240V – No Cord, No GFCI, No Float |
BIS-60-240-FP | 6.0 kW, 240V – with Cord and Float, No GFCI |
BIS-60-240-G | 6.0 kW, 240V – with GFCI Cord*, No Float |
BIS-60-240-P | 6.0 kW, 240V – with Cord, No GFCI, No Float |
SPECIFICATIONS
Thermostat:
Preset to 90°F, Adjustable Range 55° to 104°F (+3°)
High Limit:
Cut off @118°F (+3°)
Wattage:
1.5kW / 6.0kW 1500 / 6000 Watts
Construction:
Incoloy
Electrical Requirements:
Model: | BIS-60-240-XX | BIS-15-120-XX |
---|---|---|
Voltage: | 208-240V(1-phase) | 110-120V |
Plug Type: | Nema 6-30P* | Nema 5-15* |
Amps: | 25A @ 240V | 13A @ 120V |
29A @ 208V | 14A @ 110V | |
Breaker Size: | 40A | 20A |
Exclusive Heater Water Level Safety Switch
Heat Rise Chart
Kilowatts:
Amps: Voltage:
| 1.5kW
12.5
120V
| 6.0kW
25
240V
---|---|---
Gallons| Temperature Rise
in 1 Hour (F)
100| 7.72| 24.66
200| 3.61| 12.33
300| 2.24| 8.22
400| 1.56| 6.18
500| 1.14| 4.92
600| 0.87| 4.11
700| 0.67| 3.51
800| 0.53| 3.09
900| 0.41| 2.73
1000| 0.32| 2.46
Read User Manual Online (PDF format)