BreathSafe 794AC Haul Truck Owner’s Manual

June 1, 2024
BreathSafe

Parts and Service Manual
CATERPILLAR
794AC HAUL TRUCK

HEPA H14 Variable Speed Pressuriser | INPRESS TS Cabin Display with CO2 Sensor | HEPA Return Air Filter

INSTALLATION

INSTALLATION OVERVIEW

Manufacturer| CATERPILLAR
Type| Haul Truck
Model| 794AC
Cabin Pressure Max|
Set Auto Cabin Pressure|

BreathSafe 794AC Haul Truck -

WARNING
THE PRESSURISATION SYSTEM DESCRIBED IN THIS MANUAL HAS THE FOLLOWING AREAS WHICH MAY BE DANGEROUS IF NOT TREATED WITH GREAT CARE.
QUALIFIED STAFF MUST WEAR THE CORRECT PERSONAL PROTECTIVE EQUIPMENT WHEN CLEANING AND SERVICING THIS UNIT DUE TO DUST AND FIBRES WHICH MAY BE CAUGHT BY THE STAGES OF AIR FILTRATION DURING NORMAL UNIT OPERATION.
THE ELECTRICAL POWER SYSTEM IS SUPPLIED BY 12V DC OR 24V DC AND NO WORK SHOULD BE CARRIED OUT ON THE PRESSURISER SYSTEM WITHOUT THE CORRECT SAFE WORK PROCEDURES AND ELECTRICAL SAFETY MEASURES BEING TAKEN, AND ALL RELEVANT CIRCUIT BREAKER OPENED TO ISOLATE THE CIRCUIT.
THE AIR FILTRATION SYSTEM MAY HAVE SEVERAL TYPES OF HIGH-SPEED ROTATING EQUIPMENT INSTALLED WITH VERY SHARP EDGES. ENSURE ALL SAFETY GUARD ARE IN PLACE WHILE THE SYSTEM IS RUNNING.
Please be aware that HEPA filters cannot be cleaned and must be replaced at the end of their lifecycle or if filter media has been damaged.

SAFETY

Particulate Behaviour
This is the length of time it takes for a particle to drop from a height of 1.5m in STILL air.

BreathSafe 794AC Haul Truck - icon1

Warehouses and workshops do not have still air, so hazardous airborne particulates may remain in air for longer, increasing chance for workers to breathe in dust. Ensure PPE is worn when installing this system.

BreathSafe 794AC Haul Truck - icon2

Maintenance Schedule
The following tables show our suggested maintenance schedule for all units. Please note that site conditions may alter this.
Excludes high corrosion environments.
Data download is required to claim the 3-year warranty on Brushless Blower Motor.
**Inspect every 500 Hours and replace when filter is full***

Component / System Action Required
Turbo Pre-cleaner Check operation of the Turbo Pre- Cleaner.
Pressuriser Blower Ensure blower is operational.
HEPA Primary Filter p/n: 500000 Inspect filter capacity indicator.

Replace HEPA filter when 80% or greater. Vacuum out housing before replacing the filter elements.
HEPA Return Air Filter P/N:  500008| Vacuum inside cabin floor before replacing filter.
Filter Frame Assembly, Mounts, Seals and Filter Housing| Check door seals, all bolts, screws, and all mounts are secure.
Check the filter canister & ensure it is correctly fitted.
Check latches are operational and in good order.
Replace / Re-tension fixtures and fittings required.

**15,000 Hours / 36 months***

Component / System Action Required
500 Hour Inspection All 500-hour inspection actions.
Pressuriser’s Blower 200002 Replace BRUSHLESS Pressuriser blower.

CRITICAL PARTS & MAINTENANCE SCHEDULE

Critical Parts

Item| Part Number| Qty.| Description| Service Interval
1| 500000| 1| Fresh Air HEPA H14 Filter (Tested as per

EN1822)

| 1000* Hours (>80%

fan capacity)

2| 500008| 1| HEPA Return Air Filter| 500* Hours
3| 200002| 1| Brushless Blower Motor – 24V| 15,000 Hours
4| 200027| 1| BreatheSafe Digital Display – Data Recorder (INPRESS TS)|

*Filter service hours are subject to cab sealing efficiency, site conditions and correct system use.

**Suggested Schedule Servicing***

The filter is serviceable if the motor capacity is between 10% & 80%. We recommend that the filter is changed if the capacity is over 80%.
*Site dependent

OPERATOR GUIDE

OPERATORS CHECKLIST

PRE-START
1.| Visually inspect the BreatheSafe system for any damage.
2.| Visually inspect the cabin for any damage to doors, windows, seals.
3.| Please remove dust & debris from shoes and clothes before entering the cabin.
4.| Ensure door(s) and windows are closed correctly.
5.| Start engine and turn HVAC on to speed 2 (medium speed).
6.| After fixed speed delay, the BreatheSafe display will show 50 Pascals or pre-set value.
The system is working correctly when the pascal value is green. > > There is no further action required < <

NORMAL OPERATING CONDITION
Cab Air Conditioning
BreatheSafe recommends OEM air conditioning fan is set at mid speed or greater to circulate air around the breathing zone and minimise CO₂.
Acceptable operating range for BreatheSafe fan 10-80%. >80% recommend maintenance.

ALERTS

Fixed Fan Start Delay
• Allows the operator to carry out pre-start checks – limiting at 30% fan speed, press the red text to disable.
CO₂ Level Alert (if equipped)
•  Ensure air conditioning fan is set at mid speed or greater to circulate air and minimise CO₂.
Low Pressure Alarm
• Cabin is not maintaining positive pressure – check doors and windows are closed correctly.
• Refer to maintenance department to check filters and cabin sealing. Ensure filters are serviceable.
Check Filter

• Reminder to inspect or replace filter. Service hour meter requires re-set.
• Refer to maintenance department.

Specifications High-Capacity HEPA Pressuriser

Blower : Brushless Blower P/N 200002.
Protection : Locked Rotor Protection (Sub Zero Environments) Under Voltage,

Under/Over Current & Over Temperature.
Voltage| : 24VDC.
Current Draw| : 11 amps (peak). *Note: Motor has slow start to stop excessive in-rush current.
Air Flow| : Up to 30-300 m³ /h or 50-215 CFM.
Pre-cleaner| : Integrated VLR (Very Low Restriction). Turbo Pre-Cleaner.
Filter Element| : BreatheSafe HEPA Primary Filter (H14=99.99% MPPS) TESTED AS PER EN1822 – P/N 500000.
Plugs & Fittings| : Mining Spec. Deutsch electrical plugs as standard.
Construction| : High strength composite construction.
Serviceability| : Easy access HEPA filter with twist-lock (TL) dust cap single assembly.
Mounting| : Heavy Duty adjustable mounting brackets.
Design| : Fully designed in SolidWorks 3D CAD & Ansys Engineering Simulation Software.
FEA Testing| : Critical components FEA (Finite Element Analyst) tested in Solid Works Simulation.
CFD Testing| : CFD (Computational Fluid Dynamics) simulations in Flow Works
to ensure optimum air flow through the system.

SPECIFICATIONS HIGH-CAPACITY HEPA PRESSURISER

List of Abbreviations

DH| Dual HEPA
DHPR| Dual HEPA Powered Recirculation
DHAC| Dual HEPA Activated Carbon
DHACPR| Dual HEPA Activated Carbon Powered Recirculation
CPM| Cabin Pressure Monitor
CPU| Central Processing Unit
DB| Decibel Sensor
DPM| Diesel Particulate Matter
GAS| Gas Sensor
HEPA| High-Efficiency Particulate Air Filter
HPAFU| High Pressure Air Filtration Unit
HRAF| HEPA Return Air Filter
HVAC| Heating Ventilation and Air Conditioning
MAF| Mass Air Flow
OEM| Original Equipment Manufacturer
PM| Particulate Mass
RH| Relative Humidity
TEMP| Temperature
TS| Touch screen
UI| User Interface
VMS| Vehicle Monitoring System
VS| Vibration Sensor
OGSP| OnGuard Sensor Pod
CO2s| CO2 Sensor INPRESS TS
Item No.| Qty.| Description| Part No.
---|---|---|---
1| 1| Pre-cleaner Hood & Rotor Assy| 200004
2| 4| Pre-cleaner Injector Ring| 200005
3| 1| TL Fan Blade (inc. in #7)| 200006
4| 1| TL Nose Cone / Pre-cleaner| 200007
5| 1| TL Motor Housing| 200008
6| 1| TL Filter Housing| 200009
7| 1| 24v DC Brushless VSD Motor & TL Fan Blade| 200002
8| 1| O Ring Seal Kit 2 Parts| 200010
9| 1| Included in 8| 200011
10| 1| Wiring Sleeve| 200012
11| 1| HEPA H14 Filter| 500000
12| 3| M6 Nyloc Nut| 300218 (M6NYL)
13| 3| M6 x 55mm Hex Bolt| 300982 (M655B)
14| 4| M8 x 190 Hex Bolt| 301136 (M8190B)
15| 8| M8 x 22mm O/D HD Washer| 300230 (M8222HTW)
16| 4| M8 Nyloc Nut| 300249 (M8NYL)
17| 5| M4 x 75mm Pan Head Phillips Screw| 300162 (M475PBH)

PARTS LIST – TL4 24V DC PRESSURISER UNIT
PRESSURISER ASSEMBLY No: 200000

BreathSafe 794AC Haul Truck - CATERPILLAR

Item No.| Part No.| Rev| Description| Qty| Colour| Category
---|---|---|---|---|---|---
1| 100275A01| 1| Pressuriser Module| 1| Satin Black MX88-124| Module
2| 100275P01| 0| Pipework Module| 1| Satin Black MX88-124| Module
3| 100275F01| 1| Fresh Air Module| 1| Satin Black MX88-124| Module
4| 100275R01| 1| Return Air Module| 1| Satin Black MX88-124| Module
5| 100275M01| 1| Monitor Mount Module| 1| Satin Black MX88-124| Module

Kit Part Number: 700362

PARTS LIST GA

COMPLETE ASSEMBLY No: 700362

BreathSafe 794AC Haul Truck - CATERPILLAR1

Item No.| Part No.| Rev| Description| Qty| Material| Thickness| Colour| Category
---|---|---|---|---|---|---|---|---
1| 10027A02| 1| TL Mount Plate Assembly| 1| –| –| Satin Black MX88-124| Weld Assy
2| 250007| []| TL Mount Brkt 56.5mm| 1| Mild Steel| 3| (As Req’d)| –
3| 250055| [
]| TL Side Mount WC Cover RH| 1| –| –| (As Req’d)| –
4| 200000| [*]| HPAFU 24V DC VSD TL4| 1| N/A| –| –| –

PARTS LIST – PRESSURISER MODULE

BreathSafe 794AC Haul Truck - CATERPILLAR2

Item No.| Part No.| Rev| Description| Qty| Material| Thickness| Colour| Category
---|---|---|---|---|---|---|---|---
1| 200307| –| 3” x 90* Elb Long Drop Sil| 1| Silicone| –| –| Pipework
2| 300388-0140| –| 76.3 x 1.6 @1400mm| 1| Stainless Steel Tube| 3.0”ODx1.6W/T| (Per Assy Colour)| –
3| 300848| N/A| 3” Cobra Neck| 1| –| –| –| Hardware
4| 300001| –| 65-89mm Hose Clamp| 4| Zinc Plated Steel| –| –| Hardware

PARTS LIST – FRESH AIR MODULE

BreathSafe 794AC Haul Truck - CATERPILLAR3

Item No.| Part No.| Rev| Description| Qty| Colour| Category
---|---|---|---|---|---|---
1| 100275F02| 1| Fresh Air Box with Spigot| 1| Satin Black MX88-124| Weld Assy
2| 100275F03| 0| Fresh Air Door Assembly| 1| Satin Black MX88-124| Weld Assy

PARTS LIST – RETURN AIR MODULE

BreathSafe 794AC Haul Truck - PARTS LIST

Item No.| Part No.| Rev| Description| Qty| Colour| Category
---|---|---|---|---|---|---
1| 100275R02| 0| RAF Frame Assy| 1| Satin Black MX88-124| Weld Assy
2| 100276R03| 0| RAF Plenum Assy| 1| Satin Black MX88-124| Weld Assy
3| 500008| [*]| HEPA Filter 225x175x51| 1| –| Stock Item
4| M6 OEM| –| M6 OEM Scallop Knob| 2| –| Hardware

PARTS LIST – RETURN AIR MODULE

BreathSafe 794AC Haul Truck - PARTS LIST1

Item No.| Part No.| Rev| Description| Qty| Colour| Category
---|---|---|---|---|---|---
1| 250101| [*]| STD Large Monitor Box| 1| –| Stock Item
2| 200027| N/A| INPRESS TS Controller CO2 Sensor| 1| –| Stock Item
3| 200031| N/A| CO2 Sensor Suit 200027| 1| –| Stock Item

PARTS LIST – MONITOR MOUNT

BreathSafe 794AC Haul Truck - PARTS LIST2

Display Key Features

  • Digital cabin pressure monitoring system
  • Automatic cabin pressure control
  • Intelligent fan speed output
  • Data logger
  • Alarm for low-pressure (RS20)
  • Light sensor for automatic dimming of the screen

BreathSafe 794AC Haul Truck - Display Key Features

TECHNICAL DETAILS

CO2 Sensor

  • CO2 Sensor Type is NDIR (Non-Dispersive Infrared)
  • Sample Rate is every 2 seconds
  • 12-30V DC Operating Voltage
  • Automatic Altitude Compensation
  • Alarm Set points are adjustable
  • No setup required

Connections: 200027

Item Destination
1 PIPE A – AMBIENT PRESSURE – OUTSIDE
2 PIPE B – POSITIVE PRESSURE – INSIDE
3 RJ45 CONNECTOR – CO2 SENSOR
4 OVERRIDE TOGGLE SW = MAX SPEED
Item Destination
1 12/24 VOLT POSITIVE SUPPLY
2 CAN H OPTION
3 CAN L OPTION
4 SERIAL TRANSMIT RS232
5 MOTOR CONTROL VOLTS OUT
6 ALARM + OUTPUT
7 TEMP SENSOR
8 NO CONNECTION
9 SERIAL RECEIVE RS232
10 DOOR INPUT (+)
11 WINDOW INPUT (+)
12 0V NEGATIVE GROUND

Wiring Diagram

BreathSafe 794AC Haul Truck - Wiring Diagram

  • Do not handle until MSDS & all safety precautions have been read and understood. Use personal protective equipment as required.
    Before use, carefully read the product label. Safe work practices are advised to avoid eye or skin contact and inhalation. Observe good personal hygiene, including washing hands before eating. Prohibit eating, drinking, and smoking in contaminated areas. Avoid inhalation. Mechanical extraction ventilation is recommended when the removal of atmospheric contaminants is required. Maintain dust / fume levels below the recommended exposure standard. For smalamounts, absorb with sand, vermiculite or similar and dispose of at an approved landfill site.

WARNING

For Professional Use Only – keep out of reach of children.
Do not ignite near or around flammable materials.
Use only in well-ventilated areas, outdoors, and/or with proper respiratory protection.
Persons with respiratory sensitivity should avoid exposure to any smoke.
Concentrated smoke may cause severe burns to the skin, eyes, or respiratory system.
Improper use may result in sufficient inhalation of smoke to cause respiratory tract irritation and lung damage.
Harmful if swallowed.

DANGER
Use only as directed. Do not handle until all safety precautions, including Safety Data Sheet, have been read and understood. The product contains hexachloroethane. Wear protective clothing. If exposed or concerned, get medical advice. Store in a cool, dry, secure location. KEEP OUT OF REACH OF CHILDREN. Dispose of contents/container per location regulations. When used as directed, exposure should be limited and usually poses no hazard because the hexachloroethane is consumed inside the tube as smoke is produced.

Directions: (Smoke Bomb)

1.| Ensure other workers in close proximity are informed of use. Place on a non-combustible container, away from flammable materials.
2.| Place at Blower intake, or upwind of target area, or near centre of space.
3.| Orient “Smoke Issues Here” toward air stream, away from surfaces. Place candle on a flame / heat resistance plate – if not it will melt into the plastic surface.
4.| Ensure smoke will not create any hazard where it is anticipated to go.
5.| Ignite emitter inside the cabin using site approved device i.e., solder torch or ‘lighter’ and conduct smoke test.
6.| Do not touch or hold smoke generator after ignition – item becomes very hot & remains hot after use.
Smoke Emitter Cabin Pressure Leak Test

1.| The pressuriser system is switched on (TEST MODE).
2.| Hold the smoke emitter angled down.
3.| Ignite emitter using site approved ignitor i.e., solder torch or ‘lighter’.
4.| When the product ignites, remove the lighter.
5.| If the product flames up, blow out the flame.
6.| Place the emitter in a non-flammable container and place it inside the cabin at floor level and close the door/windows.
7.| Observe smoke leaks to indicate worn-out or broken seal locations. Check leakage points outside the cabin.
8.| Do not come into contact with or inhale smoke haze.
9.| Wait until the smoke haze completely disperses before re-entering the cabin. Open door to allow sufficient ventilation of smoke prior to entering cabin.

SMOKE EMITTER CABIN PRESSURE LEAK TEST
Link to MSDS: SMOKE GENERATOR TQ7621AT30S.pdf

Personal Protective Equipment (PPE)

| Safety glasses must be worn at all times.
| Sturdy footwear with rubber soles must be worn.
| Respiratory protection devices may be required.
| Gloves may be worn.
Pre-operational Safety Checks
| Locate and ensure you are familiar with all machine operations and controls.
| Check work area and walkways to ensure no slip/trip hazards are present.
| Ensure the work area is clean and clear of any flammable material & fire extinguish device is present.
| Operational Safety Checks
---|---
| Ensure the machine is correctly isolated / immobilized.
| Ensure other persons do not inhale smoke haze.
| Take care and do not place a lit emitter close to a flammable surface.
Ending Operations and Cleaning Up

| Leave the work area in a safe, clean, and tidy state.
Potential Hazards

| Falls
| Fumes
| Fire
| May cause cancer
Exposure is highly unlikely when the product is used as directed. Direct contact with the product does not occur.
Don’t

| Do not use if an open flame is forbidden.
| Never leave the emitter [cabin test] unattended.

*This SWP does not necessarily cover all possible hazards associated with this equipment and should be used in conjunction with other references. It is designed as a guide to be used to compliment training and as a reminder to users prior to equipment use.

CABIN SEALING TEST PROCEDURE

Cabin Sealing Efficiency Test Procedure

1| Start Engine – Pressuriser System is ON
2| Ensure all windows & door(s) are CLOSED correctly (no cabin pressure leaks)
NOTE: for a new cabin with effective seals, you may need to open a window slightly before closing the door to bleed the static cabin air pressure outwards. Once door is fully closed then close windows to begin testing.
3| Enter the Settings menu via the touch screen button.
4| Select and press the System Check button to go to System Test – Max Fan.
5| Record / photograph the maximum cabin pressure achieved.

BreathSafe 794AC Haul Truck - Press Settings

Commissioning Procedures

Follow each step of the installation guide that was supplied with the BreatheSafe kit.
Cabin sealing is an integral part of RS20 & ISO 23875; you must ensure that cabin seals are adequate for maintaining positive pressure. In addition, the site (end- user) must have the correct procedure(s) for servicing OPERATOR enclosure seals in a proactive manner rather than reactive. Items such as door and window seals must be in good working order or new seals FITTED before the BreatheSafe system installation.
Touch-screen cabin pressure display/controller Part# 200027:
*System Check Function: enter the Settings menu option and select “System Check – Set Max.” The minimum BreatheSafe requirement for cabin sealing efficiency is 250 pascals; if this result is not met, it is essential to re-examine and find pressure leaks of the enclosure and apply new sealing measures.
Submission for commissioning procedure as per the diagram below:

BreathSafe 794AC Haul Truck - Commissioning Procedures

The commissioning images required are:

  • ID plate / Machine Serial Number / Asset Number or Call Sign
  • INPRESS TL Pressuriser location
  • HEPA Return Air Filter Location Option: Powered Return Air Filter
  • Cabin Pressure Display Location – Including the “System Check” maximum cabin pressure result with motor output capacity %

Fill in the BreatheSafe Service Tag with the following details:

  • Machine Serial Number and Installers details
  • Date installed and System Check result (max cabin pressure)
  • The set cabin pressure with actual pressure and motor percentage output
  • Verify the 250-pascal threshold was achieved = pass OR not achieved = fail**

Please upload machine and installation details in conjunction with the required images. A Commissioning Certificate will be sent to the email address you nominate. **Extended warranty for (RS20 & ISO 23875) BreatheSafe Systems is only applicable to operator enclosures meeting this requirement.

COMMISSIONING PROCEDURES – CABIN PRESSURISER

BREATHESAFE SYSTEM TROUBLE SHOOTING GUIDE *TOUCH CONTROL

FAULT| POSSIBLE CAUSE| SOLUTION
*ERR error code*| Poor sensor connection| Remove & refit pod connection cable
Corrupted coding| Access factory setup – default reset – pin 6759
Check filter alarm| Service hour timeout| Access Check Runtime menu – reset hours via 7597 code
Temperature / CO2 error| Sensor not connected| Fit sensor or disable via site access CO2 & or temperature menu
Pressuriser running at full speed/noisy| Filter blocked| Service filter
Door or window open| Ensure doors & windows securely shut
Cabin sealing capacity not adequate| Perform pressure test procedure & seal leak points as required
Sense pipe blocked| Ensure clear & not bent
Internal sensor damaged| Replace controller
**
No need to change setpoint
Filter blocking quickly| Defective cabin sealing| Perform pressure test procedure & seal leak points as required
Pre-cleaner failed| Check operation & replace if necessary
Display blank| Poor power supply| Check mains supply fuse & correct voltage
Check voltage & 20AMP supply/connections at pin
1 @ monitor
Check earth continuity at controller pin
12
Failed controller| Replace monitor
Controller showing 0.0 pressure| Fresh air filter blocked| Check filter condition & replace if required.
Low pressure alarm| Door or window open| Ensure doors & windows securely shut
Cabin sealing capacity not adequate| Perform pressure test procedure & rectify cab sealing
Pressuriser not operating| Ensure correct voltage 12v or 24v to pressuriser motor pin
A
Check 1.6V – 10V present at motor Pin
C
Check 20A Supply fuse
Check earth continuity Pin
B
Pressure sense tube blocked| Unplug at monitor & ensure clear flow to external of cabin
Ensure pressure tube fitted correct port
A
**
No need to change setpoint
Pressuriser not working| Poor power supply| Check 20A mains fuse & correct voltage
Ensure adequate wire size & no voltage drop
Ensure correct voltage 12v or 24v to pressuriser motor pin
A
Check 1.6V – 10V present at motor Pin
C
Poor earth| Check earth continuity @ motor pin
B
Motor faulty| Replace TL4M
Access Codes:| Site Access: 7597| Factory Setup: 6759**

USER SETTINGS INSTRUCTIONS

ENTER SET UP MODE
Start-Up Screen > Main Screen > Settings Button > Settings Screen > Site Access Button > Insert Pin > Site Menu
To enter the Setup mode, press the SETTING button.
Then enter SITE ACCESS MENU. Type in 4-number pin and press ENTER.

SET UP PARAMETERS
Placing the BreatheSafe 200027 unit into Setup mode allows the adjustment of the following parameters:

  • Time (hours/minutes/seconds)
  • Date (day/month/year)
  • Pressure alarm setpoint
  • Preferred cabin pressure
  • Alarm delay/ intervals of alarm
  • Calibration and system settings
  • Resetting of the data logging
  • Service reminders interval gap
  • Reset current runtime between services
  • CO2 settings and alarms

BreathSafe 794AC Haul Truck - USER SETTINGS
INSTRUCTIONS

PRESSURE SETPOINT
The pressure setpoint changes the pressure that the cabin will be maintained.
INPRESS TS maintains the pre-set pressure within the cabin compared to outside.
Enter Setup mode and select ADJUST SETPOINT button. Then, use the onscreen UP and DOWN buttons to change the corresponding fields.

BreathSafe 794AC Haul Truck - PRESSURE SETPOINT

PRESSURE ALARM SETTING
The mining industry benchmark for cabin pressure is 50 pascals and low- pressure is set at 20 pascals.
After a delay the alarm will activate if cabin pressure remains below the pre- set value. Enter Setup mode and select ADJUST SETPOINT button. Then, use the onscreen UP and DOWN buttons to change the corresponding fields.

BreathSafe 794AC Haul Truck - PRESSURE SETPOINT1

SERVICE INTERVAL
Use the onscreen UP and DOWN buttons to change the service interval setpoint.
To reset the current runtime to zero, press the RESET CURRENT RUNTIME button and enter the site access pin.

BreathSafe 794AC Haul Truck - PRESSURE SETPOINT2

DATE & TIME SETTINGS 

Change the recorded date displayed and measured by the INPRESS TS.

BreathSafe 794AC Haul Truck - PRESSURE SETPOINT3

PRESSURE ALARM BUZZER SETTING
To disable the buzzer, toggle through to the ENABLED and DISABLED buttons.

BreathSafe 794AC Haul Truck - PRESSURE ALARM BUZZER
SETTING

ALARM BUZZER SETTINGS

CALIBRATE ZERO SENSOR

Over long runtime, the 200027 may need recalibration. This screen allows the sensor to be recalibrated if more than 5 Pascals are out. To recalibrate, open windows and doors, turn off air conditioning, and any other device that may alter cabin pressure. Then, press the AUTO ZERO SENSOR button and leave the cabin while measuring. This process will reset the Zero Pressure.

BreathSafe 794AC Haul Truck - CALIBRATE ZERO SENSOR

CO2 SETTINGS

CO2 MODULE ENABLE/DISABLE
Enable or disable to CO2 module used for measuring CO2 levels within the cabin.

BreathSafe 794AC Haul Truck - CO2 MODULE ENABLE
DISABLE

CO2 PRIMARY ALARM POINT

The first alarm will sound when CO2 levels inside the enclosure reach this point.

BreathSafe 794AC Haul Truck - CO2 SETTINGS

CO2 ALARM DELAY
After CO2 (concentration in ppm) within the cabin reaches the 1000 ppm setpoint, the alarm will sound after this designated amount of time. The Alarm Delay adjusts the time between the INPRESS TS measuring CO2 concentration and sounding the alarm. Use the onscreen ADJUST buttons to change the corresponding fields. For example, press to toggle through Disabled / 1 – 10 minutes.

BreathSafe 794AC Haul Truck - CO2 SETTINGS1

CO2 CRITICAL ALARM MUTE RESET

The critical alarm is set at 2500 PPM and cannot be changed. The mute delay, however, can be configured.

BreathSafe 794AC Haul Truck - CO2 SETTINGS2

DATA DOWNLOAD

Data Download – Setting up RS232 Connection

BreathSafe 794AC Haul Truck - Data Download

BreathSafe 794AC Haul Truck - Data Download1

Data Download – Setting up RS232 Connection

BreathSafe 794AC Haul Truck - Data Download2

Data Download – Setting up RS232 Connection

BreathSafe 794AC Haul Truck - Setting up

Excel Data Instructions – Unformatted
Open an Excel sheet and select the first cell A-1. Next, press and hold down the CTRL button on your keyboard and then press the letter V on the keyboard.
This procedure will paste the copied data onto that Excel sheet. Once that data has been pasted onto the Excel sheet, click on ‘DATA’ on the pull-down menu, followed by ‘Text to Columns’. Next, select ‘Delimited’ on the newly opened window and click on Next.
Only select the ‘Comma’ button in the next window and then click ‘Finish’.
Then, the Excel fields will update such that each piece of data is placed in the correct columns.
The data is now ready for archiving.
Data Logging Formats
BU No: xxxxxx (the device number unique to each unit and used for identification – format = 000000)
Time: [09:25] Date: [25/07/12] Pressure: 32 (Pascals) as an example.

Alarm Type

0| = No alarm
1| = Low-pressure alarm
2| = Window open
3| = Door open

Express Warranty
All BreatheSafe products carry a warranty against defects in materials or workmanship, provided the defects are not from factors outside of BreatheSafe’s control (including neglect, lack of maintenanceimproper installation or operation, unauthorized servicing repair, etc.). BreatheSafe will replace goods defected in material or workmanship at our Queensland factory or designated branch*. All parts deemed as failed or faulty must be returned to BreatheSafe for evaluation unless otherwise stated inwriting. Note- Systems must be installed and commissioned as per BreatheSafe installation and commissioning instructions. Once commissioned, the online commissioning sheet must be filled in, extending the components warranty as below. In addition, the system must be serviced and maintained correctly and by trained and qualified personnel. This requisite includes BreatheSafe technicians, qualified automotive air-conditioning technicians, or qualified auto electricians.

Warranty period – Standard

  • 1 year or 10,000 hours (whichever occurs first).
  • Controllers – 1 year no extended warranty option.
  • Warranty Period Extension when commissioning documents are registered online within 28 days of installation
  • Extended warranty** only offered if commissioning maximum pressure test reaches at least 250Pa.
  • Brushless motor fixed speed two years, or 10,000 hours (whichever occurs first).
  • Variable speed brushless motor 15,000 hours, or 3 years** (whichever occurs first).

Must be supplied with a variable speed pressure controller, data download required for 3-year warranty option. Link to online Commissioning and Extended Warranty Registration form https://www.breathe-safe.com.au/commission/
What is not covered under Express Warranty?

  • Failures are due to incorrect application.
  • Damage resulting from neglect, misuse, lack of maintenance, improper installation, or operation, inappropriate or abnormal use, accidental or unauthorized servicing repair.
  • Failures are due to parts not being sold or approved by BreatheSafe.
  • Failures arising from any other cause that is not directly related to a defect in material or workmanship.

This Express Warranty is VOID if the product is altered, modified, or used in the manner it was not designed for, also including unauthorized repairs, or using maintenance and repair parts other than those supplied by BreatheSafe.

INPRESS TL WARRANTY

BreatheSafe responsibilities
If there is a defect in material or workmanship not caused by the excluded failures during the warranty period, BreatheSafe will either replace the defective goods at our Queensland factory, or designated branch. Alternatively, BreatheSafe may elect to provide new replacement parts, BreatheSafe approved repair parts or assembled components needed to repair the defect. BreatheSafe reserves the right to provide a refund of the purchase price in lieu of replacement or repair at BreatheSafe’s discretion. The replacement or repaired product will be sent to you freight prepaid by the customer or made available for pick-up on site.
Users Responsibilities
The customer should ensure that the system is maintained according to BreatheSafe service requirements and only authorized parts must be used to service and maintain BreatheSafe systems. In the event of a suspected warranty claim, BreatheSafe should be contacted in the first instance to arrange the repair or to assist with diagnosis. Claims should be made within one week of the repair.
After contacting BreatheSafe, you may be required to deliver or send the parts to BreatheSafe’s Queensland factory or designated branch.
Link to online Warranty claim form https://www.breathe-safe.com.au/warranty/

Exclusion and Limitations on Damages and Remedies

This warranty is provided in lieu of all other warranties, written or oral, whether expressed by affirmation, promise, description, drawing, model, or sample. To the extent allowed by law, all warranties other than this warranty, whether express or implied, including implied warranties of fitness for a particular purpose, are disclaimed. The maximum liability of BreatheSafe under this warranty shall not exceed the original purchase price of the product. Interference with the equipment by or abuse, or by operating the equipment at ambient temperatures or with electrical power characteristics outside the ranges indicated in our specification shall be excluded from this warranty, as shall consequential damages.
Excluded from any express warranty are costs incurred in relation to service outside our factory our designated
service branch, including traveling time, waiting time, transport costs, mechanical and overtime payments required. As per Australian Consumer Law: You are entitled to choose a refund or replacement for major failures with goods. If a failure with the goods or service does not amount to a major failure, you are entitled to have the failure rectified in a reasonable time. If this is not done, you are entitled to a refund for the goods and to cancel the contract for the service and obtain a refund of any unused portion. You are also entitled to be compensated for any other reasonably foreseeable loss or damage from a failure in the goods or service.
*This express warranty gives you specific legal rights, and you may also have other rights that vary from country to country.

+61 7 3276 7833
www.breathe-safe.com.au
****sales@breathe-safe.com
62 Mica Street, Carole Park, 4300, QLD
Controlled Document: M0074
Issue Date: 29/08/23
Revision: 1

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>