tuya HF3 Outdoor FingerKey And Reader User Manual

June 1, 2024
Tuya

Outdoor FingerKey & Reader

A                      B                      C

User Manual

INTRODUCTION

The device is a single door multifunction standalone access controller or a Wiegand output reader. It uses Atmal MCU assuring stable performance.
The operation is very user-friendly, and low-power circuit makes it long service life.

The device supports 1,000 users (988 common users + 2 panic users + 10 visitor users), all user data can be transferred from one to another (except fingerprint users). It supports multi access modes in card access, PIN access, fingerprint access, card + PIN access, or multi cards /PINs/ fingerprints access. It has extra features including block enrollment, interlock, Wiegand input & output interface…etc.

Three Versions Optional:
The device with Bluetooth function is optional
The device with big user capacity is optional
The device with WiFi function is optional

Features

Capacitive fingerprint sensor, Touch key
Metal case, anti-vandal
Waterproof, conforms to IP66
One relay, 1,000 users (988 common + 2 panic + 10 visitor)
PIN length:4~6 digits
EM card, EM+ Mifare cards optional
EM card: Wiegand 26~44 bits input & output
Mifare card: Wiegand 26~44 bits, 56bits, 58 bits input & output
Can be used as Wiegand reader with LED & buzzer output
Card block enrollment
Tricolor LED stabs display
Integrated alarm & buzzer output
Pulse mode, Toggle mode
User data can be transferred (except fingerprint users)
2 devices can be interlocked for 2 doors
Built-in light dependent resistor (LDR)for anti tamper
Backlit keypad, can set automatic OFF after 20 seconds

Specifications

User Capacity

Common User
Panic User
Visitor User

| 1000

988 (100 Fingerprint + 888 Card/PIN Users)
2
10

---|---
Operating Voltage

Working Current
Idle Current

| 12~18V DC

≤150mA
≤60mA

Proximity Card Reader

Radio Technology
Read Range

| EM / EM + Mifare

125KHz / 125KHz + 13.56MHz
2~6 cm

PIN Length| 4~6 digits
Wiring Connections| Relay Output, Exit Button, Alarm, Door Contact, Wiegand Input, Wiegand Output
Relay

Adjustable Relay Output Time
Lock Output Load

| One (NO, NC, Common)

0~99 Seconds (5 seconds default)
2 Amp Maximum

Wiegand Interface

PIN Output

| EM card: Wiegand 26~44 bits input & output.
Mifare card: Wigand 26~44bits 56bits, 58bits input & output.
(Factory default: Wiegand 26bits for EM card, Wiegand 34bits for Mifare card)
4bits, 8 bits(ASCII),10 digits Virtual Number
(Factory default: 4bits)
Environment

Operating Temperature
Operating Humidity

| Meets IP66

-30°C ~ 60°C (-22°F ~ 140°F)
0%RH~98%RH

Physical

Colour
Dimensions

Unit Weight
Shipping Weight

| Zinc-Alloy (A/B)       ABS(C)

Silver &Black (A/B)     Black(C)
L148 x W43.5 x D22 (mm) — A/C
L165 x W44 x D22 (mm) — B
330g–A    415g — B    190g — C
405g–A    500g — B     280g — C

Carton Inventory

A                      B                      C

  Diode IN4004 (For relay circuit protection)

  Wall Anchors

  Self Tapping Screws: Φ4*25mm

   Screw Driver

    Master Card

INSTALLATION

Remove the back cover from the unit
Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
Knock the supplied robber bungs to the screw holes(A,C)
Fix the back raver firmly on the wall with 4 flat head screws
Thread the cable through the cable hole(B)
Attach the unit to the back cover

A                                                 B

C

Wiring

Wire Color| Function|

Notes

---|---|---
Basic Standalone Wring
Red| DC +| 12-18V DC Power Input
Black| GND| Negative Pole of DC Power Input
Blue| Relay NO| Normally Open Relay Output (install diode provided)
Purple| Relay Common| Common Connection for Relay Output
Orange| Relay NC| Namely Closed Relay Output (Install diode provided)
Yellow| OPEN| Request to Exit(REX) Input
Pass-Through Wring (n/legend Reader or Controller)
Green| Data 0| Wiegand Output (Pass-through) Data 0
White| Data 1| Wiegand Output (Pass-through) Data 1
Advanced Input and Output Features
Grey| Alarm Output| Negative contact for Alarm
Brown| Contact Input| Door/Gate Contact Input (Normally Closed)

Sound and Light Indication

Operation Status

| LED|

Buzzer

---|---|---
Stand by| Red light bright| –
Enter into programming mode| Red light shines| One beep
In the programming mode| Orange light bright| One beep
Operation error| –| Three beeps
Exit from the Programming mode| Red light bright| One beep
Open lock| Green light bright| One beep
Alarm| Red light Shines quickly| Beeps

Basic Configure

Enter and Exit Program Mode

Programming Step Keystroke Combination
Enter Program Mode * (Master Code) #

(Factory default is 123456)
Exit Program Mode| *****

Set Master Code

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code) #
2. Update Master Code 0 (New Master Code) # (Repeat New Master Code) #

(Master code is any 6 digits)
3. Exit Program Mode| *****

Set the Working Mode

Notes: The device has 3 working modes: Standalone Mode, Controller Mode, Wiegand Reader Mode, chase the mode you use. (Factory default is Standalone Mode / Controller Mode)

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code) #

2. Standalone/Controller Mode
OR
2. Wiegand Reader Mode| 7 7 # (Factory default)

7 8 #

3. Exit| *****

STANDALONE MODE

The device can work as Standalone Access Control for single door. (Factory default mode) — 7 7#

Connection Diagram

Common Power Supply

tuya HF3 Outdoor FingerKey And Reader - c1

Attention:
Install a 1N4004 or equivalent diode is needed when use a common power supply, or the keypad might be damaged. (1N4004 is included in the packing)

Access Control Power Supply

tuya HF3 Outdoor FingerKey And Reader - c2

Programming
Programming will be vary depending on access configuration. Follow the instructions according to your access configuration.

Notes:
> User ID number: Assign a user ID to the access fingerprint/ card/ PIN in order to back it.

The Common User ID:

– Fingerprint user ID: 0 ~ 98
– PIN/ Card user ID: 100 ~ 987
Master Fingerprint User ID: 99
Panic User ID: 988~989
Visitor User ID: 990~999

IMPORTANT: User IDs do not have to be proceeded with any leading zeros.
Recanting of User ID is critical. Modifications to the user means the User ID be available.

> Proximity Card:
Proximity Card: EM card/ EM+ Mifare cards

> PIN: Can be any 4-6 digits except 8888 which is reserved.

Add Common Users

(Fingerprint user ID: 0 ~ 98, PIN/ Card user ID: 100 ~ 987; PIN length: 4~6 digits except 8888)

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

Add Fingerprint User
2. Using Auto ID
(Allows the device to assign Fingerprint to next available User ID number)
OR
2. Select Specified ID
(Allows Master to define a specific User ID to associate the fingerprint to)| 1 (Fingerprint) (Repeat Fingerprint) (Repeat Fingerprint again)
Fingerprints can be added continuously.
1 (User ID) # (Fingerprint) (Repeat Fingerprint)
(Repeat Fingerprint again) Fingerprints can be added continuously.
Add Card User
2. Using Auto ID
(Allows the device to assign Card to next available User ID number)
OR
2. Select Specific ID
(Allows Master to define a specific User ID to associate the card to)
OR
2. Add Card: Block Enrollment
(Allows Master to add up to 888 cards to the Reader in a single step)
Takes 2 minutes to program.| 1 (Read Card)/ (Input 8/1 0/17 Digits Card Number)#
The cards can be added continuously. 1 (User ID) # (Read Card)/ (Input 8/1 0 /17 Digits Card Number) # 1 ( User ID) # (Card Quantity) # (The First Card 8/1 0 /17 Digits Number)#
Cards’ number must be consecutive; Card quantity = number of cards to be enrolled.
Add PIN User
2. Using Auto ID
(Allows the device to assign PIN to next available User ID number)
OR
2. Select Specific ID
(Allows manager to define a specific User ID to associate the PIN to)| 1 (PIN) )#
The PINs can be added continuously 1 (User ID) # (PIN )#
3. Exit| *****

Tips for PIN Security (Only valid for 6 digits PIN):

For higher security we allow you to hide your correct PIN with other numbers up to a max of 10 digits.

Example PIN: 123434
You could use (123434) or * (123434)
(“
” can be any numbers from 0~9)

Add Master Fingerprint (By Specified ID: 99)

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #
1. Add Master Fingerprint **1 (99) # (Fingerprint) (Repeat Fingerprint)

(Repeat Fingerprint again)**
3. Exit| *****

Add Panic Users (Valid for Card/ PIN Users)

(User ID number is 988, 989; PIN length:4~6 digits except 8888)

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Add Card
OR
2. Add PIN| 1 (User ID) # (Read Cam/Input 8/10/17 Digits Card number) #

1 (User ID)# (PIN ) #

3. Exit| *****

Add Visitor Users (Valid for Card/ PIN Users)

(User ID number is 990~999; PIN length: 4~6 digits except 8888)
There are 10 groups Visitor PIN/card available, the users can be specified up to 10 times of usage, after a certain number of times, i.e. 5 times, the PIN/card become invalid automatically.

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Add Card
OR
2. Add PIN| 1 (User ID)# (0~9) # (Read Card)/ (Input 8/10/17 Digits Card Number) #

1 (User ID)# (0~9)# (PIN)#
(0~9 means times of usage, 0=10 times)

3. Exit| *****

Change PIN Users (PIN length:4~6 digits except 8888)
(Note: WiFi versions don’t support change PIN)

Programming Step Keystroke Combination

Note: Below is done outside programming mode, users can undertake this themselves
Change PIN| * (User ID) # (Old PIN) # (New PIN) # (Repeat New PIN) #*
Change PIN of Card + PIN access mode (There will auto allocate PIN (8888)to cards when adding)|
(Read Card) (Old PIN) # (New PIN) # (Repeat New PIN)

**

Delete Users
Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Delete User- By Fingerprint/ Card/ PIN
OR
2. Delete User-By ID number
OR
2. Delete User-By Card number
OR
2. Delete ALL Users| 2 (Input Fingerprint)/ (Read Card)/ (Input PIN) #
The users can be deleted continuously. 2 (User ID )# 2 (input 8/10/17 Digits Card Number)# 2 (Master Code) #
3. Exit| *****

Set Relay Configuration

The relay configuration sets the behaviour of the output relay on activation.

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Pulse Mode
OR
2. Toggle Mode| 3 (1~99)# (factory default)
The relay time is 1-99 seconds.
(Default is 5 seconds)
3 0 #
Sets the relay to ON/OFF Toggle mode
3. Exit| *****

Set Access Mode

For Multi user access mode, the interval time of reading can not exceed 5 seconds, or else, the device will exit to standby automatically.

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2 Fingerprint Access
OR
2 Card Access
OR
2 PIN Access
OR
2 Card + PIN Access
2 Multi User Access
OR
2 Fingerprint or Card or PIN Access| 4 0 #

4 1 #

4 2 #

4 3 # (WiFi versions don’t support this function)

4 3 (2~9) #
(Only after 2-9 valid users, the door be opened)

4 4 # (factory default)

3. Exit| *****

Set Strike-out Alarm

The strike-out alarm will engage after 10 failed entry attempts (Factory is OFF). It can be set to deny access for 10 minutes after engaging or disengage only after entering a valid Fingerprint/ card/ PIN or Master code/ fingerprint/ card.

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Strike-Out OFF
OR
2. Strike-Out ON
OR
2. Strike-Out ON (Alarm)
Set Alarm Time| 6 0 # (factory default)

6 1 # Access will be denied for 10 minutes
(Exit button is still workable)

6 2 #

5 (0 ~ 3)# (factory default is 1 minute)
Enter Master Code # or Master Fingerprint / Card or valid user fingerprint/card / PIN to silence

3. Exit| *****

Set Door Open Detection

Door Open Too Long (DOTE) Detection
When use with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not dosed after 1 minute, the inside buzzer will beep automatically to remind people to close the door. The beep can be stopped by closing the door, master users or valid users, or else, it will continue to beep the same time with the alarm time set.

Door Forced Open Detection
When use with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened by force, the inside buzzer and external alarm (if there Is) will both operate, they can be stopped by master users or valid users, or else, it will continue to sound the same time with the alarm time set.

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Disable Door Open Detection
OR
2. Enable Door Open Detection
Set Alarm Time| 6 3 # (factory default)

6 4 #
5 (0 ~ 3)#
(factory default is 1 minute)

3. Exit| *****

The function of Set Alarm Time also apply for anti-tamper alarm

Set Audible and Visual Response
Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Disable Sound
Enable Sound
OR
2. LED Always OFF
LED Always ON
OR
2. Keypad Backlit Always OFF
Keypad Backlit Always ON
Keypad Backlit Automatic OFF| 7 0 #
7 1 # (factory default)
7 2 #
7 3 # (factory default)
7 4 #
7 5 #
7 6 #
(factory default)
Automatic OFF after 20 seconds, it will go ON by pressing any key (this key isn’t taken into consideration)
3. Exit| *****

Master Fingerprint/ Card Usage

Using Master Fingerprint/ Card to add and delete users

Add Fingerprint/ Card/ PIN Users|

  1. Input (Master Fingerprint / Card)

  2. Input (Fingerprint three times) or (Card) or (PIN #)
    Repeat step 2 for additional users

  3. Input (Master Fingerprint / Card) again

Delete Fingerprint/Card/ PIN Users|

  1. Input (Master Fingerprint/ Card Twice within 5s)

  2. Input (Fingerprint) or (Card) or (PIN #)
    Repeat step 2 for additional users

  3. Input (Master Fingerprint/ Card) again

Users Operation & Reset to Factory Default

> Open the door: Read valid use fingerprint or user card or input valid user PIN #

> Remove Alarm: Enter Master Code # or Master Fingerprint/ Card or valid user fingerprint / card / PIN

> To reset to factory default &Add Master Card: Power off, press the Exit Button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card/ 13.56MHz Mifare card. the LED will turn into red, means reset to factory default successfully. Of the card reading, it is the Master Card.

Remarks:
(1) If no Master Card added, must press the Exit Button for at least 5 seconds before release.(this will make the previous registered Master Card invalid)
(2) Reset to factory default, the user’s information is still retained.

CONTROLLER MODE

The device can work as Controller, connected with the external Wiegand reader.
(Factory default mode) — 7 7 #

Connection Diagram

tuya HF3 Outdoor FingerKey And Reader - c3

  1. Special Power Supply
  2. Reader
  3. The Device

Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply. or the reader might be damaged. (1N4004 is included in the packing)

Set Wiegand Input Formats

Please set the Wiegand input formats according to the Wiegand output format of the external Reader.

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #
2. Wiegand Input Bit For EM Card: 8 (26~44) #

(factory default is 26bits)
For Mifare Card: 8 0 (26~44, 56, 58) #
(factory default is 34bits)
3. Disable Parity Bit
Enable Parity Bit| 8 0 #
8 1 #
(factory default)
4. Exit| *****

Note: For connecting Wiegand readers with 32,40,56 bits output, need disable parity bits.

Programming
> Basic Programming is the same as Standalone Mode
> There are some exceptions for your attention:
The device Connected with External Card Reader
– If EM/Mifare card reader: users can be added/deleted on either the device or external reader.
– If HID card reader : users can only be added/deleted on external reader.

The device Connected with Fingerprint Reader
For example:
Connect SF1 as the fingerprint reader to the device.
Step 1: Add the Fingerprint (A) on SF1 (Please refer to SF1 manual)
Step 2: Add the same Fingerprint(A) on the device:

1 Enter Program Mode: * (Master Code) #

2    1 (Press Fingerprint A once on SF1) # (ID auto allocated)
OR
2    1 (User ID) # (Press Fingerprint A on SF1)# (Select specific ID)
3| **Exit: ***

The device Connected with Keypad Reader
The keypad reader can be 4 Bits, 8 Bits (ASCII), or 10 Bits output format. Choose the below operation according to the PIN output format of your reader.

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #
2. PIN input bits 8 (4 or 8 or 10) # (factory default is 4 bits)
3. Exit *****

Remarks:  4 means 4 bits, 8 means 8 bits, 10 means 10 digits virtual number.

> Add PIN Users:
To add PIN users, after enter into programming mode on the device, PIN(s) can be input/ added on either the device or the external Keypad Reader.

> Delete PIN Users: the same way as add users.

WIEGAND READER MODE

The device can work as Standard Wiegand Reader, connected to the third party Controller — 7 8 #

Connection Diagram

tuya HF3 Outdoor FingerKey And Reader - c4

  1. The Device
  2. Access Controller

Notes:

When set into Wiegand Reader mode, nearly all settings in Controller Mode will become Invalid, and Brown & Yellow wires will be redefined as below:
– Brown wire: Green LED light control
– Yellow wire: Buzzer control

If you need to connect Brown/Yellow wires:
When the input voltage for LED is low, the LED will him into Green; and when the input voltage for Buzzer is low, it will sound.

Set Wiegand Output Formats

Please set the Wiegand output tomes of Reader according to the Wiegand input formats of the Controller.

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Wiegand output bits

PIN output bits

| For EM Card: 8 (26 ~ 44) #
(factory default is 26bits)
For Mifare Card: 8 0 (26~44, 56, 58)#
(factory default is 34bits)
8 (4 or 8 or 10) # (factory default is 4 bits)
3. Disable Parity Bit
Enable Parity Bit| 8 0 #
8 1 #
(factory default)
4. Exit|

Note: For connecting Wiegand controller with 32, 40, 56 bits input, need disable parity bits.

ADVANCED APPLICATION

Collection Card Mode
After this mode is turned on, all cards can open the lock. At the same time, the card is added to the device.

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Collection Card Mode OFF
OR
2. Collection Card Mode ON| 9 2 # (factory default)

9 3 #

3. Exit| *****

User Information Transfer (Valid for Card / PIN Users)
The device supports the User Information Transfer function, and the enrolled user (cards, PINs) can be transferred from one (lets name it Master Unit) to another (let’s name It Accept Unit).

Connection Diagram:

tuya HF3 Outdoor FingerKey And Reader - c5

a) Power
b) The Device

Remarks:

The Master units and Accept units must be same sodas devices.
The Master Code of the Master Unit and the Accept Unit must be set to the same.
Program the transfer operation on Master Unit only.
If the Accept Unit is already with the users enrolled, it will be covered after transferring.
For full 900 users enrolled, the transfer takes about 30 seconds.

Set Transferring on Master Unit:
Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #
2. Set transferring 9 8 #

Within 30 seconds, Green LED shines, after one beep, the LED will turn into Red, which means the users’ information has been transferred successfully.
3. Exit| *****

Interlock
The device supports the Interlock Function. It is of two Devices for two doors, and mainly used for banks, prisons, and other places where a higher level security is required.

Connection Diagram:

tuya HF3 Outdoor FingerKey And Reader - c6

  1. DC Power Supply
  2. The Device

Remarks: The Door Contact must be installed and connected as the diagram.
Let’s name the two Devices as “A” and “B” for two doom “1” and “2”

Step 1:
Enroll the users on Device A, then transfer the users’ information to Device B by “User Information Transfer” function.

Step 2:
Set both of the two Devices (A and B) to Interlock function

Programming Step Keystroke Combination
1. Enter Program Made * (Master Code) #

2. Disable Interlock
OR
2. Enable Interlock| 9 0 # (factory default)

9 1 #

3. Exit| *****

If enable interlock, when and only door 2 Is dosed, the user can read the valid fingerprint/card or input PIN on Reader A, door 1 will open; then when and only door 1 closed, read valid fingerprint/card or input PIN on Reader B, door 2 will open.

Simplified Instruction

Function Description| Operation
Enter the Programming Mode| * – Master Code – #
then you can do the programming
(123456 is the factory default master code)
Change the Master Code|
0 – New Code – # – Repeat the New Cods – #
(code: 6 digits)
Add Card User|
1 – Read Card – #
(can add cards continuously)
Add Fingerprint User| 1-Fingerprint-Repeat Fingerprint-Repeat Fingerprint Again-#
Add PIN User|
1 – PIN – #
(The PIN is any 4~6 digits except 8888 which is reserved)
Delete User|
2- Fingerprint-#
2-Read Card-#
2-PIN-#*
Exit from the Programming Mode|

How to release the door**
Fingerprint User| Input Fingerprint
Card User| Read Card
PIN User| Input PIN #

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals