PRODUCT MANUALECO SOLAR BOOST
FOR HEATING WATER, BOILER
GREEN BOOST 3000
GREEN BOOST 3000 ECO Solar Boost For Heating Water Boiler
Congratulations on choosing our high-quality eco solar boost – Green Boost 3000 (DC 1210-350V) for water heating, boiler, heating floor and others.
Above the output voltage of 250V from the panels, the inverter offers the output of approx. 245V!
TECHNICAL DATA GREEN BOOST 3000
Max constant power | 3000W |
---|---|
Max power | 6000W |
Efficiency | > 95% |
Output voltage | 120 ~ 245VAC/ 50Hz |
Output voltage from panels PV | 120VDC ~ 350VDC |
Max panels power | ≤ 4500W |
Output voltage waveform | Modified sine wave |
Connection of PV panels | Series or series-parallel |
Power connector (input) | MC4-2pcs |
Output socket | 2pcs |
Working modes | MPPT / STABLE |
Displayed | LED |
Cooling | Yes |
Overload protection | Yes |
Short circuit protection | Yes100±10℃ |
Thermal protection | Built-in fan |
Warning system | Sounds and light signals |
Storage temperature | od -25~+55 ℃ |
Operating temperature | od -20~+45 ℃ |
Weight | 3,3kg |
Dimensions | 311x232x140mm |
INTENDED USE
The eco solar boost – Green Boost 3000 (DC 1210-350V) is designed to power
heating devices such as boilers, heaters, electric heaters or heating mats
directly from PV panels. The system requires: 4 to 9 typical PV panels (250W –
400W) connected in series, with a total voltage from 120V to 350V. Our
inverter is equipped with internal maximum power protection of 3kW. However,
the total power of the panels connected to the inverter should not be higher
than 5kW.
Green Boost 3000 (DC 1210-350V) allows to connect two heating devices (e.g.
two boilers). One will be heated first and the second one will be heated only,
if the thermostat of the first one stops receiving energy from the
inverter.This ensures that energy from the PV panels will not be lost when one
of the units reaches a set temperature.
Green Boost 3000 (DC 1210-350V) is equipped with MPPT. Thanks to that, the
inverter will automatically adjust to the power of boiler and maximizes the
amount of energy drawn from PV panels.
INSTALLATION
To connect the PV panels to the inverter, use suitable PV installation cables
with a cross section not less than 4mm. Using wires that are too thin will
cause heating up and a voltage decreasing at the inverter input. In extreme
cases it can cause a fire.
The inverter requires unobstructed air circulation for proper operation. Do
not, under any circumstances, cover the ventilation holes as this may be a
direct cause of verheating and damage of the device. To improve heat
dissipation and for your own safety, we suggest to screw the inverter
vertically to nonflammable surfaces (concrete, metal).
SAFETY
The eco solar boost – Green Boost 3000 (DC 1210-350V) produces a dangerous
voltage at the output that may cause electrical shock or fire. To avoid that,
we suggest to follow all safety rules that apply to electrical equipment
(230V).
Please note, that the high voltage may persist even after disconnecting the
power supply for a quarter of a minute.
Any repairs should only be carried out by an authorised service centre. Do not
put the voltage inverter in a high-humidity area, near a fire source, flammable
substances. Do not also expose it to direct sunlight. If the device gets wet,
immediately disconnect the power supply. Do not connect a load greater than
that permitted for continuous operation to the inverter output. Overloading
may cause damage to the device.
In case of fire, use a fire extinguisher designed for extinguishing electrical
equipment.
Under no circumstances may the input and output of eco solar boost – Green
Boost 3000 (DC 1210-350V) be connected to the power grid.
CONNECTION URGENT!
The polarity of the supply voltage is very important while connecting PV
panels to inverter. The reverse wiring will cause damage to the inverter and
void the warranty!
The eco solar boost – Green Boost 3000 (DC 1210-350V) has two MC4 connectors
which must be connected to the PV installation. The connector shaped should be
connected to the negative pole of the PV installation and the connector shaped
should be connected to the positive pole of the PV installation.
ADC safety switch, designed for such installations, shall be installed on the
PV system power cord.
We connect device e.g. an electric boiler to the inverter output marked – “1”
When the inverter detects the presence of voltage from the PV panels within
the appropriate range, the inverter will automatically turn on. This will be
confirmed by the LED indicator.
Optionally, a second energy consumer can be connected to the inverter output
marked “2”. This can works only with a bi-metal thermostats.
Electronic temperature controllers can only work with an output “1”. Lack of
activities on both outputs for a long time will cause a delay of load sense on
output up to several minutes.
USE
The eco solar boost inverter Green Boost 3000 (DC 1210-350V is equipped with
two power outputs – type E (labelled “1” and “2)”. After connecting the
correct supply oltage from the solar power system (120350V ), the inverter
checks the presence of connected receivers.
In the case of connecting two resistance receivers, firstly, the device
connected to the socket “1” will be powered. When the device stops consuming
energy, the eco solar boost inverter Green Boost 3000 (DC 1210-350V will
switch to power socket “2”. However, if the load on socket “1” will reappear,
the inverter it will automatically cut the power supply to output “2” and
start to power outputs “1”.
SOLAR STATUS – When the PV voltage is greater than 80% of the rated
voltage of the device, the indicator lamp will be lit. Otherwise, it will
blink.
OUTPUT PRIMARY – It lights when socket 1 is working
OUTPUT SECONDARY – It lights when socket 2 is working
PV VOLTAGE – Actual PV input voltage
PV CURRENT – Actual PV input current
OUTPUT VOLTAGE – Output voltage status, shows the actual output voltage
current of the inverter
MPPT MODE – It lights when the MPPT mode is on
OVER HEAT – It lights when the inverter is overheated
SYSTEM FAULT – It lights when the PV voltage is too high or the inverter
does not work properly (continuous light) or warns of overload.
CONNECTING DIAGRAM „1” i „2”
SECONDARY (ACTIVE ONLY WHEN NO LOAD ON PRIMARY)
WARRANTY SERVICE COMMENTS
DATE OF PURSCHASE|
---|---
SHIPPING ADDRESS|
SIGNATURE / STAMP|
DAMAGE DESCRIPTION|
SERVICE COMMENTS|
Correct Disposal of This Product (Waste Electrical & Electronic
Equipment)
The marking on the product or in related texts indicates that it is at the end
of its useful life should not be disposed of with other household wastes. To
avoid harmful effects on the environment and human health as a result of
uncontrolled waste disposal, please separate the product from another type of
waste and responsible recycling to promote the reuse of material resources as
a permanent practice. Users in the households should contact the retailer
where they purchased the product, or with a local authority. Business users
should contact their supplier and check the terms of the contract purchase.
The product should not be disposed of with other commercial waste.
PRODUCENT:
VOLT POLSKA Sp. z o.o.
ul. Świemirowska 3 81-877 Sopot
www.voltpolska.pl
sales@voltpolska.pl (58) 341-05-06 |
przemek@voltpolska.pl (58) 341-38-80 |
bartek@voltpolska.pl (22) 100-42-99
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>