Product Information
Specifications
- Frequency Range: 0 to 3 GHz
- Discharge Voltage: Max Discharge Current
- Insertion Loss: VSWR Impedance Max Input Power
- Connector Types: UHF Female SO-239 & UHF Female SO-239 M4 Screw
- Materials: Body – Nickel Plated Brass
- Dimensions: 2.24 x 1 in (57 x 25 mm)
Product Usage Instructions
Installation
- Install the coaxial lightning arrester between outdoor antennas and radio equipment.
- Ensure the arrester is installed as close as possible to the equipment to be protected.
- Weatherproof all outdoor coax connections to minimize moisture damage.
Connection
- Use the UHF Female SO-239 connectors for in-line installation into your coax cable feed line.
- Ensure proper grounding by utilizing the ground lug on the housing.
- The arrester can be installed in either orientation as both connector ports are equally protected.
Maintenance
- Regularly inspect the arrester for any signs of damage or wear.
- Replace the arrester if it has been exposed to a significant electrical surge or lightning strike.
FAQ
-
Q: Where should the coaxial lightning arrester be installed?
A: The arrester should be installed between outdoor antennas and radio equipment, preferably at the point where the coax cable enters the building. -
Q: What is the frequency range of this lightning arrester?
A: The lightning arrester operates in the frequency range of 0 to 3 GHz.
Applications
Protects Outdoor Antennas for
- HF, VHF, UHF, GMRS, Two-Way Radio
- Amateur (Ham) Radio Installations
- Citizens Band (CB) Radio
- P25 Public Safety Applications
Product Features
- Reliable Wide-band Performance (DC ~ 3 GHz)
- 230V Discharge Voltage (2.5x Standard)
- Bi-Directional Protection
- Very Low RF Insertion Loss (Signal Attenuation)
- Gas Discharge Tube with Multi-Strike Capability
- High Quality Construction – Outdoor Mountable
- UHF Female – UHF Female (SO-239) Connectors
- Ground Wire Lug
Ordering Information
-
Part No.
ANT-233-002 -
Description
Proxicast Coaxial Lightning Arrester for 0 to 3 GHz (UHF-Female/UHF-Female)
General Description
- This 230V gas discharge tube coaxial lightning surge protector features UHF Female SO-239 connectors and wide-band operation from DC to 3 GHz with low RF insertion loss. It effectively dissipates the excess energy caused by lightning strikes, preventing it from reaching your precious equipment. It can absorb up to 2.5 times the energy of standard 90V arresters.
- The arrester has female SO239 sockets for in-line installation into your coax cable feed line, providing reliable protection with minimal signal loss.
- This antenna surge protector will pass DC, so it is suitable for applications where DC is carried through the coax cable, such as remote amplifiers and LNAs. Both connector ports are equally protected – it can be installed in either orientation. A ground lug on the housing provides superior grounding.
- Pro-Grade arresters are constructed of high-quality materials to withstand the harshest weather conditions.
- A coaxial lightning suppressor should be installed between outdoor antennas and radio equipment and as close as possible to the equipment to be protected, often at the point where the coax cable enters the building. This protects equipment, structures and personnel from high-energy electrical pulses carried through the coax cable either from a direct or nearby lightning strike
- Consult your local building, fire, safety, or insurance codes for proper lightning protection system design for your application.
- All outdoor coax connections should be weather-proofed to minimize damage caused by moisture in the connectors or cabling. Use our Self-Bonding silicone tape (ANT-900-002) for fast and easy connection sealing.
Specifications
Electrical Specifications
Parameter Rating
Frequency Range
| ****
0 to 3 GHz
Discharge Voltage| DC 230V – replaceable gas discharge tube
Max Discharge Current| 10 kA (8/20 μs)
Insertion Loss| < 0.2 dB
VSWR| < 1.2
Impedance| 50 Ohm
Max Input Power| 200 W
Mechanical Specifications
Parameter Rating
Connector Types| UHF Female SO-239 & UHF Female SO-239
Ground Lug| M4 Screw
Materials
(RoHS Compliant)
| ****
Body: Nickel Plated Brass
Dimensions
| ****
2.24 x 1 in (57 x 25 mm)
Weight| 4 oz (113g)
Operating Temperature| -40°C to +85°C
Operation of this device outside the parameter ranges given above may cause permanent damage.
Mechanical Dimensions
Dimensions in millimeters
Contact Information
For the latest specifications, additional product information, worldwide sales and information about Proxicast:
- Web: www.proxicast.com
- Tel:
- Email: sales@proxicast.com
- Proxicast • 312 Sunnyfield Drive, Suite 200 • Glenshaw, PA 15116 USA.
For technical questions and application information:
- Email: support@proxicast.com.
Important Notice
The information contained herein is believed to be reliable. Proxicast makes
no warranties regarding the information contained herein. Proxicast assumes no
responsibility or liability whatsoever for any of the information contained
herein.
Proxicast assumes no responsibility or liability whatsoever for the use of the
information contained herein. The information contained herein is provided “AS
IS, WHERE IS” and with all faults, and the entire risk associated with such
information is entirely with the user. All information contained herein is
subject to change without notice. The information contained herein or any use
of such information does not grant, explicitly or implicitly, to any party any
patent rights, licenses, or any other intellectual property rights, whether
concerning such information itself or anything described by such information.
Proxicast products are not warranted or authorized for use as critical
components in medical, life-saving, or life-sustaining applications, or other
applications where a failure would reasonably be expected to cause severe
personal injury or death.
© Copyright Proxicast, LLC. All rights reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>