BONDIR R2 Pro Relieve + Recover Pro Percussive Massager User Guide

June 1, 2024
BONDIR

BONDIR R2 Pro Relieve + Recover Pro Percussive Massager

BONDIR R2 Pro Relieve + Recover Pro Percussive
Massager

Thank You

Thank you for purchasing the BONDIR Relieve and Recover Pro Percussive Massager. Please read the User Manual carefully before use.

Important Safeguards

Please follow these important safety precautions:

  1. This product is not intended for use by children under 18 years of age.
  2. Please consult a doctor prior to use.
  3. Intended for use on clean, dry skin for muscle relief.
  4. Not intended for use above the neck or on any other sensitive areas. Intended for soft tissue use only.
  5. Do not massage over bruises or open wounds. Discontinue use if you are experiencing any abnormal pain or discomfort.
  6. Do not place any objects into the percussive massager vents.
  7. Keep the vents free of dust and debris.
  8. Do not immerse in water or allow water to enter the percussive massager vents.
  9. Keep product away from fire or excessive heat source.
  10. Please keep hair away from the shaft and back of the vibrating head to prevent catching hair into the vibrating mechanism.
  11. After charging is complete, remove device from charger.
  12. Please follow manual instructions.
  13. The applicable voltage range of this product is 5V-9V. The recommended input current range is 0.5A-2A. Exceeding or operating below the range can easily damage the product.

WARNINGS

If you’re experiencing any of the symptoms or medical conditions stated below, please contact your doctor before proceeding.
Pregnancy, complications of diabetes (such as neuropathy or retinal damage), wearing a pacemaker, recent surgery, epilepsy, migraine, disc herniation, advancement of the spine, vertebral detachment, or rigid joints of the spine, recent joints replacement surgery or IUD, metal needle or steel plate or any problems related to your health. These contraindications do not mean that you are not able to use vibration equipment or training equipment, but we recommend that you consult a doctor before use.
Practical experience has shown that in many cases, the integration of vibration training into a treatment regimen is also a therapeutic recommendation. This must be done with the advice of a doctor, expert or physical therapist.

ENVIRONMENTAL PROTECTION

At the end of the product life, please discard product by sending back to after-sales service or donating to a recycling station near you.

The name and content of the harmful substance in the product:

Component Toxic and harmful substances or elements
(Pb) (Hg)
Shell 0
Circuit Board Component X
Metal Parts 0
Rubber Parts 0
Charging line 0

This table is prepared in accordance with the provisions SJ/T 11364.
: Circuit board component including components of printed circuit board machine, such as resistors, capacitors, integrated circuits, connectors, etc.
0 : Indicates the hazardous substances in all homogeneous materials for the part is below the limit of the GB/T 26572.
X : Indicates the hazardous substances in at least one homogeneous materials of the part exceeds the limit of the GB/T 26572.

ENVIRONMENTAL PROTECTION PERIOD DESCRIPTION

10 year protection. Guaranteed protection based on proper use in accordance with manual guidelines and if harmful substances or elements are contained and not leaked. It does not cause pollution to the environment or serious damage to people and property.

PRODUCT DESCRIPTION

  1. Powerful high-torque, but quiet motor
  2. Soft EVA massage heads provide a comfortable massage experience while reducing damage to the bone
  3. Fully charge the Li-ion battery {charging tim1e may vary)
  4. Small and comfortable handle with non-slip gripping (40mm)
  5. Wireless, lightweight, and portable {0.7kg)
  6. Sweat proof, user-friendly design

Speed – Level Indicator Light {Top 3 Lights on Left Side): 1-3 Level + speed 4 variable speed Battery Level Indicator {Bottom Light on Left Side): See Charging Page 7 ON/OFF Switch: Hold for 2 seconds to Start/Stop the device, press to adjust the speed level from level 1 to level 3.

Assembly Guide:
Make sure attachments are firmly in place. For the U-shaped attachment, align the lines to ensure proper insertion.
For the Heated Flat Head attachment, align notch and push firmly to insert. Do not twist attachment.
Product Description

PRODUCT WARRANTY

1-YEAR LIMITED WARRANTY
This product is under warranty for a period of 365 days from the date of purchase (1 year). In the event of a claim while your product is under warranty, please register your warranty.

REGISTRATION INSTRUCTIONS

  1. Go to shopsonix.com/pages/warranty
  2. Click on “Warranty Registration Form”
  3. Fill out Warranty Registration form and click submit

MAINTENANCE, CLEANING, STORAGE, AND TRANSPORTATION

Use a slightly damp towel to clean device and dry with a soft cloth. For storage or travel, store the device in supplied portable bag. Store in a cool, dry place.
If not planning on using for a long period of time, please clean device prior to storage and remember to charge it every month to maintain battery life.

CHARGING

  1. Fully charge the battery before initial use
  2. Plug the included USB-C power cable into the R2 Pro
  3. Plug the other end into a power source or wall adapter (not included)
  4. The power indicator on the battery will flash while the device is charging
  5. Light indications:
    Blue Light – 75%-100% power
    Purple Light – 50%-75% power
    Red Light – 30%-50% power
    Blinking Red Light – 10%-30% power, please charge asap
  • Power less than 10%, massager will self shut down 6. The device can be used while battery is charging 7. Recharge battery when battery indicator begins to flash Red Light 8. The average battery life per full charge is up to 5 hours depending on the speed level and pressure during use.

ACCESSORIES LISTING

  • Soft Round

  • Quad Tip

  • Fork

  • Hard Round

  • Bullet

  • Heated Flat Head

  • Extension Handle
    Accessories Listing

INSTRUCTIONAL VIDEO

  • Scan QR code with your phone’s camera.
    QR Code

  • Click link to watch, learn, and get relieved!

OPERATING INSTRUCTIONS

  1. Open the foldable arm by pushing the “Release” button (engraved and located on the side) and secure at one of the three desired arm positions.

  2. Select an attachment head of your choice Note the release button is not needed to switch out attachment heads Restate the Fork and Heated Head attachments for clarity from page 5.

  3. To attach the extension handle, remove the rubber stopper at the bottom of the R2 Pro
    and screw in the extension handle.

  4. Turn the R2 Pro ON
    a. Press and hold the power button for at least 2 seconds to turn on. Indicator light will turn on.
    b. Adjust the speed by pressing the power button up to 4 more times.

  5. Speeds 1 – 3 increase in intensity.

  6. Speed 4 (speed lights will oscillate) is a variable speed.

  * the harder you press, the more the speed will increase.  

c. When using the heated head attachment, adjust the temperature using the + or – to the right of the power button.

  1. Turning the R2 Pro OFF
    a. Press and hold the power button for 2 seconds to turn off We suggest putting the R2 Pro on the lowest speed before turning off.

Supplier’s Declaration Of Conformity

Supplier's Declaration Of Conformity

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference.
  2. this device must accept any interference received, including interference that may cause undesired operation.

FCC Instructions (47CFR 15.21)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC Instructions (47CFR 15.105)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

CUSTOMER SUPPORT

Symbols

@SHOPSONIX

SHOPSONIX.COM
Logo
Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals