wearpulse B0BZY7M2LQ Kids Oximeter Wearable Oxygen Monitor User Manual
- June 1, 2024
- Wearpulse
Table of Contents
Kids Oximeter
Wearable Oxygen Monitor
User Manual
B0BZY7M2LQ Kids Oximeter Wearable Oxygen Monitor
Download App
App name: ViHealth
iOS: App Store
Android: Google Play
http://qr.hotlnk.cn/79838280684
Notice: if you have installed the App before, please update it to the latest version.
Introduction
1.1 Intended use
This product is intended to be used for measuring, displaying and storing of
oxygen level (SpO2 ), heart rate of children (3-10 years old) in home or
healthcare facilities environment for sleep or daily use.
Notice:
It’s not a medical device. This device is for Sports and Aviation use only and
not intended for medical use.
1.2 Warnings and Cautions
- The Oximeter is not intended for medical use.
- The Oximeter is not an apnea monitor and should not be used for arrhythmia analysis.
- Do not self-diagnose or self-medicate on the basis of the measurements. Always consult your doctor.
- DO NOT squeeze the sensor part or apply excessive force on it.
- Do not use this device during MRI examination.
- Do not store the device in the following locations: locations in which the device is exposed to direct sunlight, high temperatures or levels of moisture, or heavy contamination; locations near to sources of water or fire; or locations that are subject to strong electromagnetic influences.
- Do not use the device in a combustible environment.
- Never submerge the device in water or other liquids.
- Do not clean the device with acetone or other volatile solutions.
- Do not drop this device or subject it to strong impact.
- The device and accessories are provided non-sterile
- Do not place this device in pressure vessels or gas sterilization device.
- Do not dismantle the device, as this could cause damage or malfunctions or impede the operation of the device.
- Consult your doctor immediately if you experience symptoms that could indicate acute disease.
- Do not self-diagnose or self-medicate on the basis of this device without consulting your doctor. Inparticular, do not start taking any new medication or change the type and/or dosage of any existingmedication without prior approval.
- Use only accessories specified in this manual.
- Prolonged continuous monitoring may increase the risk of undesirable changes in skin characteristics, such as irritation, reddening, blistering or burns.
- Do not open the device cover without authorization. The cover should only be opened by a qualified service personnel.
1.3 Guide to Symbols
Symbol | Description |
---|---|
Type BF-Applied Part | |
Manufacturer | |
Date of manufacture |
|
Follow Instructions for Use.
| MRI unsafe. Presents hazards in all MR environments as device contains
strongly ferromagnetic materials.
| Against ingress of solid foreign objects ≥12.5mm diameter, against dripping
(15° tilted)
| No alarm system
| Serial number
| Temperature limitation
| Humidity limitation
| Atmospheric pressure limitation
| Indicate separate collection for electrical and electronic equipment (WEEE).
| This product complies with the rules and regulations of the Federal
Communication Commission.
| Non-ionizing radiation
****| This product complies with verpackG.
1.4 Unpacking
- Device
- User Manual
- Data/Charging Cable
Overview
Using the Device and App
3.1 Charging
Charge the battery before using.
Connect the device to computer USB or USB charging adapter with USB cable.
After fully charged, the device will power off automatically.
3.2 POWER ON/OFF
POWER ON:
Wear the device, it will turn on automatically.
POWER OFF:
The device turns off automatically in a moment after you take it off.
3.3 Typical steps
- START. Charge the battery. Wear the device to power on.
- (Optional step) Monitor. In App Dashboard, you can monitor the real-time oxygen levels, heart rate and PI.
- STOP. Take off the device, the recording will be over after the countdown.
- DATA SYNC. After the countdown, run App to sync data. OR next time after you turn on the device, run App to sync.
3.4 Start working
- Wear the device on finger.
- Device will turn on automatically. After a few seconds, the device will begin to work.
To choose the wearing finger: all fingers can be used for wearing, from thumb to little finger. To get an accurate reading, the wearing should not be loose. For proper wearing, there should be no gap between the inner side of the ring and finger skin. ![wearpulse B0BZY7M2LQ Kids Oximeter Wearable Oxygen Monitor
-
finger skin](https://manuals.plus/wp-content/uploads/2024/04/wearpulse- B0BZY7M2LQ-Kids-Oximeter-Wearable-Oxygen-Monitor-finger-skin.jpg)(As a general recommendation, thumb or index finger may be a good choice for kids 3 to 7 years old; Middle finger, ring finger or little finger may be a better option for kids 5-10 years old. for reference only)
Notice:- Tight wearing is helpful for measurement, but may increase the risk of adverse effect to the skin. Always take close care of the skin condition during long-time wearing
- If the working time is less than 2 minutes, the data will not be saved.
- Please avoid excessive motion.
- Please avoid strong ambient light condition.
3.5 Check Pulse Signal Index(PI)
In App Dashboard, you can check the PI Bar (Pulse Signal Index), green
indicates good signal. If it’s orange or red, try to change a finger to get
better pulse signal (higher PI). Poor signal (low PI) may cause inaccurate
readings.
3.6 Stop working & sync data
Take off the device, the countdown will begin.
(If the working time is less than 2 minutes, there will be no countdown)
During the countdown, if you wear the device again, the record will be
resumed.
After the countdown, the data will have been saved in device and ready to
sync. Sync data:
- After the countdown, run App to sync data;
- OR next time after you turn on the device, run App to sync.
Notice: The built-in memory can store 4 sessions. The oldest will be
overwritten by the 5th. Please sync data to your phone in time.
3.7 Screen Wake up
The screen will go off automatically for saving power; you can touch the key
on top to wake up the screen.
3.8 Unavailable Symbol
When this symbol displays on device screen, it indicates the readings is
unavailable right now.
It may be caused by:
- Excessive movement;
- Poor signal, finger is too cold, PI is low;
Usually, the readings will recover in a few seconds when at rest.
3.9 How to Check Device Battery
Touch the key on top, you can switch display between readings and battery.
In App Dashboard, you can also check battery level.
3.10 Bluetooth Connection
The device Bluetooth will be enabled automatically after it’s turned on.
To establish a Bluetooth connection,
- keep the device Bluetooth enabled.
- Make sure the phone Bluetooth is enabled.
- Run the App.
Notice:
- DO NOT PAIR in the settings of your phone.
3.11 Add a New Device
For the initial use, you need to add a new device.
- Turn on device, run App, select
; - Touch the key on top of device.
3.12 Reminder in Device and App
There are two independent Reminders in device and App.
The Reminder will be activated when the oxygen level fall below the pre-set
value (Threshold).
3.13 Reminder in Device
You can configure it in App-Settings when your device is connected to App.
- You can switch on or off the reminder.
- You can adjust its volume.
- You can adjust the Threshold.
The reminder will stop when oxygen level recover, or you can press the key to
stop it.
3.14 Reminder in App Dashboard
You can configure it in App-Settings.
- You can switch on or off the reminder.
- You can adjust the Threshold.
The volume is same as your phone’s volume.
The Reminder works only when your phone stayed in Dashboard and not locked.
The Reminder in Dashboard will be activated when oxygen level fall below the
pre-set value (Threshold).
The Reminder will stop when the oxygen level recover. You can press the Mute
icon on Dashboard to mute.
3.15 View Report
In App- >History,
- Tap an item in the list, you can check the report, which includes analysis results and diagrams.
- Slide an item to left, you can delete it.
3.16 O2 Score
O2 Score is overall assessment of oxygen condition, which synthesizes the
frequency, depth and duration of oxygen shortage overnight. The range is 0-10
(10 is best). It is provided for each record in App.
Example:
3.17 App Offline Mode
If you enter App Offline Mode, you can view history data without connection.
3.18 Data of Multiple Devices
Enter Offline Mode. In App Settings->Select Device, you can select device if
you have multiple devices to check data of another device. In this Mode,
device is not connected so you cannot sync data or set device.
PC software
PC Software: O2 Insight Pro
Download from: https://iwearpulse.com/pages/softwaredownload Enter top menu:
Support- > Software download
Install the software on PC.
- Turn on device, connect the device to PC USB port with the supplied Data Cable (it’s different from universal USB cable)
- Run the PC software, click the Download button to download data from the device
With the PC software, you can view and print sleep report, which can also be
exported as PDF or CSV files.
Note: while the device is being connected to App, it can’t connect to PC
software.
Maintenance
5.1 Time & Date
After connection with App, device time will sync from your phone time
automatically.
5.2 Cleaning
Use a soft cloth moistened with water or alcohol to clean the device surface.
Troubleshooting
Problem | Possible Cause | Possible Solution |
---|---|---|
Device does not turn on or no response | Battery may be low. | Charge battery |
and try again.
Device might be damaged.| Please contact your local distributor.
Software exception| Keep device in charging, touch the key for 8 seconds.
The App cannot find the device| The Bluetooth of your phone is off.| Turn on
the Bluetooth in the phone.
The device Bluetooth is off.| Turn on device
For Android, Bluetooth cannot work without location permission| Allow location
access
Specifications
Environmental | Operating | Storage |
---|---|---|
Temperature | 5 to 40°C | -25 to 70°C |
Relative humidity (noncondensinq) | 10% to 95% | 10% to 95% |
Barometric | 700 to 1060hPa | 700 to 1060hPa |
Protection against electric shock | Internally powered equipment | |
Degree protection against electrical shock | Type BF | |
Electro-magnetic compatibility | Group I. Class B | |
Degree of dust & water resistance | IP22 | |
Weight | 12 g | |
Size | 38x30x27 mm | |
Battery | 3.7Vdc, Rechargeable Lithium-polymer | |
Charge time | 2-3 hours | |
Battery life | 14 hours for typical use | |
Wireless | Bluetooth 4.0 BLE | |
Oxygen level range | 70% to 99% | |
Oxygen level Accuracy (Arms) | 80-99%:±2%, 70-79%:±3% | |
Heart rate range | 30 to 250 bpm | |
Heart rate accuracy | ±2 bpm or ±2%. whichever is greater | |
Reminder source | Low oxygen level; | |
Recorded | Oxygen level, Heart rate, motion | |
parameters | ||
--- | --- | |
Data storage | 4 sessions, up to 10 hours for each | |
Mobile App for iOS | iOS 9.0 or above, iPhone 4s/ iPad 3 or above | |
Mobile App for android | Android 5.0 or above, with Bluetooth 4.0 BLE |
FCC Statement
FCC Warning:
FCC ID: 2ADXK-8326
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
Shenzhen Viatom Technology Co., Ltd.
4E, Building 3, Tingwei Industrial Park, No.6 Liufang
Road, Block 67, Xin’an Street, Baoan District, Shenzhen,
518101, Guangdong, China
Website: https://iwearpulse.com/ Product name: Pulse Oximeter
Version: A Date: March 28, 2023 PN: 255-06203-00
Model: PO4
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>