mityvac MV7300 Pneumatic Air Operated Fluid Evacuator Instruction Manual
- June 1, 2024
- mityvac
Table of Contents
mityvac MV7300 Pneumatic Air Operated Fluid Evacuator
Specifications
- Recommended Inlet Air Pressure: 80 – 120 psi (5.5 – 7 bar)
- Brake Bleeder
- 8.8-liter Reservoir Tank
- Dipstick Tubes
Product Usage Instructions
Draining Oil from Crankcase
- Park the vehicle on level ground, ensure the transmission is in neutral or park, and apply the parking brake.
- Start the engine and let it reach the normal operating temperature before turning it off.
- Remove the engine oil dipstick.
- Insert the smallest diameter dipstick tube into the dipstick hole until it reaches the bottom of the oil pan.
- Connect the main suction tube to the dipstick tube and insert the other end into the reservoir tank.
- Connect the air hose to the venturi at the base of the PneumatiVac.
- Extract oil until complete. If needed, empty the reservoir tank if the crankcase capacity exceeds 8 liters.
- Remove the main suction tube, pour oil into a container, and dispose of it properly. Clean the tank with solvent.
- Refill the crankcase to the desired level, run the engine briefly, and recheck the oil level.
Extracting and Dispensing Fluid into Transmission Cases and Differentials
- Follow steps 1-2 above.
- Remove the transmission fluid dipstick or fill plug (the vehicle may need to be jacked up).
- Use appropriate safety precautions when lifting the vehicle.
Frequently Asked Questions (FAQ):
Q: Can I use this product with gasoline?
- A: No, this product is not designed for use with gasoline.
Q: What fluids can be used with this equipment?
- A: Recommended fluids include Engine Oil, Gear and Transmission
- Oils, Power Steering Fluid, Coolants, Brake Fluid, and other compatible fluids.
Precautions
- This equipment is designed for servicing a variety of vehicles safely and conveniently. However, differences in engine blocks and dipstick configurations may make it impossible to use this equipment on every vehicle.
- The procedures documented in this manual are to serve as guidelines for the general use of this equipment.
- In addition to these guidelines, always follow the manufacturer’s recommended procedures when attempting to use this equipment on each unique vehicle.
- Do not attempt to force the tubes included with this equipment into a dipstick tube that will not readily accept the smaller of the two tubes.
- The tubes would appear to be too large and not designed to be used with the particular vehicle.
- Draining oil with this evacuator unit through the dipstick tube is expected to be straightforward. The instructions were written as a general guideline only.
- NOTE: DO NOT FORCE THE TUBE INTO ANY CRANKCASE AND MAKE SURE THAT YOU STOP PUSHING THE TUBE IN IF ANY FORCE IS RECOGNIZED. YOUR PARTICULAR DEALER SHOULD BE CONTACTED FOR DETAILS ON USING THIS EQUIPMENT TO EVACUATE OIL FROM YOUR CAR IF ISSUES ARISE.
- Always read carefully and understand instructions before using this equipment.
- Tighten lid-to-reservoir screws before first use and periodically to ensure proper seal.
Recommended Fluids:
- Engine Oil, Gear and Transmission Oils, Power Steering Fluid, Coolants, Brake Fluid and Other Fluids.
- Do not use gasoline.
Using the PneumatiVac away from a Compressed Air Source
- The PneumatiVac is equipped with an air control valve on the Venturi at the base of the unit and an in-line fluid shut-off valve on the hose assembly. This allows the unit to function away from the air source as follows:
- Once the compressed air source has been connected to the Venturi, open the air control valve and close the in-line fluid shut-off valve.
- Maintain a vacuum in the reservoir and then close the air control valve.
- Disconnect the PneumatiVac from the compressed air source and transport it to your job site.
- Open the in-line fluid shut-off valve and the vacuum stored in the reservoir will automatically suction out the fluid.
- When used in conjunction with the Mityvac® Fluid Evacuator Brake Bleeding Accessory Kit, PIN 07205, this tool can be used to vacuum bleed hydraulic brake systems.
- The reservoir tank of the Pneumativac is equipped with an automatic shut-off valve to prevent over-filling of the reservoir tank. As the fluid being evacuated flows into the reservoir tank it will raise the float.
- When the float reaches the shut-off valve, the flow of fluid being extracted will automatically stop.
Extracting and Dispensing Lubricants (General)
- (Motor oil, Gear Oil, Transmission Fluid, etc.)
Extracting and Dispensing Motor Oil into a Crankcase
- Park the vehicle on level ground, ensure the transmission of the vehicle is in the “neutral” or “park” position, and apply the parking brake.
- Start the engine. Allow the engine to idle until it reaches normal operating temperature. Once this is accomplished, turn the engine off.
- Remove the engine oil dipstick.
- Select and insert the smallest diameter dipstick tube into the dipstick hole until it reaches the bottom of the oil pan. Connect the main suction tube to the dipstick tube.
- Insert the opposite end of the main suction tube into the top of the reservoir tank.
- Connect the air hose to the venturi at the base of the PneumatiVac. This will require a male 1/4” NPT fitting (not included).
- Open the air valve thereby creating a vacuum inside the reservoir tank that will be used to extract the fluids.
- NOTE: Due to the varying fluid capacities of engines, it may be necessary to empty the fluid reservoir tank and restart the process if the crankcase capacity exceeds 8 liters.
- Once the oil has been extracted from the crankcase, remove the main suction tube from the reservoir tank; pour the oil from the tank into a suitable container, and properly dispose of the oil. Rinse out the reservoir tank with clean solvent or engine degreaser. Allow it to dry thoroughly.
- Refilled the crankcase to the desired level.
- Run the engine momentarily to circulate the new oil and then recheck the level to ensure that it is at the “full” mark.
Extracting and Dispensing Fluid into Transmission Cases and Differentials
- Follow Steps 1 & 2. (See Extracting and Dispensing Motor Oil into a Crankcase)
- Remove the transmission fluid dipstick or fill plug.
- In some applications, this may require jacking or lifting the vehicle. Use appropriate safety stands to avoid serious or fatal injury.
- Select and insert the appropriate diameter dipstick tube into the dipstick fill hole until it reaches the bottom of the transmission pan or gear case. Connect the main suction tube to the dipstick tube.
- Insert the opposite end of the main suction tube into the top of the reservoir tank.
- Connect air hose to the venturi at the base of the PneumatiVac. This will require a male 1/4” NPT fitting (not included).
- Open the air valve thereby creating a vacuum inside the reservoir tank that will be used to extract the fluids.
- Once the desired amount of fluid has been extracted, close the air control valve to stop the extraction process.
- Remove the main suction tube from the reservoir tank; pour the transmission fluid from the tank into a suitable container, and properly dispose of the transmission fluid. Rinse out the reservoir tank with clean solvent or engine degreaser. Allow it to dry thoroughly.
- Refill the transmission to the desired level.
- Run the engine until it reaches the operating temperature to circulate the new fluid and then re-check the level to ensure that it is full.
Extracting and Dispensing Coolant into a Cooling System
- Allow the engine to cool.
- Remove the radiator I expansion tank cap.
- Select the largest diameter dipstick tube and insert the tube into the radiator neck or expansion tank.
- Insert the opposite end of the main suction tube into the top of the reservoir tank.
- Connect the air hose to the venturi at the base of the PneumatiVac. This will require a male 1/4” NPT fitting (not included).
- Open the air valve thereby creating a vacuum inside the reservoir tank that will be used to extract the fluids.
- Once the desired amount of fluid has been extracted, close the air control valve to stop the extraction process.
- Remove the main suction tube from the reservoir tank; pour the fluid from the tank into a suitable container, and properly dispose of the fluid. Rinse out the reservoir tank with clean solvent or engine degreaser. Allow it to dry thoroughly.
- Refill the system to the desired level.
- Run the engine until it reaches the operating temperature to circulate the new fluid and then re-check the level to ensure that it is full.
Extracting Brake Fluid from the Master Cylinder
- Clean the exterior of the master cylinder and master cylinder cap. (This will prevent dirt from entering the master cylinder reservoir when the cap is removed.)
- Remove the lid of the master cylinder reservoir.
- Before inserting the extraction tube into the master cylinder reservoir, be sure that the extraction tube is clean and free of any other types of fluid.
- Failure to do so would result in contamination of the brake fluid in the hydraulic system and cause potential brake failure.
- Select the appropriate “dipstick” tube and connect it to the main suction tube.
- Insert the opposite end of the main suction tube into the top of the reservoir tank.
- Insert the end of the extraction tube into the master cylinder reservoir.
- Connect air hose to the venturi at the base of the PneumatiVac. This will require a male 1/4” NPT fitting (not included).
- Open the air valve thereby creating a vacuum inside the reservoir tank that will be used to extract the fluids.
- Once the brake fluid has been extracted, remove the main suction tube from the reservoir tank; pour the brake fluid from the tank into a suitable container, and dispose of it properly. Rinse out the reservoir tank with clean solvent or engine degreaser. Allow it to dry thoroughly.
- After all repairs are accomplished, refill the system with new, manufacturer-approved brake fluid from a sealed container.
MAXIMUM TEMPERATURE OF FLUIDS: 176° Fahrenheit, 80° Celsius
Bleeding Brakes
Instructions for Setup:
- Select the brake bleeding hose and connect one end to the in-line fluid shut-off valve. Connect the main connector to the reservoir tank and the universal bleeding elbow to the bleeder screw.
- Close the in-line fluid shut-off valve (the handle of the valve will be turned 90 degrees from the hose).
- Connect the air hose to the Venturi at the base of the PneumatiVac. This will require a male 3/4” NPT fitting that is used with your system (not included).
- Open the air shut-off valve thereby creating a vacuum inside the reservoir tank that will be used to bleed the brakes.
The following brake bleeding procedure is recommended:
- Ensure the master cylinder reservoir is full of the specified fluid and new dean fluid is available to top off the reservoir during the bleeding procedure. Ensure all bleeder fittings are clean at the start of the bleeding procedure.
- Bleed system in the following order:
- a. Master cylinder (if necessary). See the Bench Bleeding Procedure below if a new or rebuilt master cylinder is being installed.
- b. ABS controller (if necessary).
- c. Wheel cylinders and calipers in succession beginning with the wheel closest to the master cylinder and working to the farthest one.
- Place the wrench on the nut of the bleeder screw.
- Connect the brake bleeding adapter to the bleeder screw.
- Open the air shut-off valve by turning it to the “OPEN” position, thereby creating a vacuum required for bleeding.
- Open the bleeder screw slightly, only enough to cause fluid to flow into the bleeder hose and continue into the PneumatiVac™ (usually 1/4 to 1/2 turn).
- After evacuating, approximately 1/4 of the master cylinder reservoir capacity, tighten the bleeder screw. Add new brake fluid to the master cylinder so it remains full then proceed to the next wheel.
- NOTE: A tiny stream of bubbles may be noted in the bleeder hose after the bleeding procedure. This is caused by air seeping around the threads of the loosened bleeder screw and is drawn through the fitting by the suction created by the Fluid Evacuator.
- Once the air has been removed from the system, these tine air bubbles DO NOT jeopardize the bleeding operation since they are only present at the external surface of the feeder fitting and not in the system. If desired, bleeder fitting threads may be sealed with Teflon® tape to help eliminate this condition.
- NOTE: When finished using the PneumatiVac, contents should be emptied into an approved waste container. Rinse the reservoir with water, or solvent where applicable.
Bleeding Anti-Lock Brake Systems
- Always refer to the vehicle’s owner manual or the appropriate service manual for the manufacturer’s brake bleeding procedure.
- The front brakes on most anti-lock brake systems may be bled conventionally. Most hydraulic pump/pressure accumulator units are fitted with a bleeder valve, which must be bled when the system has lost fluid or is being replaced. Some vehicles require that the system be pressurized when the rear brakes are bled. Acura, Ford, and General Motors require a bleeding procedure, which uses specialized equipment.
Bench Bleeding System
- Whenever a master cylinder has been removed from a vehicle or a new one is being installed, the master cylinder must be bench-bled. Failure to bench bleed is the main reason for unsuccessful master cylinder replacement.
- Bench bleeding greatly decreases the chance that any air will be caught in the cylinder upon reinstallation.
- Most manufacturers include a bench bleeding kit with new or remanufactured master cylinders.
- If this kit was not included with the replacement part to be installed, consult with your retailer before installing the new or rebuilt master cylinder on the vehicle.
Item | Description | Part No. |
---|---|---|
1 | Brake Bleeding Adapter * | 822664 |
Consists of three adapters
Dimension
1 | Vacuum Tube Kit | 822599 | 5 | Kit Venturi** | 822647 |
---|---|---|---|---|---|
2 | Kit, Exhaust Muffler* | 822644 | 6 | Base Kit*** | 822574 |
3 | Kit, Control Valve | 822645 | 7 | Kit, Lid, and Float**** | 822648 |
4 | Kit, Tube, and Connectors | 822646 | 8 | Plastic Adapter | 822597 |
- Consists of three mufflers
- Consists of a venturi and connectors
- Consists of a base and foot bracket
- Consists of top and overfill float
Lincoln Industrial Standard Warranty
LIMITED WARRANTY
- Lincoln warrants the equipment manufactured and supplied by Lincoln to be free from defects in material and workmanship for one (1) year following the date of purchase, excluding therefrom any special, extended, or limited warranty published by Lincoln. If equipment is determined to be defective during this warranty period, it will be repaired or replaced, within Lincoln’s sole discretion, without charge.
- This warranty is conditioned upon the determination of a Lincoln authorized representative that the equipment is defective. To obtain repair or replacement, you must ship the equipment, transportation charges prepaid, with proof of purchase to a Lincoln Authorized Warranty and Service
- Center within the warranty period.
- This warranty is extended to the original retail purchaser only. This warranty does not apply to equipment damaged from accident, overload, abuse, misuse, negligence, faulty installation or abrasive or corrosive material, equipment that has been altered, or equipment repaired by anyone not authorized by Lincoln. This warranty applies only to equipment installed, operated, and maintained in strict accordance with the written specifications and recommendations provided by Lincoln or its authorized field personnel.
- THIS WARRANTY IS EXCLUSIVE AND IS INSTEAD OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
- TO, THE WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
- In no event shall Lincoln be liable for incidental or consequential damages. Lincoln’s liability for any claim for loss or damages arising out of the sale, resale, or use of any Lincoln equipment shall in no event exceed the purchase price. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, therefore the above limitation or exclusion may not apply to you.
- This warranty gives you specific legal rights. You may also have other rights that vary by jurisdiction.
- Customers not located in the Western Hemisphere or East Asia: Please contact Lincoln GmbH & Co. KG, Walldorf, Germany, for your warranty rights.
Lincoln Industrial Special Limited Warranties
- SPECIAL LIMITED 2-YEAR WARRANTY V Series, Single Injectors-85772, 85782, and Replacement Injectors-85771, 85781 Lincoln warrants the SL-V Injector series to be free from defects in material and workmanship for two (2) years following the date of purchase. If an injector model (single or replacement) is determined to be defective by Lincoln, in its sole discretion, during this warranty period, it will be repaired or replaced, at Lincoln’s discretion, without charge.
- SPECIAL LIMITED 5 YEAR WARRANTYSeries 20, 25, 40 Bare Pumps, PMV Bare Pumps, Heavy Duty and 94000 Series Bare Reels Lincoln warrants series 20, 25, 40 bare pumps, PMV bare pumps, Heavy Duty (82206), Mini Bench (81133, 81323), and 94000 LFR series (94100, 94300, 94500) bare reels to be free from defects in material and workmanship for five (5) years following the date of purchase.
- If equipment is determined by Lincoln, in its sole discretion, to be defective during the first year of the warranty period, it will be repaired or replaced at Lincoln’s discretion, without charge. In years two (2) and three (3), the warranty on this equipment is limited to repair with Lincoln paying parts and labor only. In years four (4) and five (5), the warranty on this equipment is limited to repair with Lincoln paying for parts only.
SPECIAL LIMITED 5-YEAR WARRANTYLFM
- Series Oil Meters (Lincoln Fluid Meter), LFV (Lincoln Fluid Valves), AOD (Air-Operated Diaphragm Pumps)- Lincoln warrants the LFM meter series (908/912 series), the Lincoln Fluid valve (708/712 series), and our AOD Pump offering to be free from defects in material and workmanship for five (5) years following the date of purchase. If either is determined to be defective by Lincoln, in its sole discretion, during the warranty period, they will be repaired or replaced, at Lincoln’s discretion, without charge.
- Lincoln Industrial Contact Information
- To find Lincoln Industrial’s Nearest Service Center
- Call one of the following numbers, you may also use our
Website
- Customer Service314-679-4200
- Websitelincolnindustrial.com
- Americas: One Lincoln Way
- St. Louis, MO 63120-1578
USA
- Phone +1.314.679.4200
- Fax +1.800.424.5359
- Asia/Pacific:
- 25 Int’l Business Park
- #01-65 German Centre
- Singapore 609916
- Phone +65.562.7960
- Fax +65.562.9967
- © Copyright Lincoln Industrial Corp. 2009
Printed in Taiwan
- Web site:www.lincolnindustrial.com
- Europe /Africa/Middle East
- Lincoln GmbH
- Heinrich-Hertz-Str. 2-8
- 69190 Walldorf – Germany
- Phone/Fax +49.6227.33-0/-259
- www.lincolnindustrial.de
Documents / Resources
|
mityvac MV7300 Pneumatic Air Operated Fluid
Evacuator
[pdf] Instruction Manual
MV7300 Pneumatic Air Operated Fluid Evacuator, MV7300, Pneumatic Air Operated
Fluid Evacuator, Air Operated Fluid Evacuator, Operated Fluid Evacuator, Fluid
Evacuator, Evacuator
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>