PERFORMANCE

Flow 2.9 ltr/min
Max tip 0.027”
MWP 207 bar | 3000 psi

SPECIFICATION

Motor 1300 watt
Weight 33.0 kg
Warranty 2 years

SUPPLIED COMPLETE WITH

TriTech T360 airless spray gun
TriTech Contractor 517
airless tip & guard
1/4” x 15m textile braided
hose assembly

No-tools quick-release wet end
Supplied Complete With

PRODUCT CODES

110 volt QT290-110
240 volt QT290-220

For some general advice on using QTech airless paint sprayers including the answer to many common FAQs take a look at  www.qtechspray.com/qtech-in- action/

Product Description

Product Description

Please read these instructions carefully before using the equipment

GENERAL SAFETY

WARNING! Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire and / or serious personal injury. The term airless sprayer in all of the warnings listed below refers to your mains-operated (corded) airless sprayer.

WORK AREA

  • Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
  • Do not operate airless sprayers in explosive atmospheres, such as in the presence of flammable liquid, gases, or dust. Airless sprayers create sparks which may ignite the dust or fumes.
  • Keep bystanders, children, and visitors away while operating a airless sprayer. Distractions can cause you to lose control.

ELECTRICAL SAFETY

  • Airless sprayer plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) airless sprayers.
    Unmodified plugs and matching outlets will reduce the risk of electric shock. Grounded sprayers must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adaptor plugs. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. If the sprayer should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user.

  • Avoid body contact with grounded surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.

  • Do not expose airless sprayers to rain or wet conditions. Water entering an airless sprayer will increase the risk of electric shock.

  • Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the airless sprayer. Keep the cord away from heat, oil, sharp edges or moving parts. Replace damaged cords immediately. Damaged or entangled cords increase the risk of electric shock.

  • When operating an airless sprayer outdoors, use an outdoor extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.

PERSONAL SAFETY

  • Stay alert, watch what you are doing and use common sense when operating an airless sprayer. Do not use while you are tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating airless sprayers may result in serious personal injury.
  • Use safety equipment. Always wear eye protection. Safety equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries.
  • Avoid accidental starting. Ensure the switch is in the off position before plugging in.
  • Do not overreach. Keep a proper footing and balance at all times. This enables better control of the airless sprayer in unexpected situations.
  • Dress properly. Do not wear loose clothing or jewelry. Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.

SERVICE

  • Have your airless sprayer serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the airless sprayer is maintained. If the supply cord of this airless sprayer is damaged it must be replaced by a specially prepared cord available through the service organization.

PRESSURE RELIEF PROCEDURE

IMPORTANT! To avoid possible serious body injury, always follow this procedure whenever the sprayer is shut off, when checking it, when installing, changing or cleaning tips and whenever you stop spraying.

  1. Engage the gun safety latch.
  2. Turn the unit off and unplug it from the electrical outlet.
  3. Disengage the gun safety latch and trigger the gun to relieve residual fluid pressure. Hold metal part of the gun in contact with grounded metal pail.
  4. Turn the Priming Valve to the open (priming) position to relieve residual fluid pressure.
  5. Re-engage gun safety latch and close Priming Valve. If the SPRAY TIP OR HOSE IS CLOGGED, follow Step 1 through 5 above. Expect paint splashing into the bucket while relieving pressure during Step 4.

SPECIFIC SAFETY RULES

HANDLE THIS UNIT AS YOU WOULD A LOADED WEAPON!
Extreme high pressure spray can cause extremely serious injury.
OBSERVE ALL WARNINGS
WARNING: HIGH PRESSURE Never leave pressurized system unattended. Always follow the PRESSURE RELIEF PROCEDURE. Take precautions to avoid high pressure component rupture.
DANGER: INJECTION INJURY
Skin injection by high pressure paint is not a simple cut. It must be treated surgically immediately.
WARNING: FIRE AND EXPLOSION HAZARD
Take all precautions to avoid sources of sparks and ignition when spraying.
Keep the machine at least 6 meters away from the spraying operation.
WEAR PROTECTIVE EQUIPMENT AT ALL TIMES
Always use a respirator, eye protection and protective clothing. Keep clear of moving parts when starting or operating the sprayer. Do not put your fingers into any openings to avoid amputation by moving parts or burns on hot parts.
When starting the motor, maintain a safe distance from moving parts of the equipment. Before adjusting or servicing any mechanical part of the sprayer, follow the PRESSURE RELIEF PROCEDURE.
EXPLOSION RISK FROM HALOGENATED HYDROCARBON SOLVENTS
Never use halogenated hydrocarbon solvents in this machine.
Contact with aluminum parts may cause an explosion.
Some of the most common of these solvents are:
Carbon Tetrachloride
Chlorobenzene
Dichloroethane
Dichloroethyl Ether
Ethyl Bromide
Ethyl Chloride
Tetrachloroethane

PREVENT STATIC SPARKING FIRE/EXPLOSIONS

Vapors created when spraying can be ignited by sparks.
To reduce the risk of fire, always locate the sprayer at least 20 feet (6 m.) away from spray area. Do not plug in or unplug any electrical cords in the spray area.
Doing so can cause sparks which can ignite any vapors still in the air. Follow the coating & solvent manufacturers safety warnings and precautions.

MEDICAL ALERT INJECTION INJURIES

If any fluid appears to penetrate your skin, GET EMERGENCY MEDICAL CARE AT ONCE. DO NOT TREAT AS AN ORDINARY CUT. High pressure fluids from spray or leaks are powerful enough to easily penetrate the skin and cause extremely serious injection injury, leading to the possible need for amputation.

  • NEVER point the spray gun at anyone or any part of the body.
  • NEVER put your hand or fingers over the spray tip. Do not use a rag or any other materials over your fingers. Paint will penetrate through these materials and into the hand.
  • NEVER try to stop or deflect leaks with your hand or body.
  • ALWAYS have the tip guard in place when spraying.
  • ALWAYS lock the gun trigger when you stop spraying.
  • ALWAYS remove tip from the gun to clean it.
  • NEVER try to “blow back” paint, this is not an air powered sprayer.
  • ALWAYS follow the PRESSURE RELIEF PROCEDURE before cleaning or removing the spray tip or servicing any system equipment.
  • Be sure the equipment safety devices are operating properly before each use.
  • Tighten all of the fluid connections before each use.
  • NEVER alter equipment in any manner.
  • NEVER smoke while in spraying area.
  • NEVER spray highly flammable materials.
  • NEVER use around children.
  • NEVER allow another person to use sprayer unless he is thoroughly instructed on its safe use and given this operator’s manual to read.
  • ALWAYS wear a spray mask, gloves and protective eye wear while spraying.
  • ALWAYS ensure fire extinguishing equipment is readily available and properly maintained.

NEVER LEAVE SPRAYER UNATTENDED WITH PRESSURE IN THE SYSTEM.
FOLLOW PRESSURE RELIEF PROCEDURES AT ALL TIMES.

ALWAYS INSPECT SPRAYING AREA

  • Keep the spraying area free from obstructions.
  • Make sure the spraying area has good ventilation to safely remove vapors and mists.
  • NEVER keep flammable material in spraying area.
  • NEVER spray in vicinity of open flame or other sources of ignition.
  • The spraying area must be at least 6 metres away from spray unit.

SPRAY GUN SAFETY

  • ALWAYS set gun safety lock in the “LOCKED” position when not in use and before servicing or cleaning.
  • NEVER remove or modify any part of the gun.
  • ALWAYS REMOVE THE SPRAY TIP when cleaning. Flush unit at the LOWEST POSSIBLE PRESSURE.
  • ALWAYS check operation of all gun safety devices before each use.
  • Be very careful when removing the spray tip or hose from the gun. A plugged line will contain fluid under pressure. If the tip or line is plugged, follow the PRESSURE RELIEF PROCEDURE

TIP GUARD

  • ALWAYS have the tip guard in place on the spray gun while spraying. The tip guard alerts you to the injection hazard and helps prevent accidentally placing your fingers or any part of your body close to the spray tip.

SPRAY TIP SAFETY

  • Use extreme caution when cleaning or changing spray tips. If the spray tip clogs while spraying, engage the gun safety latch immediately. ALWAYS follow the PRESSURE RELIEF PROCEDURE and then remove the spray tip to clean it.
  • NEVER wipe off build up around the spray tip.

TOXIC FLUID HAZARD

  • ALWAYS remove tip guard & tip to clean AFTER pump is turned off and the pressure is relieved by following the PRESSURE RELIEF PROCEDURE.
  • Hazardous fluid or toxic fumes can cause serious injury or death if splashed in eyes or on skin, inhaled or swallowed. Know the hazards of the fluid you are using. Store and dispose of hazardous fluid according to manufacturer, local, state and national guidelines.
  • ALWAYS wear protective eyewear, gloves, clothing and respirator as recommended by fluid manufacturer.

HOSES

  • Tighten all of the fluid connections securely before each use. High pressure fluid can dislodge a loose coupling or allow high pressure spray to be emitted from the coupling and result in an injection injury or serious bodily injury.
  • Only use hoses with a spring guard. The spring guard helps protect the hose from kinks or other damage which could result in hose rupture and cause an injection injury. Do not allow kinking or crushing of hoses or allow it to vibrate against rough, sharp or hot surfaces.
  • Use only conductive fluid hoses for airless applications. Be sure the gun is grounded through the hose connections. Use only high pressure airless hoses with static wire which are approved for 3000 psi.
  • NEVER use a damaged hose, which can result in hose failure or rupture and cause an injection injury or other serious bodily injury or property damage. Before each use, check entire hose for cuts, leaks, abrasions, bulging of the cover, or damage or movement of couplings. If any of these conditions exist, replace the hose immediately.
  • NEVER use tape or any device to try to mend the hose as it cannot contain the high pressure fluid. NEVER ATTEMPT TO RECOUPLE THE HOSE. It is not possible to recouple a high pressure hose .

GROUNDING

  • Ground the sprayer and other components in the system to reduce the risk of static sparking, fire or explosion which can result in serious bodily injury and property damage. For detailed instructions on how to ground, check your local electrical code.
  • ALWAYS ensure switch is in OFF position before plugging unit in.

Always ground all of these components:

  1. Sprayer: plug the power supply cord, or extension cord, each equipped with an undamaged three-prong plug, into a properly grounded outlet. DO NOT USE AN ADAPTER. Use only a 3 wire extension cord that has a grounding plug, and a receptacle that will accept the grounding plug on the product. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. If in doubt, use the next heavier gauge.
  2. Fluid hose: use only grounded hoses.
  3. Spray gun or dispensing valve: grounding is obtained through connection to a properly grounded fluid hose and pump.
  4. All solvent pails must be conductive metal material and properly grounded. Do not place on a non conductive insulating surface unless a ground wire is added to a true earth such as a metal water pipe. ALWAYS ensure fire extinguishing equipment is readily available and properly maintained.

FLUSHING SAFETY

WHEN SPRAYING & CLEANING WITH FLAMMABLE PAINTS AND THINNERS

  1. When spraying with flammable liquids, the unit must be located a minimum of 25 feet away from the spraying area in a well ventilated area. Ventilation must be sufficient enough to prevent the accumulation of vapors.
  2. To eliminate electrostatic discharge, ground the spray unit, paint bucket and spraying object. See GROUNDING. Use only high pressure airless hoses approved for 3000 psi which is conductive.
  3. Remove the spray tip before flushing. Hold the metal part of the gun firmly to the side of a metal pail & use the lowest possible fluid pressure during flushing.
  4. Never use high pressure in the cleaning process. USE MINIMUM PRESSURE.
  5. Do not smoke in spraying/cleaning area. NEVER use cleaning solvents with flash points below 60°C/140°F. Some of these are: acetone, benzene, ether, gasoline, naphtha. Consult your supplier if in doubt.

ASSEMBLY

  1. Attach the hose to the pump and tighten with a wrench.
  2. Attach the hose to the gun and tighten with a wrench.

OPERATION

  1. New sprayer / before you start
    Your sprayer was factory tested in an oil solution which was left in the pump. Before using oil-base paint, flush with pump conditioner only. Before using water-base paint flush with pump conditioner, followed by soapy water, then a clean water flush.

  2. Changing colours
    Flush with a compatible solvent such as pump conditioner or water.

  3. Changing from water-base to oil-base paint
    Flush with soapy water, and then pump conditioner.

FLUSHING

WHEN TO FLUSH

  1. Cleanup (for further detail turn to page 20).

  2. Changing from oil-base to water base paint. Flush with pump conditioner, followed by soapy water, then a clean water flush.

  3. Storage. Always relieve pressure (see PRESSURE RELIEF PROCEDURE page 8) prior to storage or when machine is unattended.
    Oil-base paint: Flush with pump conditioner. Ensure that there is no pressure in the unit, then close the priming valve.
    Water-base paint: Flush with water, and then pump conditioner. For longer term storage fill with pump conditioner.
    Always ensure that there is no pressure in the unit, and close the prime/ pressure relief valve for storage.

  4. Start-up after storage. Before using water-base paint, flush with soapy water and then with clean water. When using oil-base paint, flush out the pump conditioner with the material to be sprayed.

HOW TO FLUSH

  1. Be sure the gun safety latch is engaged and there is no spray tip in the gun.
  2. Pour enough clean, compatible solvent into a large, empty metal pail to fill the pump and hoses.
  3. Place the suction tube into the pail.
  4. Turn the Priming Valve to the ‘Open’, priming position.
  5. Point the gun into the metal pail and hold a metal part of the gun firmly against the pail. To reduce the risk of static sparking which can cause fire or explosion, always hold a metal part of the gun firmly against the metal pail when flushing. This also reduces splashing. Disengage the gun safety latch and squeeze the gun trigger. Turn the ON/OFF Toggle Switch to the “ON” position and turn Pressure Control Knob clockwise to increase pressure just enough to start the pump.
  6. Close the priming valve. This will allow solvent to be flushed through the pump, hoses and gun. Allow the unit to operate until clean solvent comes from the gun.
  7. Release the trigger and engage the gun safety latch.
  8. Whenever you shut off the sprayer, follow the PRESSURE RELIEF PROCEDURE.

SPRAYING

  1. Connect the hose and gun.

  2. Check the electrical service. Be sure the electrical service matches the rating on the machine’s nameplate and that the outlet you use is properly grounded.

  3. Fill the packing nut/wet cup with a few drops of QLube Piston Lubricant.

  4. Flush the sprayer
    a Prepare the media to be sprayed according to the material manufacturer’s recommendations.
    b Place the suction tube into the media container.
    c Prime Valve must be ‘Open’ in the priming position.
    d When you have ensured that the gun safety latch is engaged, attach tip  and safety guard
    e Turn the power switch to the ‘On’ position.
    f Allow the pump to prime. After the pump is primed, immediately turn the Prime Valve to the ‘Closed’ position.
    g Turn Pressure Control Knob to the desired spray pressure.
    h Disengage the gun safety latch and you are ready to spray.

  5. Adjusting the pressure
    a Turn the Pressure Control Knob clockwise to increase pressure and counterclockwise to decrease pressure.
    b Always use the lowest pressure necessary to completely atomize the material. Note: Operating the sprayer at higher pressure than needed, wastes material, causes early tip wear, and shortens sprayer life. It will also result in the motor cycling on and off to maintain pressure. This cycling will result in poor and inconsistent spraying results
    c If more coverage is needed, use a larger tip rather than increasing the pressure.
    d Check the spray pattern. The tip size and angle determines the pattern width and flow rate. Spray a test pattern and then adjust the pressure to eliminate heavy edges. Use a smaller tip size if the pressure adjustment cannot eliminate heavy edges.
    e While spraying, hold the gun perpendicular, about 25-30cm (10-12 inches) away from the surface. Spray back and forth. Trigger the gun before moving and release the trigger after each stroke. Overlap by 50%.
    WARNING
    When you spray into the paint bucket, always use the lowest spray pressure and maintain firm metal to metal contact between gun and container. To stop the unit in an emergency, turn the motor off. Then relieve the fluid pressure in the pump and hose as instructed in the ‘Pressure Relief Procedure’.
    WARNING
    Follow the PRESSURE RELIEF PROCEDURE. To reduce the risk of injection, never hold your hand, body, fingers or hand in a rag in front of the spray tip when cleaning or checking for a cleared tip. Always point the gun toward the ground or into a waste container when checking to see if the tip is cleared or when using a self cleaning tip.

  6. Shutting off the sprayer
    a Whenever you stop spraying, even for a short break, follow the PRESSURE
    RELIEF PROCEDURE
    b Flush the sprayer at the end of each work day, if the material you are spraying is water-based, or if it could harden in the sprayer overnight. Refer to FLUSHING on page 15 for more detail. Use a compatible solvent to flush, and then fill the pump and hoses with an oil based solvent such as QTector pump conditioner.

SPRAY GUN

Attach spray gun to airless unit and tighten fittings securely. Set the gun safety latch. The gun safety latch should always be set when the gun is not being triggered. Read all warnings and safety precautions supplied with the spray gun and in product manual.

SPRAY TIP ASSEMBLY

  1. Be sure PRESSURE RELIEF PROCEDURE is followed before assembling tip and housing to the gun.
  2. Lock gun safety latch.
  3. Insert Tip into the guard housing assembly.
  4. Guide metal seat into guard housing assembly through retaining nut and turn until it seats against the cylinder.
  5. Insert O-Ring gasket on metal seat so it fits in the grooves.
  6. Finger tighten guard housing retaining nut onto the gun.
  7. Turn guard in the desired position.
  8. Completely tighten the retaining nut
    Spray Tip Assembly

TO REMOVE CLOGS FROM SPRAY TIP

  1. Lock gun safety latch.
  2. Turn tip handle 180 degrees.
  3. Disengage trigger lock & trigger gun into pail.
  4. If the tip handle appears locked loosen the retaining nut. The handle will now turn easily.
  5. Engage gun safety latch and return handle to the spray position.

CLEANING GUN HANDLE FILTER

Immediately after the work is finished, flush the gun out with a solvent. Brush pins with solvent and oil them lightly so they will not collect dried paint. To clean the filter, use a brush dipped in an appropriate solvent. Change or clean filters at least once a day. Some types of latex may require a filter change after about four hours of operation.

SPRAY TIP SELECTION

Spray tip selection is based on paint viscosity, paint type, and job needs. Generally, use a smaller tip for light viscosities (thin paints), and use a larger tip for heavier viscosities (thicker paints). Spray tip size is based on how many litres of paint per minute can be sprayed through the tip. Do not use a tip larger than the maximum pump flow rate or capacity the sprayer can accommodate. Pump flow rate is measured in litres per minute (LPM).

PATTERN WIDTH

Two tips having the same tip size, but different pattern widths will deliver the same amount of paint over a different area (wider or narrower strip). A spray tip with a narrow pattern width makes it easy to spray in tight places. Thickness of the paint coat per stroke is determined by spray tip “fan width”, rate of the spray gun movement, and distance to surface.

SPRAY TIP REPLACEMENT

During use, especially with latex paint, high pressure will cause the orifice to grow larger. This destroys the pattern. Replace tips before they become excessively worn. Worn tips waste paint, cause overspray, make cutting-in difficult, and decrease sprayer performance. If the tip is the maximum rated size, when it wears, it will exceed the flow rate capacity of the sprayer. If when using maximum capacity tip size the pump cannot keep up, then you know that the tip is worn beyond capacity.

CLEANUP PROCEDURE

  1. Perform pressure relief procedure.
  2. Place pickup tube in a bucket of flushing fluid. (Use water for water base paint and pump conditioner for oil base paint).
  3. Turn the power on. Close priming valve.
  4. Increase pressure to half. Hold the gun against the paint pail. Take off the trigger safety. Trigger the gun until flushing fluid appears.
  5. Move the gun to a waste pail. While holding the gun against the pail, trigger the gun to thoroughly flush the system. Release the trigger and put the trigger safety on.
  6. Open the priming valve and allow the flushing fluid to circulate for 15 seconds (to clean the drain tube).
  7. Raise the pickup tube out of the flushing fluid and run the sprayer for 20-30 seconds to drain the fluid.
  8. Close the priming valve. Trigger the gun into flushing pail to purge the hose.
  9. Turn the power off.
  10. Open the priming valve.
  11. Unplug the sprayer.
  12. Remove the filters from the pump and gun. Clean and replace.
  13. If flushing was with water, flush again with pump conditioner to prevent corrosion inside the pump. (For long term storage, mix motor oil into the spirits).
  14. Clean the exterior of the sprayer with rag soaked in pump conditioner

DAILY MAINTENANCE

  1. Keep the displacement pump packing nut/wet cup lubricated with QLube Piston Lubricant at all times. Add a drop of oil with regular use to the top of the pump. This helps protect the rod and the packings.
  2. Inspect the packing nut daily. If seepage of paint into the packing nut and/or movement of the piston upward is found (while not spraying), the packing nut should be tightened enough to stop leakage only, but not any tighter. Over tightening will damage the packings and reduce the packing life.

PACKINGS

The packings are a wearing part. If the pump can no longer maintain pressure, has difficulty priming and paint seeps into the throat of the pump, and tightening the packing nut no longer helps, then the packings will require replacement. This is best entrusted to a qualified repair technician.

To remove the pump and replace the packings, follow the instructions below:

PUMP REMOVAL

  1. Remove the high pressure hose (104) from the back of the pump housing.
  2. Using a spanner remove pressure sensor (105) from the pump housing.
  3. Loosen the gland nut (2) and remove the pickup tube (3) from the bottom of the pump. At the same time remove O-ring (5), check ball (6) & ball guide (7).
  4. Turn the pump until the piston is at its lowest point. This will allow the snapring (23) to be removed. This in turn will allow you to push out the piston wrist pin (25).
  5. Unscrew the fluid pump section.
  6. Replacement is the reverse of removal. Grease the exposed portion of the piston and wrist pin when assembling.

PACKINGS REPLACEMENT

  1. Loosen the packing nut with the packing bar provided and remove.
  2. Push out the piston through the bottom.
  3. Remove all parts and clean. Clamp the piston and in the bottom of the piston, remove the socket set screw (13) to allow removal of the small ball seat (15), and check ball (16).
  4. Discard all old packings.
  5. Soak the new leather packings in W30 oil for at least one hour before assembling.
  6.  Replace the packings, glands, O-rings and check balls with the new parts from the rebuild kit. Strictly follow the exact order and orientation.
  7. Thread the packing nut loosely. Push the piston up through the pump fluid section. Tighten the packing nut until resistance from the disc springs is felt. Tighten a further 3/4 turn but be careful. Do not over tighten.

Fluid Pump

Suction Filter Quick reference
MESH/THREAD PRODUCT CODE
15 mesh / 1/2” thread QF0535015B
30 mesh / 1/2” thread QF0535030B

Included in Packing Kit 12-002

Fluid Pump

ITEM PRODUCT CODE DESCRIPTION QTY
01 Quick ref table SUCTION FILTER/INLET STRAINER 1
02 12-290-001 GLAND NUT 1
03 12-290-002 SUCTION TUBE (Ø12 x Ø22 x 315MM) 1
04 12-290-003 TUBE HOLDER (Ø11/Ø22) 2
05 12-005* O-RING (Ø28.4xØ35.3×3.5) 1
06 12-006* LOWER CHECK BALL (Ø12.7) 1
07 12-007 BALL GUIDE/CAGE 1
08 12-290-010 PUMP HOUSING 1
09 12-003 OUTPUT NIPPLE (PT 1/4″ x 1/4″-19PF) 1
10 12-290-011 RETAINING NUT 1
11 12-002 COMPLETE PACKING KIT, INC PARTS 05,06,11,14,16,19,20 1
12 12-008 PACKING SPACER 1
13 12-015 BALL SEAT FASTENER (M16xP1.0) 1
14 12-011* O-RING (Ø9 x Ø13 x 2) 1
15 12-010 BALL SEAT (Ø4xØ13.8×4) 1
16 12-012* UPPER CHECK BALL (Ø6.35) 1
17 12-290-022 DISPLACEMENT PISTON 1
18 12-009 DISC SPRING (Ø18xØ34.7×1) 3
19 12-013* O-RING (Ø31.2xØ35.1×1.8) 1
20 12-014* O-RING 1
21 12-019 SEAL SEAT (Ø27xØ35) 1
22 12-018 PACKING NUT (M38xP1.5) 1
23 12-290-032 RETAINING RING (Ø1.2xØ24.8) 1
24 12-290-034 DRIVE WRIST PIN (Ø16×32) 1
25 12-290-033 PUMP WRIST PIN (Ø9.5×25) 1
26 12-290-035 DRIVE PISTON 1
27 12-290-038 INTERNAL CIRCLIP 1
28 12-290-039 BUSHING (Ø38xØ44×43) 1

Motor & Gearbox

Motor & Gearbox

ITEM PRODUCT CODE DESCRIPTION QTY
41 12-290-032 RETAINING RING (Ø1.2xØ24.8) 1
42 12-290-034 DRIVE WRIST PIN (Ø16×32) 1
43 12-290-033 PUMP WRIST PIN (Ø9.5×25) 1
44 12-290-035 DRIVE PISTON 1
45 12-290-038 INTERNAL CIRCLIP 1
46 12-290-039 BUSHING (Ø38xØ44×43) 1
47 12-290-051 SOCKET CAP SCREW (M5x35xP0.8) 6
48 12-290-050 GEAR HOUSING 1
49 12-290-053 BALL BEARING 1
50 12-290-054 TRUSS HEAD MACHINE SCREW (M5x8xP0.8) 2
51 12-290-055 CONNECTING ROD 1
52 12-290-056 NEEDLE BEARING 1
53 12-290-057 CRANK GEAR 1
54 12-290-060 BALL BEARING 1
55-1 12-290-062-1 MOTOR UNIT (110V) 1
55-2 12-290-062-2 MOTOR UNIT (220V) 1
56 12-290-061 SOCKET CAP SCREW (M5x12xP0.8) 4
57 12-290-064 BRUSH CAP (8×16) 2
58 12-290-065 CARBON BRUSH (8×16) 2
59 12-290-068 HOUSING COVER 1
60 12-290-069 SOCKET CAP SCREW (M5x55xP0.8) 4

Control Box

Control Box

ITEM PRODUCT CODE DESCRIPTION QTY
70-1 12-290-091-1 ELECTRONICS UNIT (110V) 1
70-2 12-290-091-2 ELECTRONICS UNIT (220V) 1
71 12-290-121 RUBBER PROTECTION GUARD 2
73 12-290-101 PANHEAD TAPPING SCREW-B (M4x12) 4
74 12-290-097 EARTHING MARKING 1
75 12-290-096 PANHEAD MACHINE SCREW (M4x10xP0.7) 1
76 12-290-093 SOCKET CAP SCREW (M4x12xP0.7) 6
77 12-290-090 CONTROL BOX 1
78 12-290-094 U-BRACKET 2
79 12-290-092 HEX NUT (M4xP0.8) 6
80 12-290-100 CURRENT PROTECTOR 1
81 12-290-120 SPEED CONTROL (110V&220V) 1
82 12-290-119 SOCKET SET SCREW (M4x8xP0.7) 1
83 12-290-118 SUCTION POWER CONTROL DIAL (BLACK) 1
84 12-290-115 POWER SWITCH (110V&220V) 1
85 12-290-110 WIRE LEAD 1
86 12-290-111 WIRE LEAD 2
87 12-290-108 HEX NUT (M3) 2
88 12-290-107 LCD DISPLAY 1
89 12-290-106 WINDOW 1
90 12-290-105 TRUSS HEAD MACHINE SCREW (M3x12xP0.5) 2
91 12-290-117 CABLE GLAND 1
92 12-290-116 CABLE GLAND 1
93 12-290-125 POWER SUPPLY CABLE 1

Fluid Manifold

Manifold Filter Quick reference
MESH/COLOUR CODE
30 mesh / grey QF0571030
60 mesh / black QF0571060
100 mesh / blue QF0571100

Fluid Manifold

ITEM PRODUCT CODE DESCRIPTION QTY
101 Quick ref table MANIFOLD FILTER 1
102 12-290-070 FILTER CAP 1
103 12-001 PACKING NUT TOMMY BAR 1
104 12-290-085 HIGH PRESSURE HOSE (1/4″-18UNF) 1
105 12-290-074 PRESSURE TRANSDUCER (110V&220V) 1
106 12-003 OUTPUT NIPPLE (PT 1/4″ x 1/4″-19PF) 2
107 12-290-071 FILTER HOUSING 1
108 12-290-075 PRIMING VALVE 1
109 12-016 DRAIN TUBE (PT1/8″x0.45M) 1
110 12-290-078 SOCKET SET SCREW (PT1/4′) 1
111 12-290-079 HEX NUT (M5-P0.8) 4
112 12-290-080 BRACKET 1

Frame

Frame

ITEM PRODUCT CODE DESCRIPTION QTY
120 12-290-160 END CAP 2
121 12-290-153 HEX BOLT (M6x16xP1.0) 2
122 12-290-152 FLAT WASHER (Ø1/4xØ32×2) 2
123 12-290-154 WHEEL 2
124 12-290-155 EXTERNAL CIRCLIP (S-19) 2
125 12-290-156 FRAME 1
126 12-290-157 FLAT HEAD MACHINE SCREW (M4x5xP0.7) 4
127 12-290-158 HANDLE MOUNT 2
128 12-290-159 ROLL PIN (Ø5×25) 2
129 12-290-161 HANDLE 1

Wiring Diagram

Wiring Diagram

Quick Check

The information on this page is intended only as a quick guide. It is no way intended as a substitute to the information on the pages following, which the user should be fully acquainted with before using an electric airless sprayer

SYMPTOM CHECK OUT PROCEDURE
Motor won’t run Power switch Check it’s on.
Pressure control knob Supply plug & cable Turn pressure control knob

clockwise to increase pressure

Check plug & cable for loose connections and/or damage

Pump does not cycle| Digital display| Check for error codes , if any showing contact a

QTech dealer or technician for advice

Pump won’t prime| Prime valve|  Make sure it’s in the prime position Open prime valve and purge air from pump Ensure it’s not clogged, clean where necessary Tighten if loose Tap the suction tube connection a few times to loosen – if no result check that lower ball and/or seat is not worn or scarred Change packings ; contact aQTech dealer or technician for advice
Air in paint Suction filter

Suction tube

Lower ball   Pump leaking paint
Insufficient pressure at the gun or sudden loss of pressure| Paint bucket Spray tip   Filters Coating being sprayed   Hose  Prime valve| Check not empty If clogged, reverse tip , aim gun at scrap and pull trigger to clear Check tip for wear, replace where necessary Check all filters are clear of debris, clean or replace Ensure OK for coating/tip combination, change if necessary Check OK for spray, thin where appropriate Check length & diameter compatible with pump & coating Check not obstructed with debris, contact a QTech dealer or technician for advice
Bad quality spray pattern| Pressure setting| Increase pressure If clogged, reverse tip , aim gun at scrap and pull trigger to clear Check tip for wear, replace where necessary Too thick Move gun faster, check far enough away from surface and tip size Too thin Move gun slower, check close enough to surface and tip size Check pressure control for wear, contact a QTech dealer or technician for advice
Spray tip
Coating
Uneven spray

Error Codes

ERROR CODE| CAUSE| EFFECT| RETURN TO OPERATION| SOLUTION
---|---|---|---|---
E1| ** Overload (Peak current above 30A for 0.2 seconds or more)| Motor stops| Restart machine by turning the switch OFF, then ON again.| Also check for overtightened packings
E11| Overload (Average current above 30A)| Motor stops| Restart machine by turning the switch OFF, then ON again.| Also check for overtightened packings
E21| Abnormal offset in current detection circuit of the electronics board| Motor stops| Replace electronics board| Replace electronics board
E5| Pressure sensing abnormality or no signal from sensor| Motor stops| When pressure signal is normal, will automatically return to operation| Check pressure transducer and check for bad connections with transducer, LCD or PC board
E61| Voltage below minimum (110V models: under 90V at rest, under 70V while running) (220V models: under 200V at rest, under 180V while running)| Motor stops| When voltage is normal, will automatically return to operation| Check voltage supply
E62| Voltage above maximum (110V models: over 130V) (220V models: over 260V)| Motor stops| When voltage is normal, will automatically return to operation| Check voltage supply
ERROR CODE| CAUSE| EFFECT| RETURN TO OPERATION| SOLUTION
---|---|---|---|---
E8| Short circuit on power board or motor open circuit| Motor stops| Try to restart machine by turning the switch OFF, then ON again| If the problem persists, bring the unit to an authorized service center for repair
E9| Maximum pressure exceeded| Motor stops| When pressure signal is normal, will automatically return to operation| Check pressure transducer
__
E91| Loss of signal from the electronics board to the LCD module during operation| Motor stops| Try to restart machine by turning the switch OFF, then ON again| If the problem persists, bring the unit to an authorized service center for repair
E92| Loss of signal from the LCD module to the electronics board during operation| Motor stops| Try to restart machine by turning the switch OFF, then ON again| If the problem persists, bring the unit to an authorized service center for repair
8888**| The power transmission panel cannot receive the signal from the power driver board| Motor stops| Try to restart machine by turning the switch OFF, then ON again| If the problem persists, bring the unit to an authorized service center for repair

Customer Support

QTech Global Ltd
1a Quillyburn Business Park
Banbridge Road
Dromore
County Down
BT25 1BY
Email sales@qtechspray.com
Phone
UK 01895 276751
ROI 0 1690 3162
International +44 1895 276751
www.QTechSpray.com
 @QTechSpray

QTech QT290 Electric Airless Sprayer

Symbols

CAUTION
This manual contains important warnings and information PLEASE READ & KEEP FOR FUTURE REFERENCE VERSION QT290-12-0623

QTech Global Ltd
1a Quillyburn Business Park, Banbridge Road, Dromore, County Down BT25 1BY
Declares that the
QTech QT290 Electric Airless Sprayer
is in compliance with the regulations included in:
2006/42/EC Machinery Directive
2014/35/EU Low Voltage Directive
2014/30/EU Electromagnetic Compatibility Directive
The standards applied by the manufacturer are:
EN55014-1:2006+A1; A1:2009+A2:2011
EN55014-1:2017
EN55014-2:2015
EN61000-3-2:2014
EN61000-3-3:2013

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals