LG PREMTA201 Air Conditioner User Manual
- June 2, 2024
- LG
Table of Contents
- LG PREMTA201 Air Conditioner
- Product Information
- Product Usage Instructions
- FAQs
- SAFETY PRECAUTIONS
- PRODUCT CONFIGURATION AND INSTALLATION OF REMOTE CONTROL
- 3 Switch OFF: Master (Default setting for shipment)
- 3 Switch ON: Slave
- STANDARD OPERATION
- ADDITIONAL FEATURES
- SCHEDULE
- SETTINGS
- INSTALLER SETTINGS
- CHECKLIST BEFORE REPORTING FAILURE
- FCC
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LG PREMTA201 Air Conditioner
Product Information
Specifications:
- Model: Deluxe Wired Remote Control
- Model Number: MFL71781803 Rev.00_102422
- Compatibility: Air Conditioner
Product Usage Instructions
Safety Precautions
Before using the product, please carefully read and follow all safety precautions mentioned in the manual to prevent any unexpected danger or damages.
Product Configuration and Installation of Remote Control
Product Configuration:
- Pull the cable from the wall and check the cable direction for installation.
- Align the back cover (installation plate) and locate the mounting holes on the wall.
- Secure the back cover in place using screws through the mounting holes.
Installation of Remote Control:
Follow these steps for installing the remote control:
- Connect the power cable to the terminal at the bottom of the remote control.
Standard Operation
The standard operation includes viewing the screen, basic operation functions, and ventilation settings. Refer to the manual for detailed instructions on each operation.
Additional Features
Explore additional features such as scheduling, timers, and other advanced settings provided by the product. Follow the manual guidelines for utilizing these features effectively.
Using the LG ThinQ App
Discover how to connect and control the product using the LG ThinQ app. Refer to the manual for instructions on setting up the Wi-Fi module and accessing additional functions through the app.
FAQs
- Q: What should I do if I encounter a power outage?
- A: In case of a power outage, refer to the self-diagnosis section of the manual for guidance on power outage compensation and other related procedures.
- Q: How can I set a daily schedule for the air conditioner?
- A: To set a daily schedule, follow the instructions provided in the Schedule section of the manual. You can view, edit, add, or delete schedules as needed.
“`
ENGLISH
ITALIANO
ESPAÑOL FRANÇAIS DEUTSCH
OWNER’S & INSTALLATION MANUAL
AIR CONDITIONER
CESTINA
POLSKI PORTUGUÊS TÜRKÇE
Make sure to read the “Safety Precautions” carefully prior to using this
product. Please keep this manual where it can be accessed anytime by the user
of the product. The product’s warranty is included in this manual.
Deluxe Wired Remote Control
Whisen installation license When the product is being installed, make sure
to check the installation technician’s Whisen Installation License symbol of
quality. Having a technician with a Whisen Installation License install the
product will guarantee the product’s best performance and lifespan.
MFL71781803 Rev.00_102422
www.lge.com Copyright © 2022 LG Electronics Inc. All Rights Reserved.
SAFETY PRECAUTIONS
READ ALL INSTRUCTIONS BEFORE USE
The following safety precautions items are used to prevent unexpected danger
or damages ahead of time by using the product safely and accurately. The
cautions are divided into WARNING’ and
CAUTION’, and the meanings are as
follows.
This symbol is used to call the user’s attention to matters and operation that
can cause danger. The symbol means that you must carefully read and follow the
instructions to avoid danger.
WARNING
There is a possibility of serious injury or death if the instructions are
violated.
CAUTION
Failure to comply with these instructions may cause damage to the product or
moderate injury to the user. · The system air conditioner is not to be moved.
If it must be moved inevitably, make sure to contact the system air
conditioner store that has the LG Electronics system air conditioner
installation license. · In the case of apartments, system air conditioners
included in the basic items at the time of sale cannot be relocated in
accordance with Housing Supply Regulations. · Get the help of a professional
installer when moving and reinstalling the air conditioner. (If the product is
damaged due
to reinstallation performed by a moving center or the owner, repairs will be
charged. Be sure to check for any issues when installing.)
WARNING Installation related
You must contact the nearest service center or installation center for product
installation. · Or it may cause fire, electric shock, explosion, or injury.
Use the standard parts. · Otherwise, fire hazard, electric shock, explosion,
injury, or malfunction may occur. Request installation from installation shop
or service center when reinstalling the product. · Or it may cause fire,
electric shock, explosion, or injury. Do not store or use any flammable gas or
material in proximity to the product. · There will be a risk of fire or
product malfunction. Do not disassemble, modify or repair the product
arbitrarily. · There is a risk of fire or electric shock. Do not install the
product in a humid place or a place where rain may fall. · Or it may cause the
product to malfunction. Do not embed the product in a wall. · Or it may cause
the product to malfunction. Do not install the appliance somewhere exposed to
direct sunlight. · Or it may cause deterioration of the performance of the
filter.
03
Use-related
Do not repla ce or extend the power cords. · Do not put fire equipment near
the product. Do not put fire equipment near the product. · It may cause a
fire. Do not spill water inside of the product. · It may cause electric shocks
or the product may malfunction. If the product has come in contact with water,
be sure to contact an LG after-service center or professional A/C store. ·
There is a risk of fire or electric shock. Do not place the power line near a
heater appliance or the like. · There is a risk of fire or electric shock. Do
not put anything heavy on the power line. · There is a risk of fire or
electric shock. Do not place a heavy object on the product. · It may cause the
product to malfunction. Let children and the old and the weak and the infirm
use the product under the supervision of a guardian. · There will be a risk of
accident or product failure. Do not allow anything to strike the product. ·
Any impact on the product may cause failure. Do not impose shock with a sharp
or pointy object. · It may damage parts and cause failure.
CAUTION Installation related
Do not install oA r use the product in places at risk of explosion.
Use-related
Do not clean with strong solvent detergent; use a soft cloth. · It otherwise
may cause a fire or product deformation. Do not touch the product with a wet
hand or pull the lead line. · It may cause product failure or electric shock.
User Guide
Class B Device (Broadcast and communication instruments for domestic use) This
product has been certified for Class B electromagnetic waves for domestic use
and intends to serve domestic purposes, regardless of region.
04
PRODUCT CONFIGURATION AND INSTALLATION OF REMOTE CONTROL
Product Configuration
1 Pull the cable from the wall and check the cable direction to install.
2 Align the back cover (installation plate) and check the positions of two
mounting holes on the wall.
3 Fix the back cover on the installation position through the mounting holes
by using screws.
Remote controller
Wall plate
or
Remote control fixing screws (2EA)
OWNER’S & INSTALLATION MANUAL
Connecting wire (1 EA)
Wall plate
Back Cover (Installation Plate)
Back Cover (Installation Plate)
NOTE
· Depending on your environment, you can install the remote control neatly by
placing the wall plate on the wall and tightening the back cover.
4 Connect the power cable to the terminal at the bottom of the remote control as shown in the figure below.
Installation of Remote Control
Follow the below guidelines for installing the remote control.
NOTE · During wired remote control installation, do not embed
inside the wall. (It may cause temperature sensor failure.) Do not install the
cable over 50 m. (It may cause communication defects.) · When installing the
extension cable, carefully check the direction of the connectors on the remote
control side and the product side before the installation. · Extension cable
specification: Use AWG 24, 3 conductor equivalent or higher wired cables. · Do
not install cables longer than 50 m, as this may cause communication problems.
· Install the product so that it doesn’t bend or cause a clearance with the
wall. · Incorrect wiring can cause damage to the product. · To avoid damage by
static electricity, touch the metal parts before handling the remote control
to discharge the static electricity from the body. * 10 m Cable model: PCW-
QE10A
GND / SIG / 12V
5 Place the lower part of the remote control under the back cover, and fix the
power cable to the back cover hook as show6n in the figure below to the place
where the power cable will come out of the back cover. Hook
(Figure.1)
05
6 You can install wired remote control cable in 3 directions. Install in the
direction suitable for installation environment.
· Connection direction for remote control cable: Back center, left upper end,
right upper end
· When installing the remote control cable on an upper side, first remove the
remote control cable guide groove before installing it.
Use a long nose when removing the guide groove, and polish the cut surface
after removing it.
Using Group Control
Connect two to 16 indoor units of air conditioner to a single controller for
control.
GND Signal wire
DC 12V
GND Signal wire
7 Fix the power cable on the back cover hook, and press the upper side of the
remote control toward the back cover as in the figure.
Wall
NOTE · Connect using the group control cable.
(Model : PZRCWRCG3) · When using the group control, some advanced functions
(excluding basic operation setting, fan speed, lock, and time setting) may be
limited.
1 Set one indoor unit to master and the remaining to slave.
Remote Control
NOTE · Failure to follow the guidelines may result in part damage
due to interference with the machine. Be careful not to let the cable pass
over the wireless equipment.
8 Close the lower cover.
3 Switch OFF: Master (Default setting for shipment)
3 Switch ON: Slave
NOTE · For ceiling cassette and duct products, change the switch
setting of the indoor PCB as above. · For wall-mount type and stand type
product, change the
master/slave setting with the wireless remote control.
2 After completing the master/slave setting, turn off the power of the indoor
unit, and turn on the power after 1 minute.
NOTE · 2-Remo function is not supported.
06
STANDARD OPERATION
1 The welcome screen will be displayed after synchronizing with the indoor unit. Booting may require up to 90 sec.
2 Please check the settings displayed on the screen and set them up.
3 When completely setting the installation wizard, the
button is changed into the
button, and if
you press the
button, the installation is done.
Function
Description
Date Time Time Format
Set the date, time, and time format displayed on the remote control.
Temperature unit
A function to set the temperature unit displayed on the remote control.
A function to control the screen OFF Standby Screen time and brightness of the
remote
control.
A function to determine whether to disHumidity Display play the humidity on
the main screen
and the standby screen.
A function to set whether to use the
Main Screen Auto auto return to the main screen when
Return
there is no touch input for a certain
period of time.
Sound
A function to set whether to output a sound when the screen touch input is given.
NOTE
· If you do not complete the installation wizard, the installation wizard will
run every time you boot it.
· Even after completing the installation wizard, the items of the installation
wizard can be checked on the Settings Service.
· Refer to the general settings and schedule page for detailed setup
instructions.
· Even if you turn off the power and then turn on it, the booting may require
up to 90 sec.
07
View Screen
The home screen of the wired remote control is configured as below, and the
below screen is displayed in accordance with the connected indoor unit.
1 Air Conditioner
5 Air Conditioner/Ventilation Interlock
2 General ventilation
NOTE
· Please check the detailed description of each screen in the detailed
description page.
3 DX Ventilation 4 Housing Ventilation
08
Standard Operation
Operating Information
Operation Mode Select the operation mode to set the desired mode. – Details of operation mode
Operation Mode
Cooling
Description
It cools down the room with pleasant and fresh wind.
Heating It provides a warm breeze to the room.
Auto
The product automatically provides the wind of the right temperature for the room.
Dehumidifi- It removes moisture while providing weak cation cooling.
Air blowing It blows the indoor air as is, not cold wind.
Emergency Heater
You use set to use the emergency heater, you can select the emergency heater mode to use the heater.
Air cleaning Operates air purifier only.
Power Power heating rapidly increases the room heating temperature.
Power Cool
Power Cool rapidly reduces the room temperature.
Himalaya Cool
The local special function applied to models in the India region quickly reduces room temperature.
Monsoon Dehumidifi-
cation
A local special dehumidification function applied to models in India.
NOTE · The reason why the cool air isn’t coming out immediately
after cooling is started is because of its function to protect the compressor.
After 3 minutes, the compressor operates, and a cold wind comes out. ·
Depending on the outdoor unit cycle operation, the background color of the
home screen is expressed in red for heater and blue for air conditioner. · The
emergency heater is activated under emergency heating conditions after the
installation and related settings. · Depending on the product, some functions
cannot be set.
Room temperature Displays room temperature.
Set temperature The set temperature area for the current operation mode is
displayed.
Operation Mode
Cooling
Heating Exclusive model
for cooling Auto
Model for both cooling/heating
Setting Temperature 16 ~ 30 °C (60 ~ 86 °F) 16 ~ 30 °C (60 ~ 86 °F) Cold, A
Little Cold, Pleasant, A
Little Hot, Hot
18 ~ 30 °C (64 ~ 86 °F)
NOTE · When using the dehumidification/air blowing operation,
you cannot set the desired temperature. · The setting temperature may vary
depending on the type
of indoor unit.
Wind Strength Settings Select a wind strength icon and select a desired wind
strength in the options list.
1
Very weak
2
Weak
3
Moderate
4
Power
5
Special Power
A
Auto
NOTE · Depending on the product, some functions cannot be set.
09
Additional Functions You can use additional functions. Please refer to the
additional functions detailed description page.
Menu You can select the menu icon and enter to set the schedule, timer,
energy, monitoring, and settings. You can also check the Notification
information.
Smart Care This is a function that manages the indoors pleasantly and saves energy through AI operation.
- You can select the icon to use Smart Care.
- When Smart Care works, it is displayed on the left upper end of the main screen.
NOTE
· When there is a notification, the number of notifications and the
notification icon are both displayed.
· If you press the icon, you will be moved to the notification screen.
- When the operation condition is not Smart Care, the standby status is displayed as below.
NOTE
· Smart Care may not be displayed/work in some products.
· Smart Care only works when the product is cooling or heating.
· You may feel that cooling and heating are weak due to the power saving
operation of Smart Care.
· Precisely set the date and time for the remote control and the central
controller when installing the AI engine.
· If you do not set the date and time, an incorrect result value may show.
· The site connected to our central controller places priority on the date and
time settings of the central controller than those of the wired remote
control.
· In case of model for both cooling/heating, if the simultaneous operation of
both cooling/heating is working, Smart Care is not available.
10
Humidity Displays the room humidity.
NOTE · The displayed humidify may vary according to the
humidity sensing position settings (set by the installer). · Remote control:
Remote control humidity display · Indoor unit: When the indoor unit humidity
is received, it
displays the indoor unit humidity, and if not, no humidity is displayed.
Indoor air quality A function to monitor the dust value measured by the dust
sensor in the indoor unit. You can check the concentration value of each of
fine dust (PM10), ultrafine dust (PM2.5), extreme ultrafine dust (PM1.0) on
the air quality screen. The general quality displays the worst dust status
value among the three dust status values.
Indoor Unit Name Displays the connected indoor unit.
Current time Displays current time.
Run/Stop button You can turn on/off the indoor unit with the remote control.
Ventilation 1 General ventilation
2 DX ventilation
3 Housing Ventilation
Operation Mode Select the operation mode to set the desired mode. Select OFF from the options list to stop operation. – Details of operation mode
Operation Mode
Description
Applicable models
Cooling
It cools down the room with pleasant and fresh wind.
DX exclusive
Heating
It provides a warm breeze to the room.
DX exclusive
Auto
The product automatically provides the wind of the right temperature for the room.
DX exclusive
Natural wind
ventilation
A mode in which the exhausted air is ventilated not through the total heat exchanger. It is proper for spring or fall or when the room pollution is severe.
All models
A mode to ventilate through the total Room heat exchanger for both air
supply/air tempera- exhaust. Good for summer or winter All ture ven- when the
difference in temperature models tilation between indoors and outdoors is
high.
Auto ventila-
tion
The room temperature and the outdoor temperature of the ventilation system are measured and the optimal ventilation mode is run automatically.
All models
Wind strength settings
Select a wind strength icon and select a desired wind strength in the options
list.
1
Weak
2
Power
3
Special Power
A
Auto
NOTE · You can select Manual when the CO2 sensor is connected
when the wind strength auto is set.
Additional functions You can use additional functions. Please refer to the
additional functions detailed description page.
Air conditioner mode and desired temperature Set the air conditioner operation
mode (cooling/heating/ auto) and the desired temperature.
Outdoor air quality The outdoor air quality is displayed for outdoor fine dust
(PM10), outdoor ultrafine dust (PM2.5), and outdoor extreme ultrafine dust
(PM1.0).
Air quality You can check the concentration value of each of the room/ outdoor
fine dust (PM10), ultrafine dust (PM2.5), and extreme ultrafine dust (PM1.0)
on the air quality screen.
CO2 (Carbon dioxide) Displays the room CO2 concentration (ppm).
12
ADDITIONAL FEATURES
You can use the additional functions of the product.
The functions of the large buttons need detailed settings other than Setting
and Cancel. Tapping an area above the item changes the set cancel status and
tapping an area below moves to the Setup Details page.
You can select only select Setting or Cancel for the functions of small
buttons without detailed settings.
NOTE · Depending on the product, there may be features that are not supported.
· The color of the icons on the screen changes according to the setting
status.
Setting (On): Cancel (Off):
Function Air Con- VentiName ditioner lation
Description
A function to enhance the heating ca-
Heater
pacity by turning on the electric heater for heating operation. Available only
ON/OFF
during the heating operation.
Note & Option
Power-saving
Cooling
Power-saving cooling is the function to adjust the desired temperature during cooling operation to enhance the comfort of the user and improve the power- saving performance.
ON/OFF
· It’s only possible when you’re operating with cooling.
· You cannot set the Power-saving cooling, Concentration-adding wind, and the
Auto custom wind functions at the same time.
Fan Auto
ON/OFF
A function to set for the operation of the · When it is set to be ON, the indoor fan works
indoor unit fan when the indoor unit is when the product is working, and when the room
thermal off.
temperature reaches the desired temperature
and the outdoor unit stops, the indoor fan stops
as well.
Comfort
pow-
er-saving
A function to automatically control the cooling strength and keep pleasant DX feeling without turning off the product even after the room temperature has reached the desired temperature.
ON/OFF
· The Comfort power-saving function is available only when the product is
cooling.
Ventilation Kit
A function to set the operation for the ventilation kit which can be additionally ON/OFF installed on the indoor unit.
13
Function Air Con- VentiName ditioner lation
Description
Note & Option
Ventilation-interlock pow- er-saving cooling
ON/OFF
A function to save energy by using cool
outdoor air when the ventilation product · The ventilation-interlock power- saving cooling
is interlocked and the cooling operation function can work only when the air conditioner
is working.
product is cooling and the ventilation product is
operating.
Air cleaning
It makes the indoor air clean and pleasant.
ON/OFF
· The air cleaning function is available only when the product is operating.
· When connected to the air cleaning-only model, it can work even when the
product is not working.
Robot cleaning
A function to automatically clean the filter using a cleaner on the product when the air conditioner has been used for a ON/OFF certain period of time. It can be set 30 seconds after the operation stops.
Humidification
A function to operate the humidifier on the product when the room is dry.
ON/OFF
Mosquito repellant
Set operation/stop of mosquito away function.
ON/OFF
Zone control
A function available when a duct-type air conditioner product is linked. You can set up to eight zones and control the operation of each zone.
The function can be used actively only when the zone type and the number of
zones are set.
· The duct-type air conditioner product supports the zone control function and
an additional damper control apparatus is required to perform the zone
control.
· Differences according to zone type
– Old type: Only the zone operation status using the wired remote control can
be checked.
– New type (4 zones or 8 zones): The zone control and monitoring are available
through the wired remote control.
Additional Operation
You can change the additional operation of ventilation product.
· Fast: Ventilates fast. It is a function to more efficiently operate the
ventilation function through the fast setting which is an additional operation
of the ventilation product.
· Power-saving: It performs the power-saving function while efficiently
ventilating the air.
14
Function Air Con- VentiName ditioner lation
Description
Note & Option
Airflow Direction
You can conveniently control the wind direction as you wish.
Up and Down Rotation (Forest Wind) Left and Right Rotation Four-way Rotation Comfort wind Indirect wind (Air guide wind) Direct wind (High ceiling wind) Human detecting indirect wind Human detecting direct wind Auto temp wind (Auto custom wind) Study wind (Concentration reinforcing wind) Human detection space wind Human detection activity wind Forest wind Long power fan Manner fan
15
SCHEDULE
Select the Schedule in the menu screen and move to the schedule settings
screen. Select the menu to set in the schedule settings screen and you can
move to the details screen.
Daily Schedule Status
A function to check the schedule status saved in the remote control.
Add Schedule
You can add a schedule saved in the remote control.
If a schedule is booked, the operation mode icon is displayed on the time line
at the scheduled time.
An inactivated schedule is not displayed on the time line.
If various schedules are booked within one hour, is displayed instead of the
operation mode icon.
If you select , you can check the booked schedule by selecting the left or the
right button in the booking details on a lower end of the screen.
View and Edit Schedule
A function to check the schedule status saved in the remote control.
You can add a new schedule by selecting the `+’ button.
You can set the time for performing the scheduled operation in the `time settings.’
You can set the day or period for operating the schedule in the `repeat’ settings.
You can set the operation information for the schedule in the `operation settings.’ – When the operation is OFF, you cannot set the mode, temperature, and the wind strength.
If you have completed adding the schedule by performing
through and pressing the
button, a message
saying `the schedule is added’ appears and you are moved
to the schedule view and edit screen.
Delete Schedule
You can delete the schedule stored in the remote control.
Youw can check the operation information (operation ON/ OFF, operation mode,
desired temperature) of the set schedule, the schedule time, period, and day.
You can edit it by selecting the booking information of the saved schedule.
You can select the schedule event to be deleted in the
schedule list and press the
button to delete it.
16
Designate Exception Date
A function to automatically stop operation on the preset date.
Schedule Initialization
All the schedule-related information will be initialized.
Select the Designate Exception Date item in the schedule list, and you are moved to the details screen for Designate Exceptional Date.
You can check, add, modify, or delete the exceptional date information stored in the remote control in the Designate Exceptional Date.
To add an exception date, designate the start/end date
on the details screen for registering the exceptional
date, and press the
button. Then, the exceptional
date is stored.
Press the exceptional date to be edited, and move to the edit screen.
NOTE · Activate: Set the activate/inactivate of the selected
exceptional date. · Title: Change the title of the selected exceptional date.
· Repeat: Modify the repeat or non-repeat of the selected
exceptional date. · Period: Modify the period of the selected exceptional
date.
17
TIMER
Select the timer item in the menu screen and move to the timer setting screen.
You can move to the details screen by selecting the menu to set in the timer
settings screen.
Simple Timer
You can conveniently set the booking for operation or stop.
OFF Timer
The product is turned OFF automatically at the set time.
NOTE · If the product operation is ON, the simple timer is turned
OFF after the relevant time has passed. · If the product operation is OFF, the
simple timer is turned
ON after the relevant time has passed. · In the simple timer, if the operation
is turned ON or
OFF before the operation of the timer, the set timer is canceled.
Sleep Timer
The sleep timer is a function to operate or stop the air conditioner in the
sleep mode after a certain period of time before sleep.
NOTE · The OFF timer is not canceled even if the operation is
turned ON or OFF before the timer works.
ON Timer
The product is turned ON automatically at the set time.
NOTE · The ON timer is not canceled even if the operation is
turned ON or OFF before the timer works.
NOTE · The sleep timer can be set when the product is operating. · In the
sleep timer, if the operation is turned OFF before
the timer works, the timer is canceled.
18
ENERGY
Tap on the energy item in the menu.
You can check energy usage and set power saving settings for energy saving.
NOTE · Depending on the units selected, the accumulated energy
usage/power usage over a day/week/month is displayed. · This function may not
be provided depending on the
indoor unit.
AI energy control
This is a function that allows you to check the predicted savings by
calculating the system’s overall energy consumption and “Smart Care” use.
Trend Graph You can check the trend of the outdoor unit operation rate, indoor temperature, and desired temperature information during the day.
In the energy settings list, if you select AI energy control, you are moved to the `AI energy control system power usage’ settings menu.
Usage Graph You can compare energy usage time/power usage on a weekly/monthly/annual basis. You can check by usage time/power usage.
e.g. Daily basis – Total usage: 1,000 kWh, predicted savings: 30 kWh – Total
usage when reduced by using Smart Care: 1,000
kWh – Expected usage when not using Smart Care: 1,030 kWh
NOTE · Smart Care may not be displayed/work in some products. · The displayed
value is the power consumption for the
entire system. · The predicted savings are calculated by analyzing the
energy usage patterns while using Smart Care. For more information, refer to
the LG AI engine manual or the outdoor unit installation manual. · There may
be some difference between the actual usage, so use it only as a reference. ·
If you need the exact usage, install an additional PDI (power divider) and use
it.
19
MONITORING
In the menu screen, select the monitoring item and move to the monitoring
screen. In the center of the monitoring screen, the product operation status
is displayed.
NOTE · The main information that can affect the product operation
is displayed on the left lower end of the home screen. · The warning icons
related to CO2, oil change, Uvnano
operation, and errors are displayed on the left lower end of the home screen.
· UVnano is a compound word of “UV (ultraviolet rays)” and “nanometer (a unit
of length)”.
Description of the Icon A notification that the CO2 density is too high. When
CO2 the ventilation product is connected, this is displayed when the CO2
concentration is around 940 ppm or higher. GHP outdoor unit engine oil
replacement notification. Displayed when 10,000 hours of accumulated operation
time of GHP outdoor unit have elapsed. UV Displayed when the UV UVnano
function is working. Displayed when repair is needed during the Uvnano UV
function. If the UV alarm is displayed, contact LG Electronics Service Center
for repair.
20
SETTINGS
Select Settings in the menu. You can set the general settings, air conditioner/ventilation settings, service settings, and installer settings for the configuration of the usage environment.
General Settings
Function
Description
Temperature A function to set the temperature unit displayed on
unit
the remote control.
Note & Option
Celsius
Fahrenheit
0.1 °C / 0.5 °C / 1 °C
The Fahrenheit temperature unit operates by receiving the temperature unit from the indoor unit.
Standby screen Standby screen
entry time
brightness
Content
Standby Screen
Off
Off 15 s 30 s 1 min
25 % 50 % 75 % 100 %
Current status date & time weather
Auto
A function to adjust the screen off time of the remote · If the Standby Screen Brightness is used at 100%,
control and the standby screen brightness.
the LCD life may be reduced.
· The `Auto’ of the Standby Screen Brightness is activated only in the indoor unit with a human detection sensor kit.
· When it is set to be ‘Auto,’ the wired remote control standby screen brightness is controlled in accordance with the intensity of illumination detected by the human detection sensor.
· The content set value `Weather’ requires connection to the ThinQ app.
Date & Time
A function to set the date and time displayed on the remote control.
–
Lock
A function to lock the buttons of the remote control for preventing children or any other person from using the remote control in an improper manner.
All lock/Operation lock/Mode lock/Air volume lock/ Temperature lock/Desired temperature range lock
21
Function
Description
System restart A function to restart the remote control.
Note & Option –
Humidity Display
The function to decide whether to display humidity on the main screen and the standby screen.
ON/OFF
· When it is set to `ON,’ the humidity value varies according to the humidity
sensing position settings (installer settings).
- Remote control: Displays the humidity that remote control sensed.
- Indoor unit : Displays the humidity that indoor unit sensed. However, if no information is received, humidity is not displayed.
Heterogeneous operation display
A function to set whether to display the status where the operation mode selection is unavailable in accordance with the outdoor unit operation when the cooling/heating mode is selected in a product which does not support the cooling/heating operation at the same time.
ON/OFF
A function to set a password for preventing children
User password or any other person from randomly changing the
–
remote control settings.
Controller WiFi pairing
To connect the remote control to the ThinQ app, the pairing function of the Wi-Fi module built in the remote control is activated.
–
Main Screen Auto Return
A function to set whether to use the auto return to the main screen when there is no touch input for a certain period of time.
ON/OFF
Sound Activates the button touch sound effect.
ON/OFF
Dust mark type A function to set the dust mark phrases.
LG/ Standards
· LG: It is displayed as fine dust (PM 10), ultra fine dust (PM.2.5), and
extreme ultrafine dust (PM.1.0).
· Standards: PM 10, PM 2.5, PM 1.0
22
Air conditioner/ventilation settings
Function
Product
Air Condi- Ventitioner lation
Description
Option
Up and
Down wind
angle
Entire control
Individual control
Standard
You can adjust the angle in which
the air blows.
Set the wind angle of all vanes in the product at once.
Individually set the angle of the vanes.
Set the wind angle in the factory data reset status.
Elevation Grill
A function to operate the elevation grill for cleaning the indoor unit filter.
· Rise: Elevate the elevation grill toward the product. · Stop: Stop the movement of the elevation grill. · Fall: Lower the elevation grill toward the floor.
Robot cleaning
Auto Dry
Filter status
check and
reset
The robot cleaning function is to
allow the cleaner on the product
to automatically clean the filter · Auto: When the cumulative operation time of the
when the air conditioner is used indoor unit has passed 30 hours, the robot cleaning
for a certain period of time or
is conducted automatically.
longer. Sets the robot cleaning to
work manually or automatically. It · Manual: The robot cleaning is conducted manually.
can be set 30 seconds after the
operation stops.
General model
Auto dry operation time selection available model
The auto dry function is to remove mold and humidity by drying the inside of the indoor unit when the product is turned OFF after a cooling operation.
Use Disabled
Use Disabled 10 min 30 min 60 minutes
AI Dry
· AI Dry: Automatically control the drying time by referring to the humidity.
It is available only when there is a humidity sensor.
You can check the filter status and reset the filter usage time.
· The remaining time to clean the filter is for reference, and the actual
filter status may vary depending on the installation environment and usage
conditions.
· When dust is put on the filter, the cooling/heating capacity is lowered with
a high electricity charge, so please clean the filter when the time comes.
23
Function
Product
Air Condi- Ventitioner lation
Description
Wi-Fi pairing
A function to run the pairing function of the Wi-FI module connect ed to the indoor unit. In case of the old ventilation product, the function may not be displayed.
Conversion
temperature
The conversion temperature is a function to set a temperature by which cooling and heating oper- 1~7 °C (2~14 °F) ation is automatically converted according to a temperature.
Zone Name:
The name of each Zone to be used for zone control can be determined by directly typing it according to the user’s style.
Option –
–
Comfort
power-sav-
ing
A function to set the outdoor unit comfort power-saving operation Stage
1/Stage 2/Stage 3
stage value.
Outdoor
Unit Refrig-
erant Noise
Reduction
Outdoor unit defrost mode
Active pow-
er-saving
Outdoor unit
low noise
operation
time
A function to set the refrigerant noise reducing function of the
outdoor unit.
A function to set the defrosting mode operation of the outdoor
unit.
· This function is available only if the outdoor unit Master / Slave setting of the installer settings is
A function to set the active
Master.
power-saving stage value of the
outdoor unit. (Active power-sav-
ing is a function to operate by calculating the required perfor-
mance from the air temperature
and humidity in the indoors and
the outdoors.)
· The outdoor unit low noise operation time settings
A function to set the start time
function can be set only when the installer settings’
and end time of the outdoor unit outdoor unit function M/S setting is `Master’, and
low noise mode operation.
the outdoor unit low noise control reference setting
is `Remote control.’
Tempera-
ture-based fan auto
operation
A function to set the auto fan usage based on the temperature ON/OFF of the indoor unit.
24
Function
Human detection operation
Product
Air Condi- Ventitioner lation
Description
Option
Power Saving Operation Using Body Sensor
· OFF: Not using the Human detection power-saving operation.
· On/Off learned power-saving: When
no user is detected for a set time,
the product is turned OFF for saving
It is the function to set the opera- power.
tion of human detection mode. · Temp power-saving: When no
user is detected for a set time, the
desired temperature of the product is
controlled for saving power.
· Activity custom power-saving: It can control the set temperature in accordance with the activity and save energy.
Time
5 / 10 / 15 / 30 / 60 / 90 min.
Select an upper/lower
end
This is a function to set the usage of the upper and lower vanes Entire control/Upper/Lower when operating the product.
Custom temperature
A function to set the desired temperature in initial operating mode when the user saves a set desired temperature.
ON/OFF
Economizer
A function to supply external air into the room for saving energy and improving room air quality.
· OFF: Cancel the economizer function and keep the damper closed.
· Auto: When the external air condition is lower than the room air condition
in case of cooling operation, the external air is supplied to the room to save
energy.
· Stage 1: Opens the outer air damper opening by one stage to improve the
indoor air quality by introducing fresh air into the room.
· Stage 2: Opens the outer air damper opening by two stages to improve the
indoor air quality by introducing fresh air into the room.
AC display
brightness
A function to control the indoor unit status display brightness.
· General model: OFF/ON/Auto
· Brightness-controllable model: 100%/50%/OFF/ Auto
· Auto’ setting is enabled only in the indoor units equipped with the human body sensor kit. · When it is set to be
Auto,’ it is automatically controlled in accordance
with the intensity of illumination detected by the human detection sensor.
25
Function
Product
Air Condi- Ventitioner lation
Description
AC air quali-
ty brightness
A function to control the air quality display brightness of the indoor unit.
ON/OFF
Option
UVnano
Fine dust filter status
Pre-filter status
The UVnano function is to steril-
ize the fan or the filter by using a UV LED at regular time intervals
ON/OFF
when the indoor unit is working.
You can check the fine dust filter status and reset the filter usage time.
· The used and remaining amount are for reference, and the actual filter status may vary depending on the installation environment and usage conditions.
· When dust is caught in the filter, the airflow
decreases and the electric bill is high, so be sure
to clean or replace the filter when it is time to clean
or replace it.
You can check the pre-filter status and reset the filter usage time.
· The fine dust filter (HEPA filter) check mark will not be cleared unless you specifically clear it.
· The pre-filter check mark will be cleared after a
certain time even if you don’t specifically clear it.
Delay time
Night external air
cooling
A function to set the operation to work after a delay time in case of 1-60
min. (by the unit of one min.)
ventilation operation.
· After setting the function ON, set the start time and the end time.
A function to discharge the room · Only when the air conditioner and the ventilation
heat and supply the cool external air into the room at summer night
are both stopped, it is determined whether to operate the night external air cooling or not.
for saving energy.
· Even if it is the set night external air cooling time,
the night external air cooling is started only when
the outdoor temperature condition is met.
CO2 Fan Control
This function sets the FAN
Fan Control During Oper- Fan Control During Oper-
operating standards based on the CO2 concentration of ventilation
ation On
ation Off
products.
OFF/Sporadic wind/Weak OFF/Sporadic wind
Humidity range selec-
tion
Min. humidity
Max. humidity
A function to set the room hu midification operation range of
direct-type ventilation product.
20% ~ 70%
50% ~ 80%
· The min. humidity and the max. humidity can be changed by 5% at a time.
· The min. humidity and the max. humidity must be kept different from each
other by 10%.
26
Function
Product
Air Condi- Ventitioner lation
Description
Option
Interlock air purification with AC and ventilation
AC-ventilation air purification interlock is a function that aids
ON/OFF
with indoor air purification by
· If the AC’s fine dust concentration is bad or very
operating ventilation with the air bad, ventilation is interlocked.
purification operation of the AC when the indoor fine dust concentration is bad.
· Ventilation is operated at Special High Speed during interlocking operation.
NOTE · Depending on the product, some functions may not work.
CAUTION
· Set it to off if the low noise operation time setting and night outdoor
cooling setting functions are not used. · Low noise operation can reduce
cooling capacity.
Service setup
Function
Service contact
Room external air model information
check Model Name
Description A function to check and input the phone number of the available
service center when a failure occurs in the product.
A function to check the indoor and outdoor units product groups and capacity
information connected to the remote control.
A function to check the model name of the remote control.
Software version A function to check the software version of the remote control.
Open source license A function to check the open source license of the remote control.
Installation wizard
A function to change the installation wizard settings set for the initial installation of the remote control.
Software Update A function to update the software version of the wired remote control using the OTG port.
27
INSTALLER SETTINGS
Select the installer settings in the settings menu. Various settings can be
made during the installation step before using air conditioner/ventilation
products. Please enter the password. * How to know the password Check the
software version in the service settings menu. If SW version is 2.000,
password is 2000.
Tap the Magnifier icon in the upper right corner, making it easy to find what
you want. – Auto-complete items are displayed based on the characters you
enter. – You can also search by the code number of installer setting.
28
Air Conditioner/Ventilation Installer Settings
Function
Product
Air Con- Ventiladitioner tion
Description
Test-Running
A function to set the test-running when initially installing the product.
Option –
Central control address
A function to set the central control address of the indoor unit when con- 00
~ FF
necting the central controller.
ESP (External Static Pressure)
A function for setting the air volume value corresponding to each air volume and to facilitate installation.
Set the RPM value for each fan speed.
Temperature
sensor (2TH)
designation
A function to select the temperature sensor for determining the room
temperature.
Remote control/Indoor unit/2TH
Ceiling height
A function to control the stage of air volume in accordance with the height Low/Standard/High/Very high of the ceiling in a ceiling-type product.
Static pressure settings
V-H: Indoor fan speed change, High pressure
This function changes the fan speed in F-H: Fixed with set fan speed, High
presthe indoor FAN according to the open- sure ing and closing quantity of
Damper. V-L: Indoor fan speed change, Low presIt is available only in a duct
product. sure
F-L: Fixed with the set fan speed, Low pressure
Indoor unit
master/slave
settings
A function to prevent another mode
operation. In the function, the products
set to `Slave’ prevent the selection of the opposite mode of the operation
Master/Slave
mode of the indoor unit which is set to
`Master.’
Dry contact settings
A function which is available only when the dry contact apparatus is
separately Manual/Auto
purchased/installed.
Temporarily cancel the 3 min. delay
function of the outdoor compressor.
3 min. delay
Caution: Do not randomly set it
–
since it is a function used
for producing the products.
Standard operation mode
Measures the driving ability of the duct product.
ON/OFF
29
Function
Air volume fixing
Product
Air Con- Ventiladitioner tion
Description
Option
Variable: When the Comp is ON, it operates
in the set fan speed. Operate to
A function to set the air volume mode
low fan speed at COMP OFF.
of the indoor unit to be variable/fixed. Fixed: When the Comp is ON, it operates in
the set fan speed. Operate to set fan
speed at COMP OFF.
Zone (Type)
A function to set the zone type supported by the indoor unit such as the “new” and the “old” types.
Old: You can check only the operation status of the relevant zone by using the
wired remote control.
New of 8 Zone: You can control and monitor the zones by using the wired remote
control.
Number of Zones
A function to set the number of zones. It is available only when the zone type
2 ~ 8
is “New.”
Thermal On Thermal Off
Step 0
Operates in accordance with the product set value
Over Heating
Control the heating thermal ON/OFF
temperature conditions. Caution: If you incorrectly set it, it
may cause overheating or weak heating.
Step 1 Step 2 Step 3
4 °C (8 °F)
6 °C (12 °F)
2 °C (4 °F) 4 °C (8 °F)
-1 °C (-2 °F) 1 °C (2 °F)
Step 4
(Usage type: Displayed in case of dual)
-0.5 °C (-1 °F)
0.5 °C (1 °F)
Pipe temperature check
You can check the temperature of the pipe connected to the product.
–
Emergency
Heater
A function to determine whether to use the emergency heater control function Enabled/Disabled and set the usage environment.
30
Function
Product
Air Con- Ventiladitioner tion
Description
Group control
function limit
usage
A function to select the operation standards of the product in case of group control.
Option
Type 0: All indoor units connected work in the same status. Only the standard
functions are available.
Type 1: All indoor units connected work in the same status. The below
functions can be additionally used in accordance with the functions of the
Master indoor unit.
– Wind direction – Up and Down/Left and Right/Comfort wind, Additional
functions Power-saving cooling/Heater/Fan Auto, Up and Down wind angle –
Entire control
Type 2: When it is operated by the wired remote control, all the indoor units
connected work in the same status. When it is controlled by the wireless
remote control, only the indoor unit which has received the command works. You
can use all the functions of the master indoor unit.
Whether to
install the air
cleaning kit
Whether to install the heat-
er kit
Whether to install the humidi-
fication kit
Whether to
install the ele-
vation grill
A function to set whether to additionally install after mass-production or mount after removal for the option units (air cleaning/heater/humidification/elevation grill/ventilation/sub heater).
Installed/Not installed
Whether to install the venti-
lation kit
Whether to
install the sub
heater
Whether to
install the refrigerant leak
sensor
A function to set whether to install a flare fastening unit and welding unit
leak sensors on the indoor unit.
Installed/Not installed
31
Function
Product
Air Con- Ventiladitioner tion
Description
Indoor unit
address check
A function to check the address of the indoor unit designated from the
outdoor unit.
Option –
Thermal On Thermal Off
Over Cooling
Static Pressure Step
Control the cooling thermal ON/OFF
temperature conditions. Caution: If you incorrectly set it, it
may cause overheating or weak heating.
Step 0
Operates in accordance with the product set value
Step 1
6 °C (12 °F)
4 °C (8 °F)
Step 2
4 °C (8 °F) 2 °C (4 °F)
Step 3
1 °C (2 °F)
-1 °C (-2 °F)
This function allows you to set the static pressure of the duct product by subdividing it into 11 steps.
Stage 0-Stage 11
· If the static pressure stage settings are used, the static pressure settings
are not used.
· Please refer to the indoor unit product manual for the static pressure value
for each stage.
Guard (Time)
Set the outdoor unit cycle conversion operation standby time, and set the outdoor unit protection time for cycle conversion.
Stage 0: 0 min./Stage 1: 15 min./ Stage 2: 30 min./Stage 3: 45 min./ Stage 4: 60 min.
Fan operation in case of cool-
ing TH OFF
A function to set the operation of the indoor unit fan during the cooling
ther- Weak wind/OFF/Set wind
mal OFF operation.
Main heater
designation
A function to set the control to be conducted with priority on the heater usage than the outdoor unit cycle in case of operation of the indoor unit heating.
ON/OFF
Ventilation-in-
terlock air conditioner fan
operation
When the air conditioner and the ventilation product are interlocked for operation, the function sets whether to operate the fan of the air conditioner.
ON/OFF
Indoor unit
power outage
compensation
Enabled: Reset to the previous operation
In the event of a power outage, you can set whether to recover the product
status.
to its previous operating state.
Disabled: Reset to the operation OFF
status.
32
Function
Product
Air Con- Ventiladitioner tion
Description
Option
In-room sensor
maintenance
time
A function to set the absence determination maintenance time among the 0/10/30/60 min. in-room sensor values.
Simple dry con- tact installation
· Dry contact auto installation: When the
power is applied to the product, and
when the contact is ON with the dry
A function to set whether to install (use) the Dry contact. (It is not a func-
contact installed, the indoor unit product recognizes the dry contact installation.
tion for installing the dry contact but for · Dry contact manual non- installation: Not
setting the usage of the CN_CC port of use (install) the dry contact.
the indoor unit.)
· Dry contact manual installation: Use
(install) the dry contact.
· Simple ON/OFF: Use the Programmable DI/DO (Simple On/Off) usage.
Indoor unit
contact use
· Disabled: Use the simple dry contact set value.
· Simple operation control signal: Simple operation ON/OFF
· Single dry contact signal: Dry contact (simple contact)
· Single emergency stop signal: Indoor unit single emergency stop
· In-room/Absence signal: In-room/Absence
A function to set to control the external · Entire emergency stop signal: All indoor
input and output in accordance with
units’ emergency stop
the DI/DO set by the customer by
It can be set only when the indoor units
using the dry contact port of the indoor have the emergency stop function.
unit. (A function to determine the usage of the contact port (CN_EXT) mounted on the indoor unit PCB.)
· Window contact: In case of window contact, the indoor unit operation is processed.
It can be set only when the indoor units
have the window contact function.
· Window contact lock: When the window contact is locked, the indoor unit
operation is processed.
It can be set only when the indoor units have the window contact lock
function.
· MPM: Individual power module interlock mode
Outdoor unit
master/slave
settings
A function to set the function master/ salve of the outdoor unit.
Master/Slave
33
Function
Product
Air Con- Ventiladitioner tion
Description
Temperature-based auto
fan operation
A function to set the fan non-stop func-
tion usage of indoor unit. (A function
to operate the fan of the indoor unit for longer than the conventional operation
ON/OFF
method in the outdoor unit for maxi-
mizing the cooling/heating efficiency.)
Option
Outdoor unit low noise con-
trol standards
A function to set the control subject of the low noise mode. (A function to set only one of the outdoor unit and the Outdoor unit/Remote control remote control to be able to manage the low noise operation.)
Lamp color
Fine dust stage
display color
Human detection sensor
Humidity Sensing Position
This function selects the LED color to display the fine dust status of the product.
Auto/RGB/YGG
You can change the color display method for each stage of fine dust
according to national standards.
It is the function to set whether to install human detection sensor and
operation standard value.
A function to decide where to detect humidity.
· Type 1: Stage 4 (Republic of Korea) · Type 2: Stage 4 (Global) · Type 3: Stage 6 (China)
Value
Description
Human Detection Sensor
Not installed, default installation, 90° rotated installation
· Type 1: 5 sec, 30 sec, 1 min, 3 min
Sensing Period
· Type 2: 5 sec, 10 sec, 30 sec, 1 min
For Type 2, apply it only when the indoor unit product has the custom
temperature settings function.
Sensitivity Standard, Weak, Power
Keeps operating even when the temperature power saving is complete
· Stage 0: Maintain the product operation and use the temperature powersaving
function.
· Stage 1: Use the temperature power-saving function and stop the operation of
the indoor unit.
Detection Area
Wide, Narrow, Room floor area detection
Remote control/Indoor unit
34
Function
Product
Air Con- Ventiladitioner tion
Description
Outdoor unit cycle priority
You can select standby or cooling.
Option
· Disabled: It does not support the opposite cycle operation with the wired
remote control.
· Cooling: When the user has selected the opposite operation mode by the wired
remote control, the indoor unit stops the heat exchange and the fan.
· Standby: There is a priority on the cooling cycle. When the user has changed
the operation mode of a specific indoor unit into the cooling or heating
cycle, the outdoor unit is switched into the cooling cycle and the indoor unit
maintains the heating operation by using the heater. Before using this
function, please set the emergency heater or external heater function.
Outdoor tem-
perature based
You can set the outdoor temperature
on heater
based on the temperature of the heat-
–
combination
er combination heating mode.
heating
Predicted pow-
er display
A function to set the display of the energy data measured by the outdoor ON/OFF unit.
CN_PTC
This is a function to set PTC Port of indoor unit.
ON/OFF
Temperature Compensation
You can display on the screen by applying the compensation value to the temperature value detected by the remote control.
In case of Celsius: -5 °C to +5 °C (by the unit of 0.5 °C)
In case of Fahrenheit: -10 °F to 10 °F (by the unit of 1 °F)
Humidity Compensation
Compensation value can be applied to the humidity value detected by the re- -10% to +10% (by the unit of 1%) mote control to display on the screen.
Dust concen-
tration display
lamp always on
A function to set whether to regularly display the dust concentration on the LED lamp mounted on the indoor unit product.
ON/OFF
Fan operation
time
A function to display the operation cumulative time of the indoor unit fan motor.
–
35
Function
Product
Air Con- Ventiladitioner tion
Description
Indoor unit operation time
A feature that displays the cumulative time that the indoor unit has been on.
Option –
Indoor Tem-
perature Master/Slave
Setting
A feature that sets the Master/Slave for the temperature sensors for each indoor unit.
· Cancel: Cancel the function.
· Master: Set based on the room temperature.
· Slave: Use the reference temperature of the master indoor unit.
When it is set to Slave, you can set the Master indoor unit address (00-FF).
Indoor unit
physical ad-
dress
Set the physical address of the indoor unit.
–
Floor tempera-
ture detection
for heating
This function sets whether to use the floor temperature detection sensor.
ON/OFF
ESP (External Static Pressure)
Auto
This function can be used for changing the target air volume.
Disabled/+10%/-10%
Fan control when occupied/
vacant
This function automatically sets the rotary speed of the fan in accordance with each stage of the rated air volume for making it easy to install.
–
UVnano
This function sets whether or not UV
LEDs are installed in order to use the Installed/Not installed
UVnano function.
Filter box
A function to set whether to install for using the function of filter box.
Installed/Not installed
A function to reset the password
Password reset
(0000) when the password set on the
–
remote control is not remembered.
Factory Data Reset
A function to reset all the settings, tim er, schedule, and energy information
stored in the remote control.
–
Air supply ESP (External Static
Pressure)
A function to determine the air vol ume value falling under the air supply Set
the RPM value for each fan speed.
volume.
36
Function
Product
Air Con- Ventiladitioner tion
Description
Option
Exhaust ESP (External Static
Pressure)
A function to determine the air volume
value falling under the exhaust air
Set the RPM value for each fan speed.
volume.
Product Direction
A function to set the installation direction of the ventilation indoor unit.
Normal/Opposite
Fast ventilation priority
A function to set the priority of air supply and air exhaust in case of fast
Air supply/Air exhaust
ventilation operation.
Ventilation single humidifi-
cation
A function to set whether to use the
humidification function in case of ventilation single operation of direct-type
ON/OFF
ventilation.
Ventilation heating humidi-
fication
A function to automatically or manually set the heating humidification
function Auto/Manual
of the direct-type ventilation.
Reference air volume
A function to change the reference air Default value/Rise by 10%/Fall by 10%/Fall
volume of ventilation.
by 20%
Filter Check Alarm
A function to set the filter replacement cycle of the ventilation indoor unit.
Stage 0-Stage 5
37
USING THE LG THINQ APP
You can easily change the desired settings through the ThinQ App after
directly connecting the wired remote control to the ThinQ App.
NOTE
· Bluetooth function is not supported.
· To connect the wired remote control to the ThinQ app, select the deluxe
wired controller in the product selection stage.
WI-FI MODULE SPECIFICATIONS
The relevant wireless equipment has a possibility of radio interference. Therefore, any service relating to the safety of life cannot be provided.
Frequency Used
2412MHz ~ 2472MHz
Output (max)
< 10 mW/MHz
OTHER MODE OPERATION/OPEN SOURCE INFORMATION
Other Mode Operation
The other mode operation refers to a phenomenon that appears when the
operation modes differ between indoor units when there are plural indoor units
installed on a single outdoor unit. (The other mode operation does not appear
in the cooling exclusive models.)
1 Example of other mode operation – If plural indoor units are performing
cooling operation on a single outdoor unit, and if only one indoor unit is
controlled to perform heating operation, the indoor unit does not work to
perform heating operation. – If plurality indoor units are performing heating
operation on a single outdoor unit, and if only one indoor unit is controlled
to perform cooling or humidification operation, the indoor unit does not work
to perform cooling or humidification operation.
Open Source Information
To obtain the GPL, LGPL, MPL, and other source codes distributed to open
source licenses for which the source codes shall be disclosed, or to check the
license contents and copyright notices of the open source, please visit
https://opensource.lge.com.
In addition, if a consumer sends an e-mail to opensource@lge.com to request
the open source code of the software installed in this product, LG Electronics
receives the minimum cost required for delivery such as media cost and
transportation cost and contains it in a storage medium to provide it. This
offer is valid for anyone who received this information within 3 years of
selling the product.
38
SELF-DIAGNOSIS/POWER OUTAGE COMPENSATION
Oil Replacement
A function to display the outdoor unit oil change warning when the GHP product
is used. When the below icon appears on the left lower corner of the default
screen, it is the oil change warning status.
CAUTION
· If the oil is not changed, the product cannot work because an error occurs.
NOTE · When the oil change alarm appears, immediately refer to
the mark and contact the service center to change the oil.
UV LED Repair
This function is displayed if UV LED repair is needed when the UVnano model is
in use. UV
NOTE · If the UV alarm is displayed, contact LG Electronics
Service Center for repair.
Failure Mode
When there is a disorder in the product, you can diagnose the failure mode on
your own.
1 It displays the failure mode number on the left lower corner of the default
screen. – But in case of the group control, the failure mode number is
displayed on the left lower corner of the default screen just as for oil
change.
2 When a failure has occurred, please remember the failure number and report
it to the installer/installer store, and you can receive a faster service.
3 Even when a failure has occurred, you can operate the emergency elevation
grill operation. (But, the failure number 03 is excluded.)
In case of central control lock or wired remote control lock is set, it does
not work.
It may not work on some products.
Power Outage Compensation
1 If the power is blocked because of power outage or any other reason, the
previous operation conditions are automatically set by the power outage
compensation function. So you don’t need to press any button. (But, additional
functions do not automatically be set.)
39
CHECKLIST BEFORE REPORTING FAILURE
When there is a problem in the product, check the following items before reporting it to the service center.
Symptoms
Power is not supplied.
The timer operation does not work. No cold wind blows. The remote control
display window displays an error.
The screen has stopped.
Cause
Remedy
Is the air conditioner ON?
· Check the circuit breaker.
· Check the installation status of the wired remote control.
Are the air conditioner and the remote control properly connected to each other by a cable?
· Connect the air conditioner to the remote control cable.
Is the cable connected properly?
· Please check it again by referring to the installation methods in the manual.
Is the time set properly?
· Correctly set the current time.
Did you set the timer correctly?
· Please set it again by referring to the manual.
Is the desired temperature set to be · Set the desired temperature to be lower than lower than the current temperature? the current temperature.
Does the remote control display window displays `CH03′?
· Please check the installation status of the wired remote control again.
· Please check the connection status of the air conditioner and the remote
control cable again.
Has it stopped at the LG logo screen for the booting or after the LG logo
screen?
Does the remote control screen stop or slow during use?
· Please reapply the power for air conditioner indoor unit through the installed circuit breaker.
40
FCC
Notice This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: – Reorient or relocate the receiving antenna. –
Increase the separation between the equipment and the receiver. – Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. – Consult the dealer or an experienced radio/TV
technician for help. This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference and (2) This device must accept any interference
received, including interference that may cause undesired operation. Any
changes or modifications in construction of this device which are not
expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC RF Radiation Exposure Statement This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled environment. This transmitter
must not be co-located or operating in conjunction with any other antenna or
transmitter. This equipment should be installed and operated with a minimum
distance of 20 cm (7.8 inches) between the antenna and your body. Users must
follow the specific operating instructions for satisfying RF exposure
compliance.
Industry Canada Statement This device contains licence-exempt
transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s). Operation is subject to the
following two conditions: (1) This device may not cause interference. (2) This
device must accept any interference, including interference that may cause
undesired operation of the device.
IC Radiation Exposure Statement This equipment complies with IC radiation
exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with a minimum distance of 20 cm (7.8 inches)
between the antenna and your body.
NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE
CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS
COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>