Allied Telesis Release Note Web Based Device GUI Version User Guide

June 2, 2024
Allied Telesis

Allied Telesis Release Note Web Based Device GUI Version

Allied-Telesis-Release-Note-Web-Based-Device-GUI-Version-
product

Specifications

  • Product Name: Web-based Device GUI
  • Version: 2.17.x
  • Supported Models: AMF Cloud, SwitchBlade x8100, SwitchBlade x908 Generation 2, x950 Series, x930 Series, x550 Series, x530 Series, x530L Series, x330-10GTX, x320 Series, x230 Series, x240 Series, x220 Series, IE340 Series, IE220 Series, IE210L Series, SE240 Series, XS900MX Series, GS980MX Series, GS980EM Series, GS980M Series, GS970EMX/10, GS970M Series, AR4000S-Cloud 10GbE UTM Firewall, AR4050S, AR4050S-5G, AR3050S, AR2050V, AR2010V, AR1050V, TQ6702 GEN2-R
  • Firmware Compatibility: AlliedWare Plus versions 5.5.4-x.x, 5.5.3-x.x, or 5.5.2-x.x

Product Usage Instructions

Accessing the Web-based GUI
To access the Web-based GUI:

  1. Ensure your device is powered on and connected to the network.
  2. Open a web browser on a computer connected to the same network.
  3. Enter the IP address of the device in the browser’s addressbar.
  4. Log in using your credentials when prompted.

Updating the Device GUI
To update the Device GUI:

  1. Download the latest version of the GUI from the official website.
  2. Access the device’s management interface through a web browser.
  3. Navigate to the firmware update section.
  4. Upload the downloaded GUI file and follow on-screen instructions to complete the update.

FAQ

  • Q: What firmware versions are compatible with Web-based Device GUI version 2.17.0?
    A: The Web-based Device GUI version 2.17.0 is compatible with AlliedWare Plus firmware versions 5.5.4-x.x, 5.5.3-x.x, or 5.5.2-x.x.

  • Q: How can I access the Web-based GUI of my device?
    A: To access the Web-based GUI, ensure your device is powered on and connected to the network. Open a web browser on a computer connected to the same network, enter the device’s IP address in the browser’s address bar, and log in using your credentials when prompted.

Release Note for Web-based Device GUI Version 2.17.x

Acknowledgments
©2024 Allied Telesis Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the possibility of such damages.
Allied Telesis, AlliedWare Plus, Allied Telesis Management Framework, EPSRing, SwitchBlade, VCStack and VCStack Plus are trademarks or registered trademarks in the United States and elsewhere of Allied Telesis, Inc. Adobe, Acrobat, and Reader are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries. Additional brands, names and products mentioned herein may be trademarks of their respective companies.

Getting the most from this Release Note

To get the best from this release note, we recommend using Adobe Acrobat Reader version 8 or later. You can download Acrobat free from www.adobe.com/

What’s New in Version 2.17.0

  • AMF Cloud
  • SwitchBlade x8100: SBx81CFC960
  • SwitchBlade x908 Generation 2
  • x950 Series
  • x930 Series
  • x550 Series
  • x530 Series
  • x530L Series
  • x330-10GTX
  • x320 Series
  • x230 Series
  • x240 Series
  • x220 Series
  • IE340 Series
  • IE220 Series
  • IE210L Series
  • SE240 Series
  • XS900MX Series
  • GS980MX Series
  • GS980EM Series
  • GS980M Series
  • GS970EMX/10
  • GS970M Series
  • AR4000S-Cloud
  • 10GbE UTM Firewall
  • AR4050S
  • AR4050S-5G
  • AR3050S
  • AR2050V
  • AR2010V
  • AR1050V
  • TQ6702 GEN2-R

Introduction

This release note describes the new features in the Allied Telesis Web-based Device GUI version 2.17.0. You can run 2.17.0 with AlliedWare Plus firmware versions 5.5.4-x.x, 5.5.3-x.x, or 5.5.2-x.x on your device, although the latest GUI features may only be supported with the latest firmware version.
For information on accessing and updating the Device GUI, see “Accessing and Updating the Web-based GUI” on page 8.

The following table lists model names that support this version:
Table 1: Models and software file names

Models Family

AMF Cloud
SBx81CFC960| SBx8100
SBx908 GEN2| SBx908 GEN2
x950-28XSQ| x950
x950-28XTQm|
x950-52XSQ|
x950-52XTQm|
x930-28GTX| x930
x930-28GPX|
x930-28GSTX|
x930-52GTX|
x930-52GPX|
x550-18SXQ x550-18XTQ x550-18XSPQm| x550
Models| Family
---|---
x530-10GHXm| x530 and x530L
x530-18GHXm|
x530-28GTXm|
x530-28GPXm|
x530-52GTXm|
x530-52GPXm|
x530DP-28GHXm|
x530DP-52GHXm|
x530L-10GHXm|
x530L-18GHXm|
x530L-28GTX|
x530L-28GPX|
x530L-52GTX|
x530L-52GPX|
x330-10GTX| x330
x330-20GTX|
x330-28GTX|
x330-52GTX|
x320-10GH x320-11GPT| x320
x240-10GTXm x240-10GHXm| x240
x230-10GP| x230 and x230L
x230-10GT|
x230-18GP|
x230-18GT|
x230-28GP|
x230-28GT|
x230L-17GT|
x230L-26GT|
x220-28GS x220-52GT x220-52GP| x220
IE340-12GT| IE340
IE340-12GP|
IE340-20GP|
IE340L-18GP|
IE220-6GHX IE220-10GHX| IE220
IE210L-10GP IE210L-18GP| IE210L
SE240-10GTXm SE240-10GHXm| SE240
XS916MXT XS916MXS| XS900MX
GS980MX/10HSm| GS980MX
GS980MX/18HSm|
GS980MX/28|
GS980MX/28PSm|
GS980MX/52|
GS980MX/52PSm|
GS980EM/10H GS980EM/11PT| GS980EM
GS980M/52 GS980M/52PS| GS980M
GS970EMX/10| GS970EMX
GS970EMX/20|
GS970EMX/28|
GS970EMX/52|
Models| Family
---|---
GS970M/10PS| GS970M
GS970M/10|
GS970M/18PS|
GS970M/18|
GS970M/28PS|
GS970M/28|
10GbE UTM Firewall
AR4000S Cloud
AR4050S AR4050S-5G AR3050S| AR-series UTM firewalls
AR1050V| AR-series VPN routers
TQ6702 GEN2-R| Wireless AP Router

New Features and Enhancements

This section summarizes the new features in the Device GUI software version 2.17.0.

Enhancements to Device GUI on TQ6702 GEN2-R
Available on: TQ6702 GEN2-R running AlliedWare Plus 5.5.4-0 onwards
From version 2.17.0 onwards, the TQ6702 GEN2-R (Wireless AP router) supports additional Device GUI features.
These newly supported Device GUI features include:

  • Entities – support for selecting bond and VAP interfaces in entities
  • Bridging
  • PPP interface support on Interface Management page
  • IPv6 support for WAN interfaces
  • Dynamic DNS client support
  • IPsec – changing maximum TCP segment size and MTU size on the Interface Management page
  • ISAKMP and IPsec profiles
  • IPsec tunnels (basic tunnel creation)
  • DNS Forwarding

Alongside this, authentication options have been updated on the Security setting of attached clients. You can now select from:

AMF Application Proxy
You can configure the following fields for AMF Application Proxy:

  • AMF Application Proxy Server
  • Critical Mode

MAC Filter + External RADIUS
You can configure the following fields for MAC Filter + External RADIUS:

  • RADIUS Server
  • MAC Authentication Username Separator
  • MAC Authentication Username Case
  • MAC Authentication Password

This feature requires AlliedWare Plus version 5.5.4-0.1 onwards.

Accessing and Updating the Web-based GUI

This section describes how to access the GUI, check the version, and update it.

Important Note : Very old browsers may not be able to access the Device GUI. From AlliedWare Plus version 5.5.2-2.1 onwards, to improve the security of the communication for the Device GUI, ciphersuites which use RSA or CBC based algorithms have been disabled, as they are no longer considered secure. Note that the removal of ciphersuites using those algorithms may prevent some old versions of browsers from communicating with the device using HTTPS.

Browse to the GUI
Perform the following steps to browse to the GUI.

  1. If you haven’t already, add an IP address to an interface. For example: awplus> enable
    • awplus# configure terminal
    • awplus(config)# interface vlan1
    • awplus(config-if)# ip address 192.168.1.1/24
    • Alternatively, on unconfigured devices you can use the default address, which is: « on switches: 169.254.42.42 « on AR-Series: 192.168.1.1
  2. Open a web browser and browse to the IP address from step 1.
  3. The GUI starts up and displays a login screen. Log in with your username and password. The default username is manager and the default password is friend.

Check the GUI version
To see which version you have, open the System > About page in the GUI and check the field called GUI version.
If you have an earlier version than 2.17.0, update it as described in “Update the GUI on switches” on page 9 or “Update the GUI on AR-Series devices” on page 10.

Update the GUI on switches

Perform the following steps through the Device GUI and command-line interface if you have been running an earlier version of the GUI and need to update it.

  1. Obtain the GUI file from our Software Download center. The filename for v2.17.0 of the GUI is:

    • « awplus-gui_554_32.gui
    • « awplus-gui_553_32.gui, or
    • « awplus-gui_552_32.gui
      Make sure that the version string in the filename (e.g. 554) matches the version of AlliedWare Plus running on the switch. The file is not device- specific; the same file works on all devices.
  2. Log into the GUI:
    Start a browser and browse to the device’s IP address, using HTTPS. You can access the GUI via any reachable IP address on any interface.
    The GUI starts up and displays a login screen. Log in with your username and password. The default username is manager and the default password is friend.

  3. Go to System > File Management

  4. Click Upload.Allied-Telesis-Release-Note-Web-Based-Device-GUI-Version- \(2\)

  5. Locate and select the GUI file you downloaded from our Software Download center. The new GUI file is added to the File Management window.
    You can delete older GUI files, but you do not have to.

  6. Reboot the switch. Or alternatively, use a Serial console connection or SSH to access the CLI, then use the following commands to stop and restart the HTTP service: awplus> enable

    • awplus# configure terminal

    • awplus(config)# no service http

    • awplus(config)# service http
      To confirm that the correct file is now in use, use the commands:

    • awplus(config)# exit

    • awplus# show http

Update the GUI on AR-Series devices

Prerequisite : On AR-Series devices, if the firewall is enabled, you need to create a firewall rule to permit traffic generated by the device that is destined for external services. See the “Configuring a Firewall Rule for Required External Services” section in the Firewall and Network Address Translation (NAT) Feature Overview and Configuration Guide.
Perform the following steps through the command-line interface if you have been running an earlier version of the GUI and need to update it.

  1. Use a Serial console connection or SSH to access the CLI, then use the following commands to download the new GUI:
    • awplus> enable
    • awplus# update webgui now

Perform the following steps if you have been running an earlier version of the GUI and need to update it.

  1. Use a Serial console connection or SSH to access the CLI, then use the following commands to download the new GUI: awplus> enable
    awplus# update webgui now

  2. Browse to the GUI and check that you have the latest version now, on the System > About page. You should have v2.17.0 or later.

Verifying the GUI File
On devices that support crypto secure mode, to ensure that the GUI file has not been corrupted or interfered with during download, you can verify the GUI file. To do this, enter Global Configuration mode and use the command:
awplus(config)#crypto verify gui
Where is the known correct hash of the file.
This command compares the SHA256 hash of the release file with the correct hash for the file. The correct hash is listed in the table of Hash values below or in the release’s sha256sum file, which is available from the Allied Telesis Download Center.

Caution If the verification fails, the following error message will be generated: “% Verification Failed”
In the case of verification failure, please delete the release file and contact Allied Telesis support.

If you want the device to re-verify the file when it boots up, add the crypto verify command to the boot configuration file.

Table: Hash values

Firmware Version GUI File Hash
5.5.4-x.x awplus-gui_554_32.gui

b3750b7c5ee327d304b5c48e860b6d71803544d8e06fc454c14be25e7a7325f4
5.5.3-x.x| awplus-gui_553_32.gui| b3750b7c5ee327d304b5c48e860b6d71803544d8e06fc454c14be25e7a7325f4
5.5.2-x.x| awplus-gui_552_32.gui| b3750b7c5ee327d304b5c48e860b6d71803544d8e06fc454c14be25e7a7325f4

C613-10607-00-REV A
Release Note for Device GUI version 2.17.0

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Allied Telesis User Manuals

Related Manuals