XEAST XE-26 Infrared Thermal Imager User Manual

June 2, 2024
XEAST

XEAST XE-26 Infrared Thermal Imager User Manual
Infrared Thermal Imager

Safety

Before operating this instrument, please readthefollowing

instructions and use them according to the specifications. Do not use this instrument in explosive, steam, humidor corrosive environment.

Use of environmental conditions

  1. Relative humidity less than 80%RH(non-condensation)
  2. Operating temperature -5~40℃/23~104℉

Maintenance and cleaning

  1. Repair or repair shall be carried out byprofessionals,not by instructions alone.
  2. Clean the case with cloth regularly. Donor usesolventor detergent to clean this form.

Safety Symbol
CE Icon Compliance with European CEsafetystandards

Description

This instrument is an infrared thermal imager which combines surface temperature measurement withreal-timethermal image. The traditional single -point infrared thermometer needs to measure each component onebyone, while the thermal image does not needtodoso, thus saving the measurement time. Potential problemscanbeclearly displayed on the color display screen,whichhelpsusers quickly and accurately locate the center point to measure the cursor and temperature.

In order to increase the recognition, the product isalsoequipped with a visual camera.according totheneed,theimage can be mixed from the whole thermal imagetothewhole visual image. Hot and visible images canbesaved to the memory card.callable images areusedtogenerate reports and print. The product is easytouseand can be tested within seconds after opening.thisproduct is an ideal choice for electricians and maintenance technicians, and can be usedtoquicklyfind the problem area.

Features

  1. TFT full view color screen display
  2. Dual MCU processors, refresh faster
  3. Hot and cold point temperature markers can guide users to the areas with the highest and lowest temperature in the thermal image.
  4. Selectable palette
  5. Hybrid imaging of visual and infrared images
  6. Images capture saved in SD card
  7. Connecting PC with USB can read the image stored in instrument directly.
  8. Connect USB with other power supply and meter, USB can power supply to meter directly

Technical Data

| XE-26| XE-27
---|---|---
Infrared temperature range| -20~380℃/-4~716℉
*** Infrared temperature accuracy| >0℃;±2% or reading±2℃/3.6℉<0℃;±3℃/5.4℉Note:Accuracy is measured in an environment of 18-28℃
Ambient temperature range| N/A| -20~70℃/-4~158℉
Ambient temp erratum re accuracy| N/A| ±1.0℃/1.8℉
Ambient humidity range| N/A| 0~100%RH
Ambient humidity accuracy| N/A| 35~85%RH; ±5%RH
other ±10%RH
Infrared          image resolution| 33X33
Visual             image resolution| 2 megapixel
Field Angle| 33°×33°
Thermal Sensitivity| 0 . 15℃/0 . 27℉
Emissivity| Adjustable 0 . 1~1 . 0
Image Capture Frequency| 9HZ
Wavelength Range| 8-14um
Focus Mode| Fixed
Palette| Rainbow color, white hot, iron red 1,iron red 2
View Options| Blending of the visual and the infrared from full infrared to full visual in 25 % steps
File Format| BMP
Storage| 8GB Standard 8GB Micro SD card, supporting up to 16GB
Memory View| Scroll all saved images and view them on the screen
Auto Power Off| 3minutes,5minutes,10minutes,are optional
Working Temperature| – 5~40℃/23~104℉
Storage Tempering| – 30~60℃/ – 22~140℉
Relative Humidity| 10~80%RH
Power Supply| 4
LR6 AA battery and USB power supply
Battery life| 12 hours
Weight/size| 200g ±5g excluding battery/ 1989855mm

Meter description

Product Instruction

  1. Infrared imaging lens
  2. Visible light camera
  3. LED lighting
  4. Image capture key
  5. Installation nuts for battery cover and tripod
  6. Up button
  7. Menu key/confirmation key
  8. Down button
  9. Power key/return key
  10. TFT high definition color screen
  11. SD card, USB interface
  12. Temperature and humidity sensor

Key Function Description

“ ” Function: hold down” uttonabout3seconds, and the instrument can be controlledtoturnonand offline setting mode, press” uttontoexit the function

“ “Function: press” button one time, the instrument enters the setting menu interface.Inmenusetting mode, “button to determine the function.

” “Function: in measuring mode, press thiskeytochange the mixed image from Adjust 0%to100%in25%steps.In the main menu mode, press the keytogoup.Insecondary menu mode, to increase the value

” ” Function; in measuring mode, pressthiskeytoadjust the mixed image from0%to 100%, stepsize25%.In the main menu mode, press the key own. IN secondary menu mode, to reduce the value
Key Function Description

Image capture function of trigger key

In measuring mode, press the trigger button, and thescreenwilldisplay the ” ” symbol, indicating that the image will besaved.Ifthe ” ” symbol is displayed, indicating that the imagewasnotsaved.Please check whether the SD card is inserted or full.

SD card with 8GB memory is standard configuration, bandit can support up to 16GB SD card

Standard 8GB SD card, supporting up to 16GBSDcard

Long press the trigger key to turn on and offtheLED lights

main menu description

main menu description

  1. Screen brightness setting
  2. Automatic shutdown setting
  3. Temperature unit setting
  4. Background temperaturecompensationsetting
  5. Memory cardcapacitydisplay
  6. Palette settings
  7. Emissivity setting
  8. MAX/Midpoint temperature ark setting
  9. Ambient humidity/temperature display
  10. Date and time setting
  11. Image storage

.Secondary menu description

Backlight Settings
Backlight Settings

Select the screen brightness setting, as shownintheabovefigure. Press the “MODE” key to confirm,andpressthe”▲” key or the “▼” key to set the brightness of thescreenat 1%~100%. The default value is 80%. Thebiggervalue, the brighter the screen. Select the appropriatethebrightness, press the “power” button to saveandreturntothe menu.

timing automatic shutdown
timing automatic shutdown

Select Timed Auto Shutdown, as shown inthefigureabove. Press “MODE” to confirm, press “▲”or “▼”to set, the default value is off, press “Power” tosaveandreturn to the main menu. Four modes can be set:

  1. OFF : None timed shutdown
  2. 3MIN : Turn off after 3 minutes without operating the instrument.
  3. 5MIN : Turn off after 5 minutes without operating the instrument.
  4. 10MIN : Turn off in 10 minutes without operating the instrument.

Temperature Settings
Temperature Settings

Select the temperature unit setting, as showninthefigureabove. Press the “MODE” key to confirm,presser”▲”key or the “▼” key to set the Celsius ℃andFahrenheit.The default value is Celsius ℃. Press the “Power”keytosave and return to the main menu

Background temperature compensation setting
Background temperature compensation setting

Select the background temperature compensationsetting,as shown in the figure above. Press the ” MODE”keytoconfirm, press the “▲” key or the “▼” ketose . the background temperature compensation range-25.0℃~25.0 ℃ is optional, and the default valueis0℃without temperature compensation. Press the”Power”keyto save and return to the main menu

Memory card capacity display

The Memory Card Capacity option displays onlytheremaining capacity of the existing memory card, asshownin the figure.

palette setting
palette setting

Select the palette settings, as shown in the abovefigure.Press “MODE” to confirm, press “▲” or “▼”toset.Thedefault value is rainbow color. Press “Power’s tosaveandreturn to the main menu. The palette has four modes: rainbow color, white hot color, iron red1, ironred2.

Emissivity setting
Emissivity setting

Select the emissivity setting, as shown in thefigureabove

Press “MODE” to confirm,press “▲” or “▼”toset.Theemissivity range is 0.00~1.00, and the default valueis0.95.Press “Power ” to save and return to the main menu

MAX/MIN point temperature marketing
MAX/MIN point temperature marketing

Select MAX/MIN point temperature marketing, asshownin in the figure above. Press the “MODE”keytoconfirm, press the “▲” key or the “▼”keytoset,thedefault value is on, press the “Power”keytosaveandreturn to the main menu

Ambient humidity/temperature display(onlyIR893 is supported)

The “Ambient Humidity/Temperature Display”optionisthe real-time ambient humidity and temperature, asshownin the figure

Date Time Setting
Date Time Setting

Select the date and time settings, as shown in the figure above. Press “MODE” to confirm, enter the year setting, and press 11 or to adjust; Press the “MODE” key to 11 switch to the month setting, and press the ” key or the 11 “” key to adjust; Press “MODE” to switch to date setting, and press “or” ” to adjust; Press “MODE” 11 key to switch to time setting, and press “A” key or “” key to adjust; Press “MODE” to switch to minute setting, and press “or to adjust. Press the “Power” key to save the time settings in this interface and exit to return to the main menu 11 11

towage Image
towage Image

Select Save Image, as shown in the above figure. Pressthe”MODE” key to confirm, enter the image list, view the  image taken before, press the ” key or the ” key to select the corresponding image, press the “MODE” key to view the image, and then press the ” “key or the “” key to switch the image. Press the “Power” key to exit and return to the image list interface, and then press the “Power” key to return to the main menu.

Attention

All objects radiate infrared energy, which is based on the actual surface temperature and surface radiation coefficient of the object. The product perceives the infrared energy on the surface of the object and uses the data to calculate the estimated temperature. Many common objects and materials (such as painted metal, wood, water, skin and fabric) can radiate energy effectively, so it is easy to obtain relatively accurate measurements. for the surface which is easy to radiate energy (high radiation coefficient), the radiation coefficient is greater than 90% (0.90). this simplification does not apply to glossy surfaces or painted metals because their radiation coefficients are less than 60% (0.60). these materials are not easy to radiate energy and are classified as low radiation coefficient materials. In order to measure the material with lower radiation coefficient more accurately, it is necessary to correct the radiation coefficient. a dusting the radiation value usually enables the product to calculate the actual temperature more accurately.

Emissivity Value of Common Material

Material Emissivity Material Emissivity
Aluminum 0.30 Glass 0.90 to 0.95
Bitumen 0.90~ 0.98 Iron Oxides 0.78 to 0.82
Concrete 0.95 Paint 0.80 to 0.95
Asbestos 0.95 Plastic Cement 0.85 to 0.95
Ceramics 0.90~ 0.95 Paper 0.70 to 0.94
Brass 0.50 Sand 0.90
Brick 0.90 Rubber 0.95
Carbon 0.85 Wood 0.94
Oil Sludge 0.94 Textile 0.94
Frozen Food 0.90 Lead 0.50
Hot Food 0.93 Marble 0.94
Ice 0.96~ 0.98 Cloth (Black) 0.98
Snow 0.83 Gypsum 0.8 0 to 0.90
Human Skin 0.98 Water 0.92 ~ 0.96

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals