BLAKESLEE RC-62 Rack Conveyor Type Dishwasher User Guide
- June 2, 2024
- BLAKESLEE
Table of Contents
BLAKESLEE RC-62 Rack Conveyor Type Dishwasher
MODEL
SPECIFICATION
-
RACK SIZES
- Dish/Glass Rack 20 in x 20 in 500mm x 500mm
- Cutlery Basket 19.25 in x 7 in 500mm x 500mm
- Trays Basket 20 in x 20 in 500mm x 500mm
-
WATER CONSUMPTION
- Per Hour 111 (gal) 420 (L)
-
OPERATING CYCLE AND CAPACITY:
- Racks per hour (Min/Max) 156 / 212
-
TANK CAPACITY
- Pre-Wash 10.6 (gal) 40.1 (L)
- 1st Chemical Wash 21 (gal) 79.5 (L)
-
CYCLE TEMPERATURES
- Pre-Wash 115°F 46°C
- 1st Chemical Wash 165°F 72°C
- Rinse 180°F 82°C
-
WATER REQUIREMENTS
-
Inlet Temperature 140°F 60°C
-
Inlet Temperature 110°F 43°C
(requires 23kW booster) -
Inlet Water Pressure 30-87psi 2.11- 6.12kg/cm²
-
Flow Pressure 15-25psi 1.0-1.8kg/cm²
-
All specifications are dependent on water pressure and temperature
3RD PARTY APPROVALS
BLAKESLEE WARRANTY (USA / CANADA)
Blakeslee dishwashers are warranted for one year from the date of
installation against defective materials and workmanship.
Contact Blakeslee USA for details at service@blakesleeinc.com or 630.532.5021
Blakeslee rack machines are state-of-the-art machines designed to deliver superior cleaning performance and productivity, using the least amount of energy, water, and chemicals. This machine is also available with an optional blower dryer or an integrated heat recovery system. The top-line model with the integrated heat recovery system offers energy savings of 20% over non- equipped models depending on operational and site factors.
FEAFEATURES AND CONSTRUCTION
- Prewash, wash and rinse in a compact size
- Self-cleaning vertical wash pump, protected from electrical overloads
- Two-speed traction system with built-in clutch preventing derailment
- Removable Stainless steel washing and rinsing arms for easier cleaning. Stainless steel surface filters on every tank, easily removable without detaching washing arms, keep the water clean and free from debris
- Radial wash tank sloped to help emptying
- Economizers allow operation only when the rack is detected on that specific area, avoiding any waste of water and energy
- Pressure reducer stabilizes water pressure for an optimal final rinse
- AISI 304 stainless steel boilers, fully insulated to reduce thermal losses
- Available with blower dryer and blower dryer + heat recovery options
- Built-in 15kW final rinse booster heater
- Optional 23kW final rinse booster available for a 70°F rise
- Electronic soft touch panel with IPX5 security level
- Auto timer switches off the machine after a prolonged period of inactivity
- Internal cavity and exterior panels – 304 stainless steel
- Insulated double-skin doors equipped with an anti-drop safety system
- 316 stainless steel tank
- Break Tank safety system to fill the tank and prevent backflow contamination
- Vacuum Breaker to fill the booster prevents the backflow of water and avoids any contamination of the water supply in case of external depression
DIMENSION
RATED POWER
(incoming water temperature at 140°F)
- Pre-Wash. ……………………………….. Pump Rated Power 1 kW
- 1st Chemical Wash …………………… Pump Rated Power 2 kW
- ……………………………………………… Tank Heating Element 14 kW
- Final Rinse ………………………………. Total Booster Power 15 kW
- (incoming water temperature at 110°F – requires optional booster)
- Final Rinse ………………………………. Total Booster Power 23 kW
GENERAL SPECIFICATIONS| RC-62-3| RC-62-3 DR24| RC-62-3
HR| RC-62-3 HR + DR24
---|---|---|---|---
140°F (HIGH TEMP – 40° RISE CONFIGURATION)|
Hot Water Input is Not an Option;
Cold Water Input Only
|
Hot Water Input is Not an Option;
Cold Water Input Only
Total Installed Power (kW)| 31.95| 41.32
Amperage at 208v 3 Phase (AMP)| 91.00| 117.10
Amperage at 220-240v 3 Phase (AMP)| 86.40| 11.40
Amperage at 480v 3 Phase (AMP)| 41.00| 52.70
110°F (70° RISE CONFIGURATION)
Total Installed Power (kW)| 39.95| 49.32| 47.00| 56.37
Amperage at 208v 3 Phase (AMP)| 113.20| 139.30| 132.70| 158.80
Amperage at 220-240v 3 Phase (AMP)| 107.40| 132.40| 120.70| 145.70
Amperage at 480v 3 Phase (AMP)| 50.60| 62.30| 59.30| 71.00
Due to periodic changes in designs, methods, procedures, policies, and regulations, the specifications contained in this document are subject to change without notice. While we exercise good faith efforts to provide accurate information, we are not responsible for errors or omissions in the information provided or conclusions reached as a result of using the specifications. By using the information provided, the user assumes all risks in connection with such use.
Blakeslee USA
- 370 Mills Road
- Waynesboro, Georgia 30830
- Tel: 630.532.5021
- Fax: 630.532.5020
- sales@blakesleeinc.com
- www.blakesleeinc.com
Read User Manual Online (PDF format)