Product Specifications
- Product Name: LED URANUS SERIES HIGH LUMEN
- Model Numbers: ABBHL-18-24W-NW-URA-S, ABBHL-18-24W-NW-URA-SE
- Power: 18-24W
- Class: II (Double insulated electrical appliance)
- Mounting Depth: 40mm
- Manufacturer Websites: www.bramcke.de, www.avidelighting.com
Product Usage Instructions
- Turn counterclockwise to open and take out the mounting parts.
- Mark the hole point, fix the screws and expansion plugs into the wall with depth 40mm. Pass the wire.
- Align the tip with the arrow on the fixture and press firmly.
- Install the lamp into mounting parts.
HD011S Sensor Settings
- On/off control: Switch UP for settings, Switch DOWN for adjustments.
- Detection area: Adjust the detection area for movement sensing.
- Hold time: Set the period of light keeping 100% brightness after objects leave.
- Daylight threshold: Adjust ambient brightness settings for sensor activation.
Mounting Height Guidelines
- Ceiling Mounted
- Typical installation height is between 2.5-4m for optimal performance.
- Detection coverage ensures well-covered areas based on height and sensitivity settings.
Application
Auto ON/OFF function: Light turns on when movement is detected and off after people leave, ideal for corridors and staircases.
Frequently Asked Questions
- Q: What is the typical power range for this LED URANUS SERIES product?
- A: The power range for this product is between 18-24 watts.
- Q: How do I adjust the detection area of the HD011S Sensor?
- A: To adjust the detection area, refer to the settings provided and ensure proper positioning for optimal coverage.
- Q: Can the product be used outdoors?
- A: It is recommended to check the product specifications and suitability for outdoor use before installation.
Installation
- Turn counterclockwise to open and take out the mounting parts.
- Mark the hole point, fix the screws and expansion plugs into the wall with a depth 40mm. Pass the Wire
- Install the lamp into mounting parts
Safety instructions
- Before starting installation work, make sure to disconnect the power, or the power cable from the main.
- The assembly, installation and maintenance of electrical installations may only be performed by a qualified person.
- When drilling the holes for the installation, make sure the pipes and wires in the wall are not damaged.
- Damaged products are not allowed to put into operation! There is a risk of electric shock!
- In case of any damage, disconnect the product from the main – immediately.
- Maintenance and repairs must be performed by a qualified person, otherwise the warranty expires.
- The lamp is only approved for its intended use. Technical changes are not allowed.
- Lamps may not be covered! RISK OF FIRE!
- The minimum distance of the lamp to the illuminated surface is >= 0.5m
- The lamps and accessories contain small parts. Keep them away from children.
- The manufacturer assumes no liability for damages incurred as a result of improper use.
Class II:
- A Class II or double-insulated electrical appliance is one which has been designed in such a way that it does not require a safety connection to the electrical earth (ground).
- Waste equipment must not be collected separately or disposed of with household waste because it may contain components hazardous to the environment or health. Used or waste equipment may be dropped off free of charge at the point of sale, or at any distributor which sells equipment of identical nature and function. Dispose of products at a facility specializing in the collection of electronic waste. By doing so, you will protect the environment as well as the health of others and yourself. If you have any questions, contact the local waste management organization. We shall undertake the tasks pertinent to the manufacturer as prescribed in the relevant regulations and shall bear any associated costs arising.
HD011S Sensor
Settings
- Detection area
- In this area, movement will be detected and able to trigger the sensor.100% detection area is also known as the strong sensitivity
- Hold-time
- The period of light keeping 100% brightness after moving objects leave the detection area
- Daylight threshold
- Definition of the ambient brightness; only when the ambient brightness is lower than the preset specific lux amount, the sensor will work; when it’s preset as “disable”, the sensor works every time it detects motion regardless the ambient brightness.
Detection coverage
- Typical installation height 2.5-4m
- This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.
Application
- Auto ON/OFF function
- Light on when detecting movement and off after people leave at night. Applications: Corridor, Staircase.
- With sufficient daylight, even when motion is detected, the light remains OFF.
- With insufficient daylight, when motion is detected, light is ON
- After the last detection and the present hold time elapsed, the light is OFF.
- No daylight function
- The daylight threshold is set to “Disable”.
- Light on when detecting movement, After people leave, Light off after holding on time.
- Applications: Dim places such as Basement Parking and underpass.
For technical or warranty support, please contact the authorised representative
Bramcke GmbH
- 52353 Düren
- A Gut Nazareth 18A
- Germany
- www.bramcke.de