V-TAC 10-R LED Rechargeable Light Instruction Manual
- May 15, 2024
- V TAC
Table of Contents
INSTRUCTION MANUAL
LED RECHARGEABLE LIGHT
TECHNICAL DATA
MODEL | VT-10-R | ON/OFF CYCLE | >15,000 |
---|---|---|---|
SKU | 20038, 503 | LIFE SPAN | 25,000 Hours |
WATTS | 10W | CRI | >80 |
LUMENS@WIDE CONE | 700/350 Lm | DF | >0.5 |
BEAM ANGLE | 100° | IP RATING | IP44 |
BATTERY | 3.7V, Li-Ion, 3600 mAh | BODY COLOUR | Green+Black |
DIMENSION | 175x125mm | FUNCTION | 100%-50% |
INTRODUCTION & WARRANTY
Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best. The warranty is valid for 2 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 Hours Daily operation. Usage of product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only.
WARNING
- To reduce the risk of injury, user must read and understand instruction manual.
- Always make sure the light is off and complete cool before attempting to clean it.
This marking indicates that this product should not be disposed of with other household wastes.
MULTI-LANGUAGE MANUAL QR CODE
Please scan the QR code to access the manual in multiple languages.
In case of any query/issue with the product, please reach out to us at:
support@v-tac.eu
For More products range, inquiry please contact our distributor or nearest
dealers. V-TAC EUROPE LTD. Bulgaria, Plovdiv 4000, bul.L.Karavelow 9B
SAFETY INSTRUCTIONS FOR BATTERIES
Batteries
- Never attempt to open for any reason.
- Do not store in locations where the temperature may exceed 40 °C.
- Charge only at ambient temperatures between 4 °C and 40 °C.
- Charge only using the charger provided with the tool.
- When disposing of batteries, follow the instructions given in the section “Protecting the environment”.
- Do not cause short circuits. If connection is made between the positive (+) and negative (-) terminal directly or via accidental contact with metallic objects, the battery is short circuited and an intense current will flow causing heat generation which may lead to casing rupture or fire.
- If batteries are heated to above 100°C, sealing and insulating separators and other polymer components may be damaged resulting in electrolyte leakage and/or internal short circuiting leading to heat generation causing rupture or fire. Moreover do not dispose of the batteries in fire, explosion and/or intense burning may result.
- Under extreme conditions, battery leakage may occur. When you notice liquid on the battery, proceed as follows:
• Carefully wipe the liquid off using a cloth. Avoid skin contact.
• In case of skin or eye contact, follow the instructions below:
i. Immediately rinse with water. Neutralize with a mild acid such as lemon juice or vinegar.
ii. In case of eye contact, rinse abundantly with clean water for at least 10 minutes. Consult a physician.
Fire hazard! Avoid short-circuiting the contacts of a detached battery. Do not incinerate the battery.
SAFETY INSTRUCTIONS FOR CHARGER
- Use the charger provided with the tool only to charge the battery
- Never attempt to charge non-rechargeable batteries.
- Have defective cords replaced immediately.
- Do not expose to water.
- Do not open the charger.
- Do not probe the charger.
SAFETY WARNING
This is not a toy; children should not permit to use it. This is a DIY
product, all electronic parts fixed already, any intention of opening the
light or changing the design of the floodlight is prohibitive.
Do not attempt to replace or change or the diode lights! If the protective
glass is cracked or broken, It must be replaced before the Rechargeable
Floodlight can be used again.
MAJOR COMPONENTS
- Rechargeable Floodlight head
- LED lamp assembly
- Portable bracket
- Protective cover
- Micro socket
- LED indicator
- ON/OFF switch with mode function
BRACKET ADJUSTMENT
The LED Rechargeable Floodlight’s portable bracket (3) is adjustable (Max.
45°). Adjust the bracket to the suitable position before using.
NOTE: Do not exceed the adjustable stands range as will lead to damaging
the bracket
OPERATION
Charging the Rechargeable
- Open the protective cover (4) and push the micro plug (a) into micro socket (6).(Refer to Fig. 2)
- Plug the adapter into a suitable mains outlet. Do not use an extension cord.
- When the battery is loaded, three LED indicators (6) all illumine (Red light, yellow light and green light light up in sequence). (Refer to Fig. 2)
NOTE: Close the protective cover after full charge which to avoid water
enter. (Refer to Fig. 2)
NOTE: The LED indicator only will show red that means it’s batteries will
soon run out and need to recharge.
SWITCH ON/OFF AND LUMEN ADJUSTMENT (See Fig. 2)
The Rechargeable Floodlight is equipped with an ON/OFF switch with mode
function (7) locate on the back side of the Rechargeable Floodlight.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>