RCF COMPACT M SERIES Two Way Speakers Owner’s Manual

June 4, 2024
RCF

COMPACT M SERIES Two Way Speakers
Owner’s ManualRCF COMPACT M SERIES Two Way
Speakers

COMPACT M SERIES
TWO WAY SPEAKERS

SAFETY PRECAUTIONS AND GENERAL INFORMATION

The symbols used in this document give notice of important operating instructions and warnings which must be strictly followed.

| CAUTION| Important operating instructions: explains hazards that could damage a product, including data loss
---|---|---
| WARNING| Important advice concerning the use of dangerous voltages and the potential risk of electric shock,  personal injury or death.
| IMPORTANT NOTES| Helpful and relevant information about the topic
| SUPPORTS, TROLLEYS
AND CARTS| Information about the use of supports, trolleys, and carts. Reminds us to move with extreme caution and never tilt.
| WASTE DISPOSAL| This symbol indicates that this product should not be disposed of with your household waste, according o the  WEEE directive (2012/19/EU) and your national law.

IMPORTANT NOTES
This manual contains important information about the correct and safe use of the device Before connecting and using this product, please read this instruction manual carefully and keep it on hand for future reference The manual is to be considered an integral part of this product and must accompany it when it changes ownership as a reference for correct installation and use as well as for the safety precautionsRCF S will not assume any responsibility for the incorrect installation and/or use of this product.

SAFETY PRECAUTIONS

  1. All the precautions, in particular the safety ones, must be read with special attention, as they provide important information.

  2. The power supply from mains and The mains voltage is sufficiently high to involve a risk of electrocution; install and connect this product before plugging it in.
    a. Before powering up, make sure that all the connections have been made correctly and the voltage of your mains corresponds to the voltage shown on the rating plate on the unit, if not, please contact your RCF dealer
    b.The metallic parts of the unit are earthed through the power cable An apparatus with CLASS I construction shall be connected to a mains socket outlet with a protective earthing connection Protect the power cable from damage; make sure it is positioned in a way that it cannot be stepped on or crushed by objects /
    e To prevent the risk of electric shock, never open this product: there are no parts inside that the user needs to access.
    Be careful: in the case of a product supplied by the manufacturer only with POWER CON connectors and without a power cord, jointly to POWER CON connectors type NAC3FCA (power-in) and NAC3FCB (power-out), the following power cords compliant to the national standard shall be used:
    – EU: cord type H05VV-F 3G 3×25 mm2- Standard IEC 60227-1
    – JP: cord type VCTF 3×2 mm2; 15Amp/120V~ – Standard JIS C3306
    – US: cord type SJT/SJTO 3×14 AWG; 15Amp/125V~ – Standard ANSI/UL 62

  3. Make sure that no objects or liquids can get into this product, as this may cause a short circuit. This apparatus shall not be exposed to dripping or splashing No objects filled with liquid, such as vases, shall be placed on this apparatus No naked sources (such as lighted candles) should be placed on this apparatus.

  4. Never attempt to carry out any operations, modifications, or repairs that are not expressly described in this manual Contact your authorized service center or qualified personnel should any of the following occur:
    – The product does not function (or functions in an anomalous way).
    – The power cable has been damaged.
    – Objects or liquids have got in the unit.
    – The product has been subject to a heavy impact.

  5. If this product is not used for a long period, disconnect the power cable.

  6. If this product begins emitting any strange odors or smoke, switch it off immediately and disconnect the power cable.

  7. Do not connect this product to any equipment or accessories not foreseen For suspended installation, only use the dedicated anchoring points, and do not try to hang this product by using elements that are unsuitable or not specific for this purpose. Also check the suitability of the support surface to which the product is anchored (wall,  ceiling, structure, etc), and the components used for attachment (screw anchors, screws, brackets not supplied by RCF, etc), which must guarantee the security of the system/installation over time, also considering, for example, the mechanical vibrations normally generated by transducers.  To prevent the risk of falling equipment, do not stack multiple units of this product unless this possibility is specified in the user manual.

  8. RCF S.p.A. strongly recommends this product is only installed by professional qualified installers (or specialized firms) who can ensure correct installation and certify it according to the regulations in force. The entire audio system must comply with the current standards and regulations regarding electrical systems.

  9. Supports, trolleys, and carts.
    The equipment should be only used on supports, trolleys, and carts, where necessary, that are recommended by the manufacturer. The
    equipment / support / trolley/cart assembly must be moved with extreme caution. Sudden stops, excessive pushing force, and uneven floors may cause the assembly to overturn. Never tilt the assembly.

  10. There are numerous mechanical and electrical factors to be considered when installing a professional audio system (in addition to those which are strictly acoustic, such as sound pressure, angles of coverage, frequency response, etc).

  11. Hearing loss.
    Exposure to high sound levels can cause permanent hearing loss. The acoustic pressure level that leads to hearing loss is different from person to person and depends on the duration of exposure. To prevent potentially dangerous exposure to high levels of acoustic pressure, anyone who is exposed to these levels should use adequate protection devices. When a transducer capable of producing high sound levels is being used, it is, therefore, necessary to wear earplugs or protective earphones. See the manual technical specifications to know the maximum sound pressure level.

OPERATING PRECAUTIONS

– Place this product far from any heat sources and always ensure adequate air circulation around it.
– Do not overload this product for a long time.
– Never force the control elements (keys, knobs, etc)
– Do not use solvents, alcohol, benzene or other volatile substances for cleaning the external parts of this product.

IMPORTANT NOTES
To prevent the occurrence of noise on line signal cables, use screened cables only and avoid putting them close to:
– Equipment that produces high-intensity electromagnetic fields
– Power cables
– Loudspeaker lines

WARNING! CAUTION! To prevent the risk of fire or electric shock, never expose this product to rain or humidity.
WARNING! To prevent electric shock hazards, do not connect to the mains power supply while the grille is removed
WARNING! to reduce the risk of electric shock, do not disassemble this product unless you are qualified. Refer servicing to qualified service personnel.

CORRECT DISPOSAL OF THIS PRODUCT

This product should be handed over to an authorized collection site for recycling waste electrical and electronic equipment (EEE). Improper handling of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the effective usage of natural resources. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, waste authority, or your household waste disposal service.

CARE AND MAINTENANCE

To ensure a long-life service, this product should be used following this advice:
– If the product is intended to be set up outdoors, be sure it is under cover and protected from rain and moisture.
– If the product needs to be used in a cold environment, slowly warm up the voice coils by sending a low-level signal for about 15 minutes before sending high-power signals.
– Always use a dry cloth to clean the exterior surfaces of the speaker and always do it when the power is turned off.
CAUTION: to avoid damaging the exterior finishes do not use cleaning solvents or abrasives.
WARNING! CAUTION! For powered speakers, do cleaning only when the power is turned off.
RCF S.p.A. reserves the right to make changes without prior notice to rectify any errors and/or omissions. Always refer to the latest version of the manual on www.rcf.it.

DESCRIPTION

COMPACT M SERIES
The Compact Media series includes a wide range of high-quality 2-way passive loudspeakers for fixed installations and is the ideal solution for small to medium size projects
This series covers 6 models. Models from M 06 to M 12 are equipped with a high power handling ‘Low Impedance Compensated Crossover’, having electronic protection for the driver. The front grilles are made of steel and the front RCF logo is easily rotatable. Several rigging points are available on each model, in order to match with any application needs.
All models have a 4-pin EUROBLOCK connector (audio input and parallel link output).RCF COMPACT M SERIES Two Way Speakers fig 15

CONNECTIONS

RCF COMPACT M SERIES Two Way Speakers fig 14

Connect the positive wire (amplifier ‘+’ output) to the pin ‘INPUT +’ of the 4-pin EUROBLOCK connector.
Connect the negative wire (amplifier ‘–’ output) to the pin ‘INPUT –’ of the 4-pin EUROBLOCK connector.
The ‘LINK +’ and ‘LINK –’ pins are useful to link another loudspeaker in parallel.
The impedance value of each loudspeaker is 8 Ω.
WARNING! CAUTION! Loudspeaker connections should be only made by qualified and experienced personnel having the technical know-how or enough specific instructions (to ensure that connections are made correctly) in order to prevent any electrical danger.
To prevent any risk of electric shock, do not connect loudspeakers when the amplifier is switched on. Before turning the system on, check all connections and make sure there are no accidental short circuits. The entire sound system shall be designed and installed in compliance with the current local laws and regulations regarding electrical systems.
The entire sound system shall be designed and installed in compliance with the current local laws and regulations regarding electrical systems.
WARNING! CAUTION! Loudspeakers are to be installed by qualified personnel, respecting all safety standards.
Loudspeakers are to be installed securely.
Make sure the support structure (walls/ceilings) has the necessary mechanical characteristics for the loudspeaker weight,
without the risk of a fall that could damage things or cause an injury.
Use attachment elements suitable for walls/ceilings (e.g. wall plugs for bricks, for concrete, etc.).

HORIZONTAL MOUNTING WITH U BRACKET

Necessary optional accessory:
– HORIZONTAL BRACKET H-BR 2X COMPACT M 08 (for COMPACT M 08 model);
– HORIZONTAL BRACKET H-BR 2X COMPACT M 10 (for COMPACT M 10 model);
– HORIZONTAL BRACKET H-BR 2X COMPACT M 12 (for COMPACT M 12 model);

  1. Fix the U bracket to the wall/ceiling through at least 4 lateral wall plugs (max. M8) plus a central one (max. M10).
  2. Mount the U bracket to the loudspeaker by tightening the two M10x35 bolts into the holes of the loudspeaker top and bottom, as shown in the figure below.

RCF COMPACT M SERIES Two Way Speakers fig 13

Alternatively, it’s possible to install the speaker in a less protruding way by using the other two inner holes on the U bracket.
Before tightening the two M10 bolts, adjust the loudspeaker’s vertical tilt and then (when you found the right angle) fix it through two M4.2×22 self- threading screws (passing through the small hole of the U bracket) directly into the loudspeaker cabinet wood.
NOTE: instead of simple M10 bolts, it is possible to use the M10 bolt- included knobs.
CAUTION: do not tilt the loudspeaker upwards.
Model COMPACT M 04 comes with its own HORIZONTAL BRACKET wich must be fixed in the same way as the other COMPACT M models (see picture below).RCF COMPACT M
SERIES Two Way Speakers fig 12

VERTICAL MOUNTING WITH U BRACKET

Necessary optional accessory:
– VERTICAL BRACKET V-BR 2X COMPACT M 08 (for COMPACT M 08 model);
– VERTICAL BRACKET V-BR 2X COMPACT M 10 (for COMPACT M 10 model);
– VERTICAL BRACKET V-BR 2X COMPACT M 12 (for COMPACT M 12 model);
Fix the U bracket to the wall/ceiling through at least 4 lateral wall plugs (max. M8) plus a central one (max. M10).RCF COMPACT M SERIES Two Way
Speakers fig 11

  1. After removing the screwes on the speaker sides, fix the angular adaptor on the speaker with the M8x45 screws.
  2. Place the plastic cover on the angular adaptor.
  3. Fix the bracket to the speaker with the M10x30 screws placing a grower washer between the bracket and the plastic cover.

Set the speaker’s vertical tilt and fix the inclination by screwing the two M6 screws on the adaptor.
NOTE: alternatively, a less protruding installation is possible thanks to the inner holes of the U bracket.
CAUTION: do not tilt the loudspeaker upwards.

MOUNTING WITH A SWIVEL BRACKET

Necessary optional accessory: WALL MOUNT BRACKET SWM-BR COMPACT M (for COMPACT M 05, M 06, and M 08 models)

  1. Install the fixed part of the accessory with 4 M8 wall plugs through the 4 holes (the central area of the fixed part can be useful to let pass the connecting cable from the wall outlet)

  2. Fix the SUPPORT BRACKET to the FIXED PART with two M10 bolts included in dotazione and choose the right inclination angle (0°, 15°, 30°, 45°)
    The MOVING PART of the accessory must be fixed directly on the back of the speaker with 4 M6 flat head screws (already placed on the , speaker).On the COMPACT M 08 model, the accessory can be fixed in two different positions (as shown in the picture below).
    RCF COMPACT M SERIES Two Way Speakers fig 8It is also possible the loudspeaker horizontal mounting (see the figure below).
    RCF COMPACT M SERIES Two Way Speakers fig 7

  3. Then, place the speakers on the support bracket and tighten the two lateral bolts.

NOTES ABOUT LOW-IMPEDANCE CONNECTIONS

RCF COMPACT M SERIES Two Way Speakers fig 6

WARNING!
CAUTION!

– The total loudspeaker impedance must not be lower than the amplifier output impedance.
Note: a loudspeaker total impedance equal to the amplifier output one permits to get the maximum deliverable power (but a higher loudspeaker impedance entails less power).
– The total loudspeaker power shall be adequate for the maximum deliverable power of the amplifier.
– The loudspeaker line shall be short (for long distances, it may be necessary to use cables with large cross-section wires).
– Always use cables having wires with an adequate cross-section, considering the cable length and the total loudspeaker power.
– Loudspeaker lines must be kept separated from the mains cables, microphone cables or others, in order to avoid inductive phenomena may cause hum or noises.
– Use loudspeaker cables with twisted wires to reduce hum caused by inductive effects due to coupling with electromagnetic fields.
– Do NOT connect the low impedance input directly to 70 / 100 V constant voltage lines.

DIMENSIONS

COMPACT M 04RCF COMPACT M SERIES Two Way Speakers fig
5

COMPACT M 05RCF COMPACT M SERIES Two Way Speakers fig
4 COMPACT M 06RCF COMPACT M SERIES Two Way
Speakers fig 3 COMPACT M 08RCF COMPACT M SERIES Two
Way Speakers fig 2

COMPACT M 10RCF COMPACT M SERIES Two Way Speakers fig
1 COMPACT M 12RCF COMPACT M SERIES Two Way
Speakers fig

SPECIFICATIONS

ACOUSTICAL SPECIFICATION| COMPACT M 04| COMPACT M 05| COMPACT M 06| COMPACT M 08| COMPACT M 10| COMPACT M 12
---|---|---|---|---|---|---
Frequency Response (-10dB)| 90 Hz ÷ 20000 Hz| 70 Hz ÷ 20000 Hz| 60 Hz ÷ 20000 Hz| 60 Hz ÷ 20000 Hz| 60 Hz ÷ 20000 Hz| 55 Hz ÷ 20000 Hz
Max SPL @ 1m (dB)| 113 dB| 115 dB| 116 dB| 124 dB| 128 dB| 129 dB
Coverage angle H x V| 120° x 120°| 120° x 80°| 120° x 80°| 90° x 70°| 90 x 70°| 90 x 70°
Directivity Index Q| 6| 7| 7| 9| 9| 9
Sensitivity (dB)| 89 dB| 89 dB| 90 dB| 95 dB| 98 dB| 98 dB

POWER SECTION

Nominal Impedance (ohm) 16 ohm 8 ohm 8 ohm 8 ohm 8 ohm 8 ohm
Power (RMS) 60 W RMS 80 W RMS 100 W RMS 200 W RMS 300 W RMS 300 W RMS
Power (PEAK) 240 W PEAK 320 W PEAK 400 W PEAK 800 W PEAK 1200 W PEAK

1200 W PEAK
Reccommended Amplifier| 120 W| 160 W| 200 W| 400 W| 600 W| 600 W
Crossover Frequency| 3500 Hz| 2200 Hz| 2200 Hz| 1800 Hz| 1800 Hz| 1800 Hz
Protections| –| –| Dynamic active MOSFET| Dynamic active MOSFET| Dynamic active MOSFET| Dynamic active MOSFET

TRANSDUCERS

HIGH FREQUENCY| 1” neo, 1.0” v.c(dometweeter)| 1” neo, 1.0” v.c(domtweeter)| 1” neo, 1.0” v.c(dometweeter)| 1” neo, 1.0” v.c(compression driver)| 1” neo, 1.0” v.c(compression driver)| 1” neo, 1.0” v.c(compression driver)
---|---|---|---|---|---|---
Nominal Impedance (ohm)| 16 ohm| 8 ohm| 8 ohm| 8 ohm| 8 ohm| 8 ohm
Nominal power| 10 W AES, 20 W PEAK| 15 W AES, 30 W PEAK| 15 W AES, 30 W PEAK| 25 W AES, 50 W PEAK| 25 W AES, 50 W PEAK| 25 W AES, 50 W PEAK
Sensitivity (dB, 1W @ 1m)| 91 dB, 1W @ 1m| 92 dB, 1W @ 1m| 92 dB, 1W @ 1m| 107 dB, 1W @ 1m| 107 dB, 1W @ 1m| 107 dB, 1W @ 1m
WOOFER| 4.0”, 1” v.c| 5.0”, 1.2” v.c| 6.0”, 1.5” v.c| 8”, 1.7” v.c| 10”, 2.5” v.c| 12”, 2.5” v.c
Nominal Impedance (ohm)| 16 ohm| 8 ohm| 8 ohm| 8 ohm| 8 ohm| 8 ohm
Nominal power| 40 W AES, 80 W PEAK| 80 W AES, 160 W PEAK| 100 W AES, 200 W PEAK| 200 W AES, 400 W PEAK| 300 W AES, 600 W PEAK| 300 W AES, 600 W PEAK
Sensitivity (dB, 1W @ 1m)| 88 dB, 1W @ 1m| 89 dB, 1W @ 1m| 90 dB, 1W @ 1m| 94 dB, 1W @ 1m| 98 dB, 1W @ 1m| 98 dB, 1W @ 1m

INPUT/OUTPUT SECTION

Input/Output connectors| Euroblock| Euroblock| Euroblock| Euroblock| Euroblock| Euroblock
---|---|---|---|---|---|---

PHYSICAL SPECIFICATION

Cabinet Material Plywood Plywood Plywood Plywood Plywood Plywood
Hardware 2 x M6, 2 x M8 4 x M6, 2 x M8 4 x M6, 2 x M8 6 x M6, 4 x M8, 2 x
M10 8 x M8, 8 x M10 8 x M8, 8 x M10
Grille Steel with clothing Steel with clothing Steel with clothing Steel
with clothing Steel with clothing Steel with clothing
Color Black Black / White Black / White Black / White Black / White

Black / White

DIMENSION

Height| 148 mm / 5.83 inches| 303 mm /1193 inches| 365 mm / 14.37 inches| 442 mm / 17.4 inches| 510 mm / 20.08 inches| 620 mm / 24.41 inches
---|---|---|---|---|---|---
Width| 132 mm / 5.2 inches| 172 mm / 67.7inches| 211 mm /8.31inches| 257 mm / 10.12 inches| 295 mm / 11.61 inches| 362 mm / 14.25 inches
Depth| 145 mm / 5.71 inches| 191 mm / 7.52 inches| 232 mm / 9.13 inches| 284 mm/11.18 inches| 325 mm /12.8inches| 404 mm / 15.91 inches
Weight| 2.3 kg / 5.07 lbs| 4.5 kg / 9.92 lbs| 5.5 kg / 12.13 lbs| 13.5 kg / 29.76 lbs| 17 kg / 37.48 lbs| 22 kg/48.5 lbs

RCF S.p.A. Via Raffaello Sanzio, 13
– 42124 Reggio Emilia – Italy
Tel +39 0522 274 411
– Fax +39 0522 232 428
– e-mail: info@rcf.it
www.rcf.it

References