AIREFRIGA W2S130-AA03-63 Compact Axial Fan Instruction Manual
- May 15, 2024
- AIREFRIGA
Table of Contents
AIREFRIGA W2S130-AA03-63 Compact Axial Fan
SAFETY REGULATIONS
SAFETY REGULATIONS AND INFORMATION
- Read these operating instructions carefully before starting work on the device. Observe the following warnings to prevent malfunctions or danger to persons.
- These operating instructions are to be regarded as part of the device. The device is only to be sold or passed on together with the operating instructions.
- These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention.
Hazard levels for warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation that will result in death or
serious injury if the specified actions are not taken. Compliance with the
instructions is imperative.
WARNING
Indicates a potentially hazardous situation that can result in death or
serious injury if the specified actions are not taken. Exercise extreme
caution while working.
CAUTION
Indicates a potentially hazardous situation that can result in minor or
moderate injury or damage to property if the specified actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can lead to
property damage.
Staff qualifications
The device may only be transported, unpacked, installed, operated, maintained,
and otherwise used by suitably qualified, trained, and authorized technical
staff.
Only authorized specialists are permitted to install the device, carry out a
test run, and perform work on the electrical installation.
Basic safety rules
- The safety hazards associated with the device must be assessed again following installation in the final product.
- The locally applicable industrial safety regulations are always to be observed when working on the device.
- Keep the workplace clean and tidy. Untidiness in the work area increases the risk of accidents.
- Note the following when working on the device:
- Do not perform any modifications, additions, or conversions on the device without the approval of ebm-papst.
Voltage
- Check the device’s electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
- Replace loose connections and defective cables immediately.
DANGER
Electrically charged device Risk of electric shock
- When working on an electrically charged device, stand on a rubber mat.
WARNING
Live terminals and connections even with the device switched off Electric
shock
- Wait five minutes after disconnecting the voltage at all poles before opening the device.
CAUTION
- In the event of a fault, the rotor and the impeller will be energized
The rotor and the impeller have basic insulation.
- Do not touch the rotor and impeller once installed.
CAUTION
The motor restarts automatically when operating voltage is applied, e.g. after
a power failure.
Risk of injury
- Keep out of the device’s danger zone.
- When working on the device, switch off the line voltage and ensure that it cannot be switched back on.
- Wait until the device comes to a stop.
Safety and protective features
DANGER
- The protective device missing and protective device not functioning
- Without a protective device, there is a risk of serious injury, for instance when reaching into the device during operation.
- Operate the device only with a fixed protective device and guard grille.
- The fixed protective device must be able to withstand the kinetic energy of a fan blade that becomes detached at maximum speed. There must not be any gaps which it is possible to reach into with the fingers, for example.
- The device is a built-in component. As the operator, you are responsible for ensuring that the device is secured adequately.
- Stop the device immediately if you notice a missing or ineffective protective device.
Mechanical movement
DANGER Rotating device
Risk of injury to body parts coming into contact with the rotor or the
impeller.
- Secure the device against accidental contact.
- Before working on the system/machine, wait until all parts have come to a standstill.
WARNING: Rotating device
Long hair and dangling items of clothing, jewelry, and the like can become
entangled and be pulled into the device. Injuries can result.
- Do not wear any loose-fitting or dangling clothing or jewelry while working on rotating parts.
- Protect long hair with a cap.
Emissions
WARNING: Depending on the installation and operating conditions, the sound pressure level may exceed 70 dB(A).
- Risk of noise-induced hearing loss.
- Take appropriate technical safety measures.
- Protect operating personnel with appropriate safety equipment such as hearing protection.
- Also, observe the requirements of local agencies.
Hot surface
CAUTION: High temperature on motor housing Risk of burns
- Ensure sufficient protection against accidental contact.
Transport
NOTE: Transporting the device
- Transport the device in its original packaging only.
- Secure the device so it cannot slip, e.g. by using a lashing strip.
Storage
- Store the device, partially or fully assembled, in a dry place, protected against the weather and free from vibration, in the original packaging in a clean environment.
- Protect the device against environmental effects and dirt until final installation.
- We recommend storing the device for no longer than one year to guarantee trouble-free operation and the longest possible service life.
- Even devices explicitly intended for outdoor use are to be stored as described before commissioning.
- Maintain the storage temperature, see Chapter 3.5 Transport and storage conditions.
INTENDED USE
The device is exclusively designed as a built-in device for conveying air
according to its technical data.
Any other usage above and beyond this does not conform with the intended
purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical and thermal
stresses that can arise from this product. This applies to the entire service
life of the equipment in which this product is installed.
Intended use also includes
- Conveying air at an ambient air pressure between 800 mbar and 1050 mbar.
- Using the device within the permitted ambient temperature range; see Chapter 3.5 Transport and storage conditions and Chapter 3.2 Nominal data.
- Operating the device with all protective devices.
- Following the operating instructions.
Improper use
In particular, operating the device in the following ways is prohibited and
could be hazardous:
- Operating the device in an unbalanced state, e.g. due to dirt deposits or ice formation.
- Resonant operation, operation with severe vibration. This also includes vibration transmitted to the fan from the customer installation.
- Operation in medical equipment with a life-sustaining or life-support function.
- Conveying solids in the flow medium.
- Painting the device
- Connections (e.g. screws) coming loose during operation.
- Conveying air that contains abrasive particles.
- Conveying highly corrosive air, e.g. salt spray. Exception: devices designed for salt spray and correspondingly protected.
- Conveying air with high dust content, e.g. suctioning off sawdust.
- Operating the device close to flammable materials or components.
- Operating the device in an explosive atmosphere.
- Using the device as a safety component or to perform safety-related functions.
- Operation with completely or partially disassembled or manipulated protective devices.
- In addition, all applications are not listed among the intended uses.
TECHNICAL DATA
Product Drawing
All dimensions in mm.
1 | The direction of airflow “V” |
---|---|
2 | Cable PVC 3G 0.5 mm², 3x crimped splices |
Nominal data
Motor | M2S052-CA |
---|---|
Phase | 1~ |
--- | --- |
Nominal voltage / VAC | 230 |
Frequency / Hz | 50 |
Method of obtaining data | fa |
--- | --- |
Valid for approval/ standard | CE |
Speed (rpm) / min -1 | 2800 |
Power consumption / W | 45 |
Current draw / A | 0.31 |
Max. back pressure / Pa | 80 |
Min. ambient temperature / °C | -25 |
Max. ambient temperature / °C | 50 |
Starting current / A | 0.45 |
- ml = Max. load ·
- me = Max. efficiency ·
- fa = Free air
- cs = Customer specification ·
- ce = Customer equipment
Subject to change
Technical description
Weight | 1.1 kg |
---|---|
Size | 130 mm |
Motor size | 52 |
Rotor surface | Rotor open, painted black |
Blade material | Sheet steel, painted black |
Fan housing material | Die-cast aluminum, painted black |
Number of blades | 7 |
Airflow direction | V |
Direction of rotation | Counterclockwise, viewed toward rotor |
Degree of protection | IP20 |
Insulation class | “B” |
Moisture (F) / Environmental (H) protection class | H0+ |
Installation position | Any |
Condensation drainage holes | None, open rotor |
Mode | S1 |
Motor bearing | Ball bearing |
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN
system)| < 0.75 mA
Motor protection| Thermal overload protector (TOP) internally connected
Protection class| I (with customer connection of protective earth)
Conformity with standards| EN 60335-1; CE
INFO: About cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load cycles. If you have special questions, consult ebm-papst for support.
Use the device by its degree of protection.
Information on surface quality
The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period. This
has no effect on strength, dimensional stability, and dimensional accuracy.
The color pigments in the paints used perceptibly react to UV light over time.
This does not however in any way affect the technical properties of the
products. The product is to be protected against UV radiation to prevent the
formation of patches and fading. Color changes are not a reason for complaint
and are not covered by the warranty.
Mounting data
- Secure the screws against unintentional loosening (e.g. use self-locking screws).
- For screw clearance, see Chapter 3.1 Product drawing
Strength class of screws | 8.8 |
---|
Any further mounting data required can be taken from the product drawing or Section Chapter 4.1 Mechanical connection.
Transport and storage conditions
Max. permitted ambient temp. for motor (transport/ storage) | + 80 °C |
---|---|
Min. permitted ambient temp. for motor (transport/ storage) | – 40 °C |
CONNECTION AND STARTUP
Mechanical connection
CAUTION
-
Cutting and crushing hazard when removing the device from the packaging
-
Blades can bend
-
Carefully remove the device from its packaging, by the fan housing. Strictly avoid shocks.
-
Wear safety shoes and cut-resistant safety gloves.
NOTE: Damage to the device from vibration Bearing damage, shorter service life -
The fan must not be subjected to force or excessive vibration from sections of the installation.
-
If the fan is connected to air ducts, the connection should be isolated from vibration, e.g. using compensators or similar elements.
-
Ensure stress-free attachment of the fan to the substructure.
- Check the device for transport damage. Damaged devices are not to be installed.
- Install the undamaged device by your application.
CAUTION
- Possible damage to the device
- If the device slips during installation, serious damage can result.
- Ensure that the device is securely positioned at its place of installation until all fastening screws have been tightened.
The fan must not be strained on fastening.
Electrical connection
DANGER: Voltage on the device’s Electric shock
- Always connect a protective earth first.
- Check the protective earth.
DANGER Faulty insulation
Risk of fatal injury from electric shock
- Use only cables that meet the specified installation regulations for voltage, current, insulation material, capacity, etc.
- Route cables so that they cannot be touched by any rotating parts.
CAUTION Voltage
The fan is a built-in component and has no disconnecting switch.
- Only connect the fan to circuits that can be switched off with an all-pole disconnection switch.
- When working on the fan, secure the system/machine in which the fan is installed to prevent it from being switched back on.
NOTE: Water ingress into wires or cables Water ingress at the customer end of the cable can damage the device.
- Make sure the end of the cable is connected in a dry environment.
INFO: Only connect the device to circuits that can be switched off with an all-pole disconnection switch.
Requirements
- Check whether the information on the nameplate matches the connection data.
- Before connecting the device, make sure the power supply matches the device’s voltage.
- Only use cables designed for the current level indicated on the nameplate.
- For determining the cross-section, note the sizing criteria according to EN 61800-5-1. The protective earth must have a cross-section equal to or greater than that of the phase conductor.
- We recommend the use of 105 °C cables. Ensure that the minimum cable cross-section is at least AWG 26 / 0.13 mm².
Protective earth contact resistance according to EN 60335
Compliance with the resistance specifications according to EN 60335 for the
protective earth connection circuit must be verified in the end application.
Depending on the installation situation, it may be necessary to connect an
additional protective earth conductor by way of the extra protective earth
terminal provided on the device.
Voltage control
NOTE: Current overshoots may occur if speed control is implemented by transformers or electronic voltage regulators (e.g. phase control). Depending on the type of installation of the device, noise and vibration may also occur in the case of phase control. Vibration can lead to bearing damage and thus premature failure.
Variable frequency drive
Please use a variable frequency drive only after consultation with ebm-papst.
INFO: For operation with variable frequency drives, install sinusoidal
filters that work on all poles (phase-phase and phase-ground) between the
drive and the motor.
During operation with variable frequency drives, an all-pole sine filter
protects the motor against high-voltage transients that can destroy the coil
insulation system, and against harmful bearing currents.
Heating-up of the motor when using a variable frequency drive must be checked by the customer following installation in the end device.
Connecting the cables
The device has external leads.
- First, connect the “PE” (protective earth).
Connect the cables according to your application. When doing so, observe the Chapter 4.4 Connection diagram.
Connection diagram
L | = blue |
---|---|
PE | = green/yellow |
N | = brown |
TOP | = thermal overload protector |
Checking connections
- Ensure isolation from supply (all phases).
- Make sure a restart is impossible
- Check the cables for proper fit.
Switching on the device
The device may only be switched on if it has been installed properly and under
its intended use, including the required safety mechanisms and professional
electrical hookup. This also applies for devices that have already been
equipped with plugs and terminals or similar connectors by the customer.
WARNING
Hot motor housing Risk of fire
Ensure that no combustible or flammable materials are located close to the
fan.
- Before switching on, check the device for visible external damage and make sure the protective devices are functional.
- Check the fan’s air flow paths for foreign matter and remove any foreign matter found.
- Apply the nominal supply voltage.
NOTE: Damage to the device from vibration Bearing damage, shorter service life
- Low-vibration operation of the fan must be ensured over the entire speed control range.
- Severe vibration can arise for instance from inexpert handling, transportation damage, and resultant imbalance or be caused by component or structural resonance.
- Speed ranges with excessively high vibration levels and possibly resonant frequencies must be determined in the course of fan commissioning.
- Either run through the resonant range as quickly as possible with speed control or find another remedy.
- Operation with excessively high vibration levels can lead to premature failure.
Switching off the device
- Disconnect the device from the power supply at the supply line switch.
- When disconnecting, be sure to disconnect the ground connection last.
MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES
Do not perform any repairs on your device. Send the device to ebm-papst for
repair or replacement.
WARNING
Live terminals and connections even with the device switched off
Electric shock
Wait five minutes after disconnecting the voltage at all poles before
opening the device.
CAUTION: The motor restarts automatically when the operating voltage is
applied, e.g. after a power failure.
Risk of injury
- Keep out of the device’s danger zone.
- When working on the device, switch off the line voltage and ensure that it cannot be switched back on.
- Wait until the device comes to a stop.
NOTE
If the device is not operated for a lengthy period in installed condition in a
dry environment, it is to be started up and operated at full speed for one
hour at least every four months. If the device is not operated for a lengthy
period in installed condition in a damp environment (e.g. outdoors), it is to
be started up and operated at full speed for at least two hours once a month
to move the bearings and allow any condensate that may have ingressed to
evaporate.
Malfunction/fault | Possible cause | Possible remedy |
---|---|---|
Impeller not running smoothly | Imbalance in rotating parts | Clean the |
device; replace it if imbalance persists after cleaning.
Make sure no weight clips are removed during
cleaning.
Motor not turning| Mechanical blockage| Switch off, isolate from supply
and remove mechanical blockage.
| Line voltage faulty| Check line voltage, restore power supply.
| Faulty connection| Isolate from supply, correct connection; see connection
diagram.
| Thermal overload protector activated| Allow motor to cool off, locate and
rectify cause of error, release restart lockout if necessary
| Impermissible point of operation| Check point of operation
Motor overtemperature| Ambient temperature too high| Reduce ambient
temperature if possible
| Deficient cooling| Improve cooling
INFO: In the event of further malfunctions, contact ebm-papst.
Cleaning
NOTE Damage to the device during cleaning Malfunction possible
- Do not clean the device using a water jet or high-pressure cleaner.
- Do not use any acid, alkali or solvent-basedcleaning agents.
- Do not use any pointed or sharp-edged objects for cleaning
Safety inspection
What to check | How to check | How often | What action? |
---|---|---|---|
Contact protection cover for intactness or damage | Visual inspection | At least | |
every 6 months | Repair or replacement of device | ||
Device for damage to blades and housing | Visual inspection | At least every 6 | |
months | Replacement of device | ||
Fastening the cables | Visual inspection | At least every 6 months | Fasten |
Fastening the protective earth terminal | Visual inspection | At least every 6 | |
months | Fasten | ||
Insulation of cables for damage | Visual inspection | At least every 6 months |
Replace cables
Welds for crack formation| Visual inspection| At least every 6 months| Replace
device
Abnormal bearing noise| acoustic| At least every 6 months| Replace device
Disposal
-
For ebm-papst, environmental protection and resource preservation are top-priority corporate goals.
ebm-papst operates an environmental management system that is certified by ISO 14001 and rigorously implemented around the world based on German standards. -
Right from the development stage, ecological design, technical safety, and health protection are fixed criteria.
-
The following section contains recommendations for the ecological disposal of the product and its components.
Country-specific legal requirements
NOTE: Country-specific legal requirements
Always observe the applicable country-specific legal regulations about the
disposal of products or waste occurring in the various phases of the life
cycle. The corresponding disposal standards are also to be heeded.
Disassembly
- Disassembly of the product must be performed or supervised by qualified personnel with the appropriate technical knowledge.
- The product is to be disassembled into suitable components for disposal employing standard procedures for motors.
WARNING
- Heavy parts of the product may drop off. Some of the product components are heavy. These components could drop off during disassembly.
- This can result in fatal or serious injury and material damage.
- `Secure components before unfastening to stop them from falling.
Component disposal
The products are mostly made of steel, copper, aluminum, and plastic. Metallic
materials are generally considered to be fully recyclable. Separate the
components for recycling into the following categories:
- Steel and iron
- Aluminum
- Non-ferrous metal, e.g. motor windings
- Plastics, particularly with brominated flame retardants, by marking
- Insulating materials
- Cables and wires
- Electronic scrap, e.g. circuit boards
Only ferrite magnets and not rare earth magnets are used in external rotor
motors from ebm-papst Mulfingen GmbH & Co. KG.
Ferrite magnets can be disposed of in the same way as normal iron and steel.
Electrical insulating materials on the product, in cables and wires, are made
of similar materials and are therefore to be treated in the same manner.
The materials concerned are as follows:
- Miscellaneous insulators used in the terminal box
- Power cables
- Cables for internal wiring
- Electrolytic capacitors
Dispose of electronic components employing the proper procedures for electronic scrap.
FAQ
Frequently Asked Questions
- Q: Who should handle the installation and operation of the device?
- A: Only suitably qualified and authorized technical staff should handle the installation, operation, and maintenance of the device.
- Q: How often should the electrical equipment of the device be checked?
- A: The electrical equipment of the device should be checked regularly as mentioned in Chapter 5.2 of the manual for safety inspection.
INFO: Please contact ebm-papst for any other questions on disposal.
CONTACT
- ebm-papst Mulfingen GmbH & Co. KG ·
- ADDRESS: Bachmühle 2 · D-74673 Mulfingen
- Phone +49 (0) 7938 81-0
- Fax +49 (0) 7938 81-110
- info1@de.ebmpapst.com
- www.ebmpapst.com
Item no. 11436-5-9970 · ENU · Change 202174 · Approved 2019-01-04 · Page 10 / 10
References
- ebm-papst – energy-saving fans and motors from the world market leader – engineering a better life
- ebm-papst – energy-saving fans and motors from the world market leader – engineering a better life
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>