Vasco 90.01.13.35 Pressure Sensor User Manual
- May 15, 2024
- Vasco
Table of Contents
Vasco 90.01.13.35 Pressure Sensor
Product Information
Specifications
- Product Name: Pressure Sensor
- Model: PL 90.01.13.35 EN 90.01.13.36
- Scope of Delivery: 1x Pressure sensor
Product Usage Instructions
-
Disconnect Power Supply
Before installing the pressure sensor, disconnect the device from the power supply by turning off the fuse for the circuit. -
Remove Inside Cover Panel
Remove the cover from the frame of the inside cover. -
Access 12V Section
Remove the left plastic cover to gain access to the 12V section of the inside cover by releasing the snap-in at the top left. -
Prepare for Installation
Remove the sticker in the frame of the inside cover to prepare for installing the pressure sensor. -
Install Pressure Sensor
Insert the pressure sensor into the socket on the circuit board ensuring the longer opening points upwards. Ensure the sensor sits vertically and flush with the plastic parts. -
Check DIP Switch Configuration
Check the configuration of the DIP switch to set the position of the device in the housing unit according to the pressure sensor usage instructions. -
Reassemble 12V Section Cover
Once the sensor is installed, reassemble the left plastic cover of the 12V section ensuring proper engagement of snap-in hooks. -
Reattach Inside Cover Panel
Install the cover onto the frame of the inside cover ensuring correct engagement of snap-in hooks. -
Restore Power Supply
Turn on the power of the device again to use it with the pressure sensor installed.
FAQ
-
Q: Can I use the product in conjunction with any components?
A: The product should only be used with components recommended by the manufacturer for proper functionality and warranty coverage. -
Q: What should I do if there is a warranty claim?
A: The manufacturer does not accept warranty claims for products that have been modified or tampered with.
Technical changes reserved. For current status see manufacturer’s homepage.
GENERAL INFORMATION
Observe and follow the warnings in the applicable instructions. Non-compliance with the warnings can lead to injuries or damage!
- Carefully read and follow the instructions before installation or use!
- Keep instructions safe for future reference!
- Installation may only be carried out by experienced and qualified professionals who are familiar with the installation of ventilation products!
- Electrical installation may only be carried out by professionals who are qualified in the field of electrotechnical systems!
- Ensure that the fastening is secure and loading capacity and statics are sufficient. Use fastening material that corresponds to the wall types.
- After receiving the product, please unpack it carefully and check for any possible damage in transit. A damaged product must not be installed or used.
- When using accessories or third-party products, follow the manufacturing instructions and ensure the suitability of products.
INTENDED USE
- The product is designed for controlled ventilation of residential buildings. It can be installed in new buildings or retrofitted to existing buildings undergoing renovation and modernisation work.
- Use of the product is permitted only in conjunction with the components recommended by the manufacturer. Modifications to the product or system are prohibited.
- Any other use is considered improper. Resulting damages are excluded from liability.
WARRANTY
The manufacturer does not accept any warranty claims in the cases of:
- Non-compliance with the instructions.
- Damage resulting from incorrect installation.
- Any form of independent modifications to the product.
EXPLANATION OF SYMBOLS
INSTALLATION INSTRUCTION
- Before installing the pressure sensor, disconnect the device from the power supply by turning off the fuse for the circuit.
- Remove the cover from the frame of the inside cover.
- Remove the left plastic cover to gain access to the 12 V section of the inside cover. Do this by releasing the snap-in at the top left.
- Remove the sticker in the frame of the inside cover in order to be able to install the pressure sensor in the following.
- Insert the pressure sensor into the socket on the circuit board so that the longer opening points upwards. Make sure that the sensor sits as vertically as possible and is flush with the plastic parts.
- Check the configuration of the DIP switch. When using the pressure sensor, the position of the device in the housing unit must be set. For more information, use the illustration on the left-hand side of the circuit board or the operating instructions of the functional unit.
- Once the sensor is installed, the left plastic cover of the 12 V section can be installed. Insert the cover and make sure that the upper snap-in hook engages.
- Install the cover onto the frame of the inside cover. Make sure that the snap-in hooks of the cover engage correctly.
- Now turn on the power of the device again to be able to use the it with the pressure sensor installed.