Haier AD125S2SH5FA High Static Ducted User Guide

May 15, 2024
Haier

Haier AD125S2SH5FA High Static Ducted

High-static ducted systems offer total heating and cooling to every room, with an indoor unit hidden in the ceiling and discreet vents. Precise temperature control, with an operational range from -20°C to 50°C Designed to fit the standard truss spacings of Australian homes for simple installation Remote control using the SmartHQ™ app when the optional Wi-Fi accessory is installed Blue Fin coating on the outdoor condenser helps prevent environmental corrosion

FEATURES & BENEFITS

Comfort in all conditions
Control the humidity level inside using the Dry function. By removing excess moisture in the air, you can create a comfortable and healthy environment that feels cooler – all while using less energy than Cool mode.

Control from anywhere
Installing the optional Wi-Fi accessory lets you control your air conditioning from your phone with the SmartHQ™ app, or use voice control with a smart home device.

Efficient DC motor
DC fan motors are renowned for using less energy than a standard AC motor. They are also highly adjustable for better airflow and static pressure tuning to suit your installation.

Simple installation
Designed to fit the standard dimensions of Australian homes, the indoor unit easily fits between roof truss spacings of 600mm. Plus, the removable panels make for easy installation and servicing.

Peace of mind
Moisture from the air is collected during normal operation. The High Static Ducted indoor unit includes a second condensate draining tray to collect liquid overflow in case of a blockage, protecting your ceiling from damage.

Central controller
With an optional central controller, you can control individual or connected units from an intuitive display. Schedule your air conditioning to turn on to create the perfect environment just before you wake up, or switch off to save energy at the end of the day.

R32 refrigerant
The Smart Power outdoor unit uses a next-generation R32 refrigerant, which carries heat efficiently and has a lower Global Warming Potential than R410A.

SPECIFICATIONS

Capacity

  • Cooling capacity (kW) 12.5kW
  • Heating capacity (kW) 14kW

Consumption

COP 3.75
EER 3.21
HSPF-RES (Hot/Average/Cold) 3.918/3.486/2.995
HSPFCOM (Hot/Average/Cold) 3.906/3.525/3.158
TCSPF-COM (Hot/Average/Cold) 4.546/4.609/4.909
TCSPF-RES (Hot/Average/Cold) 4.254/3.960/4.088

Features

Auto restart
Blue fin coils
Compressor type Inverter twin rotary
DRED (Demand Response) ready Optional
Dry mode
Electronic expansion device
MEPS approved
Motor type DC motor
Refrigerant factory charge 2.3kg
Self diagnostics
SmartHQ WiFi control HI-WB101DEI
Standard controller YR-E17A or YR-E16B

Installation

Indoor unit model AD125S2SH5FA
Indoor unit weight 59kg
Liquid line 9.52mm
Maximum pipe run 50m
Outdoor unit model 1U125S2SN5FA
Outdoor unit weight 74kg
--- ---
Suction line 15.88mm

Performance

Airflow 905/ 765 / 625 / 490L/S
DC inverter
R32 Refrigerant
Sound power SWL (outdoor) 75dBA
Sound pressure SPL (indoor) 47 / 44 / 42 / 39dBA
Sound pressure SPL (outdoor) 58dBA
Working temperature cooling -10 to 46
Working temperature heating -15 to 24

Power requirements

AMP draw 32A
Power phase 1.0
Supply frequency 50Hz
Supply voltage 220- 240V

Product dimensions

Indoor unit depth 490mm
Indoor unit height 425mm
Indoor unit width 1350mm
Outdoor unit depth 370mm
Outdoor unit height 965mm
Outdoor unit width 950mm

Warranty

Parts and labour 5 years
SKU 51673
--- ---

The product dimensions and specifications on this page apply to the specific product and model. Under our policy of continuous improvement, these dimensions and specifications may change at any time. You should therefore check with Fisher & Paykel’s Customer Care Centre to ensure this page correctly describes the model currently available.2020 Haier Inc. All rights reserved.

A PEACE OF MIND SALE
24 Hours 7 Days a Week Customer Support
T 1300 729 948 www.haier.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals