SILICON LABS SDK 7.4.1.0 GA Zigbee Protocol Stack Software
Product Information
Specifications
- Zigbee EmberZNet SDK Version: 7.4.1.0
- Gecko SDK Suite Version: 4.4 – February 14, 2024
- Vendor: Silicon Labs
- Key Features: Multiprotocol Zigbee and OpenThread support on SoC
- Compatible Compilers: GCC version 12.2.1
- EZSP Protocol Version: 0x0D
Product Usage Instructions
Compatibility and Use Notices
- For security updates and notices, refer to the Security chapter of the Gecko Platform Release notes installed with this SDK or visit the TECH DOCS tab on the Silicon Labs website.
- Stay updated by subscribing to Security Advisories.
FAQ
- Question: How do I verify the correct files are being used with the compatible compilers?
- Answer: You can verify that the correct files are being used by checking the GCC version 12.2.1 provided with Simplicity Studio.
- Question: Where can I find information about security updates and notices?
- Answer: For security updates and notices, refer to the Security chapter of the Gecko Platform Release notes or visit the TECH DOCS tab on Silicon Labs’ website.
Silicon Labs is the vendor of choice for OEMs developing Zigbee networking
into their products. The Silicon Labs Zigbee platform is the most integrated,
complete, and feature-rich Zigbee solution available.
Silicon Labs EmberZNet SDK contains Silicon Labs’ implementation of the Zigbee
stack specification.
- These release notes cover SDK version(s):
- 7.4.1.0 released February 14, 2024
- 7.4.0.0 released December 13, 2023
KEY FEATURES
Zigbee
- Zigbee R23 compliance
- Zigbee Smart Energy 1.4a compliance – production
- Zigbee GP 1.1.2 compliance – Alpha
- MG27 support – production
- Improved support for Secure Vault parts
- Sleepy support on NCP SPI (non-CPC) applications – Alpha
Multiprotocol
- Concurrent Listening support (RCP) – MG21 and MG24
- Concurrent Multiprotocol (CMP) Zigbee NCP + OpenThread RCP – production
- Dynamic Multiprotocol Bluetooth + Concurrent Multiprotocol (CMP) Zigbee and OpenThread support on SoC
Compatibility and Use Notices
For information about security updates and notices, see the Security chapter of the Gecko Platform Release notes installed with this SDK or on the TECH DOCS tab at https://www.silabs.com/developers/zigbee-emberznet. Silicon Labs also strongly recommends that you subscribe to Security Advisories for up-to- date information. For instructions, or if you are new to the Zigbee EmberZNet SDK, see Using This Release.
Compatible Compilers
- IAR Embedded Workbench for ARM (IAR-EWARM) version 9.40.1.
- Using Wine to build with the IarBuild.exe command line utility or IAR Embedded Workbench GUI on macOS or Linux could result in incorrect files being used due to collisions in Wine’s hashing algorithm for generating short file names.
- Customers on macOS or Linux are advised not to build with IAR outside of Simplicity Studio. Customers who do so should carefully verify that the correct files are being used.
GCC (The GNU Compiler Collection) version 12.2.1, provided with Simplicity
Studio.
The EZSP protocol version for this release is 0x0D.
New Items
This release of the Gecko SDK (GSDK) will be the last with combined support for all EFM and EFR devices, except for patches to this version as needed. Starting in mid-2024 we will introduce separate SDKs:
- The existing Gecko SDK will continue with support for Series 0 and 1 devices.
- A new SDK will cater specifically to Series 2 and 3 devices.
The Gecko SDK will continue to support all Series 0 and 1 devices with no
change to the long-term support, maintenance, quality, and responsiveness
provided under our software policy.
The new SDK will branch from Gecko SDK and begin to offer new features that
help developers take advantage of the advanced capabilities of our Series 2
and 3 products.
This decision aligns with customer feedback, reflecting our commitment to
elevate quality, ensure stability, and enhance performance for an exceptional
user experience across our software SDKs.
New Components
New in release
- The “zigbee_direct_security_p256” and “zigbee_direct_security_curve25519” components have been added so that users can configure a specific Zigbee Direct security option.
- Users are allowed to have multiple “zigbee_direct_security” components enabled on a Zigbee direct device (ZDD) application. In this case, the actual security option depends on the Zigbee Virtual Device (ZVD) configuration.
New APIs
New in release
- Added a new API sl_zigbee_token_factory_reset to reset Zigbee NVM3 tokens to their default value.
- Added the API bool sl_zigbee_sec_man_link_key_slot_available(EmberEUI64 eui), which returns true if the link key table can add or update an entry with this address (table is not full).
- Added a new API bool sl_zb_sec_man_compare_key_to_value (sl_zb_sec_man_context_t context, sl_zb_sec_man_key_t key), which returns true if the key is referenced by context has the same value as the key supplied in the argument.
New Platform Support
New in release
- Zigbee stack support for the following new parts is added in this release: EFR32MG24A010F768IM40 and EFR32MG24A020F768IM40.
New Documentation
New in release 7.4.0.0
- Updated the description for the Zigbee Secure Key Storage component to reflect the addition of Zigbee Secure Key Storage Upgrade (which adds backward compatibility with existing projects).
- Added a new application note for interacting with the Zigbee Security Manager group of components (AN1412: Zigbee Security Manager).
Intended Behavior
Users are reminded that Zigbee unsynchronized CSL transmissions are subject to protocol preemption at the radio scheduler. In the SleepyToSleepy applications, BLE can and will preempt a Zigbee CSL transmission, which will terminate the transmission. Scheduler preemption is more common for unsynchronized CSL, given that a potentially lengthy wake-up frame sequence may be used. Users wishing to adjust transmission priorities may use the DMP Tuning and Testing component to do so. Users may also consult UG305: Dynamic Multiprotocol User’s Guide for more information.
Improvements
Changed in release
emberCounterHandler API Doc Changes
In previous versions, the Counter Handler callback for MAC and APS layer
EmberCounterTypes concerning packet RX and TX was not being passed the proper
target node ID or data arguments, and API documentation concerning behavior of
certain counters that used these parameters was unclear or misleading.
While the signature of emberCounterHandler() has not changed, the way its
parameters are populated has changed slightly.
- Comments around EmberCounterType enums in ember-types.h have been expanded for clarity.
- The Node ID parameter to the Counter Handler for TX-related counters now checks whether the destination address mode indicates a valid short ID before using it. (If not, no destination address is populated, and a placeholder value of EMBER_UNKNOWN_NODE_ID is used instead.)
- The Node ID parameter to the Counter Handler for RX-related counters now reflects the source node ID, not the destination node ID.
- The retry count is not passed as the data parameter for EMBER_COUNTER_MAC_TXUNICAST SUCCESS/FAILED counters as described in ember-types. h in previous versions, but this was never properly populated in previously released versions so its value in previous releases would always have been 0. This behaviour has been clarified in the description of those EmberCounterTypes. However, the Retry count for APS layer retries continues to be populated in the data parameter for EMBER_COUNTER_APS_TX_UNICAST_SUCCESS/FAILED counter types, to be consistent with prior releases.
- All counters that populate the Node ID or data parameter for the callback have been audited to ensure they pass the expected data, address, or EMBER_UNKNOWN_NODE_ID if a Node ID was expected but could not be obtained from the packet, as described in the revised ember-types.h documentation.
- The Counter handler for EMBER_COUNTER_MAC_TX_UNICAST_RETRY now correctly reflects the MAC layer destination node ID and several retries in its Destination Node ID and data parameters.
- The Counter handler for EMBER_COUNTER_PHY_CCA_FAIL_COUNT now provides destination node ID information through the Node ID parameter about the intended MAC layer target of the message that failed transmission.
Updated Green Power Code
Green power server code is updated with various improvements including:
- Added more validation code for incoming commands with invalid endpoint when receiving on the GP server.
- Added code to handle the case when there is no more space to build green power messages.
- The sink now drops pairing configuration with action remove pairing in some cases per spec section A.3.5.2.4.1.
- The sink now saves the existing group list of an entry before removing it when processing Pairing Configuration with action extend.
- The Translation query command returns “NOT FOUND” as the error code when the translation table is empty or the index is bigger than several entries in the table.
- Changed the version of the GP endpoint in some apps from 1 to 0.
Using CSMA in the GPDF Send function is restricted because Green Power Devices
are minimal energy devices and do not use CSMA in most of the designs.
Instead, the preferred design is to send out multiple packets using the same
energy budget.
Removed the use of a hidden endpoint in the Green Power Server plugin option.
Use one of the application endpoints instead.
Network Key Update Plugin Code Improvements
- Changed the periodic network key update period to be as long as 1 year.
Restructured Some APIs to Avoid Unnecessary Key Export
Made changes to favour the use of key contexts over plaintext key data.
- sl_zigbee_send_security_challenge_request now takes in a sl_zb_sec_man_context_t argument in place of EmberKeyData.
- The sl_zb_sec_man_derived_key_type enum’s values are now a 16-bit bitmask to directly support certain key derivations that combine multiple derived types.
Fixed Issues
Fixed in release
ID # | Description |
---|---|
1036893 | Fixed an issue that caused the OTA cluster component to install the |
legacy boot-loader interface component as a dependency.
1114905| Zigbee Direct: Improved handling of Leave Network Characteristic.
1180937| Fixed WDT reset when connecting Zigbee Direct ZDD to 3rd party ZVD.
1223904| Fixed an issue that caused the end device to move to work incorrectly
in a very busy environment.
1224393| Updated the Green Power sink table request handler code to update the
response destination address.
1228808| Fixed the display issue with macro definitions in gp-types.h
documentation.
1232297| Fixed an issue where emberSetOutgoingNwkFrameCounter and
emberSetOutgoingApsFrameCounter did not work on 64-bit host applications
(returning EMBER_BAD_ARGUMENT).
1232359| Fixed the gppTunnelingDelay parameter calculation in green power
client command processing.
1240392
| ZDO Bind/Unbind Requests refused for access/permission reasons should return
EMBER_ZDP_NOT_AUTHORIZED status rather than EMBER_ZDP_NOT_PERMITTED status as
per Zigbee specifications.
1243523| Zigbee Direct: Improved stability of BLE connection to ZVD.
1249455| Fixed an issue that caused a sleepy end device to enter sleep when
receiving a broadcast before receiving an ack.
1252295| Fix a typo error in the component catalogue macro
SL_CATALOG_ZIGBEE_OTA_STORAGE_COMMON_PRESENT.
Fixed in release
ID # | Description |
---|---|
1019348 | Fixed the dependency requirements for the Zigbee ZCL Cli component so |
that it can be removed when not needed.
1024246| Updated the function description for emberHaveLinkKey() and
sl_zb_sec_man_have_link_key().
1036503| Added a description to recommend the use of the Micrium Kernel for
DMP sample apps.
1037661| An issue that was preventing the application from installing either
pro stack or leaf stack has been fixed.
1078136| Fixed an intermittent crash when modifying events from interrupt
context
1081548
| Users are reminded that Zigbee unsynchronized CSL transmissions are subject to protocol preemption at the radio scheduler. In the SleepyToSleepy applications, BLE can and will preempt a Zigbee CSL transmission, which will terminate the transmission. Scheduler preemption is more common for unsynchronized CSL, given that a potentially lengthy wake-up frame sequence may be used. Users wishing to adjust transmission priorities may use the DMP Tuning and Testing component to do so. Users may also consult UG305: Dynamic Multiprotocol User’s Guide for more information.
An issue has been fixed in CSL where a new wake-up frame sequence that is received immediately following a previous payload frame would not be recorded correctly. This would result in a missed payload frame.
1084111| Initial sleepy SPI-NCP support for MG24-based boards is updated as
part of this release.
1104056| Added support for network steering to run on a secondary network in
case of multi-network
1120515| Fixed an issue where the channel did not change when using the mfglib
set-channel command.
1141109| Fixed an issue that caused the generated sample application ncp-uart-
gp-multi-rail to miss some header files when using the Green Power adapter
component with the -cp option.
1144316| Updated the description of some data structure types in gp-types.h
documentation.
1144884| Fixed spurious frame pending bit set when no data is pending.
1152512| Fixed a potential crash in low-mac-rail when modifying the event in
ISR context.
ID #| Description
---|---
1154616| Added an exception for the condition to initialize the network with
the case “Switching role from Sleepy End device to Non-sleepy End device”.
1157289| Fixed an issue that may cause BDB test failure DN-TLM-TC-02B.
1157426| Fixed a build issue when building zigbee_simple_app with the
green_power_adapter component.
1157932| Added a condition to check if the “transition time” field is missing
and set a default value of 0xFFFF for this missing field.
1166340| Fixed an issue that was preventing the emberAfGpdfSend from sending
out the intended number of repeated transmissions.
1167807| Fixed an issue where devices acting as Trust Centers in distributed
networks would incorrectly clear their transient link keys each time a new
device joined.
1169504| Fixed an issue that caused a reset of a sleepy device upon forced
wake-up.
1169966| Fixed missing return value validation in buffer allocation code.
1171477,
172270
| With mfglib start 1 no messages are transmitted but received, so the
displayed terminal message “mfglib send complete” is wrong and changed to
“RXed %d packets in the last %d ms”.
1171935| Changed the periodic network key update period to be as long as 1
year.
1172778| Added the missing invocation of the
emberAfPluginGreenPowerServerUpdateAliasCallback to the Green Power server.
1174288| Fixed an issue that causes the network steering process to assert if
a call to stop an ongoing scan is called.
1178393| Updated a documentation error.
1180445| In Smart Energy, OTA now continues to download if the Coordinator
reaches the Limited Duty Cycle.
1185509| Fixed an issue in CSL where a new wake-up frame sequence that is
received immediately following a previous payload frame would not be recorded
correctly. This would result in a missed payload frame.
1186107| Fixed an issue that caused the unsuccessful decryption of received
GPDFs to replace the incoming GPDF in the gp commissioning notification.
1188397| Fixed an issue that caused a compilation error when enabling extended
report table size.
1194090| Corrected the failure status in the default response for the Sink
Commissioning Mode command – following section 3.3.4.8.2
1194963| Fixed an issue that memset the commissioningGpd structure before
calling user callback emberAfGreenPowerServerPairingStatusCallback.
1194966| Fixed an issue where the endpoint and proxiesInvolved fields were not
set with the Exit Commissioning action.
1196698| Fixed a spurious frame pending bit set when no data was pending.
1199958| Added code to handle the case when there is no more space to build
green power messages.
1202034| Fixed an issue where the sl_zb_sec_man_context_t stack variable was
not initialized correctly, causing joining with install code to fail.
1206040
| Calling emberRemoveChild() during a secure rejoin attempt by an end device can potentially lead to an extra decrement of the Child Count, potentially leading to a Child Count of -1 (255), inhibiting end devices from joining/rejoining due to an indicated lack of capacity in the Beacon.
1207580
| Child Table search functions within the stack are inconsistent in the use of
0x0000 versus 0xFFFF for node ID return value representing invalid/empty
entries, leading to problems checking for unused entries in APIs like
emberRemoveChild().
1210706| Destination and PHY Index provided in EmberExtraCounterInfo struct as
part of emberCounterHandler() may have been incorrect for MAC TX Unicast
counter types.
1211610
1212525
| Fixed an issue where Dynamic Multiprotocol applications crashed after
enabling the Secure Key Storage Upgrade component.
1211847| While the signature of emberCounterHandler() has not changed, the way
its parameters are populated has changed slightly. Changes around this API are
explained in section 2 above.
1212449
| Outgoing Beacons were incorrectly categorized by the MAC layer, leading to
emberCounterHandler() failing to catch these packets with the
EMBER_COUNTER_MAC_TX_BROADCAST counter type and instead counting the Beacons
with the EMBER_COUNTER_MAC_TX_UNICAST_SUCCESS counter type. That potentially
resulted in unreliable values for the dest EmberNodeId parameter passed to the
EmberCounterInfo struct
ID #| Description
---|---
1214866| Sending data poll packets in certain high-traffic configurations may
result in a bus fault.
1216552| An issue that causes an assertion under busy traffic conditions is
fixed.
1216613| Fixed an issue that led to an incorrect value of group cast radius in
the proxy table.
1222509| The router/coordinator sends a leave & rejoin request to a non-child
polling end device, but the MAC destination is 0xFFFF instead of matching the
NWK destination address.
1223842| Fixed an issue with the generation of the sl_component_catalog.h that
was leaving unwanted code in it causing compilation failure.
756628| Changed the invocation of application callback
emberAfMacFilterMatchMessageCallback to only be called for the ZLL messages
that are validated by the stack.
816088| Moved EMBER configuration from zigbeed_configuration.h to zigbeed.
slcp.
829508| To avoid a race condition, additional validation was added in
emberSetLogicalAndRadioChannel to return unsuccessful if the lower layers are
busy or not in a state to change the channel.
Known Issues in the Current Release
Issues in bold were added since the previous release. If you have missed a release, recent release notes are available at https://www.si- labs.com/developers/zigbee-emberznet in the Tech Docs tab.
ID # | Description | Workaround |
---|---|---|
N/A | ·The following apps/components are not supported in this release: EM4 | |
support | The feature will be enabled in subsequent releases. |
193492
| emberAfFillCommandGlobalServerToClientConfigureRe porting macro is broken.
The filling of the buffer creates an incorrect command packet.| Use the “zcl
global send-me-a-report” CLI command instead of the API.
278063| Smart Energy Tunneling plugins have conflicting treatment/usage of
address table index.| No known workaround
289569
|
The network-creator component power level picklist doesn’t offer a full range of supported values for EFR32
| Edit the range <-8..20> specified in the CMSIS comment for EMBER_AF_PLUGIN_NETWORK_CREATOR_RADIO_P
OWER in the
295498| UART reception sometimes drops bytes under heavy load in the Zigbee+BLE dynamic multiprotocol use case.| Use hardware flow control or lower the baud rate.
312291
| EMHAL: The halCommonGetIntxxMillisecondTick functions on Linux hosts currently use the getting meofday function, which is not guaranteed to be monotonic. If the system time changes, it can cause issues with stack timing.|
Modify these functions to use clock_gettime with the CLOCK_MONOTONIC source instead.
338151| Initializing NCP with a low packet buffer count value may cause
corrupt packets.| Use the 0xFF reserved value for packet buffer count to avoid
the too-low default value
387750| The issue with Route Table Request formats on the end device.| Under
Investigation
400418| A touchlink initiator cannot link to a non-factory-new end-device
target.| No known workaround.
424355
| A non-factory-new sleepy end device touchline target-capable initiator is not able to receive a device information response in certain circumstances.|
Under Investigation
465180
| The Coexistence Radio Blocker Optimization item “Enable Runtime Control” may block proper Zigbee operation.| Optional ‘Wi-Fi Select’ Control of Blocker Optimization should be left “Disabled”.
480550
| The OTA cluster has its built-in fragmentation method, hence it should not use APS fragmentation. Although, in case APS encryption is enabled it grows the payload of the ImageBlockResponses to a size where the APS fragmentation is activated. This could lead to the OTA process failing.|
No known workaround
481128
| Detailed Reset Cause and crash details should be available by default via the Virtual UART (Serial 0) on NCP platforms when the Diagnostics plugin and Virtual UART peripheral are enabled.| Since Serial 0 is already initialized in the NCP, customers can enable the emberAfNcpInitCallback in the Zigbee NCP Framework and call the appropriate diagnostic functions (halGetExtendedResetInfo, halGetExtendedResetString, halPrintCrashSummary, halPrintCrashDetails, and halPrintCrashData) in this callback to print this data to Serial 0 for viewing in the Network Analyzer capture log.
For an example of how to use these functions, refer to the code included in a -main-soc.c’s emberAfMainInit() when EXTENDED_RESET_INFO is defined.
ID # | Description | Workaround |
---|
486369
| If a DynamicMultiProtocolLightSoc forming a new network has child nodes remaining from a network it has left, emberAfGetChildTableSize returns a non- zero value in startIdentifyOnAllChildNodes, causing Tx 66 error messages when addressing the “ghost” children.| Mass-erase the part if possible before creating a new network or programmatically check the child table after leaving the network and delete all children using emberRemoveChild before forming a new network.
495563
| Joining SPI NCP Sleepy End Device Sample App doesn’t short poll, therefore the joining attempt fails at the state of Update TC Link Key.| The device that wishes to join should be in Short Poll mode before attempting to join. This mode can be forced by the End Device Support plugin.
497832
| In Network Analyzer the Zigbee Application Support Command Breakdown for the Verify Key Request Frame mistakenly references the part of the payload that indicates the frame Source Address as the Destination Address.|
No known workaround
519905
521782
| Spi-NCP may very rarely fail to start up bootloader communication using the ‘bootload’ CLI command of the ota-client plugin.|
Restart the bootload process
620596
| NCP SPI Example for BRD4181A (EFR32xGMG21)
nWake default pin defined cannot be used as a wake-up pin.
|
Change the default pin for nWake from PD03 to a EM2/3 wake-up-enabled pin in the NCP-SPI Plugin.
631713
| A Zigbee End Device will report address conflicts repeatedly if the plugin “Zigbee PRO Stack Library” is used instead of “Zigbee PRO Leaf Library”.| Use the”Zigbee PRO Leaf Library” instead of the “Zigbee PRO Stack Library” plugin.
670702
| Inefficiencies within the Reporting plugin can lead to significant latency based on data write frequency and table size, which may interfere with customer application code, including event timing.| If doing frequent writes, consider checking reporting conditions and sending reports manually rather than using the plugin.
708258
| Uninitialized value in groups-server.c via addEntryToGroupTable() can create a spurious binding and cause group cast reporting messages to be sent.| Add “binding.clusterId = EMBER_AF_INVALID_CLUSTER_ID;” after “binding.type
= EMBER_MULTICAST_BINDING;”
757775
|
All EFR32 parts have a unique RSSI offset. In addition, board design, antennas and enclosure can impact RSSI.
| When creating a new project, install the RAIL Utility, RSSI component. This feature includes the default RSSI Offset Silabs measured for each part. This offset can be modified if necessary after RF testing of your complete product.
758965
| ZCL cluster components and the ZCL command discovery table are not
synchronized. Therefore, when enabling or disabling a ZCL cluster component,
implemented commands will not be enabled/disabled in the corresponding ZCL
Advanced Configurator command tab.| Manually enable/disable discovery for the
desired ZCL commands in the ZCL Advanced Configurator.
765735| The OTA update fails on Sleepy End Device with enabled Page Request.|
Use Block Request instead of Page Request.
845649
|
Removing CLI: The core component does not eliminate EEPROM cli calls to sl_cli.h.
| Delete the eeprom-cli.c file that calls the sl_cli.h. Additionally, calls to sl_cli.h as well as sl_cli_command_arg_t in the ota-storage-simple-eeprom can be commented out.
857200
| ias-zone-server. c allows for a binding to be created with a
“0000000000000000” CIE address and posteriorly does not allow further
bindings.| No known workaround
1019961| Generated Z3Gateway makefile hardcodes “gcc” as CC| No known
workaround
ID #| Description| Workaround
---|---|---
1039767
|
Zigbee router network retry queue overflow issue in multi-thread RTOS use case.
| Zigbee Stack is not thread-safe. As a result, calling Zigbee stack APIs from another task is not supported in the OS environment and may put the stack into a “non-working” state. Refer to the following App note for more information and a workaround using the event handler.
https://www.silabs.com/documents/public/application- notes/an1322-dynamic-multiprotocol-bluetooth-zigbee- sdk- 7x.pdf .
1064370| The Z3Switch sample application only enabled one button (instance:
btn1) by default which leads to a mismatch in the but- ton description in the
project file.| Workaround: Install the btn0 instance manually during Z3Switch
project creation.
1161063| Z3Light and potentially other applications report incorrect cluster
revision values.| Manually update the cluster revision attribute to their
appropriate revision.
1164768,
1171478,
1171479
| ERROR: ezspErrorHandler 0x34 reported repeatedly during mfglib receive mode| To reduce the error messages printed, configure EMBER_AF_PLUGIN_GATEWAY_MAX_WAIT_FOR_EV
ENT_TIMEOUT_MS on the host app to 100, so the callback queue is freed more quickly.
1252460| SimEEPROM recovery routines (for both v1 and v2) run at startup may perform misaligned flash page erase calls resulting in assertions during em_msc. c’s MSC_ErasePage routine.| *Workaround: Place the following line of code at the top of the MSC_ErasePage() function in em_msc.c: start address = (uint32_t)((uint32_t)startAddress &**
~(FLASH_PAGE_SIZE- 1));
Deprecated Items
Deprecated in release
In GSDK 7.4.0.0 onwards, including this patch, the “-v” option in a Z3Gateway
for a linux host application to create a telnet interface with port 4900 or
4901 is deprecated. The alternative recommended way to create a telnet
interface is to use linux utilities such as “socat”.
Deprecated in release
Removed the following deprecated security APIs:
- emberGetKey()
- emberGetKeyTableEntry()
- emberSetKeyTableEntry()
- emberHaveLinkKey()
- emberAddOrUpdateKeyTableEntry()
- emberAddTransientLinkKey()
- emberGetTransientKeyTableEntry()
- emberGetTransientLinkKey()
- emberHmacAesHash()
Use the APIs provided by Zigbee Security Manager for access to key storage and HMAC hashing.
Removed Items
Removed in release
- Removed duplicate public APIs in public header file gp-types.h.
- The zigbee_end_device_bind component has been removed. This component was used for the coordinator to broker binding re-quests for end devices. This optional functionality was removed from R22 of the Zigbee core spec.
- Removed setPacketBufferCount() in af-host.c and useless check case EZSP_CONFIG_PACKET_BUFFER_COUNT: in command-handlers.c.
- Removed memoryAllocation argument because there is no need to divide into two phases when initializing NCP.
- Removed emberAfNcpInitCallback() in se14-comms-hub, se14-ihd, and se14-meter-gas ‘s app.c.
- Removed setting EZSP_CONFIG_RETRY_QUEUE_SIZE value during ncp initialization in ncp-configuration.c
Multiprotocol Gateway and RCP
New Items
Added in release
- Concurrent listening, the ability for the Zigbee and OpenThread stacks to operate on independent 802.15.4 channels when using an EFR32xG24 or xG21 RCP, is released.
- Concurrent listening is not available for the 802.15.4 RCP/Bluetooth RCP combination, the Zigbee NCP/OpenThread RCP combination, or for the Zigbee/OpenThread system-on-chip (SoC). It will be added to those products in a future release.
- The OpenThread CLI vendor extension has been added to the OpenThread host apps of multiprotocol containers. This includes the coex cli commands.
Improvements
Changed in release
- The Zigbee NCP/OpenThread RCP multiprotocol combination is now production quality.
Fixed Issues
Fixed in release
ID # | Description |
---|
1213701
| zigbeed didn’t allow a source match table entry to be created for a child if
MAC indirect queue has data already pending for that child. This behavior
could lead to application layer transactions between the child and some other
device failing due to lack of APS Ack or app-layer response, most notably the
disruption and unexpected termination of ZCL OTA Upgrades targeting the child
device.
1244461| Source match table entry for child being could be removed despite
messages pending.
Fixed in release
ID # | Description |
---|---|
1081828 | Throughput issue with FreeRTOS-based Zigbee/BLE DMP sample |
applications.
1090921| Z3GatewayCpc had trouble forming a network in a noisy environment.
1153055| An assert on the host was caused when there was a communication
failure when reading the NCP version from the zigbee_ncp-ble_ncp-uart sample
app.
1155676| The 802.15.4 RCP discarded all received unicast packets (after MAC
acking) if multiple 15.4 interfaces shared the same 16-bit node ID.
1173178| The host falsely reported hundreds of packets received with mfglib in
the Host-RCP setup.
1190859| EZSP error when sending mfglib random packets in the Host-RCP setup.
1199706| Data polls from forgotten end device children were not properly
setting a pending frame on the RCP to queue a Leave & Rejoin command to the
former child.
1207967| The “mfglib send random” command was sending out extra packets on
Zigbeed.
1208012| The mfglib rx mode did not update packet info correctly when
receiving on the RCP.
1214359| The coordinator node crashed when 80 or more routers tried to join
simultaneously in the Host-RCP setup.
1216470
| After relaying a broadcast for address mask 0xFFFF, a Zigbee RCP acting as a parent device would leave the pending data flag set for each child. This resulted in each child staying awake expecting data after each poll, and required some other pending data transaction to each end device to eventually clear this state.
Known Issues in the Current Release
Issues in bold were added since the previous release. If you have missed a release, recent release notes are available on https://www.si- labs.com/developers/gecko-software-development-kit.
ID # | Description | Workaround |
---|---|---|
811732 | Custom token support is not available when using Zigbeed. | Support is |
planned in a future release.
937562| Bluetoothctl ‘advertise on’ command fails with rcp-uart- 802154-blehci
app on Raspberry Pi OS 11.| Use btmgmt app instead of bluetoothctl.
1022972| Coex not working on ZB NCP + OT RCP.| Support is planned for a future
release.
1074205| The CMP RCP does not support two networks on the same PAN id.| Use
different PAN ids for each network. Support is planned in a future release.
1122723| In a busy environment the CLI may become unresponsive in the z3
-light_ot-ftd_soc app.| No known workaround.
1124140| z3-light_ot-ftd_soc sample app is not able to form the Zigbee
network if the OT network is up already.| Start the Zigbee network first
and the OT network after.
1170052
| CMP Zigbee NCP + OT RCP and DMP Zigbee NCP + BLE NCP may not fit on 64KB and lower RAM parts in this current release.|
64KB parts not currently supported for these apps.
1209958
| The ZB/OT/BLE RCP on Bobcat and Bobcat Lite can stop working after a few minutes when running all three protocols|
Will be addressed in a future release
1221299| Mfglib RSSI readings differ between RCP and NCP.| Will be addressed
in a future release.
1231021| OTBR can assert when 80+ zigbee devices are joining
simultaneously.| Added a fix that may workaround the issue. Will be fully
addressed in a future release.
Deprecated Items
- None
Removed Items
Removed in release
- The “NONCOMPLIANT_ACK_TIMING_WORKAROUND” macro has been removed. All RCP apps now by default support 192 μsec turnaround time for non-enhanced acks while still using 256 μsec turnaround time for enhanced acks required by CSL.
Using This Release
This release contains the following:
- Zigbee stack
- Zigbee Application Framework
- Zigbee Sample Applications
For more information about Zigbee and the EmberZNet SDK see UG103.02: Zigbee
Fundamentals.
If you are a first-time user, see QSG180: Zigbee EmberZNet Quick-Start Guide
for SDK 7.0 and Higher, for instructions on configuring your development
environment, building and flashing a sample application, and documentation
references pointing to next steps.
Installation and Use
The Zigbee EmberZNet SDK is provided as part of the Gecko SDK (GSDK), the
suite of Silicon Labs SDKs. To quickly get started with the GSDK, install
Simplicity Studio 5, which will set up your development environment and walk
you through GSDK installation. Simplicity Studio 5 includes everything needed
for IoT product development with Silicon Labs devices, including a resource
and project launcher, software configuration tools, full IDE with GNU
toolchain, and analysis tools. Installation instructions are provided in the
online Simplicity Studio 5 User’s Guide.
Alternatively, Gecko SDK may be installed manually by downloading or cloning
the latest from GitHub. See https://github.com/Sili-conLabs/gecko_sdk for
more information.
Simplicity Studio installs the GSDK by default in:
- (Windows): C:\Users\
\SimplicityStudio\SDKs\gecko_sdk - (MacOS): /Users/
/SimplicityStudio/SDKs/gecko_sdk
Documentation specific to the SDK version is installed with the SDK. Additional information can often be found in the knowledge base articles (KBAs). API references and other information about this and earlier releases is available on https://docs.silabs.com/.
Security Information
Secure Vault Integration
For applications that choose to store keys securely using the Secure Key
Storage component on Secure Vault-High parts, the following table shows the
protected keys and their storage protection characteristics that the Zigbee
Security Manager component manages.
Wrapped Key | Exportable / Non-Exportable | Notes |
---|---|---|
Network Key | Exportable | |
Trust Center Link Key | Exportable | |
Transient Link Key | Exportable | Indexed key table, stored as volatile key |
Application Link Key | Exportable | Indexed key table |
Secure EZSP Key | Exportable | |
ZLL Encryption Key | Exportable | |
ZLL Preconfigured Key | Exportable | |
GPD Proxy Key | Exportable | Indexed key table |
GPD Sink Key | Exportable | Indexed key table |
Internal/Placeholder Key | Exportable | Internal key for use by Zigbee Security |
Manager
- Wrapped keys that are marked as “Non-Exportable” can be used but cannot be viewed or shared at runtime.
- Wrapped keys that are marked as “Exportable” can be used or shared at runtime but remain encrypted while stored in flash.
- User applications never need to interact with the majority of these keys. Existing APIs to manage Link Key Table keys or Transient Keys are still available to the user application and now route through the Zigbee Security Manager component.
- Some of these keys may become non-exportable to the user application in the future. User applications are encouraged to not rely on the exporting of keys unless absolutely necessary.
- For more information on Secure Vault Key Management functionality, see AN1271: Secure Key Storage.
Security Advisories
To subscribe to Security Advisories, log in to the Silicon Labs customer
portal, then select Account Home. Click HOME to go to the portal home page and
then click the Manage Notifications tile. Make sure that ‘Software/Security
Advisory Notices & Product Change Notices (PCNs)’ is checked, and that you are
subscribed at minimum for your platform and protocol. Click Save to save any
changes.
Support
Development Kit customers are eligible for training and technical support. Use
the Silicon Laboratories Zigbee web page to obtain infor-mation about all
Silicon Labs Zigbee products and services, and to sign up for product support.
You can contact Silicon Laboratories support at
http://www.silabs.com/support.
Simplicity Studio
One-click access to MCU and wireless tools, documentation, software, source
code libraries & more. Available for Windows, Mac and Linux!
Disclaimer
Silicon Labs intends to provide customers with the latest, accurate, and in-
depth documentation of all peripherals and modules available for system and
software implementers using or intending to use the Silicon Labs products.
Characterization data, available modules and peripherals, memory sizes and
memory addresses refer to each specific device, and “Typical” parameters
provided can and do vary in different applications. Application examples
described herein are for illustrative purposes only. Silicon Labs reserves the
right to make changes without further notice to the product information,
specifications, and descriptions herein, and does not give warranties as to
the accuracy or completeness of the included information. Without prior
notification, Silicon Labs may update product firmware during the
manufacturing process for security or reliability reasons. Such changes will
not alter the specifications or the performance of the product. Silicon Labs
shall have no liability for the consequences of use of the information
supplied in this document. This document does not imply or expressly grant any
license to design or fabricate any integrated circuits. The products are not
designed or authorized to be used within any FDA Class III devices,
applications for which FDA premarket approval is required or Life Support
Systems without the specific written consent of Silicon Labs. A “Life Support
System” is any product or system intended to support or sustain life and/or
health, which, if it fails, can be reasonably expected to result in
significant personal injury or death. Silicon Labs products are not designed
or authorized for military applications. Silicon Labs products shall under no
circumstances be used in weapons of mass destruction including (but not
limited to) nuclear, biological or chemical weapons, or missiles capable of
delivering such weapons. Silicon Labs disclaims all express and implied
warranties and shall not be responsible or liable for any injuries or damages
related to use of a Silicon Labs product in such unauthorized applications.
Note: This content may contain offensive terminology that is now obsolete. Silicon Labs is replacing these terms with inclusive language wherever possible. For more information, visit www.silabs.com/about-us /inclusive-lexicon-project.
Trademark Information
Silicon Laboratories Inc.®, Silicon Laboratories®, Silicon Labs®, SiLabs® and
the Silicon Labs logo®, Bluegiga®, Bluegiga Logo®, EFM®, EFM32®, EFR, Ember®,
Energy Micro, Energy Micro logo and combinations thereof, “the world’s most
energy friendly microcontrollers”, Redpine Signals®, WiSeConnect , n-Link,
ThreadArch®, EZLink®, EZRadio®, EZRadioPRO®, Gecko®, Gecko OS, Gecko OS
Studio, Precision32®, Simplicity Studio®, Telegesis, the Telegesis Logo®,
USBXpress® , Zentri, the Zentri logo and Zentri DMS, Z-Wave®, and others are
trademarks or registered trademarks of Silicon Labs. ARM, CORTEX, Cortex-M3
and THUMB are trademarks or registered trademarks of ARM Holdings. Keil is a
registered trademark of ARM Limited. Wi-Fi is a registered trademark of the
Wi-Fi Alliance. All other products or brand names mentioned herein are
trademarks of their respective holders.
CONTACT
- Silicon Laboratories Inc.
- 400 West Cesar Chavez
- Austin, TX 78701
- USA
- www.silabs.com
References
- Silicon Labs
- Silicon Labs
- About Us - Silicon Labs
- Silicon Labs Community
- Internet of Things (IoT) - Silicon Labs
- Simplicity Studio - Silicon Labs
- Technical Support - Silicon Labs
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>