Specifications
- Model: ACCSL2021
- Manual Version: v1.51
- Optional Second Temperature Sensor: cat#: ACCSLBLET
Wireless Temperature Sensor(s) Setup
-
Install 2 AAA batteries by turning the clip cap counterclockwise 1/8 rotation to open.
-
Insert batteries with the negative end first.
-
To close, align printed arrows on clip cap and sensor, push in, and twist 1/8 turn clockwise.
-
To power on, press the power button until the blue LED flashes 5 times. LED should flash once every 10 seconds. To power off,
press the power button until LED flashes twice, then release. -
Note the four-digit serial number on the backside of the sensor(s) and assign to intended P1/P2 in settings page.
-
Place the wireless sensor in the storage unit to be monitored. Allow the sensor temperature to stabilize before setting up DDL (wait approx. 60 minutes).
SmartLOG Digital Data Logger (DDL) Setup
- Insert 3 AA batteries in the compartment behind DDL for backup only. Use a wall 110VAC adapter as the primary power source.
- Attach the wall 110VAC adapter to DDL using the USB cable and plug it into a wall outlet.
- Push and hold the ON button on the back of SmartLOG DDL until a beep sounds, then release.
- The screen will show “Scanning For Networks” and then change to “Select Network” when the scan is completed.
- Tap on “Select Network” using the provided plastic stylus.
- A drop-down list of SSID’s (Wi-Fi network names) will appear in order from nearest to farthest location.
- Tap on your desired network name and enter the Wi-Fi network password when prompted.
- Tap the return key on the keyboard to connect to the network. If successful, follow instructions on the dashboard to complete settings.
FAQ
-
Q: How do I reset the SmartLOG DDL?
A: To perform a factory reset, press the Factory Reset Button which will delete all settings on the device. -
Q: How do I acknowledge an alarm on the SmartLOG Dashboard?
A: Tap on the Speaker icon to acknowledge the alarm. This action will mute the alarm buzzer and send an ACK alert. -
Q: What is the purpose of the Battery Compartment on SmartLOG DDL?
A: The Battery Compartment is for backup purposes only and should be used with AA batteries. The primary power source should be a wall 110VAC adapter.
MANUAL
ACCSL2021
FEATURES
- Monitor 1 or 2 Wireless Temperature Sensors Simultaneously
- Ambient Room Temperature and Humidity Displayed & Recorded
- SMS and Email Alerts
- Replaceable Wireless Sensors!
- No down time for sending equipment back for calibration.
- No fumbling with wires in fridge.
- Bright Color Touch Display for ease of use.
- Web Dashboard, use any browser on local network
- No cloud, No subscription fees!
- Enterprise Network Login for Security
- Time automatically synchronized from internert
- Reports in .PDF format
- No PC Software needed
- Second Temperature Sensor optional (cat#: ACCSLBLET)
SmartLOG DDL
- Red Alarm LED
- USB Power LED Green
- 5v Mirco USB Port
- Factory Reset Button Deletes All Settings
- Power On Button
- Wall Mount Keyhole
- Kick Out Desk Stand
- Battery Compartment
MAIN SCREEN
-
Logger Name
-
Ambient Room Temperature Humidity
-
Time And Date Of Last Scan
-
Buzzer, Wi-Fi Strength, Battery Level Icons
P1 Tile -
P1 Wireless Sensor Name
-
Battery Remaining Power
-
Bluetooth Signal Strength
-
Lowest Temperature Since Last Reset
-
Highest Temperature Since Last Reset
-
Alarm Set Points Min/Max
-
Current Temperature
Same as P1
OPTIONS SCREEN
- Dashboard IP Address
- Close Options Screen
- Option Buttons
- Last Message Today
KIT CONSIST OF
- 1 x Digital Data Logger
- 1 x Wireless Transmitter
- 1 x 5V 1A Power Adapter
- 1 x USB Cable
- 2 x AAA (for transmitter)
- 3 x AA (for DDL)
- 1 x Plastic Touch Screen Stylus
PRODUCT OVERVIEW
The AccuTherm refrigerator/freezer thermometer data logger (also referred to
as SmartLOG in this document) is a Wi-Fi digital data logger (DDL) that
monitors and records temperature and sensor battery status for up to two
wireless sensors. It also logs the ambient room temperature/humidity and
backup battery voltage.
The DDL scans for the wireless sensor in 1 minute intervals retrieving
temperature, battery and signal data. This data is evaluated for temperature
excursions, low battery condition or no data which indicates signal loss from
the wireless sensor. If any of these conditions are true, the logger will send
alerts via email and text message to contacts listed in the settings page of
the dashboard. If there is a temperature excursion, alarm LED and buzzer will
sound. Logger then refreshes the main DDL display screen and dashboard with
all updated values. The SmartLOG dashboard can be viewed using a web browser
on a PC or smart phone. Monitor all DDL conditions, generate PDF reports, and
modify settings. using Dashboard (SmartLOG and PC or smart phone must be
connected to same local network).
NOTE: If main power is lost, battery backup is provided by the 3 x AA
batteries allow logging to continue for ~ 3 days (depending on alerts) After
approximately 4 hours the DDL will turn off the display and Wi-Fi radio to
conserve power allowing logging to continue until main power resumes. Tapping
display will power screen for ~1 minute for viewing and then go back off. The
Web Dashboard will not be accessible until main power resumes. Alerts will
continue to be sent while on battery backup.
The wireless temperature sensor(s) LED blinks every 10 seconds, indicating
sensor sent temperature, battery power, and signal strength.
PRODUCT SETUP:
Wireless Temperature Sensor(s)
- Install quantity 2 AAA batteries. To open turn clip cap counterclockwise 1/8 rotation.
- Place batteries negative end in first.
- To close align printed arrows on clip cap and sensor to each other, push in and twist 1/8 turn clockwise.
- To power on wireless sensor, press power button until blue LED flashes 5 times. LED should flash once every 10 seconds. To power off sensor, press power button until LED flashes two times, then release button.
- Take note of the four digit serial number on the backside of the sensor(s) and assign to intended P1/P2 in settings page. e.g., P1 Name: Fridge SN# 000E
- Place wireless sensor in storage unit to be monitored. Allow the sensor temperature to stabilize before setting up
DDL. (wait approx. 60 minutes)
SmartLOG Digital Data Logger (DDL)
NOTE: The following instructions are only necessary on the initial Start-up of SmartLOG. All configuration settings will be retained in DDL memory.
-
Install quantity 3 AA batteries in compartment behind DDL. Slide cover down to open. Batteries are for backup ONLY! Use wall 110VAC adapter as primary source of power.
-
Attach wall 110VAC adapter to DDL using USB cable and plug in AC adapter to wall outlet.
-
Push and hold ON button on back of SmartLOG DDL until beep sounds, then release.
-
Screen will show “Scanning For Networks” fig. 1
-
Then will change to “Select Network” when scan has completed. fig. 2
-
Tap using provided plastic stylus on “Select Network”
-
A drop-down “SSID’s” (Wi-Fi network names) will appear in location nearest to farthest order. fig. 3
-
Tap on your desired network name you want to connect to.
-
A password field and keyboard will appear, enter the wi-fi network password. fig. 4. Tap eye icon to see hidden typed text if needed.
-
Tap the return key on keyboard (lower right corner) to enter values. DDL will now connect to network.
-
If SmartLOG is able to make a connection to the network, a message will be displayed instructing to complete remaining setup using a web browser. fig. 5 Follow “Dashboard” section to complete settings. If SmartLOG is not able to connect to network it will return to line #4. Repeat network setup.
DASHBOARD
-
In the address bar of a web browser fig. 6, enter “SmartLOG/” or the IP address displayed on DDL. fig. 5
Note: Host Name “SmartLOG” can be changed in settings page if desired. -
On SmartLOG Dashboard page, click on the “Settings” (cog icon). A pop-up will appear, leave PIN field empty and click “Open”.
-
The Settings Page will now open, customize SmartLOG for desired operation then click Save to complete NOTE: The Access PIN field will require a 5 digit number in order to save the form. This PIN will be required for future access to settings page.
-
When settings are saved the SmartLOG will automatically start booting. If an Update pop-up is displayed, ignore unless there are new features you require or are having issues with SmartLOG. SmartLOG will continue booting after 5 seconds.
-
Display will show boot messages Check Memory, Get Network Time, Set Time Zone, Send Alert Message ‘Booted’ and Then Scan for Temp(s). Once temps are received the Main Screen will be displayed. fig. 7
SMARTLOG DASHBOARD
HOME PAGE
Navigation Icons
Logger Name, Alarm Spk, Wi-Fi, Pwr icons Tap Speaker icon to acknowledge
alarm. This will mute Alarm Buzzer and send ACK alert Sensor(s) Name
Temperature Gauge relative to Min/Max set points Current temperature Min/Max
settings values Lowest and Highest recorded Temperature, Date and Time Sensor
Battery power remaining Signal strength
STATUS PAGE
Logger Information: Sensor serial number Consecutive lost signals from
wireless sensor, Logging interval Wi-Fi IP addr, Mac addr, Signal strength CPU
temperature, Ram used and free Firmware version running
Support: Links to online manual, QuickStart video, instructional video.
REPORT PAGE
- Month: selection starts on 1st and reports to last record of month.
- Custom: from/to dates for report (31 days max). NOTE: Reports should be created weekly !
- Create: button generates the report.
- Report generation can take up to 1 min to create. If no response refresh web page (F5) and create report again.
- CSV Download: button creates a .csv file of data from report that can be opened in Excel. Custom .csv if State Data is checked in seutp
- Print/Save: button opens print menu, select save as PDF option to create a permanent file on your PC.
Report has 4 sections
- Sensor Info
- Daily Summary
- Excursion Logs
- Status/Alert Logs
- Logs
All excursion values are color coded red for high values, blue for low values
SETTINGS PAGE ACCESS POP-UP
Pin: 5 digit number
If created during initial setup enter Pin number, otherwise, leave blank and
click Open.
SETTINGS PAGE
Logger Configuration
- Access Pin: 5 digit number (required to save) Scale: Display & Report in °C or °F.
- Log Interval: Select from 1 to 60 minutes.
- Time Zone: Set your local Time Zone.
- DST: Daylight Savings Time, sets clock forward by one hour when checked.
- Time is automatically synchronized from internet. Logger Name: Name is used in reposts, emails & SMS messages sent. Do not use the same name if using additional data loggers on the same network. Use up to 12 alphanumeric characters, hyphen “-”, no spaces.
- Facility Name: Location:, Pin or ID#: are optional fields that show on reports.
Sensor Settings
P1 & P2 Name: A drop down list to select Fridge or Freeze that will auto-
populate Alarm Temp: min and max values. Custom name & min/max values can be
entered. For single sensor application, set
P2 to No Sensor
Sensor SN#: Enter 4 digit serial number located on back of wireless sensor or
new replacement sensor.
In-Service: Auto-populates with current date. Reports will display Sensor
Expires date (+2 yrs from the In-Service date).
Wi-Fi Setting
These fields are populated from the initial SmartLOG SETUP.
If you need to change the network:
Network Name: SSID (Service Set Identifier) is the name of your wireless
network
Password: network password.
Username: is for Enterprise Networks.
Email/SMS Contact
Email: Address to send alert email to.
SMS: 10 digit phone number to send text msg to.
State Data
Custom state .csv files can be downloaded after report creation for sending to
states that have specific requirements.
Daily Status Messages
Select one or both an am or pm time for daily notifications of sensor(s)
current, min, max temps and battery level plus ambient room temperature,
humidity and SmartLOG battery state. These messages will be displayed in
Reports Status/Alert Logs section. Time: can be set to OFF for both am and pm
to disable status messages.
TEMPERATURE EXCURSIONS
If a temperature sensor detects an excursion the SmartLOG alarm led will
flash, buzzer will sound and DDL display and dashboard tiles will change to
warning colors. SeeACK BUTTON for more information
DDL OPTIONS SCREEN
Tapping “Main” screen anywhere opens the “Options” screen. fig. 8 Tap X to
close options screen if no change are needed.
EMAIL / SMS MESSAGES
Alert Messages sent every hour until acknowledged ACK| Time
Date Temperature Excursion Name : Temp 8.5C (above limit of 8.0C) Time
Date Temperature Notice Name : Returned to safe temp 7.5C”
---|---
- Time Date POWER Failure ON Battery Backup 100% remaining Time Date POWER Restored OFF Battery Backup
- Time Date Sensor Signal Lost Name : Check sensor battery or distance from logger Time Date Sensor Signal Found Name : Check sensor battery or distance from logger
- Time Date Sensor Battery Low Name : Replace battery 24% remaining
**Alert Messages From Buttons| Time Date User Stopped Logging Time Date User Started Logging
---|---
Time Date Alarm Acknowledged
Time Date Test Message Dev-Logger IP address is: xxx.xxx.xxx.xxx
Time Date User Reset Min Max
Daily Status Messages**| p1 Name : Cur:7.6C Min:5.0C Max:7.6C Bat:100%p2 Name : Cur:-20.0C Min:-20.0C Max:-20.0C Bat:100% Amb:22.8C/48.5% Bat:CHRG
---|---
LOGGING BUTTON : When set to OFF, data recording will stop and alerts will be disabled from being sent NOTE: Alerts are sent every hour until alarm condition clears, or if logging is off.
LOGGING OFF
- If button reads “LOGGING ON” it is in the ON state, logging data active.
- Tap this button to turn LOGGING OFF. Wait for button to transition as email/SMS alerts are being sent out. When alerts are complete, the screen will switch back to the main screen automatically showing DDL tile in red and logger name replaced with “LOGGING OFF”.
LOGGING ON
- f button reads “LOGGING OFF” it is in the OFF state, logging data stopped.
- Tap this button to turn LOGGING ON. Wait for button to transition as Email/SMS alerts are being sent out. When alerts are sent the screen will switch back to the main screen automatically showing DDL tile blue and “LOGGING OFF” replaced with logger name.
ACK BUTTON: When temperature excursions are acknowledged with the ACK button the audible buzzer will be muted and an alert message will be sent. The screen will switch back to the main screen automatically after Email/SMS are sent. Speaker icon will have an X indicating speaker is muted. You can acknowledge an alarm with text message also.
If ACK BUTTON was clicked and temperature returns to a safe range, DDL display and dashboard will return to normal.
T EST MESSAGE BUTTON: Will send an email and/or SMS to recipients in contact list. Received message links will open Dashboard in a browser.
- Tap TEST MESSAGE button.
- Tap YES in Confirm pop-up window will send a Test Email and SMS message then return to main screen. If you tap NO, the pop-up will close and you will be sent back to main screen automatically.
RESET MIN/MAX BUTTON: Sets memory recorded min and max values to current temperature, time and date and re-moves alert and alarm colors from display if excursion was triggered.
- Tap RESET MIN/MAX button.
- Tap YES in confirm pop-up window to reset values. Wait for button to transition as email/SMS alerts are being sent out. Pop-up will close and switch back to the main screen automatically. If you tap NO, the pop-up will close and will be sent back to main screen automatically.
UPDATE CHECK BUTTON: Checks online for new firmware. If new firmware is available, user has option to update. NOTE: Only recommended if having issues or new features you require.
- Tap UPDATE CHECK.
- Taping YES in confirm pop-up window will download and install firmware then return to main screen. If you tap NO, the pop-up will close and will be sent back to main screen automatically. Other responses: No Wi-Fi: SmartLOG not connected to network, No Updates: SmartLOG is up to date.
TURN OFF BUTTON: Powers off SmartLOG.
- Tap TURN OFF button.
Tap YES in confirm pop-up window to power off. Wait for button to transition as email/SMS alerts are being sent out. Confirm pop-up window “Powering Off In 5 Seconds”.
TROUBLESHOOTING GUIDE
Logger not powering on| Check 5v adapter, USB cable, batteries
Not receiving wireless temperatures| Check batteries and/or shorten distance
between DDL and sensor
Data logger not responding| Remove USB power and batteries: reinstall
batteries and connect USB power cord. Push on button until you hear beep. If
no response data logger may be faulty.
Incorrect Time| Turn logger off. Start logger, will update from online time
server.
Not able to connect to browser| Name or IP must be entered in the ADDRESS BAR
not SEARCH SmartLOG DDL must be connected to same network as PC or smart phone
Unresponsive web page| Click the refresh icon or press the F5 key for PC
Reset to factory| Press RESET button on back of unit until you hear 2 beeps.
Unit will reboot. Will need to re-configure logger.
Email Response: Timed Out| Was not able to connect to your email server,
incorrect credentials, email and/ or password.
SPECIFICATIONS
SMARTLOG® DDL MONITOR GATEWAY
Wi-Fi:| 802.11 b/g/n (2.4 GHz only)
Security:| WPA/WPA2 Enterprise
Display:| 240×320 pixel TFT Color Display w/Touch Screen
Screen Update:| 60 seconds
Memor:| 16MB (2 years of records @ 5 minute intervals)
Ambient Sensor:| Temperature range -40 to +125°C (-40°F to 257°F), Humidity
range 0-100%RH
Alarms:| Audible Piezo Buzzer/Visual LED/SMS/Email
Date/Time:| NTP clock synchronization during boot
Power:| 5v wall adapter w/5’ micro USB cable
Batteries:| Alkaline 1.5v 3 x AA (backup only for power loss)
Battery Life:| ~ 3 days with no alarms, (NOTE: replace all batteries after any
power loss of more than 1 day)
Working Temp:| -20 °C ~ 70 °C
Dimensions:| 83 (W) X 120 (H) X 26 (D) mm,
WIRELESS BUFFERED TEMPERATURE SENSOR
Temperature Range:| -40C to 50°C (-40°F to 122°F)
Accuracy:| ±0.5°C (±1.0°F)
Distance:| 50m/164ft (open field), 10m/32ft (inside fridge/freezer)
Buffer medium:| Glycol
Batteries:| Alkaline 1.5v 2 x AAA
Battery Life:| ~1yr
Certification:| 2yr NIST ISO17025 Certificate Included
Warranty:
With respect to the goods, unless expressly agreed otherwise in writing, Thermco Products, Inc. provides warranty for material and manufacturing defects for a period of one (1) year from date of purchase. During said period, Thermco Products, Inc. offers to provide physical examination of goods, provide repair of goods and/or components, or replace defective goods. This process would be subject to Thermco Products, Inc. issuing a Return Goods Authorization (RGA), which may or may not be at customer expense. Warranty shall not be considered for components such as batteries, incompetent installation, faulty maintenance by customer, normal wear and tear or deterioration of components due to improper use or non-compliance with proper use of goods.
Note
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
- Contains FCC ID: 2AC7Z-ESP32WROVERE
- Contains IC: 2109-ESP32WROVERE
- CAN ICES-003(A)/NMB-003(A)
- DTS (Digital Transmission Systems) rules replace DSS (Direct Sequence Spread spectrum)
10 Millpond Drive Unit #10 Lafayette, NJ 07848 – Phone: 973.300.9100
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>