CMTOOL B09TPFY4MX Digital Manometer User Manual

May 15, 2024
CMTOOL

CMTOOL B09TPFY4MX Digital Manometer

Product Information

  • Specifications
    • Measuring range: 0~50 (32~122)
    • Measurement unit: mmHg, inHg, ftH2O, cmH2O, inH2O, Pa, kPa, mbar, bar, kg/cm2, psi, oz/in2
    • Accuracy: Err0
    • Repeatability: Err1
    • Linearity/hysteresis: 1
    • Measurement rate: 4
    • Data storage: Yes
    • Maximum pressure: Not specified
    • Indoor temperature measurement: Yes
    • Automatic shut-down: Yes (automatically shut down after 15 minutes of no operation)
    • Exceed the positive pressure range display: Err0
    • Exceed the negative pressure range display: Err1
    • Working temperature: 0~50°C (32~122°F)
    • Storage temperature: -10~60°C (14~140°F)
    • Power supply: 9V
    • Appearance dimensions: 164X70X32mm
    • Weight: 200g

Product Usage Instructions

  • Product Usage Areas
    • This product can be extensively used in various applications including natural gas pipelines, air conditioning and refrigeration ventilation systems, mechanical hydraulics, plastic moulding, ceramic products manufacturing, biopharmaceutical moulding, mining pressure testing, petrochemical industrial smelting, gas and liquid production industrial equipment pressure detection, liquid level detection, laboratory calibration, medical environment micro-pressure testing, etc.
  • Structure Description
    • The product consists of various components including a power on/off button, storage temperature switch, hold data value button, measurement unit switch, differential value mode button, pressure data and units display interface, positive and negative pressure input channels, and battery compartment cover.
  • Operation Instruction of Buttons
    • POWER button:
    • Short press to turn it on.
    • Short press to turn on/off the backlight in the power-on state.
    • Press and hold to shut down (automatically shuts down after 15 minutes of no operation).
  • button:
    • Short press to store the current measured pressure value (up to 100 groups).
    • Long press to exit the storage mode.
    • Long press for more than 2 seconds to switch the temperature unit.
  • Features and Specifications
    • Resolution: Various resolutions ranging from 0.00001 to 1 depending on the measurement unit

FAQs

  • Q: What should I do if the instrument shows inaccurate data?
    • A: The instrument should be kept away from vibration sources, strong electromagnetic fields, and areas with drastic temperature changes to avoid inaccurate data caused by vibration and electromagnetic interference, temperature fluctuations, etc.

Product introduction

  • This instrument is designed with imported pressure sensors, high precision ADC and low power consumption MCU.
  • It features a professional digital pressure gauge with high precision, wide range, high resolution, large screen display and indoor temperature measurement; with a single channel, it is possible to quickly measure the current detection pressure value (relative to the current atmospheric pressure), whereas the dual channel allows simultaneous detection of the pressure difference between the two detection ports (P1-P2).

Product Usage

This product can be extensively used in natural gas pipelines, air conditioning and refrigeration ventilation systems, mechanical hydraulics, plastic moulding, ceramic products manufacturing, biopharmaceutical moulding, mining pressure testing, petrochemical Industrial smelting, gas, liquid and production industrial equipment pressure detection, liquid level detection, Laboratory calibration, medical environment micro-pressure testing, etc.

Technical Parameters

Measuring range ±100Kpa
Measurement unit mmHg,inHg,ftH2O,cmH2,O,inH2O

Pa,kPa,mbar,bar,kg/cm2,psi,oz/in2
Accuracy| ±0.3%FSO (25℃)
Repeatability| ±0.2% (Max ±0.5%FSO)
Linearity/hysteresis| ±0.29%FSO (25℃)
Measurement rate| 0.5s
Data storage| 100groups
Maximum pressure| 100kPa
Indoor temperature measurement| Optional ℃ / ℉ unit
Automatic shut-down| After about 15 minutes without any operation
Exceed the positive pressure range display| Err0
Exceed the negative pressure range display| Err1
Working temperature| 0~50℃ (32~122℉)
---|---
Storage temperature| -10~60℃ (14~140℉)
Power supply| 9V
Appearance dimensions| 164X70X32mm
Weight| 200g

Details Description

  1. Temperature data \ storage serial number
  2. Low battery reminder
  3. Keep the data mode
  4. Maximum \ Minimum Mode
  5. Differential pressure mode
  6. Pressure data
  7. Pressure unit

Structure Description

1 Power on \ backlight on \ off Shut down
2 Storage temperature Celsius \ Fahrenheit switch
3 Hold data value button Clear drift data
4 Measurement unit switching Clear all stored data
5 Checking records upwards when viewing stored data DIF ( differential value

) mode
6| Checking records downwards when viewing stored data| Max / Min Data Mode
7| Pressure data and units display interface
8| Positive pressure input channel P1
9| Negative pressure input channel P2
10| Battery compartment cover

Operation instruction of Buttons

  1. POWER button
    • a. Short press to turn on.
    • b. Short press to turn on/off the backlight in the power-on state.
    • c. Press and hold to shut down (automatically shut down after 15 minutes of no operation).
  2. ℃/℉button
    • a. Short press to store the current measured pressure value ( up to 100 groups).
    • b. Long press to exit the storage mode.
    • c. Long press for more than 2 seconds to switch the temperature unit.
  3. HOLD button
    • a. Short press to lock and hold the current data value.
    • b. Long press for more than 2 seconds to clear the drift data (Please press and hold this button if the data is not reset before measurement).
  4. UNITS button
    • a. Short press to switch between up to 12 pressure units.
    • b. Long press for more than 2 seconds to clear the stored data.
  5. DIF button
    • a. Short press to go up to view stored data.
    • b. Long press for more than 2 seconds to enter the P1 and P2 dual-channel differential pressure mode.
    • c. In DIF mode, press and hold for more than 2 seconds to exit the differential pressure mode.
  6. MAX button
    • a. Short press to go up to view stored data.
    • b. Long press for more than 2 seconds to enter the maximum and minimum mode
    • c. Long press for another 2 seconds to return to the normal measurement mode.

Features and specifications

Unit Range Resolution
Kpa ± 100 0.01
mmHg ± 750.061 0.001
InHg ± 29.5299 0.0001
ftH2O ± 33.4552 0.0001
cmH2O ± 1019.72 0.01
InH2O ± 401.463 0.001
Pa ± 100000 1
mbar ± 1000 0.01
bar ± 1 0.00001
Kg/cm² ± 1.01971 0.00001
psi ± 14.5037 0.0001
Oz/in² ± 232.060 0.001

Precautions

  • The instrument should be kept away from vibration sources, strong electromagnetic fields and areas with drastic temperature changes to avoid inaccurate data caused by vibration and electromagnetic interference, temperature fluctuations, etc.
  • When measuring corrosive and toxic gases or liquids, please pay attention to protective measures to avoid personal danger or damage to the instrument.
  • When the instrument remains low battery, please replace the battery in time. Please take out the battery when you don’t use the instrument for a long time, so as not to damage the instrument by liquid leakage.
  • Please do not exceed the maximum value of input ±100kPa, when measuring the pressure of a single channel, please do not block the other channel, nor should it face the windy direction. At this moment, the instrument displays the differential value between the current measurement port and atmospheric pressure.
  • When the interface displays over the range during measurement, please disconnect the vent, and then the displayed data will automatically back to normal; (The Pa unit can only be displayed up to 9999, and it can be switched to the next KPa unit).
  • Please press and hold the HOLD button to clear the zero point drift of the data under the current mode before measurement (before connecting to the air tube).

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals