Schneider Electric MEG5754-03 Display Timer Module Standard User Guide

May 15, 2024
Schneider Electric

Schneider Electric MEG5754-03 Display Timer Module Standard

Specifications:

  • Product Name: Display Timer Module Standard
  • Art. no.: MEG5754-03../-04..

Product Information

The Display Timer Module Standard is a versatile device that allows for local light and blind control as well as global light and blind control via PlusLink (PL). It can be combined with various inserts to perform switching, dimming, or blind control functions.

Connections, Displays, and Operating Elements:

The module features front display elements such as Display, Menu button, Manual push-button, OK button, and UP arrow button. The rear of the module includes a Module interface for connectivity

Mounting Instructions:

To mount the module, insert it into the corresponding frame along with the necessary inserts for desired functionality. Follow the initialisation process after plugging the module onto the insert for the first time.

Basic Functions:

The basic functions of the module include blind control, light control, setting time and date, and switching between summer and winter time. These functions can be accessed through the menu and manual push-buttons.

Operating Instructions:

To operate the module, use the menu button to navigate through different settings and options. Make use of the UP arrow button to adjust settings and the OK button to confirm selections.

FAQ

What should I do if there is a problem?

If you encounter any issues with the module, such as error messages or functionality errors, try resetting the module to default settings by pressing the push-buttons simultaneously for 10 seconds. Refer to the user manual for troubleshooting steps or contact customer support for assistance.

Necessary accessories

  • Complete the display timer module standard with:
  • Corresponding inserts (see function overview)
  • Frame in design System M

For your safety

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
Safe electrical installation must be carried out only by skilled professionals. Skilled professionals must prove profound knowledge in the following areas:

  • Connecting to installation networks
  • Connecting several electrical devices
  • Laying electric cables
  • Safety standards, local wiring rules and regulations
    Failure to follow these instructions will result in death or serious injury.

Getting to know the display timer module standard

In combination with different inserts, you can carry out various functions with the display timer module standard (referred to below as module), such as:

  • switching, dimming and controlling blinds manually
  • time-controlled switching and controlling of blinds

Product features

  • simple operation using five push-buttons

  • adjustable date and time

  • Number of switching cycles (switching on/off, raising/ lowering):
    Switching, dimming, blind inserts: per channel: 2 switching cycles/day
    Central unit insert: per PL line: 2 switching cycles/day

  • Weekdays summarised in two fixed groups (Monday- Friday, Saturday+Sunday)

  • Switching times preset at the factory, but can be changed later for each weekday group

  • Switching to manual mode possible

  • Global control (max. 4 PL lines) and separate line control

  • Saving scenes is possible

  • Two global scenes can be retrieved via push-buttons

  • Automatic summer/winter time switchover

  • Individually adjustable blind movement time

  • Adjustable display brightness

  • Automatic deactivation of display lighting can be selected

  • Power reserve of at least 6 hours in the event of a power failure

  • Reset (restore default settings)

Overview of module functions on receiving inserts
Complete the module with the receiving inserts for switching, dimming or controlling blind/roller shutter in order to carry out local light and blind control.

Function overview of the module on sending insert
Complete the module with the sending central unit insert in order to carry out global light and blind control via the PlusLink (PL).

Global light and blind control

Connections, displays and operating elements

  • A Display

  • B Menu button

  • C Manual push-button

  • D OK button

  • E UP arrow button
    Push-button function (factory setting): Raising/ switching on
    Scene function*: Scene 1

  • F DOWN arrow button
    Push-button function (factory setting): Lowering/ switching off
    Scene function*: Scene 2

  • G LEDs

*Can only be selected as alternative in combination with a central unit insert.

Rear:

  • A Module interface

Display elements

The displayed symbols depend on the inserts used and the sensors connected via PlusLink.

Individual display elements
You will see the following symbols on the display:

Standard display
Example of the standard display during operation:

Mounting the module

  • A Insert (see function overview)
  • B Frame
  • C Display timer module standard

Initialising the module
After plugging the module onto the insert for the first time, information on the module type and module version are displayed for one second each. Standard display with flashing clock symbol follows this.

Module type display: Display timer module standard

Standard display with flashing clock symbol

Set time and date (see Section “Setting module: Basic menu settings”).

Error message after changing over the module

If the module is plugged onto an insert that differs in functionality from the previous one, the error message “FAIL” appears and all LEDs flash red.
For initialisation, reset the module to the default settings.

When you do a reset to the default settings, previously saved settings are lost! The set time and date are not reset.

  1. Press the push-buttons simultaneously for 10 seconds.
    The standard display appears after resetting.

Getting to know the basic functions

Blind/roller shutter” will be referred to below as just “blind”.

Switching times
The module has a program memory that contains standard switching times that can be changed anytime.

The switching times perform specific actions:

  • Switching time : Raise blind, switch on light

  • Switching time : Lower blind, switch off light Both switching times together result in a switching cycle.
    You can set switching times for two weekday groups:

  • working days: Monday-Friday

  • weekends: Saturday+Sunday
    The switching times apply to all the days in a group.

Module in combination with switchable/dimmable inserts
Two switching cycles per day are available for each channel.

Module in combination with a blind control insert

Module in combination with a central unit insert
Two switching cycles per day are available for each PL line.

The standard switching times and weekday groups per channel or PL line are:

Getting to know the menu

The module has two menu levels:

  1. Menu level:
    Set time and date
    Set switching times

  2. Menu level: Advanced menu
    Selecting arrow button function
    Save scenes
    Activating/deactivating automatic summer/winter time switchover
    Set individual blind movement time
    Set display brightness
    Set automatic deactivation of display lighting

The following push-buttons are used to operate the menu:

With a long press of [Menu], the menu for setting the time and switching time appears after 2 s. To open the advanced menu, hold the [Menu] push-button down.
If you do not press any push-button in the menu for more than 2 minutes, the standard display appears. Changes that are not confirmed with [OK] are not saved.

Setting module: Basic menu settings

Set time and date

Menu structure

Setting

  1. Open menu: Press [Menu] push-button for 2 s.
    The time display flashes.

Set switching times

Menu structure

In combination with a 2-gang insert you can set the switching times separately for each channel. The menu briefly displays the corresponding channel (CH 1/ CH 2) when it is started and every time the weekday group is changed.
In combination with a central unit insert you can set the switching times separately for each PL line. The menu briefly displays the corresponding PL line (PL 1-4) when it is started and every time the weekday group is changed.

Setting

  1. Open menu: Press [Menu] push-button for 2 s. The display “Setting the time” appears. To set the switch-ing time, briefly press the [Menu] push-button.
    The working days are briefly displayed.
    The switching time of the first switching cycle for the working days is then displayed.
    The time display flashes.

  2. Set switching time push-button.

  3. Confirm setting with [OK].
    You can delete the switching time with the [Man] push button. If you press the push button again,the previously set switching time is displayed.The time display flashes.

  4. Set switching time with or push-button.

  5. Confirm setting with [OK].
    The time display flashes.

  6. Set second switching time with or push-button.

  7. Confirm setting with [OK].
    If you press the [Man] push-button a switching time set previously appears.
    The time display flashes.

  8. Set second switching time with or push-button.

  9. Confirm setting with [OK].
    The weekend days will be briefly displayed.
    The time display flashes.
    Repeat the individual steps for setting the switching time (see working days).

Setting module: Advanced menu

The possible settings in the advanced menu depend on the respective insert (see overview of functions).

Structure of the advanced menu

  • A Standard display only in combination with a central unit insert

  • B Selecting arrow button function

  • C Display of PL line / ALL (scenes for four PL lines can be set separately / then global scenes for all PL lines can be set together) only in combination with switchable/dimma-ble inserts

  • D Channel display (scenes can be set separately for two channels)

  • E Scene 1

  • F Save scene 1

  • G Scene 2

  • H Save scene 2

  • I Activating/deactivating automatic summer/winter time switchover
    only in combination with a blind control insert

  • J Setting individual blind movement time

  • K Set display brightness

  • L Set automatic deactivation of display lighting

Selecting arrow button function
(Only in combination with a central unit insert)

If the push-button function has been preset at the factory, you can use the arrow buttons to move the blinds up and down or turn the light on and off. Alternatively, you can use a central unit insert to retrieve scenes via the arrow buttons. You can individually save one scene per arrow button (see “Save scenes”). In order to do this switch the configuration of the arrow buttons from push-button function to the scene function.

  1. Open advanced menu: Press [Menu] push-button for 4 s.
    The display for the arrow button function appears.

  2. Select function with push-button .

  3. Confirm setting with [OK].
    Configuration of the arrow buttons with scene function applies in automatic mode and in manual mode.

Save scenes
The module allows you to save two scenes that are acti-vated by switching times.
In addition to this, you can save two global scenes
(PL 1-4) that can be retrieved with the arrow buttons. These global scenes are only possible in combination with a central unit insert and the respective scene func-tion selected for the arrow buttons. (See “Selecting ar-row button function”)

Display of the corresponding channel (CH 1/ CH 2), of the corresponding PL line (PL 1-4) and all PL lines (ALL)

  • In combination with a 2-gang insert you can set two scenes separately for each channel. The menu briefly displays the corresponding chan-nel (CH 1/ CH 2) when it is started and every time the weekday group is changed.
  • In combination with a central unit insert you can set two scenes separately for each PL line. The menu briefly displays the corresponding
  • PL line (PL 1-4) when it is started and every time the weekday group is changed.
  • In combination with a central unit insert and the scene function for the arrow buttons you can set two global scenes for all PL lines. The menu briefly displays “ALL”.
  1. Set brightness of lamps, and desired position of blind (any values possible) with push-button . Saving blind scenes:
    Raise blind to the uppermost position and wait for 2 minutes (running time) until the status display disappears from the display. Then set the desired position of the blind.

  2. Open advanced menu: Press [Menu] push-button for 4 s.
    Scene 1 display appears.

  3. Confirm setting with [OK]. The “no” display appears.

  4. Select save option (“yes”) with push-button .

  5. Confirm setting with [OK].

    • Light scene: All lamps are switched off briefly and then back on again to indicate that the saving procedure has been successful. Then the lamps adopt the saved brightness value.
    • Blind scene: The blinds are lowered and raised by one step to indicate that the saving procedure was suc-cessful.

Scene 2 display appears.

Repeat the individual steps of scene 1.

Activating/deactivating automatic summer/winter time switchover

  1. Open advanced menu: Press [Menu] push-button for 4 s.

  2. Press [Menu] push-button repeatedly until the fol- lowing display appears.
    “On” flashes.

  3. Use the push-button to select between “On” (switchover activated) and “Off” (switchover deactivated).

  4. Confirm setting with [OK].

Additional settings for blind control

If the module is combined with a blind control insert, further functions are available (for more information see “Notes on advanced functions”)

Setting individual blind movement time

  1. Open advanced menu: Press [Menu] push-button for 4 s.

  2. Press [Menu] push-button repeatedly until the following display appears.
    The time display for the individual blind movement time flashes.

  3. Set the movement time (30 seconds to 3 minutes) with push-button .

  4. Confirm setting with [OK].

Display settings

Setting display brightness

  1. Open advanced menu: Press [Menu] push-button for 4 s.

  2. Press [Menu] push-button repeatedly until the following display appears.
    The display brightness display flashes.

  3. Set the display brightness on a scale from 00 (off) to 04 (bright) with the or push-button.

  4. Confirm setting with [OK].

Set automatic deactivation of display lighting

(The setting option is not shown if the display brightness is set to “0”.)

  1. Open advanced menu: Press [Menu] push-button for 4 s.

  2. Press [Menu] push-button repeatedly until the following display appears.
    The current setting appears (here default setting: Display lighting is on permanently):

  3. Change setting with push-button .
    LOn: Display lighting is on permanently.
    Lt: Display lighting switches off automatically 10 seconds after the last input.

  4. Confirm setting with [OK].

Notes on advanced functions

Additional functions for blind control Individual blind movement time
The module is preset at the factory so that the blind takes 2 min. to be lowered (and, where necessary, stops auto-matically when the lower limit position is reached). You can adjust this time freely between 30 seconds and 3 minutes. This means scenes can be performed faster.(see “Setting individual blind movement time”). Disabling blind movement with magnetic contact (Only in combination with blind control insert, brightness sensor interface flush- mounted and magnetic contact) Raising/lowering the blind via PlusLink commands or via switching times of the display timer module is disabled by a magnetic contact when the window or door is open.
Manual operation is still possible with the and push-buttons.

CAUTION
Risk of burglary!

Please bear in mind that the blind will not close while the window/door is open when using the magnetic contact.

Response to mains voltage failure and recovery / power reserve
In the event of mains voltage failure the display goes out. The following menu settings are saved permanently:

  • Switching times
  • Arrow button function
  • Scenes
  • Display settings
  • Operating mode

The set time and date are saved for at least 6 hours thanks to the power reserve (no batteries required).
After mains voltage recovery the next switching time is carried out. Missed switching times are not carried out.

Operating the module

Deactivate the time and PlusLink control
Press the [Man] push-button to switch the module to manual mode and deactivate the control via set switch-ing times and via PlusLink commands. Loads can then only be controlled manually with the push-buttons.

Exceptions:

  • The panic scene is being executed.
  • In combination with a blind control insert, the module reacts to sensor values via PlusLink and controls the blind accordingly. To switch back, press the [Man] push-button for 2 s.
    After switching to manual mode, “Auto” disappears from the display and the LED next to the [Man] push-button lights up red.

Basic functions

Status LEDs for the module

Resetting to default settings

Blind control

Controlling blinds

  • raising/lowering (> 0.5 s)
  • up/down in steps (< 0.5 s)

Global blind control

Global control via PlusLink is possible in combi-nation with the central unit insert and the display timer module standard.

Example of global raising/lowering and gradual up/down of 1-4 PL lines
Following activation of the push-buttons and of the module on the central unit insert, all loads in the PL lines are controlled together.

Arrow buttons with push-button function

  • Long push-button action (> 0.5 s): raising/lowering
  • Short push-button action (< 0.5 s): up/down gradually
  • A Module on central unit insert
  • B Blind control insert

Light control

Switching load on/off
In combination with 1-gang / 2-gang insert

In combination with a 2-gang insert both channels are switched together.
Display of the status arrow in the display only refers to channel 1.

Dimming load
In combination with 1-gang / 2-gang insert

In combination with a 2-gang insert both channels are dimmed together.
Display of the status arrow only refers to channel 1.

Global light control

Global control via PlusLink is possible in combi-nation with the central unit insert and the display timer module standard.

Example of globally switching on/off and dimming the 1-4 PL lines
Following activation of the push-buttons and of the module on the central unit insert, all loads in the PL lines are controlled together:

Arrow buttons with push-button function

  • Short push-button action (< 0.5 s): turn on/off
  • Long push-button action (> 0.5 s): dimming
  • A Module on central unit insert
  • B Inserts for switching and dimming (see function overview)

Global blind and light scenes

Global scenes are possible via the arrow buttons in combination with the central unit insert and the display timer module standard.

Arrow buttons with scene function:
Short push-button action (< 0.5 s): retrieve scene 1/2

  • Central unit insert or side controller Plus, 1- gang/2-gang: switching, dimming, controlling blinds and retrieving scenes
  • Mechanical push-button/double push-button
  • Sensor interface + sensors

What should I do if there is a problem?

“FAIL” flashes on the display, all LEDs flash red.

  • Module was plugged onto an insert that differs in func-tionality from the previous one.
    Reset module to default settings.

The blind or lighting does not react to a set switching time.

  • PlusLink commands deactivate the switching times.
    The panic scene is being executed.
    Window / door with magnetic contact is open.
    All other PlusLink commands and switching times are performed when levels 1 – 4 are not carried out.

  • The module is in manual mode.