Unit and ComPonent

Foshan Shunde Xiangtai Scavenging Material Industrial
ZG-XT-KJ Air Purifier fig \(1\)

Product Structure

Foshan Shunde Xiangtai Scavenging Material Industrial
ZG-XT-KJ Air Purifier fig \(2\)

Using Guide

The product you purchased has been installed with the packaged filter. Please take down the plastic bag of the filter according to the following steps before use, and install and use it correctly.Foshan Shunde Xiangtai
Scavenging Material Industrial ZG-XT-KJ Air Purifier fig
\(7\) Foshan
Shunde Xiangtai Scavenging Material Industrial ZG-XT-KJ Air Purifier fig
\(4\)

  1. Unpack the package and take out the medicine.
  2. Flip the machine, twist the bottom cover to unlock direction, and take out the packaged filter.
  3. Take down the plastic bag of filters.
  4. The filter is fixed on the bottom cover.
  5. Close the bottom cover and twist in the lock direction.
  6. Plug in the power adapter line to the machine.
  7. Plug the power adapter into the socket.
  8. Press the on/off key to run the machine

Operation Guide

Regular functionFoshan Shunde Xiangtai Scavenging Material Industrial ZG-
XT-KJ Air Purifier fig \(5\)

Turn on/off
After the product is connected to the power supply, touch the button Q) , the product enters the working state,it defaults to automatic mode operation. The gear of the product fan is adju­sted according to the PM2.5 real-time monitoring data, the PM2.5 data is displayed as follows:

PM.25 Index Air Quality Fan Gear
10-79 Excellent 1
80-299 Good 2
300-500 Pollution 3![Foshan Shunde Xiangtai Scavenging Material Industrial

ZG-XT-KJ Air Purifier fig 8](https://manuals.plus/wp-content/uploads/2022/09 /Foshan-Shunde-Xiangtai-Scavenging-Material-Industrial-ZG-XT-KJ-Air-Purifier- fig-8.png)

10 seconds after turn on the machine ,the display” – – -“after 10 seconds ,shows the real-time PM2.5 data

  • Wind speed adjustment
    Touch the wind speed + button, disable automatic mode, and enter manual mode.

  • Negative ion purification (WIFI function is only applicable to KJA07-A3) Touch the negation ion button Ef: turn on/off the negative ion function.
    In the working state, long press the negative ion button for 3 seconds, enter the wifi status, and connect the APP.

  • Mode-SLEEP
    Touch the sleep button and the machine enters the sleep mode, the screen display, and PM2.5 status indicator will be turned off, and the fan will work at ultra-low speed, if you need to wake up the screen, tapping any button can wake up the screen.

Timer
Touch the Timer button, the timer starts from 1-12hours, and the power will be turned off when the time expires.

Child lock
Touch the Child lock button a, and the machine will be locked. In the state of the child lock, the other buttons can’t be used . Long press the button child lock for 3 seconds,the child lock function will be unlocked . In a non-child lock state, long press the child lock button, and the screen display switches to the usage time(hours)of the filter.

Special function

Sterilization (for KJA07-A2, KJA07-A3)
Touch the sterilization button, and turn on/off this function.

 Cleaning and Maintenance

Cautions:

  • Always turn off the adapter plug before cleaning.
  • Never immerse products and accessories in water or any other liquid.
  • Never use abrasive, corrosive, or flammable detergents(such as bleach or alcohol)to clean any part of the product.
  • The air purification filter should not be washed or vacuumed .Foshan Shunde Xiangtai Scavenging Material Industrial ZG-XT-KJ Air Purifier fig 8Foshan Shunde Xiangtai Scavenging Material Industrial ZG-XT-KJ Air Purifier fig \(6\)

Filter Replacement:

  1. After the product is powered off,u nscrew the filter cover according to the direction of the base filter cover switch, take out the air purification filter whose service life has ended, and put it into the corresponding garbage can.
  2. Remove all packaging materials from the new filter and put the removed filter back into the product.
  3. Screw the filter cover in the direction indicated by the base screen cover switch to place the product on a stable table.
  4. Insert the adapter into the socket. After the product is powered on, tap the power button to make the product work normally. About XT-KJA07-Al and XT-KJA07-A2 touch the timer button for 5 seconds. (About XT-KJA07-A3 touch the timer button 0 for 5 seconds. )The full remaining life timer is reset. Note: The used air filter contains contaminants collected from the air. Do not touch the filter cotton directly or smell the filter.