Inxpect SpA S203A Smart Sensor 200 Series 60GHz Radar User Manual

May 15, 2024
Inxpect SpA

Inxpect SpA S203A Smart Sensor 200 Series 60GHz Radar

Specifications

  • Product Name: Inxpect Safety Radar Equipment 200 Series
  • Model: SRE 200 Series
  • Compliance: FCC Part 15, Innovation, Science and Economic Development Canada’s licence-exempt RSS(s)
  • Usage: Safety radar equipment
  • Country Restrictions: U.S. – FCC, Canada – ISED

Product Usage Instructions

FCC Compliance (U.S.)
The Inxpect Safety Radar Equipment 200 Series complies with part 15 of the FCC Rules for most devices, except for specific models like S201A-MLR. Users must ensure the device does not cause harmful interference and is capable of accepting interference.

Installation Guidelines
When installing the sensor, maintain a minimum distance of 20 cm between the device and individuals to comply with FCC RF exposure requirements.

Prohibited Devices in the USA
The use of S201A-MLR (SBV-01-MLR) is forbidden in the USA.

Local Representation in the USA
For the C20xB control unit, users can contact Inxpect North America at 10375 N. Baldev Court, Suite B, Milwaukee, Wisconsin 53092, United States or email hello@inxpect.us.

ISED Compliance (Canada)
The Inxpect Safety Radar Equipment 200 Series complies with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s) for most devices, with exceptions like S201A-MLR and S203A-WL.

FAQ

Q: Can I use the Inxpect Safety Radar Equipment 200 Series in a residential area?
A: Operation in a residential area may cause harmful interference to radio communications. Ensure proper installation and compliance with guidelines to prevent interference.

Q: What should I do if I encounter interference issues?
A: If interference occurs, the user is responsible for correcting it at their own expense. Contact the manufacturer for assistance if needed.

National configurations addendum

For the use of Inxpect Safety Radar Equipment 200 Series
Copyright © 2024 Inxpect S.p.A. – All Rights Reserved

Revision Author Date Notes
v01 B.Treachi 19/11/2021 Initial version
v02 B.Treachi 26/11/2021 Small changes
v03 B.Treachi 3/12/2021 Details for FCC and ISED
v04 B.Treachi 6/12/2021 Changed FCC section
v05 B.Treachi 17/12/2021 Added certification for an additional country
v06 B.Treachi 25/01/2021 Removed certification for an additional country
v07 B.Treachi 28/02/2022 Added MLR specs and added new name scheme
v08 B.Treachi 29/03/2022 Changed file name. Added ANATEL code
v09 B.Treachi 13/04/2022 Small changes
v10 B.Treachi 18/11/2022 Added South Africa (ICASA), Europe, Hong Kong,

Australia/New Zealand
V11| B.Treachi| 10/02/2023| Added new products
v12| E.Varrenti/D.Dei| 05/06/2023| Small modifications
v13| E.Varrenti/D.Dei| 06/06/2023| Added power limitations for USA/Canada
v14| D.Dei/E.Varrenti| 23/06/2023| Added EIRP for Europe and UK
v15| E.Varrenti/D.Dei| 14/07/2023| Added Mexico and US local representative for control unit typeB
v16| B.Treachi| 21/08/2023| Removed limitation for Australia / New Zealand
v17| B.Treachi| 15/12/2023| Modified Japan, Australia, New Zealand, Korea and Mexico
v18| B.Treachi| 25/01/2024| Modified FCC
v01| D.Dei| 22/11/2021
---|---|---
v02| D.Dei| 2/12/2021

Conformity

U.S. – FCC
For SBV-01/S201A, FCC ID: 2ANOS-SBV01 or FCC ID: 2ANOS-S201A
For S203A, FCC ID: 2ANOS-S203 or FCC ID: 2ANOS-S203A

Accordingly to part 15 of the FCC Rules:

  • FCC ID: 2ANOS-SBV01 – Maximum EIRP = 0dBm;

  • FCC ID: 2ANOS-S201A – Maximum EIRP = +20dBm;

  • FCC ID: 2ANOS-S203 – Maximum EIRP = +1dBm;

  • FCC ID: 2ANOS-S203A – Maximum EIRP = +20dBm.
    Each device of the Inxpect SRE 200 Series complies with part 15 of the FCC Rules, with the exception of the following devices:

  • S201A-MLR (SBV-01-MLR)
    Operation is subject to the following two conditions:

  • this device may not cause harmful interference, and

  • this device must accept any interference received, including interference that may cause undesired operation

NOTICE: changes or modifications not expressly approved by Inxpect SpA could void the user’s authority to operate the equipment.

Note: each device of the SRE 200 Series has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules, with the exception of the following devices:

  • S201A-MLR (SBV-01-MLR) These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. To ensure compliance with FCC RF exposure requirements the sensor must be installed to provide a minimum of 20 cm between the device and people. The use of the following devices is forbidden in the USA:

  • S201A-MLR (SBV-01-MLR)
    For C20xB control unit: the local representative is Inxpect North America: www.inxpect.us
    Inxpect North America Corp. 10375 N. Baldev Court, Suite B -Milwaukee, Wisconsin 53092 – United States – hello@inxpect.us

Canada – ISED
For SBV-01/S201A, IC: 27966-SBV01
For S203A, IC: 27966-S203
Accordingly Innovation, Science and Economic Development Canada’s licence- exempt RSS(s):

  • SBV-01/S201A Maximum EIRP = 0dBm;
  • S203A Maximum EIRP = +1dBm.

Each device of the Inxpect SRE 200 Series contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s) , with the exception of the following devices:

  • S201A-MLR (SBV-01-MLR)
  • S201A-WL
  • S203A-WL

Operation is subject to the following two conditions:

  • This device may not cause interference.
  • This device must accept any interference, including interference that may cause undesired operation of the device. To ensure compliance with ISED RF exposure requirements the sensor must be installed to provide a minimum of 20cm between the device and people.

The use of the following devices is forbidden in Canada:

  • S201A-MLR (SBV-01-MLR)
  • S201A-WL

Europe

To ensure compliance with RF exposure requirements the sensor must be installed to provide a minimum of 20 cm between the device and people.
Radiated Power:

  • SBV-01/S201A = 16dBm mean EIRP;
  • S203A = 17dBm mean EIRP.

Australia / New Zealand

For sensors:

For control units:

South Korea – KC

R-R-InX-SBV-01
Additional information of conformity registration:

S201A (SBV-01) Equipment name: non-specific wireless device (frequency band from 57 to 66 GHz)

R-R-InX-S203A
Additional information of conformity registration:

S203A Equipment name: non-specific wireless device (frequency band from 57 to 66 GHz)

R-R-InX-ISC-B01
Additional information of conformity registration:

C201A (ISC-B01), C202A (ISC-02), C203A (ISC-03), C201B, C202B, C203B. Equipment name: C201A (ISC-B01)

For S201A (SBV-01), C201A (ISC-B01), C202A (ISC-02), C203A (ISC-03), S203A, C201B, C202B, C203B:

This equipment is intended for commercial use (Class A). Operation of this equipment in a residential area may cause harmful interference.

For S201A (SBV-01) and S203A:
This device has to be used at a distance of more than 20 cm from the human body (head/torso) during normal use.

Japan
How to access the e-label:

  1. Open the Inxpect Safety application.
  2. In the Connect to Device page, click on “Regulatory certifications” in the bottom right corner and scroll down to find the MIC logo and certificate number of the device you are using.
  3. If you are already connected to an actual device, please click on Settings within the Inxpect Safety application and search for “Regulatory certifications” in the left menu. Then scroll down to find the MIC logo and certificate number.

For S201A-W and S201A-WL:

For S203A-W and S203A-WL:

Brazil – ANATEL

South Africa – ICASA
How to access the e-label:

  • Open the Inxpect Safety application.
  • In the Connect to Device page, click on “Regulatory certifications” in the bottom right corner and scroll down to find the ICASA logo and certificate number of the device you are using.
  • If you are already connected to an actual device, please click on Settings within the Inxpect Safety application and search for “Regulatory certifications” in the left menu. Then scroll down to find the ICASA logo and certificate number.

TA 2022-1881 APPROVED

ICASA certificate number for S201A/SBV-01.

Hong Kong

Only for SBV-01/S201A

Singapore – IMDA
Only the use of S201A is allowed in Singapore.

Radiated Power:

  • SBV-01/S201A = 16dBm mean EIRP;
  • S203A = 17dBm mean EIRP.

Mexico

For S201A:

  • IFT: SEINS223-05436
  • For S203A:
  • IFT: SYINS223-36435

National Configurations

Installation and use in the USA
During the first configuration of Inxpect SRE 200 Series, choose the USA country in the first start wizard of the Inxpect Safety software, in order to comply with the FCC regulations of the USA. Also select the right operating environment when available. The use of the following device is forbidden in the USA:

  • S201A-MLR (SBV-01-MLR)

Installation and use in Canada
During the first configuration of Inxpect SRE 200 Series, choose Canada country in the first start wizard of the Inxpect Safety software, in order to comply with the ISED regulations of Canada. The use of the following device is forbidden in Canada:

  • S201A-MLR (SBV-01-MLR)
  • S201A-WL
  • S203A-WL

Installation and use in Japan
During the first configuration of Inxpect SRE 200 Series, choose Japan country in the first start wizard of the Inxpect Safety software, in order to comply with the regulations of Japan. The use of the following device is forbidden in Japan:

  • S201A
  • S201A-MLR (SBV-01-MLR)

National Configurations addendum
Inxpect SRE 200 Series

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals