G-RAID® SHUTTLE 4/8/SSD
Transportable Hardware RAID Storage System
User Manual
ACCESSING SUPPORT
- For online technical support visit sandiskprofessional.com/support
- To speak with technical support visit: sandisk.com/about/contact/customer-care
INTRODUCTION
WELCOME
Thank you for purchasing the SanDisk® Professional G-RAID® SHUTTLE, featuring
40 Gb/s Thunderbolt™ 3 and 10 Gb/s USB-C™ interface technology. Specifically
designed for professional content creation applications, the G-RAID Shuttle
storage system provides RAID functionality for both application performance
and data protection. RAID 0, 1, 1E, 5, 10, JBOD for Shuttle 4, RAID 0, 1, 1E,
5, 6, 10, 50, 60, and JBOD for Shuttle 8, and RAID 0, 1, 1E, 5, 10, 50, and
JBOD for SSD.
The drive supports Thunderbolt™ 3 technology which enables blazing fast,
concurrent data streams, capable of data bandwidth of up to 2800 MB/s**
(depending on capacity and host device). This opens up incredible time-saving
and multi-stream possibilities for content creation professionals who use
bandwidth-intensive 4K, 8K, and VR workflows. With two bidirectional ports, a
user can easily daisy chain up to six high-speed Thunderbolt peripheral
devices, including external disk drives, video capture devices and external
displays. G-RAID Shuttle devices support the industry’s most demanding
professional content creation applications, including Final Cut Pro®, Adobe
Premiere® and Avid™ Media Composer.
SAFETY PRECAUTIONS
Your G-RAID Shuttle warranty may be voided as a result of failing to respect the precautions listed below. If you detect a problem with your drive, please contact our Technical Support department. If the product is returned with damage caused by improper handling, the warranty will be void and liability will rest with the user. Please read our Limited Warranty.
- Servicing: Your drive contains no user-serviceable parts. If it appears to be malfunctioning, have it inspected by a qualified Technical Support representative.
- Moisture: Place the device away from moisture or liquids. To reduce the risk of damage, do not expose this drive to rain or moisture. Do not use it in damp or wet conditions. Never place objects containing liquids on the drive as they may spill into its openings.
- Ventilation: Place the device in a vented area. The drive should never be placed near or over a radiator or heat source.
- Temperature: Do not expose this drive to temperatures outside the range of 5°C to 35°C (41°F to 95°F). It should also not be exposed to operational humidity beyond 5% to 80% (non-condensing) or nonoperating humidity beyond 10% to 90% (non-condensing). Avoid placing your drive near a source of heat, exposing it to sunlight (even through a window), or setting it in an environment that is too cold or humid.
- Physical Damage: Do not place heavy objects on the drive. Never use excessive force on your drive.
HANDLING PRECAUTIONS
SanDisk Professional products are precision instruments and must be handled
with care. It may be damaged by rough handling, shock, or vibration. Always
observe the following safety precautions:
- Avoid touching the G-RAID Shuttle device’s connector.
- Do not block any of the enclosure’s ventilation slots.
- Always lift the G-RAID Shuttle device by its top-handle, using another hand under its base to steady it if needed.
- Do not remove, damage, or cover any device labels.
- Ensure the G-RAID Shuttle device does not exceed maximum operating temperature.
- Exercise caution when handling a G-RAID Shuttle device as the G-RAID Shuttle device may have heated up.
SETUP
WHAT’S IN THE BOX
The following items are included in the box:
- G-RAID Shuttle storage system
- Removeable Enterprise-class drive modules (installed in unit)
- (1) Thunderbolt™ 3 cable (40 Gbps)
- Power Cord
- Quick Start Guide
- 5-year limited warranty
If any items are missing, please contact SanDisk Professional support:
Download the latest G-RAID Shuttle user manual and utilities:
-
G-RAID Shuttle 4
◦ https://support-en.sandiskprofessional.com/app/products/product- detail/p/2377 -
G-RAID Shuttle 8
◦ https://support-en.sandiskprofessional.com/app/products/product- detail/p/2375 -
G-RAID Shuttle SSD
◦ https://support-en.sandiskprofessional.com/app/products/product- detail/p/2378
SYSTEM REQUIREMENTS
G-RAID Shuttle supports the following operating systems:
- macOS 10.15+
- Windows 10+ (via reformat)
For maximum performance, the G-RAID Shuttles come in RAID 5 out of the box and supports RAID 0, 1, 1E, 5, 6, 10, 50, 60, and JBOD to provide a versatile and flexible storage solution.
INSTALLING G-RAID SOFTWARE UTILITY
G-RAID Shuttle devices ship preconfigured in RAID 5 and are ready to use out
of the box without configuration. However, SanDisk Professional recommends
installing the G-RAID Software Utility even if you do not plan to make any
changes to device configuration. The applications are useful for monitoring
the system and getting firmware updates.
Additionally, the utility is necessary if you plan to change the enclosure’s
default RAID configuration (RAID 5) or if you will swap out any of the pre-
installed hard drives. The G-RAID Software Utility installation package is
available on the SanDisk Professional website and can be easily downloaded.
Follow the instructions below to easily install the G-RAID Software Utility:
-
Visit the following page to download the G-RAID Software Utility based on your G-RAID device and operating system:
• G-RAID Shuttle 4
• G-RAID Shuttle SSD
• G-RAID Shuttle 8 -
Mount the virtual drive containing the installation software package.
The version number of the .dmg file and .pkg file will change as it is updated. -
Double-click on the software package to begin the installation.
The introduction window explains that software will be installed on your computer. You can review the software license agreement. Once ready, click the Continue button to proceed. -
The software license agreement will appear. Read the statement and click Continue to proceed.
-
Click Agree if you agree to the terms of the license. To read the license, click Read License. Choose Disagree if you do not agree with the terms.
This will terminate the installation procedure. -
Click Install to begin the installation process.
-
The G-RAID Shuttle Software Utility will install in a few moments.
Once complete, a message will inform you that the installation was successful. Click Close to complete the installation procedure.
The G-RAID Software Utility is now available to help manage your GRAID Shuttle. Use this tool if you need to modify the array configuration, retrieve system information or update the enclosure firmware. The utility tool is also useful for monitoring the storage system status as well as troubleshooting. For more information on using the G-RAID Shuttle, including instructions on how to use the Wizard menu or configure a different RAID array configuration, see Managing the Disk Array chapter.
G-RAID SHUTTLE HARDWARE
OVERVIEW
G-RAID Shuttle ships from the factory preconfigured in RAID 5. The RAID
controller also supports Protected RAID modes. RAID 0, 1, 1E, 5, 6, 10, 50,
60, and JBOD for Shuttle 8, RAID 0, 1, 1E, 5, 10, and JBOD for Shuttle 4, and
RAID 0, 1, 1E, 5, 10, 50, and JBOD for SSD. For an explanation of these RAID
levels, see RAID Levels in the Support, Chapter 6.
G-RAID SHUTTLE 4 AND G-RAID SHUTTLE SSD
Front Panel (G-RAID Shuttle 4)
Refer to the illustration 3.1 below.
- Removable Disk Drives
- Drive Module Power/Activity LED
- LED Indicator
Front Panel (G-RAID Shuttle SSD)
Refer to the illustration 3.2 below.
- Removable Disk Drives
- Drive Module Power/Activity LED
- LED Indicator
Rear Panel
Refer to the illustration 3.3 below.
- Smart Cooling Fans
- Alarm Mute Button
- Thunderbolt 3 Ports
- Power Button
- Kensington Slot
- AC Input
G-RAID SHUTTLE 8
Front Panel
Refer to the illustration 3.4 below.
- Removable Disk Drives
- Drive Module Power/Activity LED
- LED Indicator
Rear Panel
Refer to the illustration 3.5 below.
- Smart Cooling Fans
- Alarm Mute Button
- Thunderbolt 3 Ports
- Power Button
- Kensington Slot
- AC Input
DRIVE ACTIVITY LED
Under normal operation, each G-RAID HDD or SSD module has an LED that glows
blue, indicating a connection to the RAID controller. The LED will flash when
the drive is being accessed.
WARNING LED AND ALARMS
The G-RAID Shuttle enclosures integrate an audible alarm or buzzer that will
sound when any of the following conditions exist:
- Internal temperature exceeds a temperature of 60°C.
- Main cooling fan fails
- Fan slows to a state where the fan can no longer adequately cool the system
To silence the alarm, push the Alarm Mute button located on the back of G-RAID
Shuttle as shown above.
In addition to the audible alarm, the LED located on the front G-RAID Shuttle
will illuminate red.
If there is an issue with a G-RAID drive module, the LED on the module will
glow red indicating a drive or RAID issue. Please launch the G-RAID Software
Utility to determine if any user action is required or contact our support
team for further troubleshooting. If you hear an audible alarm and see the red
warning LED on G-RAID Shuttle front, stop using the enclosure and contact
SanDisk Professional support.
DAISY CHAINING, USB-C™ MODE, AND USB POWER DELIVERY
G-RAID Shuttles have dual Thunderbolt 3 ports, one for connecting to your
computer and the other for daisy chaining up to 5 additional devices – keeping
you connected to multiple drives, 4K displays, and more, through a single
connection to your computer. To daisy chain multiple Thunderbolt devices to
your G-RAID Shuttle, follow these steps:
- Use a Thunderbolt 3 cable to connect one of the Thunderbolt ports on the back of your computer to the Thunderbolt port (marked with a computer icon) on your G-RAID Shuttle.
- Use another Thunderbolt 3 cable to connect the second Thunderbolt port on G-RAID Shuttle with one of the Thunderbolt ports on a second device.
- Use additional Thunderbolt 3 cables to link subsequent storage enclosures or Thunderbolt 3-enabled devices into the daisy chain via available Thunderbolt ports.
USB-C™ Mode
G-RAID Shuttle ports also support high speed transfers over USB-C™ (10Gbps).
USB Power Delivery
With support for up to 85 watts of USB Power Delivery through the USBC™ port,
G-RAID Shuttle devices can charge your compatible MacBook or MacBook Pro
without having to take a separate MacBook charger out of your bag.
G-RAID SOFTWARE UTILITY
OVERVIEW
The G-RAID Software Utility interface consists of menus and icons, each
leading you to a specific function.
MENU BAR
The menu bar consists of the following options:
- G-RAID Software Utility – About, Checking for Updates, Preferences, Services, Hide, Quit
- View – Show/Hide Toolbar, Customize Toolbar, Devices (G-RAID Shuttle units)
- Dashboard – Display the Dashboard
- Storage – Wizard, Disk Array List, Logical Drive List, Spare Drive List
- Admin – System Information, Events, Background Activities, System Updates, Performance Monitor and Restore Factory Defaults
- Window – Minimize, Zoom, Close Window, Bring All to Front, G-RAID Shuttle unit
- Help – Links to Online help and the Support Site
TOOLBAR ICONS
The dashboard displays the following icons on the top toolbar:
- Dashboard – Displays the Dashboard and overview
- Wizard – Displays the Wizard options for quickly setting up RAID arrays
- Physical Drive – Displays the physical drive list, settings and functions
- Disk Array – Displays menu for monitoring, managing and creating disk arrays
- Logical Drive – Displays the logical drive list, settings and functions
- System Information – Displays G-RAID Shuttle information and settings
- Events – Displays the Event logs
- Background Activity – Display or run background tasks
UNLOCKING THE USER INTERFACE
By default, the user interface (UI) is locked to prevent unauthorized changes
to your RAID system. When the UI is locked, you cannot create logical drives
or change settings on your G-RAID Shuttle.
To unlock the UI, do the following:
- At the lower-left of the G-RAID Software Utility window, click the closed lock icon.
- The G-RAID Software Utility password dialog box will open. Enter your computer password into the Password field, then click OK.
- The closed lock icon will change to an open lock icon.
- You can now add and delete logical drives, make setting changes, run background activities and update your G-RAID Shuttle.
SAVING A SERVICE REPORT
A service report can be useful to technical support for troubleshooting or
diagnosing device issues.
To save a service report to your computer, do the following:
- Click on the System Information link.
- Click on Save Service Report.
- A prompt will ask where you want to save the HTML file containing the service report. Choose a location, then click Save.
- A technical support representative might ask you to email this file for system analysis.
UPDATING FIRMWARE
For optimal controller and system hardware performance, it is a good idea to
keep your G-RAID Shuttle firmware up to date. Download the latest firmware
from the SanDisk Professional support website at https://support-
en.sandiskprofessional.com/ and save the firmware file on your computer.
Note that after the update process completes, you will need to restart your
computer for the changes to take effect.
To update the controller firmware:
- From the Admin drop-down menu in the menu bar at the top of your desktop, choose System Update.
- Click on the padlock icon to unlock the menu, then type in the password for your computer when the prompt appears.
- Click Choose File and locate the firmware file you downloaded from the SanDisk Professional support website.
- Click Submit.
- In the Confirmation box, enter CONFIRM in the field provided and click Confirm.
- The process will take several seconds. When complete, you will be prompted to restart your computer. Restart your computer and continue using your G-RAID Shuttle.
MANAGING THE DISK ARRAY AND LOGICAL DRIVE
CREATING A DISK ARRAY AND LOGICAL DRIVE MANUALLY
A disk array is a method of organizing data across a grouping of hard disks or
solid state drives. One or more logical drives can be created on top of a disk
array.
A logical drive is what mounts to your computer, which it sees as a single
namespace, or as individual drives. The logical drive is where your disk’s
file format is defined and is also where your system saves the files.
Create a Disk Array
This feature only creates a disk array. You can also use the Wizard to create
a disk array with logical and spare drives concurrently.
To create a disk array:
-
From the Dashboard menu, click the Disk Array link.
-
Click Create Disk Array.
-
Accept the defaults or make changes:
• Enter an alias in the Alias field with a maximum of 32 characters (letters, numbers andspaces between characters).
• Enable Media Patrol – Uncheck to disable on this array.
• Enable PDM – Uncheck to disable on this array. -
In the Select Physical Drives diagram, click drives to add them to your array. The drive carriers turn blue when you click them. The physical drives’ ID numbers will appear in the field below the diagram.
-
When you have finished your settings and chocies, click Submit.
The new array will appear in the list.
- If you are done creating disk arrays, click Finish.
- To create additional disk arrays, click Create More.
After you create a disk array, you will need to create a logical drive on it.
Create a Logical Drive
This feature creates a logical drive only. You can also use the Wizard to
create a disk array with logical drives and spare drives concurrently. See
Creating a Disk Array and Logical Drive with Wizard.
To create a logical drive manually:
-
Choose one of the following actions:
• Click the Logical Drive icon.
• From the Storage menu, choose Logical Drive. -
Click Create Logical Drive.
-
Click the radio button of the disk array you want to use, then click Next.
-
Accept the defaults or make changes from the following:
• Optional. Enter an alias in the Alias field with a maximum of 32 characters (letters, numbers, and spaces).
• Choose a RAID level. The choice of RAID levels will depend in part on the number of physical drives in the disk array.
• In the Capacity field, accept the default maximum capacity or enter a lesser capacity in MB, GB, or TB. Any remaining capacity will be available for an additional logical drive.
• Choose a Stripe size: 64KB, 128KB, 256KB, 512KB and 1MB are available.
• Choose a Sector size: 512KB, 1KB, 2KB and 4KB are available.
• Choose a Read (cache) Policy: Read Cache, Read Ahead and No Cache are available.
• Choose a Write (cache) Policy: Write Back and Write Through (Thru) are available.
The Write Cache is always set to WriteThru when the Read Cache is set to NoCache.
• If you want the G-RAID Software Utility to format your logical drives, leave the Format box checked. -
Click Add. The new logical drive will appear on the list at the right. If any capacity remains. you can create an additional logical drive. G-RAID Shuttle (8) supports up to 32 logical drives.
-
When finished, click Submit. The new logical drives(s) will appear in the logical drive list.
The new Volume will appear on the desktop.
CREATING A DISK ARRAY AND LOGICAL DRIVE WITH THE WIZARD
The G-RAID Software Utility includes a Wizard to help you set up a disk array,
logical drives and spare drives. To open the Wizard, click the Storage menu
and choose Wizard. The Wizard dialog box will open and offer three
configuration methods: Automatic, Express, or Advanced.
Wizard dialog box
Choose the best method for your needs as per the following table:
Method | User Options | Suggested for users who are |
---|---|---|
Automatic | None | New to data storage |
Express | General parameters | Familiar with data storage |
Advanced | Individual parameters | Data storage professionals |
Automatic Configuration
To use the Automatic Configuration Wizard:
- From the Storage menu, choose Wizard.
- Click the Automatic button.
The Automatic Configuration dialog box will appear.
Do one of the following actions:
-
If you agree with the proposed configuration, click the Submit button.
The Wizard will create your disk array and logical drive. The Wizard can also create a spare drive. -
If you do NOT agree with the proposed configuration, click the Cancel button to return to the original Automatic Configuration menu.
Express Configuration
To use the Express Configuration Wizard:
-
From the Storage menu, choose Wizard.
-
Click the Express button.
The Express Configuration dialog box will appear. -
Check the boxes to choose any one or a combination of:
• Data Redundancy – The array remains available if a physical drive fails
• Media Capacity – The greatest possible amount of data capacity
• Drive Performance – The highest possible read/write speed
• Spare Drive – Check box to create a hot spare drive
• Number of Logical Drives – Enter a number of logical drives to create
• Application Type – Choose how the storage will be used -
In the Number of Logical Drives field, type the number of logical drives you want to make from this disk array.
-
From the Application Type drop-down menu, choose an application that best describes your intended use for the logical drives.
-
Click the Next button to continue.
The Summary dialog box will appear with information about the disk arrays,
logical drives andspare drives you are about to create.
Perform one of the following actions:
-
If you accept these parameters, click the Submit button.
The Wizard will create your disk array, logical drives, and a spare drive. -
If you do NOT accept these parameters, click the Back button, then review and modify your choices.
-
Press Cancel to dismiss the configuration all together.
ADVANCED CONFIGURATION
This option enables you to specify additional parameters for a new disk array,
logical drives and spare drives.
To use the Advanced Configuration Wizard:
- From the Storage menu, choose Wizard.
- Click the Advanced button.
To Create Disk Array screen will display.
Task 1 – Disk Array Creation
To create your disk array:
-
Accept the defaults or make changes to any of the following:
• Enter an alias in the Alias field, up to a maximum of 32 characters (letters, numbers andspaces between characters).
• Media Patrol – Uncheck to disable on this array.
• PDM – Uncheck to disable on this array. -
In the Select Physical Drives diagram, click the desired drives to add them to your array. Drive carriers turn blue when you click them. The physical drives’ ID numbers appear in the field below the diagram.
-
Click Next.
The Create Logical Drive screen will display.
Task 2 – Logical Drive Creation
To create your logical drive:
-
Enter your information and choose your options.
• Enter a logical drive alias in the field provided.
• Choose a RAID level from the drop-down menu. Note the max capacity value, then enter acapacity value in the field provided and choose a unit of measure from the drop-down menu.
• Enter a value for capacity and choose the appropriate size unit of measurement (MB, GB or TB).
• Choose a Stripe size: 64 KB, 128 KB, 256 KB, 512 KB and 1 MB are available.
• Choose a Sector size: 512 B, 1 KB, 2 KB, and 4 KB are available.
• Choose a Read Cache Policy: The choices are Read Cache, Read Ahead (cache), and None.
• Choose a Write (cache) Policy: The choices are WriteThru and WriteBack.
WriteBack requires a ReadCache or Read Ahead/Read Cache Policy.
• If you want the Utility to format your logical drives, leave the Format box checked. -
Click Add. The new logical drive will appear on the list at the right. If any capacity remains, you will have the option to create an additional logical drive.
-
Click Next.
The Create Spare Drive screen will display.
Task 3 – Spare Drive Creation
To create your spare drive:
-
For each of the following items, accept the default or change the following settings as required:
• Check the Revertible box if you want a revertible spare drive. A revertible spare drivereturns to its spare drive assignment after you replace the failed physical drive in the diskarray and run the Transition function.
• Global – Allows the spare to be used by any disk array.
• Dedicated – Restricts the drive to only working with the disk array you are now creating. -
In the Select Physical Drives diagram, click a drive to choose it for your spare. The drive carrier will turn blue when you click it. The physical drive’s ID number will appear in the field below the diagram.
-
Click Next.
The Summary screen will display.
Task 4 – Summary
-
Review your choices of disk array, logical drives and spare drive.
• To make any changes, click Back to reach the appropriate screen.
• To accept, click Submit. Creating the disk array, logical drive, and spare drive will take a few moments. -
In the Select Physical Drives diagram, click the desired drives to add them to your array. Drive carriers turn blue when you click them. The physical drives’ ID numbers appear in the field below the diagram.
-
Click Finish to close.
REBUILDING A DISK ARRAY
When you rebuild a disk array, you actually rebuild data on one or more
physical drive sfrom redundant data maintained on other drives. If there is no
spare drive of adequate capacity, you must replace the failed drive with an
unconfigured physical drive, then perform a Manual Rebuild.
On the carrier with the failed drive, the drive power/ status LED will be red.
Performing A Manual Rebuild
To perform a manual rebuild:
- Click on the Background Activities icon.
- Mouse-over Rebuild, then click Start.
- From the Source Physical Drive drop-down menu, choose a Source disk array and physical drive. Arrays have an ID number. Physical drives have a sequence number.
- From the Target Physical Drive drop-down menu, choose a Target physical drive.
- In the Confirmation box, type the word “CONFIRM” in the field provided, then click Confirm. While the disk array is rebuilding:
• The disk array will show a green check icon and a Rebuilding status.
• Logical drives under the disk array will continue to show a yellow “!” icon and a Critical, Rebuilding status.
• If the buzzer is enabled, your G-RAID Shuttle device will emit two quick beeps every five seconds. When the beeps stop, the rebuild is complete.
REPLACING A BAD DRIVE
The G-RAID Shuttle RAID Controller continually monitors the health of each disk drive in the G-RAID Shuttle device. In the event of a disk failure, you will be alerted based on the notification settings you entered in Set Up Alert Notifications. G-RAID Shuttle will report the failed drive and help you locate its physical position in the G-RAID Shuttle device enclosure.
MUTING THE ALARM
By default, G-RAID Shuttle has the audible alarm enabled. If a drive fails or
other critical events occur, the alarm will become audible. To mute the
audible alarm, you can press the Alarm Mute button on the back of the
enclosure or you can launch the G-RAID Software Utility. In the utility under
the controller settings, there is a Buzzer section you can use to mute the
alarm.
This same area can be used to test the alarm by simply clicking on Sound.
NOTE: If your G-RAID Shuttle was configured in RAID 1 or RAID 5 mode, a drive failure does not necessarily result in data loss. However, the array will now operate in a degraded and unprotected state. The failed drive should be replaced as soon as possible to avoid data loss.
IDENTIFYING AND REPLACING FAILED A DRIVE
-
Launch the G-RAID Software Utility.
-
Select the Physical Drive.
-
The Physical Drive List will show all of the drives and next to its name the status will indicate Dead.
-
Right-click on the failed drive and select Locate.
WARNING: Make absolutely sure that you remove the correct drive as indicated in the steps below. REMOVING THE WRONG DRIVE CAN RESULT IN LOSS OF THE ARRAY AND ALL CONTENT STORED ON YOUR G-RAID Shuttle. -
The failed drive’s LED will begin to blink in the G-RAID Shuttle enclosure, making it easy to identify which drive needs to be replaced.
Be certain to remove the correct drive, as removing the wrong drive could cause data loss.
NOTE: It is possible for the failed drive to be completely offline. In this case, the drive’s activity LED will be entirely turned off, indicating the failed drive. -
Remove the failed drive by pressing the release button and sliding the drive out of the enclosure.
-
Replace the failed drive with a new disk module and secure the module in place. Once the drive is connected, the G-RAID Software Utility will indicate that the array is rebuilding. Rebuild time is approximately two hours per terabyte.
Once the rebuild is complete, G-RAID Shuttle will be back to normal,
protecting your valuable data with optimal efficiency.
NOTE: Replacement and/or extra G-RAID Shuttle HDD and SSD modules are
available for purchase online at: https://www.westerndigital.com/brand
/sandisk-professional
SUPPORT
TECHNICAL SUPPORT
Thank you for purchasing the G-RAID Shuttle storage system. If you have any
comments or questions about this manual or the product, please let us know!
SanDisk Professional appreciates and values its customers. We strive to give
you the finest service and support. If you encounter any difficulties while
installing or using your G-RAID Shuttle, please contact SanDisk Professional
Technical Support at:
https://www.westerndigital.com/support/international-phone-numbers
Helpful Information for Support
When contacting Technical Support, it’s best to be in front of your computer
and have the following information available:
- Your G-RAID Shuttle serial number (on bottom of unit)
- Operating System and version
- Computer model
- List of other devices attached to your computer
COMMON RAID LEVELS
RAID Level| Description| Advantage| Disadvantage| Ideal
for
---|---|---|---|---
0| Disk striping| Offers the highest performance and a 100% of total
available storage capacity| No fault tolerance –failure of one drive in the
array results in complete data loss| Content creation applications requiring
highest performance and storage capacity
1| Mirroring| Maximum level of data protection:
identical data is written to multiple drives| Usable storage space is 50% of
total available capacity when using only two drives| Applications in which
data security is paramount
5 (Preconfigured)| Disk striping with parity| High read performance, medium
write performance with data protection in| Usable storage capacity equals
total capacity of all drives in the array less the capacity of one drive|
Content creation applications requiring data protection and performance
| | case of a drive failure| |
10| Built from two or more equalseized RAID 1 arrays| Mirroring provides data
protection, and striping improves performance| Usable storage space is 50%
of total available capacity| Content Backup and Content creation applications
with data protection
JBOD| Just-a-bunch-ofdisks| Each drive can be accessed as an individual
volume. Usable storage capacity is 100% of total available storage| No fault
tolerance| Audio applications
IMPORTANT INFORMATION
STOP! IMPORTANT INFORMATION.
READ THE FOLLOWING CAREFULLY BEFORE USING THIS PRODUCT. KEEP THESE
INSTRUCTIONS FOR FUTURE REFERENCE.
SAFETY INSTRUCTIONS
Additional Safety Instructions:
Keep the SanDisk Professional device away from direct sunlight, moisture, and
temperature extremes. Do not bend, flex, or drop your SanDisk Professional
device. The user is responsible for complying with all environmental, safety,
and other usage specifications.
Keep the SanDisk Professional device away from sinks, drinks, bathtubs,
showers, rain, and other sources of moisture. Moisture can cause electric
shocks with any electronic device. Do not disassemble, crush, short circuit,
or incinerate the SanDisk Professional device as it may cause fire, injury,
burns, or other hazards.
Disposal Instructions:
Do not dispose of the SanDisk Professional device with unsorted waste.
Improper disposal may be harmful to the environment and human health. Please
refer to your local waste authority for information on return and collection
systems in your area.
OBTAINING SERVICE
SanDisk Professional values your business and always attempts to provide you
the very best of service. Should you encounter any problem, please give us an
opportunity to address it before returning this Product. Most technical
support questions can be answered through our knowledge base or e-mail
support service at http://www.sandiskprofessional.com/support.
LIMITED WARRANTY – EXCEPT AUSTRALIA
Warranty Information
This SanDisk Professional device is covered by a 5-year limited warranty (or
5-year warranty in regions not recognizing “limited”) from the date of
purchase, subject to the applicable warranty terms and conditions, as defined
in www.sandisk.com/wug.
How to Make a Warranty Claim
Please go to https://www.westerndigital.com/support and select “support” for
more information on making a warranty claim (SanDisk Professional Support
Page).
If it is determined that your product may be defective, you will receive an
RMA and product return instructions. You are responsible for any expenses
associated with a claim under SanDisk Professional’s Limited Warranty.
You must send your product in a secure, prepaid package, to the address
provided with your RMA number. Proof of purchase is required for all warranty
claims.
LIMITED WARRANTY – AUSTRALIA
Warranty Information
SanDisk Professional warrants to the end user, that this product, excluding
content and or software supplied with or on the product, will be free from
material defects in manufacture, will conform to SanDisk Professional’s
published product specifications and be fit for normal use for a period of 5
years from the date of purchase, provided that the product is legally placed
on the market.
When making a claim under this Limited Warranty, SanDisk Professional may at
its option repair this product or provide you with an equivalent product; and
if unable to repair or replace the product, will refund the purchase price.
The full terms of SanDisk Professional’s warranty and warranty period are
available at: www.sandisk.com/wug.
Warrantor Details
Western Digital Technologies, Inc., 951 SanDisk Drive, Milpitas, CA 95035,
U.S.A.
Tel: 1 (800) 275-4932 (US local toll free) or 1 (310) 449-4599 (US)
How to make a warranty claim:
Before you return the product you must first obtain a Return Material
Authorization (RMA) number. Please either:
- Contact SanDisk Professional at 1 800 262 504 (M-F | 9 am – 6 pm New South Wales Time) or email SanDisk Professional (support@sandiskprofessional.com) and provide proof of purchase (showing date and place of purchase and name of the reseller) and product name, type and number; or
- Contact the dealer from whom you originally purchased the product.
Please go to
www.sandiskprofessional.com/support
for more information on making a warranty claim (SanDisk Professional Support
Page).
If it is determined that your product may be defective, you will receive an
RMA number and product return instructions. You are responsible for any
expenses associated with a claim under SanDisk Professional’s Limited
Warranty. You must send your product in a secure, prepaid package, to the
address provided with your RMA number. Proof of purchase is required for all
warranty claims.
Australian consumers only:
Notwithstanding the terms of this Limited Warranty, SanDisk Professional’s
products come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and for compensation for any other reasonably foreseeable loss or damage. You
are also entitled to have the products repaired or replaced if the products
fail to be of acceptable quality and the failure does not amount to a major
failure.
REGULATORY COMPLIANCE
Regulatory Compliance – FCC
FCC CLASS B INFORMATION
NOTE: This device has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation. This device generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this device does cause harmful interference to radio or
television reception, which can be determined by turning the device off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the device and receiver.
- Connect the device into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the manufacturer could
void the user’s authority to operate the device.
Safety Compliance – US and Canada
Safety Compliance
Approved for US and Canada. CAN/CSA-C22.2 No. 62368-1-14: Audio/ Video,
Information and Communication Technology Equipment Part 1:
Safety Requirements.
Approuvé pour les Etats-Unis et le Canada. CAN/CSA-C22.2 No.
62368-1-14, Sûreté d’équipement de technologie de l’information.
Regulatory Compliance – CE
CE Compliance for Europe
Hereby, Western Digital declares compliance of this equipment to the
applicable Council Directives of the European Union, including the EMC
Directive (2014/30/EU), the Low Voltage Directive (2014/35/EU) and the RoHS
Directive (2011/65/EU) as amended by Directive 2015/863/EU. The full text of
the EU declaration of conformity is available at the following internet
address: http://www.wdc.com/products/EUDoC.
- PO Box 13379, Swords, Co Dublin, Ireland
- PO Box 471, Leatherhead, KT22 2LU, UK
Regulatory Compliance – Austria
http://www.wdc.com/products/EUDoC
Index
A
advanced configuration 15 alarms 9
Australian Consumers Only 23
B
box contents 3
C
CE 25
contents, box 3
creating disk array 13
creating disk array and logical drive with wizard 14 CSA 24
D
daisy chaining 10
drive activity LED 9
E
EAC 26
express configuration 15
F
FCC 24
front panel, G-RAID Shuttle 4 5
front panel, G-RAID Shuttle 8 8
front panel, G-RAID Shuttle SSD 6
G
G-RAID software utility 3
H
handling precautions 2
hardware overview 5
I
identifying and replacing failed drive 18
Important Information 22
install G-RAID software utility 3
L
LED, drive activity 9
LED, warnings and alarms 9
M
muting the alarm 18
O
Obtaining Service 22
P
precautions, handling 2
precautions, safety 1
R
RAID levels 20
rear panel, G-RAID Shuttl 8 9
rear panel, G-RAID Shuttle 4 7
rear panel, G-RAID Shuttle SSD 7
rebuilding a disk array 17
Regulatory Compliance – Austria 25
Regulatory Compliance – CE 25
Regulatory Compliance – China 26
Regulatory Compliance – FCC 24
Regulatory Compliance – Japan 25
Regulatory Compliance – Korea 25
Regulatory Compliance – Russia 26
Regulatory Compliance – Taiwan 26
replacing a bad drive 18
requirements, system 3
S
Safety Compliance – US and Canada 24
Safety Instructions 22
safety precautions 1
system requirements 3
T
technical support 20
U
USB power delivery 10
USB-C mode 10
W
warning LED and alarms 9
warnings 9
Warranty Information 22
Warranty Information – Australia 23
welcome 1
What’s in the Box 3
wizard dialog box 14
Information furnished by Western Digital is believed to be accurate and
reliable; however, no responsibility is assumed by Western Digital for its use
nor for any infringement of patents or other rights of third parties which may
result from its use. No license is granted by implication or otherwise under
any patent or patent rights of Western Digital.
SanDisk, the SanDisk logo, the SanDisk design, SanDisk Professional, the
SanDisk Professional logo, and G-RAID are trademarks of Western Digital
Corporation or its affiliates in the United States and/or other countries.
Thunderbolt and the Thunderbolt logo are trademarks of Intel Corporation in
the U.S. and other countries. Apple, Mac, MacBook Pro, and Time Machine are
trademarks of Apple, Inc. Windows is a registered trademark or trademark of
Microsoft Corporation in the US and/or other countries. Other trademarks are
the property of their respective owners.
Pictures shown may vary from actual products. Product specifications subject
to change without notice. *As used for storage capacity, 1TB = one trillion
bytes. Actual user capacity may be less depending on operating environment and
RAID configuration. For RAID products, storage capacity is based on RAID 0
mode. **As used for transfer rate, 1 MB/s = 1 million bytes per second. Based
on internal testing; performance may vary depending upon host device, usage
conditions, drive capacity, RAID configuration, and other factors.
Western Digital Technologies, Inc. is the seller of record and licensee in the
Americas of SanDisk® products.
© 2022 Western Digital Corporation or its affiliates. All rights reserved.
Western Digital
951 SanDisk Drive
Milpitas, California 95035 U.S.A
D015-000064-AA00
References
- Support | Western Digital
- Support | Western Digital
- Support | Western Digital
- G-RAID SHUTTLE 8 | Western Digital Product Support
- G-RAID SHUTTLE 4 | Western Digital Product Support
- G-RAID SHUTTLE 4 | Western Digital Product Support
- G-RAID SHUTTLE SSD | Western Digital Product Support
- G-RAID SHUTTLE SSD | Western Digital Product Support
- Contact Customer Support | Western Digital
- SanDisk Professional Data Storage Solutions for Creatives | Western Digital
- Support | Western Digital
- Contact Customer Support | Western Digital
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>