Enerwave ZWN-RSM2-PLUS Smart Dual Relay Switch Module User Guide
- May 15, 2024
- Enerwave
Table of Contents
**Enerwave ZWN-RSM2-PLUS Smart Dual Relay Switch Module User Guide
**
The Switch Module based on Z-WaveTM Slave library of V7.18.03. This Switch
integrated Z-Wave communication module to connect with Z-Wave gateway.
The Switch Module can be included and operated in any Z-Wave network with
other Z-Wave certified devices from other manufacturers and/or other
applications. All non-battery operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the network.
The Switch Module is a security Z-Wave device (S2), so a security enabled
controller is needed for take full advantage of all functionally for the
Switch Module.
Features
- Manual or Z-Wave on/off control of 2 electrical loads.
- Add Z-Wave to two wall switches with a single device.
- Installs behind your existing wall switch.
- Remembers and restores on/off status after power failure.
- Built-in Z-Wave signal repeater.
- Smart Start and S2 Security for a safer network.
Technical Specifications
Model Number | ZWN-RSM2-PLUS |
---|---|
Z-Wave Signal Frequency | 908.42MHz |
Range | Up to 131 feet line of sight |
Power | 120~277VAC, 50/60Hz |
Maximum Load | 100W LED bulbs,500W incandescent,5A resistive per relay |
Operating Temperature | 32-104° F (0-40° C) |
Operating Humidity | Up to 85% non-condensing |
Z-Wave Specifications
SDK Version | 7.18.03 |
---|---|
SDK Library | libZWaveSlave |
Explorer Frame Support | Yes |
Routing | Yes |
SmartStart | Yes |
Device Type | Binary Switch |
Basic Device Class | BASIC_TYPE_ROUTING_SLAVE |
Generic Device Class | GENERIC_TYPE_SWITCH_BINARY |
Specific Device Class | SPECIFIC_TYPE_NOT_USED |
Role Type | Always On Slave (AOS) |
Generic Device Class | GENERIC_TYPE_SWITCH_BINARY |
Specific Device Class | SPECIFIC_TYPE_NOT_USED |
Role Type | Always On Slave (AOS) |
Familiarize yourself with Switch
Installation
Security and non-Security features
This device is a security enabled Z-Wave PlusTM product that is able to use
encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave
Plus products.
When a node includes into a S0/S2 Z-Wave network, the node supports S0/S2
unauthenticated class, S0/S2 authenticated and so do the supported CCs.
This product can be operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers. All mains operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
Supported Security Levels
- SECURITY_KEY_S0_BIT
- SECURITY_KEY_S2_AUTHENTICATED_BIT
- SECURITY_KEY_S2_UNAUTHENTICATED_BIT
All functions of each trigger
Smart Start
Smart Start enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
Add the Switch into the Z-Wave network via SmartStart (SmartStart Inclusion):
a. Add Switch DSK into the primary controller SmartStartProvisioning List
(If you don’t know how to do this, refer to its manual, DSK usually print on
the main body).
b. Remove the battery from the Switch. A few seconds later, reinsert
battery in the DUT.
c. The Switch will send “Z-Wave protocol Command Class” frame to start
SmartStart Inclusion.
LOAD will blink during the inclusion, and then solid for 2 seconds to indicate that the inclusion is successful, otherwise the LOAD will blink for 2 times in which you need to repeat the process form step b
Power on
In the network: LOAD will blink 1 time.
Not in the network:
LOAD will blink 1 time and start SmartStart..
Short press Z-Wave Button three times
Add the Switch into the Z-Wave network (Manual Inclusion):
a. Power on your Switch, set your Z-Wave controller into add/inclusion
mode.
b. Short press Z-Wave Button three times(or Short press any external key
five times).
c. LOAD will blink during the inclusion, and then solid for 2 seconds to
indicate that the inclusion is successful, otherwise the LOAD will blink for 2
times in which you need to repeat the process form step a
Remove Switch from a Z-Wave network (Manual Exclusion):
a. Power on your Switch, and let the Z-Wave primary controller into
remove/exclusion mode.
b. Short press Z-Wave Button three times(or Short press any external key
five times).
c. LOAD will blink during the inclusion, and then solid for 2 seconds to
indicate that the inclusion is successful, otherwise the LOAD will blink for 2
times in which you need to repeat the process form step a.
Reset Switch to factory default
Press and hold Z-Wave button at least 10 seconds, LOAD start blinking quickly,
release Z-Wave button. The Switch will reset itself to factory default by
sending a “Device Reset Locally Notification” to gateway when the button is
released.
Note: Please use this procedure only when the network primary controller
is missing or otherwise inoperable.
Special Rule of Each Command
Basic Command Class
Basic CC is maps to Switch Binary CC
Z-Wave Plus Info Report Command Class
Z-Wave Plus Version: 0x02
Role Type: 0x05 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON)
Node Type: 0x00 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
Installer Icon Type: 0x0700 (ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH)
User Icon Type: 0x0700 (ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH)
Association Command Class
Below is an overview of the different association groups for each the endpoints.
Endpoint| Grouping Identifier| Max Nodes| Mapping|
Send Commands
---|---|---|---|---
Root Device| 1(Lifeline Group)| 0x05|
Endpoint1 Endpoint2
| 1. Switch Binary Report.Switch will send Switch Binary Report when Switch
status changed.2. Device Reset Locally.Press and hold Z-Wave button at least
10 seconds.3.Indicator Report
2| 0x05| Endpoint1| 1. Basic Set.Switch will send Basic Set when Switch
status changed.
3| 0x05| Endpoint2| 1. Basic Set.Switch will send Basic Set when Switch
status changed.
Endpoint 1| 1| 0x00| | 1. Switch Binary Report.Switch will send Switch Binary
Report when Switch status changed.
2| 0x05| | 1. Basic Set.Switch will send Basic Set when Switch status
changed.
Endpoint 2| 1| 0x00| | 1. Switch Binary Report.Switch will send Switch Binary
Report when Switch status changed.
2| 0x05| | 1. Basic Set.Switch will send Basic Set when Switch status
changed.
Indicator Command Class
The Receptacle support the Indicator Command Class, version 3 and support the Indicator ID 0x50 (Identify) and Properties ID 0x03, 0x04 and 0x05.
Configuration Command Class
# | Name | Size | Range | Description | Default |
---|---|---|---|---|---|
0x05 | Power on status | 1 | 0~2 | When the device is powered on, the initial | |
status.0= Off | 0 | ||||
1= On2= Last State | |||||
0x13 | Child lockout enable | 1 | 0~1 | Child lockout feature can enabled and | |
disabled local control.0= Disable1= Enable | 0 | ||||
0x14 | Delayed off time | 1 | 0~240 | Delay off means when users press button to | |
turn off the load, there’s a reaction time. | 0 | ||||
Name | Info | Parame ter Numbe r | **Default Value(de | ||
c)** | Max Value(d ec) | Min Value( dec) | Size | ReadOnl | |
y | Format | Altering capabilit y | |||
--- | --- | --- | --- | --- | --- |
Power on status | Power on status | 0x05 | 0 | 2 | 0 |
edinteger | false | ||||
Child lockout enable | Child lockout enable | 0x13 | |||
0 | 1 | 0 | 1 | No read- only | Unsign edinteger |
**** Delayed off time | **** Delayed off time | 0x14 | 0 | 240 | 0 |
only | Unsign edinteger | false |