Miele DA 6698 W Ventilation Hood Instruction Manual
- May 15, 2024
- Miele
Table of Contents
DA 6698 W Ventilation Hood
Product Information
Specifications:
- Model Number: M.-Nr. 12 253 910
- Language: en-US
Product Usage Instructions
Important Safety Instructions:
-
Read all instructions before installing and using the
appliance. -
Ensure proper installation and grounding of the appliance.
-
Turn off power before servicing or cleaning the appliance.
-
Avoid leaving surface units unattended at high settings to
prevent grease fires. -
Always turn on the hood when cooking at high heat.
Cleaning and Care:
Regularly clean the stainless steel housing to maintain the
appearance of the ventilation hood. Use mild detergent and a soft
cloth to wipe down the surfaces. Avoid abrasive cleaners that may
damage the stainless steel.
Proper Installation:
Installation work and electrical wiring should be carried out by
qualified professionals to reduce the risk of fire, electric shock,
or injury. Follow the manufacturer’s guidelines for proper
installation.
Disposal of Packing Material:
Dispose of the cardboard box and packing materials in a safe and
environmentally friendly manner. Keep plastic wrappings out of
reach of children to prevent suffocation hazards.
Caring for the Environment:
When disposing of your old appliance, follow local regulations
for proper disposal. Electrical and electronic appliances contain
valuable materials that should not be disposed of in regular
household waste to protect your health and the environment.
FAQ
Q: How often should I clean the ventilation hood?
A: It is recommended to clean the ventilation hood frequently to
prevent grease buildup. Depending on usage, a monthly cleaning may
be sufficient.
Q: Can I use abrasive cleaners on the stainless steel
housing?
A: No, abrasive cleaners should be avoided as they can damage
the stainless steel surface. Use mild detergent and a soft cloth
for cleaning.
Operating and Installation Instructions Ventilation Hood
To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time.
en-US
M.-Nr. 12 253 910
Contents
IMPORTANT SAFETY INSTRUCTIONS …………………………………………………… 4 Caring for the
environment …………………………………………………………………… 13 Guide to the ventilation hood
………………………………………………………………… 14 Description of functions
……………………………………………………………………….. 16 Before using for the first time
……………………………………………………………….. 17 Selecting extraction mode or recirculation
mode………………………………………… 17 Setting up Miele@home …………………………………………………………………………..
17
Connecting via the app ………………………………………………………………………. 18 Connecting via WPS
………………………………………………………………………….. 19 Signing out of WiFi (reset to factory
settings) ………………………………………… 20 Setting up Con@ctivity
……………………………………………………………………………. 21 Con@ctivity via the home WiFi network
(Con@ctivity 3.0) ……………………….. 22 Con@ctivity via a direct WiFi connection
(Con@ctivity 3.0) ……………………… 22 Reattempting the connection
………………………………………………………………. 23 Con@ctivity with direct wireless connection
(Con@ctivity 2.0) …………………. 23 Operation (Automatic mode)
…………………………………………………………………. 27 Cooking with Con@ctivity (Automatic mode)
……………………………………………… 27 Cooking process ……………………………………………………………………………………. 27
Temporarily exiting Automatic mode …………………………………………………………. 28 Resuming
Automatic mode…………………………………………………………………. 28 Operation (Manual mode)
……………………………………………………………………… 29 Cooking without Con@ctivity (Manual mode)
…………………………………………….. 29 Turning on the blower……………………………………………………………………………… 29
Selecting the power level ………………………………………………………………………… 29 Selecting the
delayed shutdown time ……………………………………………………….. 29 Turning off the
blower……………………………………………………………………………… 29 Dimming/switching the overhead
lighting on/off…………………………………………. 29 Power management
……………………………………………………………………………….. 30 Safety shut-
off……………………………………………………………………………………….. 30 Operation (Automatic and Manual
modes) …………………………………………….. 31 Filter saturation
indicator…………………………………………………………………………. 31 Adjusting the grease filter filter
saturation indicator ………………………………… 31 Adjusting or deactivating the filter
saturation indicator for the charcoal filter 32 Checking the filter saturation
indicator………………………………………………….. 32 Energy-saving
tips………………………………………………………………………………… 33
2
Contents
Cleaning and care ………………………………………………………………………………… 34 Stainless steel
housing……………………………………………………………………………. 34
Important information for appliances with stainless steel surfaces …………… 34
Important information for appliances with lacquered housing………………….. 34 Grease
filters …………………………………………………………………………………………. 35 Replacing the grease
filter…………………………………………………………………… 36 OdorFree Charcoal Filter
…………………………………………………………………………. 37 Resetting the filter saturation indicator for
the charcoal filters………………….. 37 Disposing of charcoal filters
………………………………………………………………… 37 Installation…………………………………………………………………………………………….
38 Before installation…………………………………………………………………………………… 38 Removing the
protective film……………………………………………………………………. 38 Installation
materials……………………………………………………………………………….. 38 Appliance dimensions
…………………………………………………………………………….. 40 Distance between cooktop and ventilation
hood (S)……………………………………. 41 Installation recommendations
………………………………………………………………….. 42 Drilling diagram for wall
mounting…………………………………………………………….. 42 Plywood backing
…………………………………………………………………………………… 43 To install a plywood backing
…………………………………………………………………… 43 Air venting
…………………………………………………………………………………………….. 44 Non-return flap
………………………………………………………………………………….. 44 Condensate
………………………………………………………………………………………. 45 Reducing Collar
………………………………………………………………………………… 45 Electrical connection
………………………………………………………………………………. 46 Customer
Service…………………………………………………………………………………. 47 Contact in the event of a fault
………………………………………………………………….. 47 Location of the data plate
……………………………………………………………………….. 47 Appliance warranty and product registration
……………………………………………… 47 Technical data ……………………………………………………………………………………… 48
Optional accessories for recirculation mode………………………………………………. 48
3
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety
requirements. Improper use of the appliance can lead to personal injury and
material damage. Read all instructions before installing or using the
appliance for the first time. Only use the appliance for its intended purpose.
Keep these operating instructions in a safe place and pass them on to any
future user. Appropriate use CAUTION: For General Ventilating Use Only. Do Not
Use To Exhaust Hazardous Or Explosive Materials And Vapors. This appliance is
intended for residential use only. Use only as described in these operating
instructions. This ventilation hood is not intended for outdoor use. It must
only be used to extract and clean vapors produced during cooking. Any other
use occurs at the owner’s own risk. Where a recirculation ventilation hood is
installed above a gas cooktop, please check that all local codes are observed
to insure an adequate supply of fresh air. This appliance is suitable for
installation above gas or electric cooking surfaces. Persons who lack
physical, sensory or mental abilities, or experience with the appliance should
not use it without supervision or instruction by a responsible person.
4
IMPORTANT SAFETY INSTRUCTIONS
Safety with children Children must be kept away from the ventilation hood
unless they are constantly supervised. Children must not be allowed to clean
or service the hood. Please supervise children in the vicinity of the hood and
do not let them play with it. The LED ClearView lighting is very intense.
Avoid looking directly into the light for prolonged periods of time. Danger of
suffocation. While playing, children may become entangled in packaging
material (such as plastic wrapping) or pull it over their head, presenting the
risk of suffocation. Keep packaging material away from children. Technical
safety WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING: – Use this appliance only in the manner
intended by the
manufacturer. If you have questions, contact Miele. – Before servicing or
cleaning the appliance, switch power off at the
service panel and lock the service disconnecting means to prevent power from
being switched on accidentally. If the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the
service panel. Unauthorized installation, maintenance, and repairs can cause
considerable danger for the user. Installation, maintenance, and repairs must
only be carried out by a Miele authorized technician. A damaged ventilation
hood can be dangerous. Always check for visible signs of damage. Never use a
damaged ventilation hood.
5
IMPORTANT SAFETY INSTRUCTIONS Be certain your appliance is properly installed
and grounded by a
qualified technician. To guarantee the electrical safety of this appliance,
continuity must exist between the appliance and an effective grounding system.
It is imperative that this basic safety requirement be met. If there is any
doubt, have the electrical system of the house checked by a qualified
electrician. Temporary or permanent operation on an autonomous power supply
system or a power supply system that is not synchronized with the grid power
supply (e.g., island networks, back-up systems) is possible. A prerequisite
for operation is that the power supply system complies with national and local
codes. The function and operation of the protective measures provided in the
domestic electrical installation and in this Miele product must also be
maintained in isolated operation or in operation that is not synchronized with
the grid power supply, or these measures must be replaced by equivalent
measures in the installation. To avoid damaging the ventilation hood, make
sure that the connection data (voltage and frequency) on the data plate
correspond to the building’s power supply before connecting the appliance. If
in doubt, consult a qualified electrician. Do not use a power bar or extension
cord to connect the ventilation hood to electricity. These are a fire hazard
and do not guarantee the required level of appliance safety. To ensure safe
operation, only use the ventilation hood after it has been properly installed.
This ventilation hood may not be used in non-stationary locations (e.g. on a
ship). Adequate ventilation must be provided when the hood is operated
simultaneously with devices that burn gas or other fuels.
6
IMPORTANT SAFETY INSTRUCTIONS
Only open the housing as described in the enclosed “Installation diagram” and
in the “Cleaning and care” section of this manual. Under no circumstances
should any other parts of the housing be opened. Tampering with electrical
connections or components and mechanical parts is highly dangerous to the user
and can cause operation faults. If the power cord is damaged, it must only be
replaced by a qualified service technician. During installation, maintenance,
and repair work, the ventilation hood must be disconnected from the electrical
supply. It is only completely isolated from the electricity supply if one of
the following applies: – The circuit breakers on the electrical service panel
are tripped. – The screw-type fuses on the electrical service panel have been
removed. – The power cord (if present) has been unplugged from the socket
(pull the plug not the cord). Correct use WARNING: TO REDUCE THE RISK OF A
COOKTOP GREASE FIRE: – a) Never leave surface units unattended at high
settings. Boilovers
cause smoking and greasy spillovers may ignite. Heat oils slowly on low or
medium settings. – b) Always turn the hood on when cooking at a high heat. –
c) Clean the ventilation hood frequently. Grease should not be allowed to
accumulate on the fan or filter. – d) Use the proper pan size. Always use
cookware appropriate for the size of the cooking area.
7
IMPORTANT SAFETY INSTRUCTIONS
Open flames are a fire hazard. The use of an open flame under the ventilation
hood is not permitted. To avoid the danger of fire, do not flambé or grill
over an open flame. When switched on, the ventilation hood could draw flames
into the filter. Fat deposits could ignite, presenting a fire hazard. WARNING:
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE,
OBSERVE THE FOLLOWING: – a) SMOTHER FLAMES with a close fitting lid, cookie
sheet, or
metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. – b)
NEVER PICK UP A FLAMING PAN – You may be burned. – c) DO NOT USE WATER,
including wet dishcloths or towels – a violent steam explosion will result. –
d) Use a fire extinguisher ONLY if:
1) You have a class ABC extinguisher, and you know how to operate it. 2)
The fire is small and contained in the area where it started. 3) The fire
department is being called. 4) You can fight the fire with your back to an
exit.
Based on “Kitchen Fire Safety Tips” published by NFPA. The ventilation hood may become damaged if exposed to excessive heat from a gas cooktop. – When using the ventilation hood over a gas cooktop, ensure that
any burners in use are always covered by cookware. Turn burners off when
removing the cookware, even if doing so for just a short time. – Select
cookware that is suitable for the size of the burner. – Adjust the flame so
that it never extends up the sides of the cookware. – Avoid overheating the
cookware (e.g., when cooking with a wok).
8
IMPORTANT SAFETY INSTRUCTIONS Always turn the ventilation hood on whenever a
burner is in use to
prevent damage from condensation. Overheated oil and fat can ignite, causing
fire damage to the ventilation hood. Do not leave cookware, pans, and deep-fat
fryers unattended when cooking with oil or fat. Similarly, never leave an open
flame unattended when grilling. Fat and debris deposits impair the proper
functioning of the ventilation hood. To ensure that cooking vapors are
properly cleaned, never use the ventilation hood without the grease filters in
place. Please note that the heat rising from the stovetop during cooking can
cause the ventilation hood to become very hot. Do not touch the housing or the
grease filters until the ventilation hood has cooled down.
9
IMPORTANT SAFETY INSTRUCTIONS
Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and
electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards, including
fire-rated construction. – b) Sufficient air is needed for combustion and
exhausting of gases through the flue (chimney of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire Protection
Association (NFPA) and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities. – c) When
cutting or drilling into the wall or ceiling, do not damage electrical wiring
and other hidden utilities. – d) Ducted hoods must always be vented to the
outdoors. – e) Do not use this hood with any solid-state speed control device.
To determine whether a ventilation hood may be operated above your cooking
appliance, please refer to the information provided by the appliance’s
manufacturer. Safety regulations prohibit the installation of a ventilation
hood over solid fuel stoves. An insufficient safety distance between the
cooktop and the ventilation hood can result in damage to the ventilation hood.
The minimum safety distances between the top of the cooktop and the bottom of
the ventilation hood given in the “Installation” section of this manual must
be observed, unless the cooktop manufacturer states that a greater safety
distance is required. If more than one cooking appliance is installed beneath
the ventilation hood, and they have different minimum safety distances to the
ventilation hood, select the greater distance.
10
IMPORTANT SAFETY INSTRUCTIONS
The information provided in “Installation” must be observed when installing
the ventilation hood. Components can have sharp edges which may cause injury.
Wear gloves to protect your hands. When installing the exhaust duct, only use
pipes or tubes made of non-flammable material. These can be obtained from your
Miele dealer or from Miele Technical Service. Always observe local building
code requirements when selecting duct material. Exhaust air should not be
vented into a chimney or vent flue which is otherwise in use and should not be
channeled into ducting which ventilates rooms with fuel-burning installations.
If exhaust air is to be extracted into a chimney or ventilation duct no longer
used for other purposes, seek professional advice. WARNING: TO REDUCE THE RISK
OF FIRE USE ONLY METAL DUCTWORK. Cleaning and maintenance There is a risk of
fire if cleaning is not completed according to the instructions in this
manual. Never use a steam cleaner to clean the ventilation hood. The steam can
reach the electrical components and cause a short circuit. Accessories and
parts Use only genuine original Miele parts. If parts or accessories from
other manufacturers are used, the warranty may become void. Defective
components should be replaced by Miele original parts only. Only with these
parts can safety of the appliance be assured as intended by the manufacturer.
11
IMPORTANT SAFETY INSTRUCTIONS Miele will guarantee to supply functional parts
for a minimum of
10 years and up to 15 years following the discontinuation of your ventilation
unit. FCC Declaration of Conformity These devices comply with FCC Rules Part
15. This equipment has been tested and found to be in compliance with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules of
Operation and is subject to the following conditions: These devices may not
cause harmful interference. These devices must accept any interference
received, including interference that may cause undesired operation. FCC
Radiation Exposure Statement This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance 8″ (20 cm) between the
radiator and your body. Industry Canada Statement This digital apparatus does
not exceed the Class B limits for Radio Noise Emissions from digital apparatus
set out in the Radio Interference Regulations of the Canadian Department of
Communications. Complies with Canadian ICES-003 Class B specifications.
12
Disposal of the packing material
The cardboard box and packing materials protect the appliance during shipping.
They have been designed to be biodegradable and recyclable. Ensure that any
plastic wrappings, bags, etc. are disposed of safely and kept out of the reach
of children. Danger of suffocation!
Caring for the environment
Disposal of your old appliance
Electrical and electronic appliances contain valuable materials. They also
contain certain substances, compounds and components which were essential for
the proper functioning and safe use of the equipment. Handling these materials
improperly by disposing of them in your household waste can be harmful to your
health and the environment. Therefore, please do not dispose of your old
appliance with regular household waste and follow local regulations on proper
disposal.
Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed. Please ensure that your old appliance is kept away from children until removal. Observe safety requirements for appliances that may tip over or pose an entrapment hazard.
13
Guide to the ventilation hood
14
Guide to the ventilation hood
a Telescopic extension piece b Duct cover c Canopy d Controls e Grease filter
f Recirculation vents
Only for recirculation mode g Overhead lighting h Charcoal filters
Optional accessories for recirculation mode i Sensor control for turning the
blower on and off j Sensor control for switching the lighting on and off and
for dimming the lighting k Sensor controls for setting the blower power l
Sensor control for the delayed shutdown function m Sensor control for the
grease filter saturation indicator n Sensor control for the charcoal filter
saturation indicator
15
Description of functions
The following functions are available on your ventilation hood, depending on
the model:
Extraction mode
Recirculation mode
The recirculation mode requires a recirculation kit and OdorFree Charcoal
Filter (available as optional accessories, see “Technical Data” for more
information)
The air is drawn in and cleaned by the grease filters and directed outside.
The air is drawn in and first cleaned by the grease filters and then by an OdorFree Charcoal Filter. The cleaned air is then recirculated back into the kitchen.
16
Before using for the first time
Selecting extraction mode or recirculation mode
The ventilation hood can be operated with either extraction mode or
recirculation mode. The power of the blower is adapted to suit the selected
mode of operation. The ventilation hood is set up at the factory for
recirculation mode. It has to be reset for extraction mode. To reset it for
extraction mode, the filter saturation indicator for the charcoal filter(s)
has to be deactivated. Switch off the blower and the lighting. Touch the
delayed shutdown
control and the charcoal filter control at the same time. The charcoal filter
symbol and one of the blower power level indicators will flash. Touch the B
control. Confirm your choice by touching the charcoal filter control . All the
indicator lights will go out. Extraction mode has now been set. If the new
setting is not confirmed within 4 minutes, the ventilation hood will revert to
the previous setting.
Setting up Miele@home
Required: – a WiFi network – the Miele app – a Miele user account. You can
create a user account via the Miele app.
Your ventilation hood is equipped with an integrated WiFi module. Connect the
ventilation hood to your household WiFi network. You will then be able to
operate the ventilation hood via the Miele app. If your Miele cooktop is
connected to a home WiFi network, you can control the ventilation hood
automatically via the Con@ctivity function.
Before installing the ventilation hood in its final location, ensure that the
signal of your WiFi network is strong enough.
Please note that you cannot set up a WiFi connection at the same time as a
wireless connection (Con@activity 2.0, remote control). You can connect to the
household WiFi network via the Miele app or via WPS.
17
Before using for the first time
Miele App The Miele App is available to download free of charge from the Apple App Store® or from the Google Play StoreTM.
Connecting via the app The Miele app can be used to connect to your network.
Install the Miele app on your mobile
device. To log in you will need: 1. your WiFi network password 2. your
ventilation hood password
The password for your ventilation hood consists of the last 9 digits of the
serial number. This can be found on the appliance’s data tag. The data plate
is visible once you have removed the grease filter.
Start signing the appliance on in the app. Follow the signing in instructions.
If requested to activate WiFi on the ventilation hood, proceed as follows:
18
Switch the ventilation hood off. Press and hold the B control.
Before using for the first time
Connecting via WPS Your WiFi router must support WPS (WiFi Protected Setup).
Switch the ventilation hood off.
Touch the lighting control at the same time.
Press and hold the B control.
2 will light up constantly, 3 will flash on and off. The ventilation hood will
be ready for connection in the next 2 minutes.
Follow the instructions in the app.
Touch the lighting control at the same time.
2 will light up constantly, 3 will flash on and off. The WiFi connection must
be started on the ventilation hood at the same time as on the WiFi router.
When successfully connected, 2 and 3 will light up constantly.
Press the B control on the ventilation hood after a few seconds.
Quit connection mode on the ventilation hood by touching the delayed shutdown
control .
The ventilation hood can now be operated via the app.
After a short while, 2 will light up constantly, and 3 and B will flash on and off. The ventilation hood is ready for connection in the next two minutes.
19
Before using for the first time
Start the WiFi connection on your WiFi router.
Signing out of WiFi (reset to factory settings) To set up a new WiFi connection, the existing WiFi connection must be disconnected. Switch the ventilation hood off.
When successfully connected, 2 and 3 will light up constantly.
Press and hold the 1 control.
Quit connection mode on the ventilation hood by touching the delayed shutdown
control .
The ventilation hood can now be operated via the app. If the connection fails,
you have probably not connected WPS to your router quickly enough. Repeat the
steps above. Tip: If your WiFi router does not support WPS, please connect via
the Miele app.
Touch the lighting control at the same time.
With an existing WiFi connection, 2 and 3 will light up constantly. The
ventilation hood is ready for disconnection during the next two minutes.
20
Before using for the first time
Touch the 1 control. 2 will light up constantly, 3 will flash on and off.
After a few seconds, 2 and 3 will flash on and off. The connection has now
been disconnected.
Quit disconnection mode on the ventilation hood by touching the delayed
shutdown control .
The WiFi connection has now been disconnected. A new connection can now be set
up.
Setting up Con@ctivity
Con@ctivity is the direct communication system between an induction Miele
cooktop and a Miele ventilation hood. It enables the ventilation hood to
operate automatically depending on the operational state of a Miele cooktop
with onset controls. – When a burner is turned on, the
overhead lighting on the hood turns on automatically. After a brief delay, the
ventilation hood blower also comes on. – The ventilation hood selects the
power setting automatically during cooking. The power level selected by the
ventilation hood depends on the number of cooking zones being used and their
power levels. – After switching the cooktop off, the blower and the overhead
lighting will switch off automatically after a specified period of time.
Detailed information about this function can be found under “Operation”.
21
Before using for the first time
This ventilation hood can be operated with the Con@ctivity function via a WiFi
connection (Con@ctivity 3.0) or via a wireless connection (Con@ctivity 2.0).
Con@ctivity via the home WiFi network (Con@ctivity 3.0) Prerequisite:
– Home WiFi network – WiFi-enabled Miele cooktop Connect the ventilation hood
and cooktop to your home WiFi network (see “Setting up Miele@home”). The
Con@ctivity function will be activated automatically.
Con@ctivity via a direct WiFi connection (Con@ctivity 3.0) Prerequisite:
– WiFi enabled Miele cooktop If you do not have a home network, you can
establish a direct connection between the cooktop and the ventilation hood.
Switch the ventilation hood off.
Press and hold the B control.
Touch the 1 control at the same time.
2 will light up constantly, 3 will flash on and off. The ventilation hood is ready for connection in the next two minutes.
22
Before using for the first time
Start WiFi connection on the cooktop. For more details, see the cooktop
operating instructions.
When successfully connected, 2 and 3 will light up constantly.
Con@ctivity with direct wireless connection (Con@ctivity 2.0) Required:
– Con@ctivity 2.0 enabled Miele induction cooktop
Quit connection mode on the ventilation hood by touching the delayed shutdown
control .
Con@ctivity has now been activated. With a direct WiFi connection, it is not
possible to connect the cooktop and the ventilation hood to a home network.
Should this be required at a later date, the WiFi connection between the
cooktop and the ventilation hood must be disconnected (see “Signing out of
WiFi”). Reattempting the connection
If it is not possible to connect, 2 and 3 flash or the ventilation hood
cancels the process. Disconnect the connection to the
ventilation hood (see “Signing out of WiFi”) and to the cooktop. Attempt to
make the connection again.
This ventilation hood is supplied with a Con@ctivity 2.0 wireless stick . The
wireless stick can only be used with cooktops that are fitted with a slot for
the wireless stick to operate the Con@ctivity function. Check the installation
instructions for
the Con@ctivity 2.0 stick to ensure that it is compatible with your cooktop.
Please note that you cannot set up a WiFi connection at the same time as a
wireless connection (Con@activity 2.0, remote control).
23
Before using for the first time
Installing the Con@ctivity 2.0 stick See the relevant installation
instructions provided with the Con@ctivity 2.0 stick.
Activating the wireless connection The ventilation hood and the cooktop must
be installed and operational. The wireless connection must be activated on the
ventilation hood and the cooktop at the same time. Activation on the
ventilation hood is described below. Activation on the cooktop is described in
the relevant operating and installation instructions. Please refer to the
operating instructions before starting. Activate the ventilation hood first,
then the cooktop.
Activating the ventilation hood The cooktop and ventilation hood
must be switched off.
Touch the delayed shutdown control for approx. 10 seconds until 1 lights up.
Then touch in turn:
– the 1 control,
– then the B control,
– then the lighting control . The ventilation hood is now in signing on/off mode.
If a wireless connection has not yet been established, 2 and 3 will flash at the same time. If a wireless connection has already been established, 2 and 3 will light up constantly (Con@ctivity 2.0 is already activated or a remote control is signed on).
24
Before using for the first time
Touch the B control to activate Con@ctivity 2.0.
2 will light up constantly, 3 will flash on and off.
After a few seconds, 2 and 3 will light up constantly, B will flash on and
off. The search for a wireless connection will start. Activating the cooktop
While the ventilation hood is searching for a signal, start activating the
cooktop. For more details, see the cooktop operating instructions.
When the cooktop registers that a connection has been established, exit
activation on the cooktop.
Finishing activation on the ventilation hood
When successfully connected, B will go out, and 2 and 3 will light up
constantly.
Confirm activation with the delayed shutdown control . All the indicator
lights will go out.
The Con@ctivity function is now ready for use. If you do not confirm within 4
minutes, activation will be canceled. You only need to carry out the
activation procedure once. If the appliances are disconnected from the
electricity supply, for example during a loss of power, they will still remain
activated.
25
Before using for the first time
Activation failed If a wireless connection cannot be established despite
activation of the Con@ctivity function on the ventilation hood and cooktop,
the function must first be deactivated and then reactivated on both
appliances. Deactivating the wireless connection The cooktop and ventilation
hood
must be switched off.
Touch the delayed shutdown control for approx. 10 seconds until 1 lights up.
Then touch in turn:
– the 1 control,
– then the B control,
Touch the 1 control to deactivate Con@ctivity 2.0.
2 will light up constantly, 3 will flash on and off.
After a few seconds, 2 and 3 will start flashing on and off. The wireless
connection has now been deactivated. To deactivate the cooktop, please
refer to the corresponding operating instructions. Please bear in mind that
disabling the connection will also disable any remote control function being
used. The remote control must then be reactivated.
– then the lighting control . The ventilation hood is now in signing on/off mode.
If a wireless connection has already been established, 2 and 3 will light up constantly.
26
Operation (Automatic mode)
When Con@ctivity is active, the ventilation hood always operates in automatic
mode (see “Before using for the first time Setting up Con@ctivity”). If you
wish to operate the ventilation hood manually; see “Operation (Manual mode)
Cooking without Con@ctivity”.
Cooking with Con@ctivity (Automatic mode)
Turn on a burner to the desired power setting.
The overhead lighting will come on. After a few seconds, the blower will come
on, briefly operating at power level 2 before immediately switching to level
- The ventilation hood selects the power level automatically during cooking. This level is determined by the total output of the cooktop, i.e., the number of burners in operation and the power levels selected. If you select a higher power level on the cooktop or switch on multiple burners, the ventilation hood will switch to a higher blower level. If you select a lower power level on the cooktop or turn off a burner, the ventilation hood will accordingly switch to a lower blower level.
Examples for power levels 1 to B
Reaction time
Changing the power setting on the cooktop does not lead to an immediate
increase or decrease in cooking vapors. For this reason, the hood reacts with
a slight delay. Delays can also result from the fact that the cooktop
transmits the information to the hood in intervals. The reaction time can vary
from a few seconds to a couple of minutes.
Cooking process
For example, you switch on a burner at the highest power level to heat
cookware for frying. After approx. 10 seconds to 4 minutes, you then reduce
the power level (60 seconds to 5 minutes for a HiLight cooktop).
The ventilation hood recognizes a cooking process. The ventilation hood turns
itself on and when the cooktop power level has been reduced, the ventilation
hood switches to power level 3 and remains at that level for approx. 5
minutes. After this, the blower level is once again determined by the
Con@ctivity function. You can also manually select a different blower level
before then.
27
Operation (Automatic mode)
Switching off
Turn off all burners. Over the next few minutes, the ventilation hood blower
setting will decrease one level at a time until the hood eventually turns off.
This helps to neutralize any lingering vapors and odors in the air. – From the
Booster setting, the blower
switches immediately to level 3. – From level 3, it will switch to level 2
after approx. 1 minute. – From level 2, it will switch to level 1
after 2 minutes. – After 2 minutes at level 1, the blower
automatically turns off. – After another 30 seconds, the
overhead lighting turns off. The cooking process is then finished.
Temporarily exiting Automatic mode
To temporarily exit Automatic mode when cooking: Manually select a different
blower
level; or Manually turn the ventilation hood off;
or Activate the delayed shutdown
function on the ventilation hood. The blower will switch itself off after the
selected run-on time, and the lighting will remain on. The ventilation hood
functions are now operated manually (see “Operation (Manual mode)”).
Resuming Automatic mode The ventilation hood resumes Automatic mode: – If the
ventilation hood has not been
used for a period of approx. 5 minutes after the manual selection of a blower
level; or – If the manually selected blower level once again matches the
automatic setting; or – The ventilation hood blower and the cooktop have been
switched off for at least 30 seconds. Automatic mode will resume next time the
cooktop is switched on. You can also operate the ventilation hood manually for
a complete cooking process. To do so, switch the ventilation hood blower on
before the cooktop. If the ventilation hood and the cooktop have been switched
off for at least 30 seconds after cooking, Automatic mode will resume next
time the cooktop is switched on.
28
Operation (Manual mode)
Cooking without Con@ctivity (Manual mode)
The ventilation hood can be operated manually if: – The Con@ctivity function
is not
activated. – You have temporarily deactivated the
Con@ctivity function (see “Operation (Automatic mode) Temporarily exiting
Automatic mode”).
Turning on the blower
Switch the blower on as soon as you start cooking. This is to ensure that
vapors are captured right from the start. Touch the On/Off control . The
blower switches on at power level 2.
Selecting the power level
Power levels 1 to 3 are available for light to heavy cooking vapors and odors.
For strong vapors and odors that are temporarily produced when cooking, e.g.,
during searing, select the B booster level. Select the power level required by
tapping a button from 1 to B.
Reducing power down from the Booster setting If power management is activated
(default setting), the blower automatically switches back to level 3 after 5
minutes.
Selecting the delayed shutdown time
It is advisable to run the blower for a few minutes after cooking has
finished. This helps to neutralize any lingering vapors and odors in the air.
It also reduces the risk of residues accumulating in the ventilation hood and
any resultant odors. The delayed shutdown function enables the blower to
continue running for a pre-determined time before switching itself off
automatically. After you have finished cooking,
touch the delayed shutdown control . – Once: blower switches off after 5
minutes (5 lights up). – Twice: blower switches off after 15 minutes ( 15
lights up). – If you touch the delayed shutdown control again, the blower will
remain switched on ( will go out).
Turning off the blower
Press the On/Off control to turn the blower off.
Dimming/switching the overhead lighting on/off
The overhead lighting can be switched on and off and dimmed independently of
the blower. Touch the lighting control briefly to
switch it on or off. The lighting will switch on at maximum brightness.
29
Operation (Manual mode)
With the lighting switched on, press and hold the lighting control . The
brightness will gradually dim until you release the control.
To increase the brightness, press and hold the lighting control again until
the desired level has been reached and then release it.
Power management
The ventilation hood is equipped with a power management system. Power
management helps to save energy. It ensures that the blower power level is
reduced automatically and that the lighting is switched off. – If the booster
level is selected, the
blower automatically switches to level 3 after 5 minutes. – If the blower is
set to level 3, 2, or 1, it switches back one blower setting after 2 hours and
then in 30-minute intervals until the blower eventually switches off. – The
overhead lighting will switch off automatically after 12 hours. You can
deactivate power management. Keep in mind that this may increase energy
consumption.
Activating/deactivating power management Switch off the blower and the
lighting. Touch the delayed shutdown
control for approx. 10 seconds, until 1 lights up in the power level display.
Then press in order:
– the lighting control , – the 1 control, and then – the lighting control .
When power management is turned on, the 1 and B indicators will be
continuously lit. When it is turned off, the 1 and B indicators will flash.
Touch the 1 control to deactivate
power management. The 1 and B indicators will flash. Touch the B control to
activate power
management. The 1 and B indicators will be continuously lit. Confirm the
setting by pressing the
delayed shutdown control . All the indicator lights will go out. If you do not
confirm the new setting within 4 minutes, the ventilation hood will revert to
the previous setting.
Safety shut-off
If power management has been deactivated, the ventilation hood will switch
itself off automatically after 12 hours if it has been left on (blower and
overhead lighting). To switch it back on, press the On/
Off control or the lighting control .
30
Operation (Automatic and Manual modes)
Filter saturation indicator
The ventilation hood registers the length of time it has been operated. The
filter saturation indicators show when the filters need to be cleaned or
changed by lighting up the grease filter symbol or charcoal filter symbol .
Additional information on cleaning and changing the filters and resetting the
filter saturation indicators can be found under “Cleaning and care”.
Adjusting the grease filter filter saturation indicator The filter saturation
indicator can be set to suit the customer’s cooking habits. The factory
default setting is a cleaning interval of 30 hours. – Select a shorter
interval of 20 hours if
food is fried regularly. – A shorter cleaning interval is also
recommended if the customer only cooks occasionally. This will prevent grease
buildup from hardening and making cleaning more difficult. – Select a longer
cleaning interval of 40 or 50 hours if the customer uses very little fat when
cooking.
Switch off the blower and the lighting. Touch the delayed shutdown
control and the grease filter control at the same time. The grease filter
symbol and one of the blower power level indicators will flash. The indicators
1 to B show the current time setting: 1……………………………………….. 20 hours
2……………………………………….. 30 hours 3……………………………………….. 40 hours B ………………………………………. 50
hours Touch the relevant control to select the duration required. Confirm your
choice by touching the grease filter control . All the indicator lights will
go out. If the new setting is not confirmed within 4 minutes, the ventilation
hood will revert to the previous setting.
31
Operation (Automatic and Manual modes)
Adjusting or deactivating the filter saturation indicator for the charcoal
filter The charcoal filter is needed for recirculation mode. The filter
saturation indicator can be set to suit the customer’s cooking habits. It has
to be deactivated for vented mode. The factory default setting is an interval
of 180 hours. Switch off the blower and the lighting. Touch the delayed
shutdown
control and the charcoal filter control at the same time. The charcoal filter
symbol and one of the blower power level indicators will flash. The indicators
1 to B show the current time setting: 1……………………………………… 120 hours
2……………………………………… 180 hours 3……………………………………… 240 hours B …………………………………..
Deactivated Touch the relevant control to select the duration required.
Confirm your choice by touching the charcoal filter control . All the
indicator lights will go out. If the new setting is not confirmed within 4
minutes, the ventilation hood will revert to the previous setting.
Checking the filter saturation indicator Before the set operating time has run
out, you can check what percentage of the time has elapsed. Press the On/Off
control to turn
the blower on. Press and hold the grease filter
control or the charcoal filter control . One or more of the power level
indicators will flash. The number of flashing indicators shows the elapsed
operating time as a percentage. 1 …………………………………………… 25 % 1 and 2
…………………………………. 50 % 1 to 3 ……………………………………. 75 % 1 to B ………………………………….. 100 %
The elapsed operating time remains stored in the memory when the ventilation
hood is turned off or in the event of an interruption to the power supply.
32
Energy-saving tips
This hood operates in a very efficient and energy-saving manner. The following
will help you to save even more energy when using it: – Ensure that there is
sufficient
ventilation in the kitchen when cooking. If there is insufficient air flow
during extraction mode, the hood cannot operate efficiently, causing increased
operating noise levels. – Always cook with the lowest possible setting. This
produces fewer cooking vapors so that you can use a lower hood power level and
therefore benefit from reduced energy consumption. – Clean or change the
filters at regular intervals. Heavily soiled filters reduce performance,
increase the risk of fire and are unhygienic.
– Use the Con@ctivity function. The ventilation hood will switch on and off
automatically. The ventilation hood will select the optimum power level for
the cooking you are doing, which ensures low energy consumption.
– If you are operating the ventilation hood manually, please note the
following: Check the power level selected on the ventilation hood. A low
power level is usually sufficient. Only use the Booster setting when
necessary. When a large volume of cooking vapors are being produced, switch
to a high power level in good time. This is more efficient than operating the
hood for longer to try to capture cooking vapors that have already been
distributed throughout the kitchen. Make sure that you switch off the hood
after use. If cooking vapors and odors still need to be removed from the
kitchen air after cooking, use the delayed shutdown function. The blower will
switch off automatically after the selected delayed shutdown time.
33
Cleaning and care
Before proceeding with any
maintenance or cleaning task, the ventilation hood must be disconnected from
the power supply, see “IMPORTANT SAFETY INSTRUCTIONS”.
Stainless steel housing
General information
The surfaces and control buttons
are susceptible to scratching and chipping. Observe the following cleaning
instructions.
Clean all surfaces and control buttons using warm water and liquid dish soap.
Apply with a sponge cloth.
After cleaning, dry the surfaces with a soft cloth.
Avoid the following: – Cleaners containing soda, acid or
chloride, or cleaners containing solvents – Abrasive cleaners such as scouring
powder, scouring liquid, abrasive sponges such as pot scourers, or used
sponges that still contain residues from abrasive cleaners
Important information for appliances with stainless steel surfaces Stainless
steel surfaces can be cleaned with a non-abrasive cleaning agent designed
specifically for use on stainless steel. To prevent the surfaces from quickly
becoming dirty again, we recommend treating them with a stainless steel care
product (available from Miele). Important information for appliances with
lacquered housing Minor scratches on the surface are inevitable when cleaning
the casing; they may be visible depending on the lighting in the kitchen.
Special instructions for glass surfaces Glass surfaces can be cleaned using
a cleaner specifically for use on glass.
34
Cleaning and care
Grease filters
Risk of fire
Oversaturated grease filters are a fire hazard. Clean the grease filters at
regular intervals.
The re-usable metal grease filters in the appliance remove solid particles
(grease, dust, etc.) from the kitchen vapors, preventing soiling of the
ventilation hood. The grease filters must be cleaned at regular intervals.
Removing the grease filters
When handling the grease filter,
be careful not to drop it. This can result in damage to the filter and the
cooktop below. Make sure you hold the filter securely at all times when
handling it.
Heavily soiled grease filters hinder air extraction and will lead to increased
levels of soiling in the ventilation hood and in the kitchen.
Cleaning intervals Accumulated grease solidifies over a longer period of time
and makes cleaning more difficult. The grease filters should therefore be
cleaned every 3 to 4 weeks. The filter saturation indicator reminds you to
regularly clean the grease filters by illuminating the grease filter symbol .
You can adjust the interval for the filter saturation indicator to match your
cooking habits (see “Operation (Automatic and Manual modes)”).
To remove a grease filter, release the locking clip. Then, open the filter to
a 45° angle, unhook it, and remove it from the hood.
Cleaning the grease filters by hand Clean the filters with a soft nylon
brush in a mild solution of hot water and dish soap. Do not use undiluted dish
soap.
35
Cleaning and care
Unsuitable cleaning agents Unsuitable cleaners can cause damage to the filter
surfaces if used regularly. Do not use any of the following: – Lime removers –
Abrasive powders or abrasive liquids – Aggressive all-purpose cleaners and
degreaser sprays – Oven sprays
Cleaning the grease filters in a dishwasher Place the grease filters upright
or
slightly inclined in the lower basket. Ensure the spray arm is not obstructed.
Use a commonly available household dishwashing detergent. In a Miele
dishwasher use the “Normal” program.
Depending on the detergent used, cleaning the filters in a dishwasher may
cause the inside filter surfaces to become discolored. However, this will not
affect the functioning of the grease filters in any way.
After cleaning After cleaning, leave the filters on an
absorbent surface to dry. When removing the filters for
cleaning, also clean off any accessible oil or fat buildup from the housing.
Doing so will prevent a fire hazard. Reinsert the grease filters. When
inserting the grease filters, make sure that the locking clip is facing
outward. 36
If a grease filter is inadvertently fitted upside down, insert a small
screwdriver blade into the slit to disengage the clip.
Resetting the filter saturation indicator for the grease filters Once cleaning
is complete, the filter saturation indicator must be reset. While the blower
is turned on, touch
the grease filter control for approx. 3 seconds, until only the 1 is flashing.
The grease filter symbol goes out. When cleaning the grease filters before the
full operating time has elapsed: Touch the grease filter control for approx. 6
seconds, until only the 1 is flashing.
Replacing the grease filter Regular usage and cleaning can cause the filter
surfaces to become worn. If you identify any damage, replace the grease
filters. Grease filters are available to order via Miele Customer Service (see
end of these operating instructions for contact details) or from your Miele
dealer.
Cleaning and care
OdorFree Charcoal Filter
With recirculation mode, a charcoal filter must be fitted in addition to the
grease filters. The charcoal filter is designed to absorb cooking odors. The
charcoal filter is fitted in the canopy above the grease filters. How to
install/replace a charcoal filter Remove the grease filters before
fitting or replacing a charcoal filter. Take the charcoal filter out of its
packaging.
Slide the filter into the back of the intake frame, then push the front of the
filter up into the frame.
Reinsert the grease filters.
When to change the OdorFree Charcoal Filter Replace the charcoal filter when
it no
longer absorbs kitchen odors effectively. It should be replaced at least every
6 months. The filter saturation indicator reminds you to regularly replace the
charcoal filter by illuminating the charcoal filter symbol .
Resetting the filter saturation indicator for the charcoal filters After
changing the charcoal filters, the filter saturation indicator must be reset.
Touch the charcoal filter control for
approx. 3 seconds with the blower switched on until only the indicator light
for level 1 is flashing. The charcoal filter symbol will go out. If you want
to replace the charcoal filter before the full operating time elapses: Touch
the charcoal filter control for approx. 6 seconds until only the indicator
light for level 1 is flashing.
Disposing of charcoal filters Used charcoal filters can be disposed
of with normal household waste. Charcoal filters are available to order via
the Miele Web Store (see end of this booklet for contact details), or from
your Miele dealer. The charcoal filters are listed under “Technical data” at
the back of this booklet.
37
INSTALLATION
Installation
Before installation Before installation, it is important
to read the information contained in this chapter and in the “IMPORTANT SAFETY
INSTRUCTIONS” chapter.
Removing the protective film
The housing components are covered by a protective film to prevent them from
damage during transport. Please remove this film before
installing the housing components. It can be peeled off easily without any
additional tools.
Installation materials
1 non-return flap for installation in the exhaust vent on the motor (not
needed for recirculation mode)
6 screws 5 x 60 mm and 6 plugs 8 x 50 mm for securing the ventilation hood on
the wall.
The screws and plugs are
designed for use in solid walls only. Use different fasteners for other wall
construction types. Make sure that the wall can support the load.
2 M6 locknuts for mounting the appliance unit
Telescopic wall bracket for securing the ventilation system on the wall.
2 screws 3.9 x 7.5 mm for securing the duct cover
38
INSTALLATION MontagIenstallaMtioonntajMeontagMgoionterMinogntagAesmennus
Installation plan See the installation plan for details of the individual
steps involved in the installation of this appliance.
Installation
DUW20
Conversion kit for recirculation mode The conversion kit contains an exhaust
grille, hose, and hose clips (not supplied, but available as an optional
accessory. See “Technical data”).
39
INSTALLATION
Installation
Appliance dimensions
The drawing is not to scale a Extraction mode b Recirculation 40
INSTALLATION
Installation
c Air vent positioned at the top for recirculation de Installation area (only
d is required for recirculation operation). Wall or ceiling
area for the ducting cutout and for the electrical outlet. For recirculation
operation, only an electrical outlet needs to be installed. Exhaust connection
6″ (150 mm)
Distance between cooktop and ventilation hood (S)
Provided a larger distance is not given by the manufacturer of the cooktop,
follow the minimum safety distances between a cooktop and the bottom of the
hood. Please also observe the information contained in the “IMPORTANT SAFETY
INSTRUCTIONS” section.
Cooking appliance
Electric Cooktops Electric Barbeques and Fryers Multiburner Gas Cooktops
43,000 BTU/hr (12.6 kW), no burner > 15,000 BTU/hr (4.5 kW). Multiburner Gas
Cooktops 73,800 BTU/hr (21.6 kW), no burner > 16,500 BTU/hr (4.8 kW)
Multiburner Gas Cooktops > 73,800 BTU/hr (21.6 kW), or one of the burners >
16,500 BTU/hr (4.8 kW) Single Burner Gas Cooktops 20,500 BTU/hr (6 kW) Single
Burner Gas Cooktops > 20,500 BTU/hr (6 kW) 27,600 BTU/hr (8.1 kW) Single
Burner Gas Cooktops > 27,600 BTU/hr (8.1 kW)
Minimum distance S
Miele appliance
Non-Miele appliance
24″ (610 mm)
26″ (660 mm)
26″ (660 mm) 30″ (760 mm)
30″ (760 mm)
Not possible
26″ (660 mm) 30″ (760 mm) 30″ (760 mm)
Not possible
41
INSTALLATION
Installation
Installation recommendations
– A distance of at least 26″ (660 mm) is recommended above electric cooktops
to provide more workspace and easier cooking under the hood.
– When selecting an installation height, always take the user height into
consideration. Users should have ample space to work comfortably on the
cooktop and reach the ventilation hood controls with ease.
– Please note that the greater the distance from the cooktop, the less
effective the hood is at drawing in the cooking vapors.
– To achieve optimum vapor extraction, the hood must be centered over the
cooktop, not to the side.
– The cooktop should be no wider than the hood. Preferably, it should be
narrower for better extraction.
– The mounting area must be easily accessible. The ventilation hood should be
easy to reach and disassemble in case a service call is necessary. This should
be taken into consideration when planning the position of cabinetry, shelves,
ceilings or decorative elements in the vicinity of the ventilation hood.
Drilling diagram for wall mounting
Please follow the directions given in the installation instructions supplied
for drilling.
When installing a custom back wall with pre-drilled holes, please refer to the
drilling distances in the drawing above (screws ³/” (5 mm)).
42
INSTALLATION
Plywood backing
The majority of the weight of the installed ventilation system will be
supported by the lower retaining plate. It must be firmly attached to the stud
framing behind the drywall. If studs are not available in the required
locations, a plywood backing (min. ½” (13 mm) thick) spanning at least two
studs must be installed. Failure to adequately support the weight as stated
may result in the ventilation system falling off the wall, causing personal
injury and property damage.
If plywood backing is not needed, proceed to the included “Installation
diagram”.
To install a plywood backing
Installation
Make a cutting line 3″ (76 mm) above and 3″ (76 mm) below the outline of the
retaining plate.
Find the studs to the left and right of the mounting location by tapping the
wall or using a stud finder.
Mark a vertical cutting line along the center of each stud. CAUTION: When
cutting or drilling into the wall or ceiling, do not damage electrical wiring
and other hidden utilities.
Remove the drywall between the cutting lines and replace it with plywood of a
matching thickness (min. ½” (13 mm) thick). Tape the joints and refinish the
wall.
Proceed to the enclosed “Installation diagram” to complete the installation.
Determine and mark the location of the retaining plate for the canopy as outlined on the “Installation diagram”. 43
INSTALLATION
Installation
Air venting
WARNING: Danger of toxic fumes. Gas cooking appliances release carbon monoxide
that can be harmful or fatal if inhaled. To reduce the risk of fire and to
properly exhaust air, the exhaust gases extracted by the hood should be vented
outside of the building only. Do not vent exhaust air into spaces within walls
or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire,
only use metal ductwork. Please read and follow the “IMPORTANT SAFETY
INSTRUCTIONS” to reduce the risk of personal injury. Follow all local building
codes when installing the hood.
Only use smooth pipes or flexible ducting made from approved nonflammable
materials for ducting.
To achieve the most efficient air throughput with the lowest noise levels,
please note the following: – The diameter of the vent ducting
must not be smaller than the crosssection of the vent collar (see “Appliance
dimensions”). This applies in particular when using flat ducting. – The
ducting should be as short and straight as possible. – Only use wide radius
bends. – The ducting must not be kinked or compressed.
– All connections must be strong and airtight.
– If the ducting has flaps, these must be opened whenever the ventilation hood
is switched on. Any constriction of the air throughput will reduce extraction
performance and increase operating noise.
Ventilation stack
If the exhaust air is to be ducted into a flue, the ducting must be directed
in the flow direction of the flue. If the flue is used by several ventilation
units, the cross-section of the flue must be large enough. Non-return flap Use
a non-return flap in the vent
system. A non-return flap ensures that when the ventilation hood is not in
operation, the duct is closed to prevent unwanted exchange of room air and
outside air. If the exhaust is ducted through an outside wall, a Miele wall
vent or roof vent (available as an optional accessory) is recommended. Both of
these have a built-in non-return flap.
44
INSTALLATION
Installation
If the on-site vent system does not have a non-return flap, one is supplied
with the ventilation hood. The non-return flap is installed in the exhaust
socket of the fan.
Condensate If the ducting is to run through cool rooms or ceiling space, for
example, the significant variations in temperature between the different areas
can cause condensate to form. Insulate the ducting to reduce temperature
variations. If the ducting is to be laid horizontally, it must be laid with a
downwards sloping gradient of at least ³/” (1 cm) per meter. This is to ensure
that condensate cannot drain back into the ventilation hood.
Condensate traps for 5″ (125 mm) or 6″ (150 mm) diameter ducting are available
as optional accessories. When installing a condensate trap, ensure that it is
positioned vertically and as closely as possible to the ventilation hood above
the exhaust vent. The arrow on the casing indicates the direction of airflow.
Miele will not accept warranty claims for any functional defects or damage
caused by inadequate ducting.
Reducing Collar (optional accessory)
In addition to insulating the ducting, it is advisable to also install a condensate trap for collecting and evaporating any potential condensate.
If you would like to reduce the environmental impact of your ventilation
system by limiting the CFM output the Reducing Collar can be installed. It
reduces the air flow to less than 400 CFM. Check local building codes for max.
CFM requirements. Push the Reducing Collar on the
exhaust port of the blower. Push the exhaust hose over it. Secure both with a
hose clamp.
45
INSTALLATION
Installation
Electrical connection
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified
electrician in strict accordance with national regulations (for USA: ANSI-NFPA
70) and local safety regulations. Installation, repairs and other work by
unqualified persons could be dangerous. Ensure that power to the appliance is
OFF while installation or repair work is performed. Verify that the voltage,
load and circuit rating information found on the data plate (see “Technical
Service”), match the household electrical supply before installing the hood.
Use only with ventilation hood cordconnection kits that have been investigated
and found acceptable for use with this model hood. If there is any question
concerning the electrical connection of this appliance to your power supply,
please consult a licensed electrician or call Miele’s Technical Service
Department.
Grounding Instructions WARNING – Improper grounding can result in a risk of
electric shock.
This appliance must be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing a path of least
resistance. This appliance is equipped with a cord having a grounding wire
with a grounding plug. If there is any doubt, have the electrical system of
the house checked by a qualified electrician. Do not use an extension cord. If
the power supply cord is too short, have a qualified electrician install an
outlet near the appliance. The plug must be plugged into an
outlet that is properly installed and grounded. WARNING – Grounding
instructions (Canada) The grounding-type attachment plug shall be connected to
a groundingtype receptacle installed in accordance with CSA C22.1-12, Canadian
Electrical Code, Part I.
WARNING: THIS APPLIANCE MUST BE GROUNDED
46
Information to help you rectify faults yourself and about Miele spare parts
can be found at www.miele.com/ service.
Contact in the event of a fault
In the event of a fault which you cannot remedy yourself, please contact your
Miele dealer or Miele Customer Service. You can book a Miele Service Call
online at www.miele.com/service. Contact information for Miele Customer
Service can be found at the end of this document. Please quote the model
identifier and serial number of your appliance (SN) when contacting Miele
Customer Service. Both pieces of information can be found on the data plate.
Location of the data plate
The data plate is visible once you have removed the grease filters.
Appliance warranty and product registration
You can register your product and/or view the manufacturer´s warranty terms
and conditions for Miele appliances and vacuum cleaners at www.mieleusa.com.
Customer Service
47
Technical data
Blower motor Overhead lighting Total connected load Supply voltage, frequency
Fuse Power cord length Weight
WiFi module Frequency range Maximum transmission power
ZigBee® module Frequency band Maximum transmission power
Optional accessories for recirculation mode
DUW 20 conversion kit and DKF 12-900 charcoal filter
350 W 3 x 3 W
359 W 120 V AC, 60 Hz
15 A 2.5 ft (0.75 m) 57.2 lbs (26 kg)
2.4002.4835 GHz < 100 mW
2.4052.48 GHz < 10 mW
WiFi module EK037 FCC ID: 2ACUWEK037 IC: 5669C-EK037 ZigBee® module EK038 FCC ID: 2ACUWEK038 IC: 5669C-EK038 This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
48
Please have the model and serial number of your appliance available when
contacting Customer Service.
U.S.A.
Miele, Inc.
National Headquarters 9 Independence Way Princeton, NJ 08540 www.mieleusa.com
Customer Support Phone: 888-99-MIELE (64353) info@mieleusa.com
International Headquarters Miele & Cie. KG Carl-Miele-Straße 29 33332
Gütersloh Germany
Canada
Importer Miele Limited
Headquarters and Miele Centre 161 Four Valley Drive Vaughan, ON L4K 4V8
www.miele.ca
Customer Care Centre Phone: 1-800-565-6435
905-532-2272 customercare@miele.ca
DA 6698 W en-US
M.-Nr. 12 253 910 / 01
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>