BITMAIN S9 Server Installation Guide
- May 15, 2024
- BITMAIN
Table of Contents
BITMAIN S9 Server
Product Information
Specifications
Feature | Description |
---|---|
Hash Rate | 5%Th/s |
Power Consumption | 1176W+10% to 1323W+10% |
Input Voltage | 11.60~13.00V |
Efficiency | 0098J/GH+10% |
Dimensions | 350mm x 135mm x 158mm |
Product Usage Instructions
-
Connecting the Power Supply
Ten PCI-e connectors are located at the top of the S9 server for connecting the PSU. Follow these steps: -
Connect PSU power cable connectors to each of the nine PCI-e connectors on the top of the S9 server, ensuring each hash board is powered by the same PSU.
-
Connect a PSU power cable connector to the S9 PCI-e connector on the controller.
-
Connect the network cable to the ETH port.
-
To power up your S9 server, connect the PSUs to the power wall outlet.
-
Setting Up the Server
The S9 server is pre-tested and configured for easy setup.
Follow these steps: -
Ensure you have your own ATX power supply.
-
Refer to the S9 Server Components diagram to identify the main components.
-
Configuring the Server
After setting up the server, configure it as per your requirements. Refer to the user manual for detailed configuration steps. -
Monitoring Your Server
Monitor the performance and status of your server regularly to ensure optimal operation. -
Administering Your Server
Perform administrative tasks such as checking firmware versions, upgrading the system, modifying passwords, and restoring initial settings as needed.
FAQ
- Q: What should I do if my S9 server does not power on?
A: Check the power supply connections and ensure all components are properly connected. If issues persist, contact customer support for assistance.
© Copyright Bitmain Technologies Holding Company 2007 – 2022. All rights reserved. Bitmain Cayman (hereinafter referred to as ‘Bitmain’) reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to Bitmain’s terms and conditions of sale supplied at the time of order acknowledgment.
Bitmain warrants the performance of its products to the specifications applicable at the time of sale under Bitmain’s standard warranty. Testing and other quality control techniques are used to the extent Bitmain deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Bitmain assumes no liability for third‐party application assistance. Customers are responsible for their products and applications using Bitmain components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.
Bitmain does not warrant or represent that any license, either express or implied, is granted under any Bitmain patent right, copyright or other Bitmain intellectual property right relating to any combination, machine, or process in which Bitmain products or services are used. Information published by Bitmain regarding third‐party products or services does not constitute a license from Bitmain to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Bitmain under the patents or other intellectual property of Bitmain. Resale of Bitmain products or services with statements different from or beyond the parameters stated by Bitmain for that product or service voids all express and implied warranties for the associated Bitmain product or service and is an unfair and deceptive business practice. Bitmain is not responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered trademarks of their respective holders. All text and figures included in this publication are the exclusive property of Bitmain, and may not be copied, reproduced, or used in any way without the express written permission of Bitmain. Information in this document is subject to change without notice and does not represent a commitment on the part of Bitmain. Although the information in this document has been carefully reviewed, Bitmain does not warrant it to be free of errors or omissions. Bitmain reserves the right to make corrections, updates, revisions or changes to the information in this document.
Bitmain
- Tel:+86‐400‐890‐8855
- www.bitmain.com.
Overview
The S9 server is Bitmain’s newest version in the S9 server series. It boasts a state‐of‐the‐art BM1387 custom‐made chip using 16nm technology. All S9 servers are tested and configured before shipping to ensure easy set-up.
You must provide your own ATX power supply.
S9 Server Components
The S9 Server main components and controller front panel are shown in the following figure:
Specifications
Feature Description
Hash Rate| 12±
5%Th/s
| 12.5±
5%Th/s
| 13±
5%Th/s
| 13.5±
5%Th/s
Estimated wall outlet power consumption
(with APW3, 93% efficiency, 25°C ambient temperature)
| ****
1176W+10%
| ****
1225W+10%
| ****
1274W+10%
| ****
1323W+10%
Rated voltage| 11.60~13.00V
Estimated wall outlet power efficiency
(with APW3, 93% efficiency, 25°C ambient temperature)
| ****
0098J/GH+10%
Dimensions (L x W x H)| 350mm x 135mm x 158mm
Net weight| 4.2kg
Operating ambient temperature| | 0 –| 40°C|
The server does not contain a DC/DC converter; therefore, higher input voltage will cause higher Mining efficiency.
Connecting the Power Supply
Ten PCI‐e connectors are located at the top of the S9 server for connecting the PSU as follows:
- Nine PCI‐e connectors for the hash boards. Each hash board has a set of three PCI‐e connectors.
- One PCI‐e connector is located on the controller.
Each hashboard must be powered by the same PSU to prevent possible damage and instability.
To connect the power supply:
- Connect PSU power cable connectors to each of the nine PCI‐e connectors on the top of the S9 server, ensuring that each hash board is powered by the same PSU.
- Connect a PSU power cable connector to the S9 PCI‐e connector on the controller.
- Connect the network cable to the ETH port.
- To power up your S9 server, connect the PSUs to the power wall outlet.
If you are using more than one PSU, power up the PSU connected to the controller AFTER you have Powered up the other PSU(s).
Setting Up the Server
To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.
- Go to the following site: https://shop.bitmain.com/support/download
- Choose ‘Others’ and download the following file: IPReporter.zip
- Extract the file.
- The default DHCP network protocol distributes IP addresses automatically.
- Right‐click IPReporter.exe and run it as Administrator.
- Select one of the following options:
- Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
- Default – suitable for home servers.
- Click Start.
- On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).
- In your web browser, enter the IP address provided.
- Proceed to login using root for both the username and password.
- In the Network section, you can assign a Static IP address (optional).
- Click Save & Apply.
Configuring the Server
Setting Up the Pool
To configure the server:
- Click General Settings.
- Set the options according to the following table:
Option| Description
---|---
Pool URL| Enter the URL of your desired pool.
The S9 server can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3).
The pools with low priority will only be used if all higher-priority pools are offline.
Worker| Your worker ID on the selected pool.
Password| The password for your selected worker.
3. Click Save & Apply to save and restart the server.
Monitoring Your Server
To check the operating status of your server:
- Click the status marked below.
- Monitor your server according to the descriptions in the following table:
Option| Description
---|---
ASIC#| Number of chips detected in the chain.
Frequency| ASIC frequency setting.
GH/S(RT)| The hash rate of each hash board ( GH/s)
Temp(PCB)| The temperature of each hash board (°C). (Applied only to servers with fixed frequency)
Temp(Chip)| The temperature of the chips on each hash board (°C).
ASIC status| One of the following statuses will appear:
● O ‐ indicates OK
● X ‐ indicates the error
● ‐ ‐ indicates dead
Note:
The S9 server is with automatic frequency adjustment. Firmware will stop
running when the Temp(chips) reaches 125-135 °C, there will be an error
message “Fatal Error: Temperature is too high!” shown at the bottom of the
kernel log page.
Administering Your Server
Checking Your Firmware Version
To check your firmware version:
- In System, click the Overview tab.
- File System Version displays the date of the firmware your server uses. In the example below, the server is using firmware version 20170108.
Upgrading Your System
Make sure that the S9 server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.
To upgrade the server’s firmware:
- In System, click Upgrade.
Regulation
FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class
A digital device, according to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used under the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct
the interference at his own expense.
EU WEEE:
Disposal of Waste Equipment by Users in Private Households in the European
Union
This symbol on the product or its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>