Ansell LIGHTING Blacksmith 3 Asymmetrical LED Floodlight Installation Guide
- May 15, 2024
- Ansell LIGHTING
Table of Contents
Installation Instructions
Product Code: [AKAR/1/]
Warranty Information
For warranty details please contact your local representative or visit our
website: www.anselluk.com
It is highly recommended that all Ansell luminaires are installed /
maintained by a fully qualified electrician and wired in accordance to the
latest IEC standards or national equivalent.
Mains power must be switched off during any installation or maintenance.
Should the product fail during the warranty period, Ansell will repair or
replace the product in question.
Ansell do not accept any responsibility for any installation costs associated
to the replacement of this product.
“ Please Note – The warranty period shall be null and void in the
following circumstances:
Failure by the installer, end user or any third party to exercise caution to
protect any covered product or part from outside damage, adverse temperature,
humidity conditions, fluctuations in the electrical system or physical abuse
as well as failure related to poor workmanship in the installation of the
products or parts. Inability to provide correct product information. Any
questions or concerns with the product, please contact your local
representative.”
Packing List
Safety Rope| 1 PCS
Physical Dimensions (Unit: mm/inch)
Mounting
100W/150W
Mounting height of the lamp should not exceed 15m.
Recommended screw size: M12 Rotation angle
When adjusting the angle, please hold the lamp body by hand to prevent it from
falling.
Safety rope installation
DMX512 Control
Factory default mode for DMX control :
Default address is the same for each luminaire. Take RGBW version for example,
there are 4 addresses for each luminaire, that is address 1 for R; 2 for G; 3
for B; 4 for W. When turn on the luminaire, the four colors light up together
without flashing if no input signal is detected about 10 seconds
later. Please connect a
signal amplifier every 100 meters or every 32 lights.
35W 100W/150W
-
It is recommended to add 0.25W/1200 DMX Termination Resistor at the end of each string of luminaires. SS-960RDM(Optional)
The DMX controller needs to be purchased separately. We suggest buy our SS- 960RDM controller if you need to change the DMX address settings. Signal Amplifier(Optional)
It is suggested to connect a signal amplifier every 100 meters or every 32 lights, which can improve the signal stability.
If RDM controller is used instead of DMX512 controller, the signal amplifier must be compatible with RDM controller, better to purchase from us directly.
Signal line reversed connection will cause following defects:- The luminaire is not controlled.
- The luminaire keeps flickering.
DALI Blutooth (CASAMBI) Casambi app operation method
Casambi app is easy to use. Follow these simple steps.
- Download the app from Apple App Store or Google Play Store.
- Turn on your Casambi enabled luminaires.
- Open the app.
- Casambi app will automatically find all Casambi enabled luminaires that are switched on.
- Tap on the ‘Take all luminaires into use’.
- Casambi app will automatically add all luminaires to one network and open the ‘Luminaires’ tab.
Visor Installation (Optional Accessories)
Visor Dimensions (Unit: mm/inch)
Product Specifications | 35W | 100W | 150W |
---|---|---|---|
Input Voltage | 100-240VAC / 220-240VAC | ||
Power Frequency | 50 / 60 Hz | ||
Outlook Dimensions | 219.5x330x100mm | ||
(8.64″x12.99″x3.94″) | 450x452x160mm |
(17.72″x17.79″x6.30″)
Luminaire Net Weight| 3.7±0.3kg
(8.15±0.66Lbs)| 10±0.3kg
(22.04±0.66Lbs)
Projected Area| 0.04m2(0.35ft2)| 0.12m2(1.12ft2)
Working Temperature| -30°C to +50°C(-22°F to +122°F)
Storing Temperature| -40°C to +70°C(-40°F to +158°F)
Ansell Electrical Products
Unit 6B, Stonecross Industrial Park, Yew Tree Way, Warrington, WAS 3JD| Ansell
(Sales & Distribution)
Unit 2, M2 Business Park, Duncrue Street,
Belfast, BT3 9AQ| Ansell (Sales & Distribution) Republic of Ireland Limited
Unit G1, Block G, Calmount Park, Calmount Avenue Dublin 12, D12 TH56
---|---|---
www.anselluk.com
Warrington Tel: +44 (0)1942 433333 Belfast
Tel: +44 (0)2890 773750 International
Tel: +44 (0)1942 433343 Spain
Tel: OO 34 938 005642
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>