TDE Instruments DPM72 Digalox® -MPN digital panel meter Instruction Manual
- June 4, 2024
- TDE Instruments
Table of Contents
- TDE Instruments DPM72 Digalox® -MPN digital panel meter Instruction
- 1. Description
- 2. Specification
- 3. Connections
- 4. Configuration
- 5. Source value addresses
- 6. Status LEDs
- 7. Communication status display
- 8. Messages on the display
- 9. Contact details
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TDE Instruments DPM72 Digalox® -MPN digital panel meter Instruction
Manual
1. Description
The Digalox® DPM72 devices with XBEE interface can communicate with other
DPM72 devices via XBEE radio technology (2.4 GHz mesh network). In this way,
measured values from remote devices can be integrated into a display as remote
values. Using the radio interface the devices can also be configured
individually.
The mesh network offers a robust connection that ensures continued operation
even if a single radio node fails. Each additional node acts as a router,
increasing the range of the network.
2. Specification
- 2.4 GHz (IEEE 802.15.4) mesh network
- Radio module: XB3-24Z8UM-J (Digi XBee 3 Zigbee 3.0, 2.4GHz, Micro, U.FL Ant, MMT)
- Antenna connector: SMA
- Range between two radio nodes: up to 60 m indoors, up to 1200 m outdoors with a clear line of sight
3. Connections
4. Configuration
To configure a device, plug the XBEE stick into the computer. The driver of
the stick is installed automatically if the computer is connected to the
Internet. If the XBEE connection settings of the device should be reset,
short-circuit connector J8 and open it again. This switches the device to
configuration mode.
The display (if present) shows “XBEE: Config”, the measurement function is
deactivated.
The device can be configured using the “Digalox® Manager” software. In
particular, the XBEE connection settings “Network ID” and “Link key” should be
changed on the General tab so that they differ from the default settings.
Afterwards, the measuring function is active. “Network ID” and “Link key” must
be the same for all devices of a network.
The XBEE role “Coordinator” must be assigned to one device. The coordinator
starts and manages the network. There can only be one coordinator and it must
be active at all times. The other devices should receive the XBEE role
“Router”. They can connect to a started network and integrate other devices.
Using the XBEE remote values tab, 4 remote values can be read from other
devices. In order to display these remote values, they must be selected as
value types of display values on the display values tab.
For devices with a display, all values that are to be transmitted must also be
visible on the display. Devices without a display provide the first four
display values. By setting jumpers J4-J6, other display values are provided
accordingly.
5. Source value addresses
Address | Data type | Description |
---|---|---|
0x0000 | int8 | Chosen display value index |
0x0001 | int8 | (0) DC or (1) AC measurement active |
0x8000-0x8003 | int64 | Display value 1-4 as int64 |
0xC000-0xC003 | float32 | Display value 1-4 as float32 |
6. Status LEDs
There are three LEDs on the back of the device that indicate the device status.
Description | Status |
---|---|
Power (green) shines | Device on |
Assoc (orange) shines | Device not connected |
Assoc (orange) flashes | Device connected |
Act (rot) shines | Device sends data |
7. Communication status display
The state of the communication is shown on the display.
8. Messages on the display
Display | Meaning | Solution |
---|---|---|
XB timeout S…x | Slave …x does not respond | Check slave configuration |
XB tx err S…x | Data transfer problem when sending to slave …x | Check |
configuration
| Data transfer problem reference :
255 = None
254 = Telemetry
253 = Command 252 = Slave transfer
status
0x00 = Success
0x01 = No ACK received
0x22 = Not connected to network 0x35 = Encryption error
0x7A = Invalid host address
…
| ****
If necessary, read the transmit status number in the XBEE3 documen- tation
XB response
| Slave …x responds with error message
1 = Uninitialized
2 = Invalid command 3 = Invalid status
4 = Invalid CRC 5 = Invalid slave
6 = Invalid interface
7 = Communication failed 8 = Buffer overflow
9 = Invalid address 10 = Device failure 11 = Device busy
12 = Gateway path unavailable
13 = Gateway target device failed to respond
| ****
Check configuration
9. Contact details
TDE Instruments GmbH, Gewerbestraße 8, D-71144 Steinenbronn
Phone: +49 7157 20801
E-mail: info@tde-instruments.de
Internet: www.tde-instruments.de, www.digalox.com