Danfoss iC7-Automation Configurators User Guide
- May 15, 2024
- Danfoss
Table of Contents
Danfoss iC7-Automation Configurators
Product Information
Specifications
- Product Name: iC7 Series Frequency Converters
- Manufacturer: Danfoss
- Safety Features: Multiple safety warnings and precautions
Product Usage Instructions
-
Installation Safety
Before installing the iC7 Series Frequency Converters, ensure you have read and understood all safety instructions provided in the manual. -
Powering On
Ensure the power source is compatible with the converter’s requirements. Connect the converter following the installation guidelines provided. -
Operation
Follow the operational instructions provided in the user manual to set up and operate the frequency converter effectively. -
Maintenance
Regularly inspect the converter for any signs of wear or damage. Follow maintenance procedures outlined in the manual to ensure optimal performance.
FAQ
-
Q: What should I do if I encounter a warning message while using the iC7 Series Frequency Converters?
A: If you encounter a warning message, immediately stop using the converter and refer to the user manual for guidance on how to address the specific warning. -
Q: How can I troubleshoot common issues with the frequency converter?
A: Refer to the troubleshooting section in the user manual for step-by- step instructions on identifying and resolving common issues that may arise during usage.
Scan to access more documentation
**Installation Safety Instructions
**
Overview
This safety guide is to be used only to install the drive. When programming
or operating the drive, refer to the application guide or operating guide for
applicable safety instructions. To install this product safely:
- Check that the content of the delivery is correct and complete.
- Never install or start up damaged units. File a complaint immediately to the shipping company, if you receive a damaged unit.
- Follow the instructions provided in this safety guide and the accompanying installation guide.
- Make sure that all personnel working on or with the drive have read and understood this guide and any additional product manuals. Contact Danfoss if you are unclear of the given information, or if you are missing information.
Target Group and Necessary Qualifications
Correct and reliable transport, storage, installation, operation, and
maintenance are required for the trouble-free and safe operation of the drive.
Only skilled personnel are allowed to perform all related activities for these
tasks. Skilled personnel are defined as properly trained staff, who are
familiar with and authorized to install, commission, and maintain equipment,
systems, and circuits following pertinent laws and regulations. Also, the
skilled personnel must be familiar with the instructions and safety measures
described in this manual and the other product-specific manuals. Non-skilled
electricians are not allowed to perform any electrical installation and
troubleshooting activities. Only Danfoss-authorized, skilled personnel are
allowed to repair this equipment. Further training is required to perform the
activities related to repair.
Safety Symbols
General Safety Precautions
WARNING
LACK OF SAFETY AWARENESS
This guide provides important information on preventing injury and damage to
the equipment or the system. Ignoring this information can lead to death,
serious injury, or severe damage to the equipment.
- Make sure to fully understand the dangers and safety measures present in the application.
- Before performing any electrical work on the drive, lock out and tag out all power sources to the drive.
HAZARDOUS VOLTAGE
AC drives contain hazardous voltage when connected to AC mains or connected on
the DC terminals. Failure to perform installation, start-up, and maintenance
by qualified personnel can result in death or serious injury.
- Only qualified personnel must perform installation, start-up, and maintenance.
DISCHARGE TIME
The drive contains DC-link capacitors, which can remain charged even when the
drive is not powered. High voltage can be present even when the warning
indicator lights are off. Failure to wait the specified time after power has
been removed before performing service or repair work can result in death or
serious injury.
- Stop the motor.
- Disconnect all power sources, including permanent magnet-type motors.
- Wait for capacitors to discharge fully. The discharge time is shown on the exterior of the drive.
- Measure the voltage level to verify full discharge.
WARNING
ELECTRIC SHOCK
AC drives contain hazardous voltage when connected to AC mains, DC terminals,
or motors. Failure to disconnect all power sources, including permanent
magnet-type motors and DC load sharing, can result in death or serious injury.
WARNING
UNINTENDED START
When the drive is connected to the AC mains or connected on the DC terminals,
the motor may start at any time, causing a risk of death, serious injury, and
equipment or property damage.
- Stop the drive and motor before configuring parameters.
- Make sure that the drive cannot be started by an external switch, a Fieldbus command, an input reference signal from the control panel, or after a cleared fault condition.
- Disconnect the drive from the mains whenever safety considerations make it necessary to avoid unintended motor start.
- Check that the drive, motor, and any driven equipment are in operational readiness.
CAUTION
INTERNAL FAILURE HAZARD
- An internal failure in the drive can result in serious injury when the drive is not properly closed.
- Ensure that all safety covers are in place and securely fastened before applying power.
Lifting the Drive
NOTICE
LIFTING HEAVY LOAD
The weight of the drive is heavy and failure to follow local safety
regulations for lifting heavy weights may cause death, personal injury, or
property damage.
- Check the weight of the drive. The weight is provided on the outside of the shipping box.
- If needed, ensure that the lifting equipment is in proper working condition and can safely lift the weight of the drive.
- Test lift the unit to verify the proper center of gravity lift point. Reposition if not level.
Electrical Installation Precautions
Before you do electrical work on the drive, lock out and tag out all power
sources to the drive.
ELECTRICAL SHOCK AND FIRE HAZARD
The drive can cause a DC in the PE conductor. Failure to use a Type B residual
current-operated protective device {RCD) may lead to the RCD not providing the
intended protection and therefore may result in death, fire, or other serious
hazard.
- Ensure an RCD device is used.
- When an RCD is used for protection against electrical shock or fire, use only a Type B device on the supply side.
WARNING
INDUCED VOLTAGE
Induced voltage from output motor cables that run together can charge
equipment capacitors, even with the equipment turned off and locked out.
Failure to run output motor cables separately or to use shielded cables could
result in death or serious injury.
- Run output motor cables separately or use shielded cables.
- Simultaneously lock out all the drives.
ELECTRICAL SHOCK HAZARD – HIGH LEAKAGE CURRENT
Leakage currents exceed 3.5 mA. Failure to connect the drive properly to the
protective earth may result in death or serious injury.
- Ensure reinforced protective earthing (PE) conductor according to IEC 60364-5-54 cl. 543.7 or local safety regulations for equipment with leakage current >3.5 mA.
- PE conductor with a cross-section of at least 10 mm2 Cu or 16 mm2 Al, or an additional PE conductor of the same crosssectional area as the original PE conductor as specified by IEC 60364-5-54, with a minimum cross-sectional area of 2.5 mm2 (mechanical protected) or 4 mm2 (not mechanical protected).
- PE conductor is completely enclosed within an enclosure or otherwise protected throughout its length against mechanical damage.
- PE conductor that is part of a multi-conductor power cable with a minimum PE conductor cross-section of 2.5 mm2 {permanently connected or plugged in by an industrial connector). The multi-conductor power cable must be installed with an appropriate strain relief.
LEAKAGE CURRENT HAZARD
Leakage currents exceed 3.5 mA. Failure to ground the drive properly can
result in death or serious injury.
- Ensure that the minimum size of the ground conductor complies with the local safety regulations for high touch current equipment.
Danfoss A/S Ulsnaes 1
drives.danfoss.com
Any information, including, but not limited to information on the selection of
the product, its application or use, product design, weight, dimensions,
capacity or any other technical data in product manuals, catalog descriptions,
advertisements, etc. and whether made available in writing, orally,
electronically, online or via download, shall be considered informative and
is only binding if and to the extent, explicit reference is made in a
quotation or order confirmation. Danfoss cannot accept any responsibility for
possible errors in catalogs, brochures, videos, and other material. Danfoss
reserves the right to alter its products without notice. This also applies to
products ordered but not delivered provided that such alterations can be made
without changes to the form, fit or function of the product. All trademarks in
this material are property of Danfoss NS or Danfoss group companies. Danfoss
and the Danfoss logo are trademarks of Danfoss NS. All rights reserved.
Danfoss NS© 2023.05
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>