VANIMAN 10201 StoneVac II 120V Instructions
- June 17, 2024
- VANIMAN
Table of Contents
VANIMAN 10201 StoneVac II 120V
Product Information
Specifications
- Model: StoneVac II 120V
- Manufacturer: Vaniman Mfg. Co.
- Power Source: 120V AC
- Usage: Ideal for use with abrasives or micro-blasters
- Replacement Bag: Vaniman P/N 97002 (pack of 12)
Product Usage Instructions
Packing List
Save the shipping box and foam for future service to prevent damage during
shipping.
Initial Setup
- Remove all parts from the box and verify against the packing list.
- Remove the hose from inside the dust bin and any protective packaging.
- Plug the power cord into a standard wall socket.
- Turn on the StoneVac II by pushing the switch to the ON position.
Maintenance
- Cleaning the Filter: Use the self-cleaning feature by holding the Power switch in the CLEAN position for several seconds. Wait for dust to fall into the bin before turning the unit back on.
- Emptying the Dust Bin: Open the door, slide out the bin, close the bag, replace it with a Vaniman bag, and slide back into the unit.
Electrical Protection
If the unit does not operate, check the circuit breaker at the back. Reset if
necessary. Contact the dealer or Vaniman for assistance if needed.
Recommended Usage
Use with abrasives or micro-blasters. Regularly service or replace the filter.
Consider using Vaniman’s Pre-Filter/Accumulator to increase filter life.
FAQ
-
Q: What should I do if the StoneVac II does not turn on?
A: Check the circuit breaker at the back of the unit and reset if necessary. If it still does not operate, contact your dealer or Vaniman for technical assistance. -
Q: How often should I clean the filter?
A: Clean the filter when you notice a drop in suction. Use the self-cleaning feature for optimal results.
PACKING LIST
- 1 – StoneVac II
- 1 – 2½” x 6’ Hose
- 1 – Plastic Disposal Bag
- 1 – Power Cord
IMPORTANT SERVICE INFORMATION: SAVE SHIPPING BOX AND FOAM FOR FUTURE SERVICE. SHIPPING WITHOUT PROPER FOAM MAY CAUSE DAMAGE TO THE UNIT.
INSTRUCTIONS
- Remove the unit and other parts from the box and check against the packing list. Remove the hose from inside the dust bin as well as any protective paper packing material.
- Plug the power cord into a standard wall socket. Try the StoneVac II by pushing the switch to the “ON” position.
- The vacuum hose supplied slips onto the vacuum connection in the back of the unit and the other end connects to the collection device desired. The ideal location for the StoneVac II is under the bench where the user works. The single station hose supplied is 2½” x 6′ long and accordions to the desired length. Hose extensions and adaptors are available from your dealer. We recommend, however, that you try to keep the total length of the hose less than 6 feet between the StoneVac II and the dust collection point; a longer hose will reduce suction.
MAINTENANCE
-
Cleaning the Filter – When a noticeable drop in suction occurs in the unit, it is time to clean the filter. To use the self-cleaning feature of the StoneVac II, push and hold the Power switch in the “CLEAN” position for several seconds. Optimum cleaning takes place within 5 seconds. For best results, wait an additional 10-15 seconds with the Power switch in the “OFF” or centre position, this allows the dust cleaned from the filter to fall into the dust bin before turning the unit on again.
-
Emptying the Dust Bin – Depending on usage, the unit will need to be emptied at different intervals. To check the level of dust in the bin, open the door and observe the dust level. To empty, open the door and slide the bin from the unit. Pull the edges of the bag together to close the bag for disposal. Replace the bag with a Vaniman replacement and carefully slide the dust bin back into the unit. Replacement bag re-order number P/N 97002 (pack of 12).
-
Replacing the Filter Cartridge – Regularly check the filter to make sure it is secure and properly seated against the filter mounting/sealing plate. Periodically, the filter cartridge will become worn or clogged beyond the use of the “CLEAN” feature. In cases when dust collector usage is heavy, changing intervals may be as frequent as 3-6 months. To replace the filter, follow the instructions above to remove and empty the dust bin. With the dust bin removed, reach underneath the Filter Cartridge and unscrew the filter retaining nut. Remove the nut and washers and pull the filter downward then forward out of the unit. Replace the filter with a new filter cartridge then reverse removal instructions for proper installation. Filter Cartridge re-order P/N 97001.
NOTE: Be sure to replace the rubber washer FIRST and the metal washer SECOND. Securely fasten the filter retaining nut. Improper installation may cause dust to pass into the air. -
Electrical Protection – The StoneVac II is protected by a circuit breaker. If the unit is plugged in and does not operate, check to see if the circuit breaker was activated by inspecting it on the back of the unit where the power cord enters the unit. If the circuit breaker was activated, push the button in the centre to reset it. If the unit still does not operate, contact your dealer or call the factory at 1-800-VANIMAN for technical assistance.
RECOMMENDED USAGE
- Individual workstation (2½” hose) or dry model trimmer dust collection for trimming or grinding Die Stone. While the StoneVac II was designed specifically for Die Stone, it will also handle other dust developed at the same workstation such as alloy, porcelain, and acrylic.
- The StoneVac II can be used with abrasives or micro-blasters. If used for this application, the filter must be serviced or replaced regularly. Additionally, Vaniman’s Pre-Filter/Accumulator helps capture abrasive before it reaches the dust collector, increasing the life of the filter. Large Accumulator – P/N VMC-A300
REPLACEMENT PARTS
The following items are offered to enhance the usage of your quality Vaniman unit. These items can be ordered through your supplier using the following part numbers. Please feel free to contact Vaniman Mfg. Co. with questions regarding our products.
Fig. # | Description | Reorder Part Number |
---|---|---|
1 | Replacement Shaker Motor | 97003 |
Not Shown | Shaker Clamp | 3526 |
2 | Wing Nut | 2847 |
3 | Washer | 2868 |
4 | Rubber Washer | 1783 |
5 | Replacement Filter (includes rubber washer) | 97001 |
6 | Remote Plug | 1427 |
7 | Power Inlet | 5195 |
8 | Circuit Breaker Switch, 15Amp | 3285 |
9 | Top Panel Screw, 6-32 x 3/8” FHMS | 3005 |
10 | Motor Plate Screw, 6-32 x 1/2” Pan MS | 2080 |
11 | Replacement Motor – Yellow Dot | 97093 |
Not Shown | Motor Brushes Kit – Yellow Dot | Contact Vaniman for Information |
12 | Switch ON/OFF/CLEAN | 3282 |
Not Shown | Protective Switch Cover | 1003B |
13 | Door Latch | 3040 |
14 | Door Gasket | 97150 |
Not Shown | Power Cord | 3006 |
25799 Jefferson Ave.
Murrieta, CA 92562
1-800-VANIMAN (826-4626)
www.vaniman.com
sales@vaniman.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>