Overview
Echo Inspire Stations provide preset, zone, space combine, and color controls
for use with Echo and Sensor control systems.
Reference the ETC website at etcconnect.com for
related Inspire station documentation including the datasheet, which provides
a complete listing of station types.
Stations are available in 1, 2, 4, 6, and 8button assemblies and a 4button
with fader station. Station buttons are backlit by both blue and amber LEDs.
The 4button with fader station knob is backlit with a blue LED.
This document guides you through the installation and local DIP switch setup
of the Inspire Station. For more detailed information about local
configuration options available for the Inspire Station, reference the Echo
Inspire Station Programming Guide.
Custom Configuration
For information about the custom configuration options available for the
Inspire Station using EchoAccess, reference the EchoAccess Mobile App
integrated help system. User documentation is available for download on our
website etcconnect.com.
Note: To configure the Inspire Station using EchoAccess, the station Function
switch must be set to Custom.
Prepare for Installation
Inspire Stations ship with station electronics, a decorator-style wall plate,
a termination kit, and a template of standard button labels. You can install
the station into an industry-standard back box (provided by others) or a
surface-mounted back box (sold separately and available from ETC).
Inspire stations to connect to the EchoConnect station communication bus.
EchoConnect is a bi-directional protocol that uses one pair of wires (data +
and data -) for both data and power. ETC recommends using Belden 8471 Class 2
wire (or approved equal see the ETC cable cross database
etcconnect.com/Support/Cable-Cross-Database for equal alternatives). The total combined length of
an EchoConnect wire run using Belden 8471 may not exceed 500 m (1,640 ft),
with a maximum distance of 400 m (1,312 ft) between any two devices.
Note: All control wiring should be installed and terminated by a
qualified installer and should follow standard wiring installation practices.
Leave approximately 25.4 cm (10 in) of wiring in the back box for connection
and to allow slack for future service needs.
Note: ETC requires that all stations and devices be grounded for ESD
protection. Pull an additional 2.5 mm2 (14 AWG) wire for grounding when
control wires are not installed in the grounded metal conduit.
Environmental
Indoor installation only, 050°C (32122°F), 595% non-condensing humidity.
Installation
Installation should follow all local codes and standard electrical practices.
Note: NEC Class 2 products to be wired in accordance to NEC Article 725
and local jurisdiction requirements.
The back box should be installed plum and square for best results. Ensure that
the back box is clean and free of obstructions and that all wiring is
installed correctly. Inspire stations ship with a termination kit for use with
Belden 8471 (or equivalent wire) and contains a power pigtail, a ground wire
pigtail, spacers, and all required wire termination connectors for
installation.
Note: When using Category 5 (or equivalent) cable on the EchoConnect
communication bus, please note the following:
- Cat5 wiring must be terminated using EchoConnect Cat5 Termination Kit and must be installed using a bus topology. Refer to the installation guide that is provided with the Cat5 Termination Kit (7186A1207) for information to terminate Cat5 wiring.
- Not all topologies are supported using Cat5; careful planning is required to ensure the proper termination kits are available and the wire is pulled appropriately.
Connect Wiring
-
Pull all required wiring (data+, data-) into the back box. As needed, pull an additional ESD ground wire (required only when the station is not installed in a grounded metal conduit).
-
Connect the station ESD ground wire pigtail.
a. Strip 11 mm (7/16 in) of insulation from the ends of the station ground wire pigtail, provided in the termination kit, and the incoming ground wire.
b. Use one WAGO connector, provided in the termination kit, to connect the station ESD ground pigtail and the incoming ground. For stations using grounded metal conduit, connect the ground pigtail to the metal back box ground location.
c. Install the ESD ground wire pigtail FASTON connector to the mating receptacle on the station electronics. -
Terminate EchoConnect wires. EchoConnect is topology free; you may install the wires in any combination of bus, star, loop, or home run.
a. Strip 11 mm (7/16 in) from the ends of each power pigtail wire provided in the termination kit and the installed control wires.
b. Use the provided WAGO connectors to connect the power pigtail wires and the installed Belden 8471 control wires. One WAGO should be used for the white wire pair (data +) and one for the black wire pair (data -). Open the terminal levers on the WAGO connector and insert the installed Belden 8471 wire and the lead from the power pigtail into the terminals, and then close the levers.
c. Install the two-pin connector from the power pigtail to the mating receptacle on the station electronics.
Rotary and DIP Switches
Rotary and DIP switch settings are accessible on the rear of the station. Set
Space and Address
Two rotary switches on the rear panel of the station provide space assignment
and station address assignment. Each station must be set to a unique station
address for the assigned space.
By default, these switches are set to Space 1, Station Address 1. Station
commands are shared by all devices within an assigned space.
DIP Switch Settings
DIP switches on the rear panel of the station provide for the designation of
“Off” functionality, the ability to disable amber button LEDs, 4-button
station space combine controls, 4-button with fader station color control mode
settings, and the ability to restore the station to its factory defaults.
1| Use Off -Provides ‘ Use of’ functionality, or:
1-button station only: When set to On and the Function switch is set to Preset
mode, enables sequence toggle.
---|---
2| Amber LED Disable- Provides the ability to disable use of the amber LEDs.
When this switch is set to On, the amber button LEDs on the station are
disabled. The default setting is Off, enabling amber LEDs. (Amber LEDs is
provided as the default so the station glows in darkened spaces, allowing it
to be easily located.)
3| Space Combine Mode-4-button station only. Changes the station personality,
enabling space to combine.
4| Fade Time Override (Disable) -Applies a 0-second fade time to all station
actions for non-dim switched mode behavior (when dimming features are not
wanted).
5| Zone Color Control -4-button with fader station only. Changes the Zone mode
(function selection switch) of the station to Color Control mode. Seepage 5.
6
7| Reserved for future development.
8| Restore to Defaults at boot. Setting this DIP switch and cycling power to
the station restores the station to factory defaults
Note: When the station Function switch is set to Custom, only DIP switch
number 8 applies. All other DIP switch settings are ignored. Reference the
Echo Inspire Station Programming Guide (available for download from
etcconnect.com) for details on use of the Function selection switch.
4-button with Fader Station Color Mode DIP Switch Settings
DIP switches 5 and 6 on the 4-button with the fader station set Color Mode
functionality for the fader knob when the station is also set to Zone control
mode.
Mode| DIP 5| DIP 6 ……………………………………………….Push Action|
---|---|---|---
Intensity| Off| Off| Selection Toggle| Selection Raise/ Lower
Color Temp| Off| On| Toggle between Intensity and Color Temp| Selection Raise/
Lower for Intensity and Color Temp
HSI Color| On| Off| Toggle between Intensity, Saturation, and Hue| Selection
Raise/ Lower for Intensity, Saturation, and Hue
Studio| On| On| Toggle between Intensity, Color Temp, and Tint| Selection
Raise/ Lower for Intensity, Color Temp, and Tint
Station Configuration
The Inspire Station has on-board switch and button settings that are available
from the front of the station when it is installed and the cover is removed.
Reference the Echo Inspire Station
Programming Guide for information about local settings on your Inspire
Station, including configuration, program and record mode, and station
functionality. ETC user documentation is available for free download from our
website etcconnect.com. Reference the EchoAccess
Mobile App integrated help system for details about custom configuration using
EchoAccess.
Install Button Legends
Inspire Stations ship with standard button legends installed beneath a clear
lens. An additional sheet of standard button legends are provided for field
installation as needed.
Note: Customize and print your own button legends on standard
transparency. Download the button legend template provided on the ETC website
etcconnect.com.
Each button can have a legend, installed beneath the button lens. To remove,
install, or replace a button legend you must first remove the bezel and button
lens from the station electronics.
-
Remove the bezel from the station electronics. Each corner of the bezel is provided with a notch to assist with bezel removal. Use your thumbnail to lift a corner free, and then gently remove the bezel from the station.
-
Remove the button lens.
Using the pads of your thumbs, press on the lens and slide the lens either left or right, toward the button hinge points. -
Once the lens is removed, remove the existing legend and replace it with another standard legend as provided with this station, or insert a custom legend.
-
Reattach the lens onto the button by first aligning the grooves of the lens to the button, then sliding the lens in place starting at the hinge. Slide the lens until it covers the entire button and clicks into place.
-
Replace the bezel when all legends and lenses are in place.
Install the Station into the Back Box
Receptacle spacers are provided to help align the station and cover flush
against the wall in flush-mount applications. The spacers are not required
when installing the station into a surface-mount back box.
-
Insert the station electronics and wiring into the back box. To install multiple stations (multi-gang), insert the station electronics into the back box from the right to the left side for the best alignment and fit. The alignment bracket will slightly overlap the station to the right when properly installed.
-
Use spacers as needed to provide a flush-mounted station.
a. Fold the spacer in a zig-zag fashion and press the stack together to achieve the thickness needed to fill the gap between the station, wall surface, and the back box.
b. Cut off and discard the excess.
c. Place the stack between the station electronics and the flush-mounted back box. -
Secure each station’s electronics in place using the two screws provided. If using spacers, insert the screws through the spacers as well.
Note: To ensure successful station and wall plate installation, do not over-tighten the screws. If screws are over-tightened, button activation can be negatively impacted.
Install the Wall Plate
The wall plate is secured to the station with built-in magnets.
- Align the top of the wall plate to the station and angle the bottom approximately 20 degrees.
- Hook the top of the wall plate to the tabs located on the station electronics assembly. To ensure the wall plate is hooked properly on the top hook, wiggle it slightly side to side.
- Swing the bottom of the wall plate down until the magnets engage.
- If the wall plate does not fully attach automatically, wiggle the bottom of the plate until all of the magnets are seated properly to the station and the plate is secure.
Note: If you are installing a multi-gang wall plate and the stations are misaligned in the back box, the wall plate will not attach properly. Loosen the screws that secure the station to the back box, adjust each station to improve the alignment, secure the screws, and then install the wall plate again.
Echo Inspire Station
Corpora te He a quarters n Middleton, WI, USA
+1 608 831 4116 Global Offices London, UK
Rome, IT /Holzkirchen, DE
Paris, FR /Hong Kong Dubai, UAE
Singapore | New York, NY | Orlando, FL
Los Angeles, CA | Austin, TX Web etcconnect.com
Support support.etcconnect.com Contact etcconnect.com/contactETC
© 2021 Electronic Theatre Controls, Inc. Trademark and patent info:
etcconnect.com/ip
Product information and specifications are subject to change.
ETC intends this document to be provided in its entirety. 7 1 8 6 M 2 1 4 0
Rev F Released 2021-06
References
- ETC - Theatre, Film, Studio and Architectural Lighting
- Contacting ETC
- Patents & Trademarks
- Home - Electronic Theatre Controls Inc
- ETC - Theatre, Film, Studio and Architectural Lighting
- Contacting ETC
- Patents & Trademarks
- Home - Electronic Theatre Controls Inc
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>