DSC PC1864 GT+ Cellular Communicator and Programming the Panel User Guide
- June 17, 2024
- DSC
Table of Contents
PC1864 GT+ Cellular Communicator and Programming the Panel
PC1864
Wiring Trikdis GT+ Cellular Communicator and Programming the Panel
CAUTION
- The communicator should be installed and maintained by qualified personnel.
- Prior to installation, it is advised to read full device installation manual carefully in order to avoid mistakes that can lead to malfunction or even damage the equipment.
- Disconnect the power supply before making any electrical connections.
- Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty.
Schematics forwiring the communicator to the security control panel
Following the schematics provided below, wire the communicator to the control
panel. DSC PC1864 panel do not need
to be programmed.
LED indication of communicator operation
Indicator | Light status | Description |
---|---|---|
NETWORK | Off | No connection to cellular network |
Yellow blinking | Connecting to cellular network | |
Green solid with yellow blinking | Communicator is connected to cellular |
network. Yellow blinks count Indicates signal strength, 10 blinks
max. Sufficient cellular signal strength for 4G network-level 3 (three yellow
flashes).
DATA| Off| No unsent events
Green solid| Unsent events are stored in buffer
Green blinking| (Configuration mode) Data is being transferred to/from
communicator
POWER| Off| Power supply is off or disconnected
Green solid| Power supply is on with sufficient voltage
_
Yellow solid| Power supply voltage is insufficient (s11.5V)
Green solid and yellow blinking| Configuration mode) Communicator is ready for
configuration
Yellow solid| (Configuration mode) No connection with computer
TROUBLE| Off| No operation problems
1 red blink| SIM card not found
2 red blinks| SIM card PIN code problem (incorrect PIN code)
3 red blinks| Programming problem (No APN)
4 red blinks| Registration to GSM network problem
5 red blinks| Registration to GPRS/UMTS network problem
6 red blinks| No connection with the receiver
7 red blinks| Lost connection with control panel
8 red blinks| The entered ICCID number does not match the ICCID number of the
SIM card
Red blinking| (Configuration mode) Memory fault
Red solid| (Configuration mode) Firmware is corrupted
BAND| 1 green blink| None
2 green blinks| GSM
3 green blinks| GPRS
4 green blinks| EDGE
5 green blinks| HSDPA, HSUPA, HSPA+, WCDMA
6 green blinks| LTE TDD, LTE FDD
Setting up the GT+ communicator with the app
Download and launch the Protegus application or use the browser version:
web.protegus.app.
The installer must connect to Protegus with an installer account.
Click the”Add new system” button| Enter the IMEI number of the communicator
Select security company| Press “DSC”
Press “PC1864”| Enter “Object ID” and “Module ID”. Press “NEXT”
Wait while the configuration is written| Press”Add to Protegus2″
Enter system “Name”. Press “Next”| Press “Skip”
Press on system| Wait 1 minute and press “Transfer”
Enter the e-mail of the user to whom the installer will transfer the system.
Press “Transfer”| The system will appear in Protegus on the user’s phone
Setting up the GT+ communicator with the app
After completing the setup and installation perform a system check:
-
Create an event:
– by arming/disarming the system with the control panel’s keypad;
– by triggering a zone alarm when the security system is armed. -
Make sure that the event arrives to the CMS
(Central Monitoring Station) and the Protegus app.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>