CAUTION

  • The communicator should be installed and maintained by qualified personnel.
  • Prior to installation, it is advised to read full device installation manual carefully in order to avoid mistakes that can lead to malfunction or even damage the equipment.
  • Disconnect the power supply before making any electrical connections.
  • Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty.

Schematics forwiring the communicator to the security control panel
Following the schematics provided below, wire the communicator to the control panel. DSC PC1864 GT+ Cellular Communicator and Programming the Panel -
figDSC PC1864 panel do not need to be programmed.
LED indication of communicator operation

Indicator Light status Description
NETWORK Off No connection to cellular network
Yellow blinking Connecting to cellular network
Green solid with yellow blinking Communicator is connected to cellular

network. Yellow blinks count Indicates signal strength, 10 blinks
max. Sufficient cellular signal strength for 4G network-level 3 (three yellow flashes).
DATA| Off| No unsent events
Green solid| Unsent events are stored in buffer
Green blinking| (Configuration mode) Data is being transferred to/from communicator
POWER| Off| Power supply is off or disconnected
Green solid| Power supply is on with sufficient voltage
_
Yellow solid| Power supply voltage is insufficient (s11.5V)
Green solid and yellow blinking| Configuration mode) Communicator is ready for configuration
Yellow solid| (Configuration mode) No connection with computer
TROUBLE| Off| No operation problems
1 red blink| SIM card not found
2 red blinks| SIM card PIN code problem (incorrect PIN code)
3 red blinks| Programming problem (No APN)
4 red blinks| Registration to GSM network problem
5 red blinks| Registration to GPRS/UMTS network problem
6 red blinks| No connection with the receiver
7 red blinks| Lost connection with control panel
8 red blinks| The entered ICCID number does not match the ICCID number of the SIM card
Red blinking| (Configuration mode) Memory fault
Red solid| (Configuration mode) Firmware is corrupted
BAND| 1 green blink| None
2 green blinks| GSM
3 green blinks| GPRS
4 green blinks| EDGE
5 green blinks| HSDPA, HSUPA, HSPA+, WCDMA
6 green blinks| LTE TDD, LTE FDD

Setting up the GT+ communicator with the app

Download and launch the Protegus application or use the browser version: web.protegus.app.
The installer must connect to Protegus with an installer account.

DSC PC1864 GT+ Cellular Communicator and Programming the Panel - Step
1

Click the”Add new system” button| Enter the IMEI number of the communicator
DSC PC1864 GT+ Cellular Communicator and Programming the Panel - Step
2
Select security company| Press “DSC”
DSC PC1864 GT+ Cellular Communicator and Programming the Panel - Step
3
Press “PC1864”| Enter “Object ID” and “Module ID”. Press “NEXT”
DSC PC1864 GT+ Cellular Communicator and Programming the Panel - Step
4
Wait while the configuration is written| Press”Add to Protegus2″
DSC PC1864 GT+ Cellular Communicator and Programming the Panel - Step
5
Enter system “Name”. Press “Next”| Press “Skip”
DSC PC1864 GT+ Cellular Communicator and Programming the Panel - Step
6
Press on system| Wait 1 minute and press “Transfer”
DSC PC1864 GT+ Cellular Communicator and Programming the Panel - Step
7
Enter the e-mail of the user to whom the installer will transfer the system. Press “Transfer”| The system will appear in Protegus on the user’s phone

Setting up the GT+ communicator with the app
After completing the setup and installation perform a system check:

  1. Create an event:
    – by arming/disarming the system with the control panel’s keypad;
    – by triggering a zone alarm when the security system is armed.

  2. Make sure that the event arrives to the CMS
    (Central Monitoring Station) and the Protegus app.

trikdis.com