Atarm HY368 Zigbee WIFI Radiator Actuator User Manual
- June 17, 2024
- Atarm
Table of Contents
ZigbeeWIFI Radiator Actuator User Manual
HY368 Zigbee WIFI Radiator Actuator
Many thanks for your selection ofour products and services, and also for your trust and support to us.
Download “Smart life” or “Smart RM” App from Google play and App store| 1.
After the ZigBee gateway is configured, enter the gateway to add sub-devices,
and wait for the actuator to be powered on and the system self-check is
completed.
2.long press enter tosetting surface ,short press icon,short press to choose
to enter network connected mode, then long press , flashing access network
connected mode.
Please refer to the gateway manual for Zigbee gateway configuration.
---|---
Product Specifications
Power: 2 AAalkalinebatteries
Displayaccuracy::0.5℃
Probesensor:NTC(10k)1%
Maximumroute : 4.5mm
Insulating condition: 0-50℃
Running program: Set per 1 week as acycle
Size(mm):5389.5mm
Range of temperature display::1~70°C
Default range oftemperatureadjustment:5~35°C Maximum current:90mA
Workingenvironmenttemperature::-10~60°C Threadsize:M30*1.5
Displays & Buttons
No.| Icon|
---|---|---
A| Auto Mode Holiday mode Boost mode OpenWindow function
B| Low battery Children lock Zigbee connection status Auto mode period Set
temperature/Advanced options Valve status
C| Time setting interface hour setting minute setting
No| keys| Represent
---|---|---
D| | 1.Short press to switch manual mode and auto mode
2.Long press to enter advanced settings
3.Confirm key
E| | 1.Decrease key2.Long press 3s to lock/unlock keys
F| | 1.Increase Key
2.Long press 3 seconds to start the BOOST function: turn on the BOOST fast
heating mode, short press any key during operation to exit this function and
return to the previous working mode
Installation and initial commissioning
After power on, the screen will show all for 3 seconds.
Time setting: when flashing,then press ,display enter hour setting, press or
to adjust value,press again display enter minute setting,press or to adjust
value,press again to set week,press or to adjust value,press to confirm
setting and remember time.
Note: after the actuator completes its self-check,under normal working
status,if need to modify time, long press 3s access to advanced setting. And
press + tochoose , short press entertime setting. the same as above method.
When display “Ad”, press Start system self-check, when display “1”, this is the first step of system self-check. When Display “2”, this is the second step for self-check, after finish self-check, If there is no fault prompt, it will enter the normal working state. If there is a fault prompt, please handle the fault first, otherwise it will not enter the normal working state.
E1 | Motor fault |
---|---|
E2 | Sensor fault |
Flashing show low battery |
Special Function description
Holiday mode| press 3s access to advanced settings,short press to choose
holiday mode then short press enter temperature setting, again short press
setting days setting, press or holiday mode.
---|---
Open| 1. The actuator turns off the window opening function by default, if
you need to
Window Function| use it, you can turn it on in the advanced option 2 setting
[reset disable when changing the battery]
Long press about 3s accessto advanced settings, short press switch to auto mode setting ,short press access toauto mode setting, short press to choose which item you want, First set the auto mode to 5means:5=5+2days,6= 6+1 days, 7 = 7 days, after press to access to hour or minute setting, short press access to temperature setting. Press or to adjust value. short press choose: hour,minute, time period, and press or to adjust data, finished etting, about 10 seconds will automatic save and exist.
Period | Default period | Default temperature |
---|---|---|
1 | 6:00-8:00 | 20°C |
2 | 8:00-11:30 | 15°C |
3 | 11:30-12:30 | 15°C |
4 | 12:30-17:30 | 15°C |
5 | 17:30-22:00 | 20°C |
6 | 22:00-6:00 | 15°C |
Advanced options
Press about3-5stoaccess to advanced settings, short press until flashing, press to access to advancedoptions, press or toadjustvalue,after finish setting every time, short press to set next option,after finishing all ,don’t operate, after 10s it will automatically save andexit
No | Item | Setting parameters | default |
---|
1
| Measuring temperature correction| -9-+9℃(Displayed as the corrected room
temperature value)| -1°C
2| Open window functionparameter: temperature and running time| 1:display
means disable open window function,press key display 5°C means this function
enable(temperature setting range: 5-25°C)
2:Running time:5-60min(after enable function, press change setting)|
3| Automatic lock if no operation more than 10 minutes| 0:Disable
1: Enable| 0
4| Setting temperature minimum limit| 1-15°C| 5°C
---|---|---|---
5| Setting temperature maximum limit| 16-70°C| 35°C
6| BOOSTmoderunning time| 100s-900s , Steps of 100 seconds| 300Seconds
7| View valve open status| 0-99 99 mean valve open 100% 5 mean valve open 5%|
8| Start/stop working temperature difference
setting| 0.5-1.5| 1
9| Display mode| 0:Upward display
1:Downward display| 0
A| Control type of valve| 0: PID
1:FLOAT
2:ON/OFF| 0
B| Reset| Display 88, using or tochange
to 00, press to reset, The screen will be fully displayed for 2 seconds.| 0
C| Valve Seal Type| 0:Soft Seal
1:Hard Seal| 0