Product Infomation
Specifications:
- Product Name: GAIL Einbaustrahler, 6W, IP65, 27/30/4000K
- Input Voltage: 200 – 240 V AC, 50/60 Hz
- Output Power: 6 W max.
- IP Rating: IP65
- Colour Temperature Options: 2700 K, 3000 K, 4000 K
Product Usage Instructions
Safety Instructions:
- Risk of electric shock! Installation should be done by a professional electrician. Ensure compliance with European safety directives.
- Avoid fire hazards by not covering the lamps with heat-insulating materials.
- Use only the provided low-voltage cable for connections on the secondary side of the converter. Install downlights on suitable surfaces and ensure they shine downwards.
Installation of Mounting Springs:
Ensure that the springs are positioned correctly as shown in figure 1 of the
manual.
Installation:
Operate the GAIL recessed downlight with the provided constant current
converter. Ensure correct installation for safe operation.
Slide Switch Adjustments:
Adjust the switch for different light colours: 2700 K (W), 3000 K (N), 4000 K
(C). Determine the appropriate power supply units per circuit breaker based on
the table provided in the manual.
Technical Data:
- Input: 200 – 240 V AC, 50/60 Hz
- Output: 6 W max.
Technical Product Dimensions:
- LED Downlight: Outer Diameter: Inner Diameter: Height: Installation Depth:
- Konverter (L x B x H): 99 mm x 38 mm x 28 mm
Mounting:
Risk of electric shock! Switch off voltage before installation and prevent
accidental reactivation of voltage.
FAQ:
-
Q: Can the LED light source be replaced by the user?
A: The LED light source can be replaced by a qualified electrician as mentioned in the manual. -
Q: What should be done to avoid fire hazards during installation?
A: Avoid covering lamps with heat-insulating materials and ensure correct installation on suitable surfaces.
SAFETY INSTRUCTIONS
-
Risk of electric shock! Be sure to have a professional electrician complete installation. There is no warranty coverage for any lamps installed without observing European safety directives.
-
Fire hazard! Do not cover lamps with heat insulating materials.
-
Caution!
Only the supplied low voltage cable must be used for all connections on the secondary side of the converter. -
The Downlight is suitable for mounting on normally flamm able surfaces such as wood and particle board materials which are more than 2 mm thick. Only install downlights so that they shine downwards.
SYMBOLS
SYMBOLS IN GENERAL:
- Compliant with the applicable European CE directives.
- RoHS mark for products that do not contain heavy metals (EC Directive 2002/95/EC).
- REACH test mark for products whose chemical components are known, registered and authorised.
- Parallel circuit: Suitable for through-wiring.
SYMBOLS LED KONVERTER:
- Protection class II
- Independent converter
- Short-circuit proof
- LED control gear can be replaced by a qualified electrician.
SYMBOLS LED DOWNLIGHT:
- Do not cover the LED luminaire or control gear with heat-insulating materials.
- LED light source can be replaced by a qualified electrician.
INSTALLATION
INSTALLATION OF MOUNTING SPRINGS:
Make sure that the springs are in the right position (fig.
1).
INSTALLATION:
Only operate the protection class III recessed downlight GAIL with the
constant Current converter provided for it (including in delivery).
SLIDE SWITCH ADJUSTMENTS:
POWER SUPPLY UNITS PER CIRCUIT BREAKER:
TECHNICAL DATA
- Input: 200 – 240 V AC, 50/60 Hz
- Output: 6 W max.
- Ambient temperature: -20 bis +50° C
TECHNICAL PRODUCT DIMENSIONS:
- LED Downlight:
- outer diameter: ø 82 mm
- inner diameter: ø 68 mm
- height: 45 mm
- installation depth: 55 mm
- Konverter (L x B x H): 99 mm x 38 mm 28 mm
DISPOSAL
Dispose of electrical and electronic equipment in an environmentally sound manner. For more information, contact your local authority.
The konverter of the GAIL Set ALU5725ffSWD is a triacdimmable power supply unit on the primary side, which provides a rectified constant current of 150 mA and a maximum power of 6 W on the secondary side.
MOUNTING
Risk of electrik shock!
Switch off voltage prior to installation. Ensure that voltage cannot be
accidentally switched on again.
- Saw a hole at the installation location. The diameter is 68 mm.
- Connect the GAIL recessed downlight to the secondary side line of the converter using the connector supplied with the matching counterpart of the connector. Connect the existing 230 V AC mains voltage to the primary side of the converter (fig. 2).
- Press the springs together and place the downlight in the sawn out hole (fig. 3).
INBETRIEBNAHME:
- Connect the primary side of the LED power supply unit to the 230 V AC mains voltage or the secondary side of the trailing-edge dimmer in a voltage-free state.
- Check that the input and output cables have been connected correctly before switching on the power to operate the product.