Foxtheon iGo 3600 Portable Power Station
Specifications:
- Output Ports: AC (x4), DC, USB (x4), Type-C (x2)
- Input Ports: AC Input, DC Input, Solar Charging Input
- Battery Info: Solid lithium-ion battery
- Cell Chemistry: Pure sine wave
- Cycle Life: The remaining capacity is still above 80% after 1500 cycles
- Protection Type: High-temperature protection, low-temperature protection, over-discharge protection, over-charge protection, overload protection, short-circuit protection, and over-current protection
Product Usage Instructions
Charging:
- Connect the iGo 3600 to an AC power source using the AC Input port.
- You can also charge the device using DC Input or Solar Charging Input depending on availability.
Power Output:
- Use the AC ports to power household appliances within the specified wattage limits.
- The DC and USB ports are suitable for charging electronic devices like smartphones and tablets.
- Type-C ports can be used for compatible devices.
Storage & Maintenance:
- For long-term storage, ensure the battery is charged to around 80% before putting the iGo 3600 into storage.
- Consider using hibernation mode to mitigate battery damage during extended storage periods.
FAQ
Q: How can I ensure optimal battery lifespan?
A: Store the battery with a charge of around 80% for long-term storage and consider using hibernation mode.
Q: What devices are compatible with the Type-C ports?
A: Type-C ports can be used with compatible devices such as laptops, smartphones, and tablets.
Disclaimer
Read all safety tips, warning messages, terms of use, and disclaimers carefully. Refer to the terms of use and disclaimer in User Manual and stickers on the product before use. Users take full responsibility for all usage and operations. Familiarize yourself with the related regulations in your area. You are solely responsible for being aware of all relevant regulations and using Foxtheon products in a compliant way.
Introduction
This product is a portable energy storage power station for home and outdoors, with large capacity, small size, lightweight, high safety, and large output power. It can be quickly split into two small portable power sources for separate use, and the two modules can rotate work to keep the load never powered off. Its multiple outlets can accommodate a variety of small household appliances, and its multiple charging methods can be used. This makes it an essential product for indoor and outdoor use.
Getting Started
Product Details
LCD Screen
How to Charge
AC Input
Use the provided AC charging cable to connect the mains and energy storage AC
input terminals, and the power station will be charged automatically. When the
power station is full, the LCD screen displays 100% power. When fully charged,
disconnect the charging cable.
*20A socket is recommended for AC charging
Reminder: If the device has not been charged for more than 15 days, it is
recommended to press the power button to start the device and then insert the
charging plug to charge it.
Car Charging
Use the provided DC charging cable to connect the vehicle output outlet and the power station ECS input terminal, and the power station will be charged automatically. When the power station is fully charged, the LCD screen displays 100% power. When fully charged, disconnect the charging cable.
*The product can be charged by using the car charging interface on the car. The product supports 12V/24V car charging and the default charging current is BA. It is recommended that the car should be charged in the starting state to avoid car battery loss and failure to start.
Solar Energy Charging
The solar energy transfer cable is used to connect the solar energy outlet and the power station ECS input terminal. The power station will be charged automatically. When the power station is fully charged, the LCD screen displays 100% power. When fully charged, disconnect the charging cable.
*Before connecting the solar panel, ensure that the output voltage of the solar panel is within 12V-40V to avoid damage to the product.
HowtoUse
-
Turn on
Press the power switch to turn on the device. After the device is
turned on, the screen enters the waiting interface. After 6 seconds, the screen enters the display status interface and the power switch indicator stays on. -
Hibernation
The default hibernation time of the product is 15 minutes. If no operation is performed on the product for 15 minutes, the product enters the hibernation state and the shutdown screen is displayed. -
Power off
Press and hold the power switch for 2S, and the screen will display the usage of the power station, and then enter the shutdown interface. -
Function setting interface
-
Press the power switch to start the power station;
-
In the power startup interface, click the AC switch four times (must be in the startup interface state). After entering the startup interface,Continuous click the power switch two times to enter the “Menu” interface;
-
Instructions for battery pack’ s insertion, removal, and installation
-
Press the power switch to start the power station;
-
In the power startup interface,continuous click the power switch two times to enter the “Popup Battery” interface;
3. Press the AC switch to eject the battery.
- ACOutput
Under the startup state, press the AC switch and insert the electrical equipment when the key indicator lights up.
-
Vehicle Output
When the device is powered on, it can be directly inserted into the electrical equipment. -
Type-C / USB Output
When the device is powered on, it can be directly inserted into the electrical equipment. -
Tum on and off the UPS
Turn on the Power and AC switch,hold down the AC switch for 5 seconds to enable the UPS function and the UPS icon is displayed.Hold down the AC switch for 5S or the Power switch for 2S to turn off the UPS.The UPS is shut down by default after it is powered on again.
FAQS
-
What type of battery is used in this product?
This product uses a high-quality solid lithium-ion battery. -
What devices can be equipped at the AC output port of this product?
The AC output port of this product has a rated power of 2500W and a peak power of 2800W. It can power most consumer electronic products.
However, it is recommended that you confirm the power of the electrical appliances before use, and ensure that the total power of all load devices is less than the rated power. -
How do I know how long the product’ s power lasts?
The display screen displays the battery lifetime, which can be used to estimate the charging time required for general devices with stable power usage. -
How do I know that the product is charging?
When charging, the display screen will show the remaining charging time, and the power indicator circle outside the battery capacity percentage will rotate cyclically and indicate the input power. -
How do I clean this product?
Wipe this product with a dry, soft, and clean cloth or tissue. -
How do I store the product?
When storing this product, please turn the product off and then store it in a dry and ventilated place at room temperature. Do not store this product near water. When this product is stored for a long period, it is recommended that the battery be discharged to 30% and then charged to 80% every three months to extend the service life of this product. -
Can this product be brought on board a plane?
No. -
Is the actual output capacity consistent with the capacity indicated in the user manual?
The capacity marked in the user manual is the rated capacity of the battery pack. The actual output capacity of the product is lower than the capacity specified in the user manual because there is a certain efficiency loss during the charging and discharging process.
Safety Instructions
- It is strictly prohibited to place this product near heat sources, such as fire or heating furnaces.
- It is strictly prohibited for this product to come into contact with any liquid. Do not immerse this product in water or allow it to get wet. Do not use this product in the rain, damp conditions, or wet environments.
- Using this product in strong static or strong magnetic field environments is prohibited.
- It is prohibited to disassemble this product in any way or puncture this product with sharp objects.
- It is prohibited to use wires or other metal objects to cause this product to short-circuit.
- Do not use unofficial components or accessories. If replacements are necessary, please visit Foxtheon’ s official sales channel for the relevant purchase information.
- When using this product, please strictly follow the ambient temperature for use in this user manual. Overly high temperatures may cause the battery to catch fire or even explode; while overly low temperatures will seriously degrade product performance to the point that it can no longer meet normal use requirements.
- It is prohibited to stack heavy objects on this product.
- It is prohibited to block the fan during use, or keep the product in unventilated or dusty spaces.
- Please avoid impacts, falling, dropping, or strong vibrations. In the case of severe external impact, please turn off the power immediately and stop using the product. Please keep the product properly secured during transport to avoid vibration and impact.
- If the product accidentally falls into the water during use, place it in a safe open area, and keep away from the product until it has completely dried. Once dried, the product should not be re-used, and should be properly disposed of according to the method described in Section 2.2 “Disposal.” If the product catches fire, please use a fire extinguisher or fire-fighting equipment in the following recommended order: water or mist, sand, fire blanket, dry powder, and carbon dioxide fire extinguisher.
- If the interface of this product becomes dirty, wipe it off with a dry cloth.
- Handle this product with care to prevent it from being damaged due to overturning. If the product is overturned and seriously damaged, immediately turn off the power and place the battery in an open area, being sure to keep it away from combustible materials and people; and dispose of it following the requirements of local laws and regulations.
- Keep this product out of reach of children and pets.
- When conditions permit, be sure to fully discharge the battery of this product before placing the product in a designated battery recycling box. This product contains a battery, which is a hazardous chemical and is strictly prohibited from being placed in an ordinary garbage can. For relevant details, please comply with the local laws and regulations regarding battery recycling and disposal.
- If the battery cannot be fully discharged due to the fault of the product itself, do not dispose of the battery in a battery recycling box directly. Contact a specialized battery recycling company for further disposal.
- An over-discharged battery cannot be started. Please dispose of it as waste.
Specifications
Storage & Maintenance
- Ideally, use and store the product between 20°C(68° F) to 30°C(86° F), and always keep it away from water, intense heat, and sharp objects. Do not store in temperatures above 45° C(l13° F) or below -10°c (14° F) for an extended period.
- Storing a battery with a low charge for a long period shortens its lifespan.lGo 3600 mitigates the damage by putting the battery into hibernation mode. To get the most out of the battery, make sure it is about 80% before putting the iGo 3600 into long-term storage, and then once every three months, discharge the battery to 30% and recharge it backto80%.
Abnormal indication and handling
code | specification | Recovery methods |
---|---|---|
EOOl | Battery A overcharge |
protection
| Pause charging and wait for
automatic recovery
E002| Battery A over-discharge
protection
| Pause the discharge and plug in the charging plug-in time to charge
E003| Battery A overcurrent
protection
| Pause the discharge and wait for
automatic recovery
E004| Battery A overcurrent
protection
| Pause charging and wait for
automatic recovery
EOOS| Battery A discharge overtemperature
protection
| Pause the discharge and wait for automatic recovery
E006| Battery A charging over temperature
protection
| Pause charging and wait for automatic recovery
E007| Battery A SOC
protection
| Pause the discharge and wait for
automatic recovery
---|---|---
E008| Battery B overcharge
protection
| Pause charging and wait for
automatic recovery
E009| Battery B over-discharge
protection
| Pause the discharge and plug in the charging plug-in time to charge
EOlO| Battery B overcurrent
protection
| Pause the discharge and wait for
automatic recovery
E011| Battery B overcurrent
protection
| Pause charging and wait for
automatic recovery
E012| Battery B discharge
overtemperatu re protection
| Pause the discharge and wait for automatic recovery
E013| Battery B charging overtemperatu re
protection
| Pause charging and wait for automatic recovery
E014| Battery B SOC
protection
| Pause the discharge and wait for
automatic recovery
EOlS
| Inverter input short
circuit protection
| Pause use, remove the load and
charging plug, and restart the
| | machine; If the fault cannot be removed, contact the manufacturer’ s
after-sales service;
---|---|---
E016
| Inverter input
overload protection
| Pause the use and wait for automatic
recovery to reduce the power
E017
| Inverter input
Undervoltage protection
| Pause the use and plug in the charging plug-in time to charge
E018
| Inverter input overvoltage
protection
| Pause for automatic recovery
E019
| Inverter input
overtemperature protection
| Pause for automatic recovery
E020
| ****
LV hardware failure
| Pause use, remove the load and charging plug, and restart the machine; If the fault cannot be removed, contact the manufacturer’ s
after-sales service;
E021
| ****
HC hardware failure
| Pause use, remove the load and
charging plug, and restart the
| | machine; If the fault cannot be removed, contact the manufacturer’ s
after-sales service;
---|---|---
E016
| Inverter input
overload protection
| Pause the use and wait for automatic
recovery to reduce the power
E017
| Inverter input
Undervoltage protection
| Pause the use and plug in the charging plug-in time to charge
E018
| Inverter input overvoltage
protection
| Pause for automatic recovery
E019
| Inverter input
overtemperature protection
| Pause for automatic recovery
E020
| ****
LV hardware failure
| Pause use, remove the load and charging plug, and restart the machine; If the fault cannot be removed, contact the manufacturer’ s
after-sales service;
E021
| ****
HC hardware failure
| Pause use, remove the load and
charging plug, and restart the
E027| Inverter DC undervoltage
protection
| Pause for automatic recovery
---|---|---
E028| Inverter output zero crossing fault| Pause use, remove the load and
charging plug, and restart the machine; If the fault cannot be removed,
contact the manufacturer’ s
after-sales service;
E029| Inverter output overtemperature
protection
| Pause for automatic recovery
E030| Inverter output
overvoltage
| Pause for automatic recovery
E031
| ****
Failure of the inverter parameter configuration
| Pause use, remove the load and charging plug, and restart the machine; If the fault cannot be removed, contact the manufacturer’ s
after-sales service;
E032
| DC input voltage is abnormal. Procedure| Pause use, remove the load and charging plug, and restart the
machine; If the fault cannot be
E027| Inverter DC undervoltage
protection
| Pause for automatic recovery
---|---|---
E028| Inverter output zero crossing fault| Pause use, remove the load and
charging plug, and restart the machine; If the fault cannot be removed,
contact the manufacturer’ s
after-sales service;
E029| Inverter output overtemperature
protection
| Pause for automatic recovery
E030| Inverter output
overvoltage
| Pause for automatic recovery
E031
| ****
Failure of the inverter parameter configuration
| Pause use, remove the load and charging plug, and restart the machine; If the fault cannot be removed, contact the manufacturer’ s
after-sales service;
E032
| DC input voltage is abnormal. Procedure| Pause use, remove the load and charging plug, and restart the
machine; If the fault cannot be
after-sales service; |
---|
E037
|
Abnormal MOS tube of battery A
| Pause use, remove the load and charging plug, and restart the machine; If the fault cannot be removed, contact the manufacturer’ s
after-sales service;
E038
|
Abnormal MOS tube of battery B
| Pause use, remove the load and charging plug, and restart the machine; If the fault cannot be removed, contact the manufacturer’ s
after-sales service;
WOO!
|
Low Battery Warning
| The battery is low. You are advised to
charge it right away
W002
| Battery temperature
alarm (charge 60°C discharge 65°()
| High battery temperature
W003
| Inverter 1615
temperature alarm (120°()
| The internal inverter temperature is
high. You are advised to reduce the power
W004
| Inverter 8026
temperature alarm
| The internal inverter temperature is
high. You are advised to reduce the
(80°C) | power |
---|
woos
| Full bridge (aluminum
cylinder) temperature alarm (100°C)
| The internal inverter temperature is
high. You are advised to reduce the power
What’s In the Box
- Outdoor portable energy storage power station host
- Two battery modules
- AC 100-120V /lSA power cable
- Vehicle charging cable
- Vehicle recharge cable
- Vehicle socket output cable