Zekkip 6502QL Half Face Respirator Instruction Manual
- June 17, 2024
- Zekkip
Table of Contents
Zekkip 6502QL Half Face Respirator
Specifications
- Model: 6502QL Half Face Respirator
- Filter Type: 2097 Filter
- Usage: Protection against various particles and pollutants
Product Usage Instructions
Assembly Instructions
Before use, read and understand the User Instructions provided.
Use Instructions
- Follow instructions and restrictions during use to maintain efficacy and prevent sickness or death.
- Conduct/receive training on proper use before using the respirator.
- If you sense contaminants or experience dizziness, leave the area immediately.
- Store the respirator away from contaminated areas when not in use.
Use Limitations
- Do not use in atmospheres with less than 19.5% oxygen as the respirator does not supply oxygen.
- Do not use if the type or concentration of pollutants exceeds the respirator’s protection range.
- Avoid altering, abusing, or misusing the respirator.
Warm Tips
- The respirator itself has no smell, but some users may be sensitive. Clean the facepiece to eliminate odors.
- Align and install the cartridges or filters correctly as instructed.
Cleaning
- Remove cartridges and filters before cleaning.
- Clean the facepiece by immersing in a warm cleaning solution (<120’F) and scrubbing with a soft brush.
- Rinse in fresh warm water and air dry in a non-contaminated area.
- Store the cleaned respirator away from contaminated areas when not in use.
FAQ
-
Q: How often should I clean my respirator?
A: Clean your respirator after each use or when it becomes visibly dirty to maintain its effectiveness. -
Q: Can I use this respirator in oxygen-deficient environments?
A: No, do not use this respirator in atmospheres containing less than 19.5% oxygen as it does not supply oxygen. -
Q: How do I know when to replace the filters?
A: Replace the filters when breathing becomes difficult or when they are visibly soiled or damaged.
Assembly Instructions
- Align the cartridge or filter notch with the facepiece mark.
- Turn the cartridge or filter 1/4 and turn clockwise to stop. To remove the cartridge, turn 1/4 turn counterclockwise.
- Repeat with a second cartridge or filter.
Tightness Test
- Put the headband rack on the back of the head, pull back the buckle of the elastic band, and make the respirator buckle the mouth, nose, and chin.
- Pull the lower elastic band to the back of the neck, tighten the fasteners, and adjust the length of the elastic band to make the face comfortable.
- Breathe vigorously, check the leakage between the respirator and the face, and adjust to the ideal state.
- If the sealing state is not ideal, do not enter the contaminated area, and readjust or replace the respirator.
2097 Filter: Effectively filter all kinds of particles: dust, asbestos, welding smoke, metal salt, oily particles, and radioactive particles.
Important
Before use, the wearer must read and understand these User Instructions.
Use Instructions
- Instructions and restrictions shall be followed during use. Improper use may affect the efficacy of respirators and may result in sickness or death.
- Training on proper use of the respirator should be conducted/received before use
- Leave the contaminated area immediately if you smell or taste contaminants or it dizziness, suffocated, or other distress occurs.
- Store respirators away from contaminated areas when not in use.
Use Limitations
- This respirator does not supply oxygen. Do not use in atmospheres containing less than 19.5% oxygen.
- If the type or concentration of pollutants is unknown, or the type or concentration of pollutants exceeds the protection object or concentration range of this respirator, this respirator is not allowed to be used.
- Do not alter, abuse or misuse this respirator.
Warm Tips
- The respirator itself has no smell. Some customers may be more sensitive to smell. You can clean the facepiece (excluding filters and cartridges) to eliminate odors or place it in a ventilated place to release the peculiar smell.
Cleaning
- Remove cartridges and/or filters.
- Clean facepiece (excluding filters and cartridges). By immersing in a warm cleaning solution, the water temperature is not to exceed 120’F. and serum with a soft brush until clean.
- Rinse in fresh. warm water and air dry in a non-contaminated atmosphere.
- The cleaned respirator should be stored away from contaminated areas when not in use.
Attention
- The cartridge or filter should be changed regularly according to the operating environment.
- The respirator should be cleaned and maintained regularly.
- Check before using each time to ensure its function is intact. If it is damaged, it should be discarded immediately.
- The respirator should be kept in a ventilated and cool place to avoid the environment of high temperature, sunlight, high humidity, and ultra-low temperature.
- The filter shall be kept in a sealed package, and the validity period of the filter in an unopened state is 5 years.