LED s light Universal Dimmer LED Lamps Instruction Manual

June 4, 2024
LED s light

LED s light Universal Dimmer LED Lamps

LED s light Universal Dimmer LED Lamps fig \(2\)

Important!

  • It is dangerous if people without proper training work electrical installation.
  • These should only be carried out by a qualified electrician.
  • This dimmer must be protected on the installation side with a circuit breaker that complies with the regulations.

Warning: electrocution hazard

  • There may be a dangerous voltage at the output of the dimmer!
  • When working on the wiring always switch off the mains voltage. Failure to observe this warning may result in death or serious injury.

Note:

  • Operating at elevated temperatures or voltages may activate thermal protection.
  • In this case reduce the connected load to avoid this again.

Thermal overload protection

  • lintegrated thermal protection circuit. At a dimmer internal temperature of 110° c
  • The over-temperature protection is triggered and remains activated until the temperature reaches approximately 75° C has dropped. If this happens more often, please reduce the load.

Short circuit protection

As soon as it is activated, the dimmer will interrupt the operation. After about 5 seconds, the dimmer is reactivated. If a fault is still detected afterwards, the dimmer interrupts the operation until you switch it off by switching it off and switching it back to normal operation. In case of failure, have the installation checked by an electrician.

Properties

  • Suitable for ON / OFF or AC switching
  • Minimum load 3-5 W with capacitive or resistive load such as dimmable LED lighting, incandescent lamps, high-voltage halogen and low-voltage halogen lamps with electronic transformer.
  • Soft-start operation to extend the life of the lamps.
  • User setting for the lower brightness value.
  • Built-in short-circuit protection, which ensures that the dimmer is protected even in the event of a wiring error or fault
  • Built-in thermal cut-out to protect the dimmer at high operating temperature caused by overload.
  • Meets CE and international safety standards.

Electrical specifications

LED s light Universal Dimmer LED Lamps fig \(3\)

Normal operation

  • Press knob to turn ON/ OFF.
  • Turn the knob to the right to increase the brightness to the maximum value.
  • Turn the knob to the left to reduce the brightness to minimum.

Installation

Wiring details

  1. Disconnect the power supply and secure it against reconnection.
  2. Remove the existing wall switch.
  3. Connect the dimmer according to the wiring diagram.
  4. Mount the cover frame and put the dimmer knob on the shaft.
  5. Turn power back on and test dimmer function.

Note

The dimmer must always be connected to the phase side of the load.
Dimmers MUST NOT be connected in parallel or in series to a load.

Connection plan

LED s light Universal Dimmer LED Lamps fig
\(5\)

  • Problems with dimming? For example: flickering
  • Occasional brightness fluctuations
  • Lamp at lowest dimming level too bright
  • Setting the minimum brightness usually leads to a perfect dimming result.

Setting the minimum

Brightness (A)

  1. Remove the front panel cover, turn on the lamp (full brightnesS)
  2. Press the button Min. brightness set (A)” The lamp is now half bright.
  3. Now adjust the brightness down to the desired level of the basic brightness.
  4. Then again the button ,Min. brightness set (A)”. The lamp now returns to full brightness. The setting has been saved.

Note:
The setting must be made within 10 seconds, otherwise the program WIll be terminated and the setting must be carried out again.

Setting operating mode (B)

  • The setting is made via the rotary knobmode Set (B)” (switch off mains voltage before setting).
  • There are 3 operating modes selectable:
  • TEauto” (factory setting) Trailing edge auto load (i.e. devices and lamps) detection, Applicable for most LED lamps

Attention! A common (simultaneous) operation of loads with leading-edge and loads with trailing-edge is not possibleLED s light Universal Dimmer LED
Lamps fig \(6\)

  • TE” (Trailing Edge Mode) suitable for the operation of Loads that are to be dimmed with Trailing-Edge dimmers.
  • “LE” (Leading Edge Mode) suitable for the operation of loads that are to be dimmed with Leading-Edge dimmers

IMPORTANT NOTE !

When used with wound transformers (magnetic), only the mode “LE” (leading edge) can be usea TEauto” will NOT work in this case! In addition, the basic brightness must be set directly during installation! Non-ob- servance can lead to the defect of the dimmer!

Compatible loadsLED s light Universal Dimmer LED Lamps fig
\(7\)

GB Notes on Disposal

The product is designated for separate collection at an appropriate collection point. Do not dispose of the product with household waste. For more information, contact the retailer or the local authority responsible for waste management.

Care

Before cleaning the unit, disconnect it, if necessary form other components; do not use aggressive cleaning agents. The unit has been carefully checked for defects. If nevertheless you do have cause for complaint, please go back to the retailer where you have bought the product together with your proof of purchase. We are not li-able for damage arising from incorrect handling, improper use or wear or tear. We reserve the right to make technical modifications.

Safety

General Safety

  • Read the manual carefully before use. Keep this manual for future reference.
  • Only use the product for its intended purposes. Do not use the product for other purposes than described in the manual.
  • Do not use this product if any part is damaged or defective. If the product is dam-aged or defective, replace the product immediately.
  • This product shall not be used by children without the supervision of an adult. Children shall not play with the device.
  • Do not modify the product in any way.
    • Do not expose the product to water or moisture. (IP 20)
    • Do not immerge the product into water. (IP 44 – IP 67)
  • Keep the product away from heat sources.
  • Do not block the ventilation openings.
  • Do not look directly into the LED lamp.
  • Keep a minimum distance of 1 meter between the lamp and the surface being illuminated.

Electrical safety

  • To reduce risk of electric shock, this product should only be opened by an author-ized technician when service is required.
  • Do not use the product if the cable or plug is damaged or defective. When dam-aged or defective, it must be replaced by the manufacturer or an authorised repair agent.
  • Before use, always make sure that the voltage is the same as the voltage on the rating plate of the device.
  • Make sure that the cable does not hang over the edge of a worktop and cannot be caught accidentally or tripped over

Warning

  • The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
  • Caution, risk of electric shock.
  • The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire has to be destroyed

Disclaimer

  • Designs and specifications are subject to change without notice. All logos, brands and product names are trademarks or registered trademarks or their respective holders and are hereby recognized as such.
  • Please visit us online on our website: www.temo-elektro.de for more information about our company and our products

Ocumentation

The product has been manufactured and supplied in compliance with all relevant regulations and directives, valid for all member states of the European Union. The product complies with all applicable specifications and regulations in the country of sales.

CE declaration

This product complies with the following directives:

  • LVD: 2014/35/EU
  • EMC: 2014/30/EU
  • RoHS: 2011/65/EU

MV#: 20201209 22:02

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals