Air Oasis AOIA2.0 iAdapt Air 2.0 Replacement Filter Set Owner’s Manual
- June 17, 2024
- Air Oasis
Table of Contents
IAdaptAir 2.0
Owner’’s Manual
AOIA2.0 iAdapt Air 2.0 Replacement Filter Set
Air 2.0 Replacement Filter Set
For use with models AOIA-2S, AOIA-2M, AOIA-2L, and AOIA-2P.
Due to continual improvement the images within the manual may vary from the
actual product.
Before operating this purifier, carefully read the contents of this manual.
Thank you for osing Air Oasis
Congratulations, you own a top-of-the-line air purifier. Before operating this
purifier, please read this manual in its entirety. Doing so will give you
important information to keep you safe from harm and ensure you get the most
benefits from your purifier. For additional information, please contact us:
Mail: Air Oasis, LLC Attn: Customer Service 3401 Airway Blvd.
Amarillo, TX 79118
Web: Www.alroasis.com
Email: support@airoasis.com
Phone: 806-373-7788
Warranty Guaranteed
To view our warranty information, terms and conditions and privacy policy, go
to: www.airoasis.com/policies/#warranty-
policy
Important Safety Instructions
When operating any electrical appliance, basic precautions should always be
followed for safety.
WARNING: To reduce risk of fire, electric shock or injury:
- Carefully read the entire contents of this manual.
- Do not use outdoors or on wet surfaces.
- Do not use the purifier in areas of extreme heat or in the presence of flammable gas
- Do not handle the wires or appliance with wet hands.
- Do not use damaged or uninsulated wires. If appliance is not working properly, call a customer service representative at 806-373-7788.
WARNING: RISK OF ELECTRICAL SHOCK. CAN CAUSE INJURY OR DEATH.
DISCONNECT PURIFIER FROM POWER SUPPLY BEFORE SERVICING.
Store and transport -4°F ~ 180°F, humidity 10% ~ 90% (Non-Condensing).
Do not operate purifier in ambient temperatures above 150° F
- The air purifier must be used upright and on a flat surface
- Do not place the product in direct sunlight.
- This product is not recommended for users with physical, sensory, mental abilities, experience or lack of knowledge.
- To prevent electrical shock, please remove the power plug before maintaining or moving the purifier.
- Please do not clean the appliance with any type of acid-based solutions.
- Do not block the air inlets or outlets.
- Make sure the purifier is used within the voltage of 110-240VAC/50-60Hz.
- It is strictly prohibited to rinse the appliance with water. Do not use the purifier near water sources or volatile flammable items to prevent shock.
- This product is not a toy, hence it is prohibited for children to play with the purifier.
- Do not sit or stand on the purifier. Do not use the purifier when it is shaking or tilting.
- If the purifier is operating abnormally, please unplug the power and contact the manufacturer.
- When cleaning, use a soft, dry cloth to gently wipe the purifier. Use a small soft brush to softly clean the air outlets.
Product Description
- Control Panel
- Top cover
- Sensors
- Electronic board
- Filter
- Main body
- Airinlet
- Airoutlet
- Fan assembly
- Right panel
- Left panel
- Supporting leg
Operation
Control Panel
-
Standby state
After the purifier is plugged in, the power LED lights up and the machine remains in standby state. -
The system is started
In the standby state, press the power button, the purifier beeps and starts.
The control panel lights up and the air quality indicator lights up green. All lights will dim after three minutes of inactivity.
On/Off
By default, the purifier will start in AUTO mode when powered on. The control
panel will display PM2.5, lonizer and UV LEDs on. Additional presses will turn
the lonizers and UV LEDs on/off and power down the purifier.
Timer
Press the Timer button to set the shutdown time. It can be cycled between 1H-
12H.
Once the Timer is set, the button will flash. Once the time is up, the
purifier will power down and enter standby mode.
Fan Speed
Under the startup state, press the fan speed key, the fan speed indicator will
light up, the purifier will beep, and the fan speed will change.
Child Lock
Press the Child Lock button for 3 seconds to lock the control panel and dim
all lights. Hold it down 3 seconds again and the control panel will unlock.
Tap any button while Child Lock is activated to view the purifier’s current
control status.
Toggle
Press the toggle button to check the status of the remaining filter life
(0%-100%), and automatically return to PM2.5 mode 5 seconds later.
Screen Mode
After starting up, the filter will start a cumulative countdown for 4400
hours. When the time is less than 60 hours, the percentage (%) icon will keep
flashing to provide indication.
After replacing the filter, hold down the button for 3 seconds, then the timer
will start over at 4400 hours, and you will hear three beeps.
Auto Mode
When the device is powered on, press the AUTO key. The machine enters
automatic mode, and the fan speed runs according to the state of your air
quality. When the air quality changes from good to bad, the fan and indicator
color change to the corresponding state immediately. When the air quality
changes from bad to better, the color of the indicator will change immediately
and the fan will maintain the original speed for 30 seconds before changing to
the corresponding speed. In automatic mode, the fan speed operates at the
corresponding speed according to the state of air quality (as shown in the
figure below).
Air Quality | PM2.5 indicator light | PM2.5(ug/m3) | Fan Speed |
---|---|---|---|
Air quality is excellent | Green(GOOD) | 0-75 | Speed 1 |
Air quality moderate | Orange(FAIR) | 76-150 | Speed 3 |
Air quality is poor | Red(POOR) | >150 | Speed 4 |
WiFiand Smart App
Hold down the AUTO button until you hear two beeps. The purifier will then be
in pairing mode. Follow the directions in the Air Oasis Home app to complete
pairing.
If the WiFi icon is flashing, the purifier is not connected to WiFi. Once it’s
connected to WiFi the icon will remain on.
For those people sensitive to WiFi or for use in buildings that don’t allow
any telecommunica-tion devices, the WiFi module is removable. Once removed,
the WiFi icon will remain off.
Filter Replacement
- Shut down and disconnect the power supply.
- Remove the top cover by pressing down first and then lifting up.
- Remove the old filters.
- Install new filters.
- Close the top cover.
- The replacement is complete.
Note: Long press the toggle button for 3 seconds to reset the filter replacement reminder.
Correct Placement
In order to work more efficiently, the air inlet/outlet should be kept at
least 4 inches from the wall and other occlusions when in operation.
Attention: Close doors and windows when using the purifier.
Troubleshootin Guide
Purifier Not Turning On
Ensure the following:
- The power button has been pressed.
- The power cord is not loose or broken.
- The correct plug connector is in use.
Odors From the Purifier
Ensure the following:
- There is no debris buildup. Your purifier requires regular filter replacements.
Poor Performance
Ensure the following:
- The purifier is in a space with good air ventilation. Your purifier requires proper air flow to cycle through and clean your air.
- Neither the air inlet nor outlet are obstructed.
Something Else?
If you are experiencing an issue with your air purifier that is not listed
here, please contact our Customer Excellence team.
Specifications
Model | AOIA-2S | AOIA-2M | AOIA-2L | AOIA-2P |
---|---|---|---|---|
Voltage | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC |
Rated Power | 35W | 70W | 105W | 140W |
Frequency | 50-60Hz | 50-60Hz | 50-60Hz | 50-60Hz |
Dimensions | 10.75″ L 10.04″ W 13.50″ H | 10.75″ L 10.04″ W 24.10″ H | 10.75″ L | |
10.04″ W 34.69″ H | 10.75″ L 10.04″ W 45.28″ H | |||
Weight | 7.7 lbs | 13.2 lbs | 22.1 lbs | 28.7 lbs |
CADR | 177 CFM | 353 CFM | 530 CFM | 706 CFM |
Coverage | 265 sq. ft. | 530 sq. ft. | 795 sq. ft. | 1059 sq. ft. |
Noise | 52 dB | 55 dB | 58 dB | 60 dB |
Timer Settings | 1 -12 hrs | 1 -12 hrs | 1 -12 hrs | 1 -12 hrs |
Ozone | 0.0 ppm | 0.0 ppm | 0.0 ppm | 0.0 ppm |
Warranty | 2 Years | 2 Years | 2 Years | 2 Years |
Mail: Air Qasis, LLC
Attn: Customer Service
3401 Airway Blvd.
Amarillo, TX 79118
Web: www.airoasis.com
Email: support@airoasis.com
Phone: 806-373-7788
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>