JB LIGHTING P10 Wash Moving Head Light Instruction Manual

June 17, 2024
JB LIGHTING

JB LIGHTING P10 Wash Moving Head Light

JB-LIGHTING P10 -Wash-Moving -Head-Light-PRODUCT

Specifications

  • Model: P10 Wash
  • Available Models:
    • P10 Wash HP (High Power)
    • P10 Wash HC (High CRI)
    • P10 Wash WW (Warm white)
  • Protection Class: I
  • Protection Rating: IP 20 (Indoor use only)
  • European Community Directives:
    • Low Voltage Directive 2014/35/EU
    • Electromagnetic Compatibility 2014/30/EU

Product Usage Instructions

Safety Instructions
Before operating the P10 Wash, please read and adhere to the following safety instructions:

  • This device is for professional use only.
  • Ensure the fixture is connected to a power outlet with grounding.
  • Disconnect the fixture from mains before removing any covers.
  • Avoid overloading wall outlets and extension cords.
  • Always disconnect the fixture from AC power before cleaning or maintenance.

Operation

  1. Ensure the fixture is connected to a suitable power source as indicated on the specification plate.
  2. Power on the fixture only after verifying the voltage compatibility.
  3. Operate the fixture according to the user manual guidelines for optimal performance.
  4. Ensure adequate ventilation around the fixture during operation.

Maintenance

  1. Regularly clean the fixture using a soft, dry cloth.
  2. Avoid exposing the fixture to liquids or moisture.
  3. Inspect the power cord for any damage and replace if necessary.
  4. Keep the power plug accessible for easy disconnection if needed.

FAQ

Q: Can I use the P10 Wash fixture outdoors?
A: No, the P10 Wash is rated for indoor use only with a protection rating of IP 20.

Q: What should I do if the fixture shows signs of malfunction?
A: If you notice any issues with the fixture, immediately disconnect it from power and contact your authorized distributor for assistance.

 Safety instruction

Introduction

P10 Wash models
The P10 Wash is available in 3 models. The models differ in the light module and partly in the color filters and in the CTC filters.

  • – P10 Wash HP (High Power)
  • – P10 Wash HC (High CRI)
  • – P10 Wash WW (Warm white)

Safety instruction

ATTENTION : For your own safety, please read this safety instructions carefully before you initial start-up.

This device has left our company in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modifi-cation to the device. Please consider that damages caused by manual modifications to the device are not subject to warranty.

ATTENTION : This device is for professional use only! Protection rating IP 20 – only for indoor use!
ATTENTION : JB-Lighting Lichtanlagentechnik GmbH does not authorize or warrant its products for use in life support systems. Life support systems are equipment intended to support or sustain life, and whose failure to perform, when properly used in accordance with instructions provided, can be reasonably expected to result in personal injury or death. This product conforms to the European Community Directives:

  • – Low voltage directive 2014/35/EU
  • – Electromagnetic Compatibility 2014/30/EU

ATTENTION : Disconnect the fixture from mains before you remove any cover of the fixture. With a high voltage you can suffer a dangerous electric shock when touching alive wires and electrical parts under covers!

  • Make sure that the available voltage is not higher than listed on the specification plate of the fixture. This fixture should be operated only from the type of power source indicated on the specification plate. If you are not sure of the type of power supplied, consult your authorized distributor or local power company.
  • Always disconnect the fixture from AC power before cleaning, removing or installing the fuse, or any part.
  • The power plug has to be accessible after installing the fixture. Do not overload wall outlets and extension cords as this can result in fire or elec-tric shock. Do not allow anything to rest on the power cord. Do not locate this fixture where the cord may be damaged by persons walking on it.
  • Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the power cord from time to time.

Refer servicing to a qualified technician!

ATTENTION : This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection.

  • Do not connect this fixture to a dimmer pack.
  • During the initial start-up, some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective. Do not touch the device’s housing bare hands during its operation (housing becomes hot)!
  • For replacement use a fuse of same type and rating only. It’s a SMD fuse soldered on the head board. Refer servicing to qualified technicians!

CAUTION : EYE DAMAGE! Do not look into the light source for an extended period of time. This may be harmful to the eyes. Warning: potentially hazardous radiation – risk group 2 based on DIN EN 62471

  • If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising conden-sation water might damage your device. Leave the device switched off until it has reached room temperature.
  • Do not shake the fixture. Avoid brute force when installing or operating the fixture.
  • This fixture was designed for indoor use only, do not expose this unit to rain or use near water.
  • When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat, moisture or dust.
  • Air vents and slots in the fixture´s head and base are provided for ventilation, to ensure reliable operation of the device and to protect it from overheating.
  • Do not block the front objective lens with any object when the fixture is under operation.
  • The openings should never be covered with cloth or other materials, and never must be blocked.
  • The fixture becomes hot during operation. Allow the fixture to cool approximately 20 minutes prior to manipulate with it.
  • This fixture should not be placed in a built-in installation unless proper ventilation is provided.
  • Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.
  • Always use a secondary safety cable when mounting this fixture.
  • Make sure that the area below the installation place is blocked when rigging, disassembling or servicing the fixture.

ATTENTION : Allow a fixture distance of at least 0,5 metres from easily flammable material and the distance between the light emission and the surface to be illuminated must be at least 2,0 meters.

The maximum ambient temperature 45°C must never be exceeded.

ATTENTION : The lens has to be replaced when it is obviously damaged, so that its function is impaired, e. g. due to cracks or deep scratches!

Operate the device only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the device. Most damages are the result of unprofessional operation! Please use the original packaging or special designed flight cases if the device is to be transported.

ATTENTION : To avoid damage of the internal parts of the fixture head, never let the sunlight lights directly to the front lens, even when the fixture is not working!

Unpacking

This package contains the P10 Wash, two Omega brackets with original Camloc fasteners, powerCON-TRUE1 Schuko cable and a safety note. Open the packaging at the top and remove the powerCON TRUE1 cable, the inlay and the safety instructions. The Omega brackets are located under the spotlight. Check the P10 Wash for possible transport damage. This should be communicated immediately to the transport company.

Rigging the fixture

ATTENTION : Allow a fixture distance of at least 0,5 metres from easily flammable material and the distance between the light emission and the surface to be illuminated must be at least 2,0 meters.

The P10 Wash can either be placed on the floor or hang on a trussing sys-tem. A mounting horizontally to a truss system like in the picture is only allowed if the omega brackets are attached to the outer cam locks. (distance 223.65mm).
When placing the unit on the floor make sure that it stands on rigid ground, because the air inlets in the base must not be covered with anything! To mount the unit on a trussing system use two of the original JB-Lighting omega brackets with original Camloc-connectors. The Camlocs must snap in to be locked properly. Ensure that the structure (truss) to which you are attaching the fixture is secure. If you install the fixture to a truss always attach a safety cable, that can hold at least 10 times the weight of the fixture.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

JB LIGHTING User Manuals

Related Manuals