READ & SAVE THESE INSTRUCTIONS!
CAUTION:

  • To prevent severe shock or electrocution, always turn power OFF at the service panel before working with wiring.

  • Use this device with copper or copper-clad wire.
    Do not use with aluminum wire.

  • Must be installed in accordance with National and Local electrical codes.

  • All cables should be routed away from the outlet openings.

  • Outlets are not intended to support devices or appliances. Do not hang devices by charging cord.

WARNING: IMPROPER WIRING OF ANY ELECTRICAL DEVICE CAN CAUSE SERIOUS INJURY OR DEATH. THESE WIRING DEVICES SHOULD BE INSTALLED BY AN ELECTRICIAN OR OTHER QUALIFIED PERSON.

DESCRIPTION: This device is a Combination Duplex Receptacle and USB-A + USB-C Charger.
The USB ports provide 6A total DC power at 5 volts for charging USB devices. USB ports are for charging purposes only and are not intended for data transfer.

DIRECTIONS:

  1. Disconnect power to circuit by removing fuse or turn circuit breakers OFF before installing. Before wiring verify that power has been removed by testing with a circuit tester at the outlet box.

  2. To replace existing device, remove wall plate and pull device from box.
    If new installation, skip to step 5.

  3. Label wires connected to existing device.

  4. Disconnect existing device.

  5. Strip wires to length of 1 ⁄ 2″ using stripping guide on back of device. Use #10 – #14 AWG solid or stranded wire.

  6. Install device per corresponding wiring diagram. See Figure 1.

  7. Torque terminal screws to 12-14 inch-pounds.

  8. Mount the device to the wall box.

  9. Attach wall plate, then restore power to circuit.