Qolsys IQ-Shock-Mini-S Encrypted Door/Window Sensor Instruction Manual
- June 17, 2024
- Qolsys
Table of Contents
Qolsys IQ-Shock-Mini-S Encrypted Door/Window Sensor
PRODUCT FEATURES
- Reed Switch
- Advanced accelerometer-based shock detection
- 3 distinct sensitivity settings
- LED for easy calibration
- Ultra small form factor
- Easy-to-install batteries
- Supervisory health messaging
TECHNICAL SPECIFICATIONS
- Sensor: 2.5”H x 1”W x .5”D
- Code outputs: tamper, tamper restore, alarm, alarm restore, low battery.
- Transmitter frequency: 319.5 MHz
- Supervisory keep-alive interval: 70 minutes.
- RF Peak field strength: typical 36000 uV/m at 3m
- UL/ULC is listed for residential use only
- Operating Temperature: 0C~49C
- Relative Humidity: 5-93% Non-Condensing
- Storage Temperature: -25-70C
- For use indoors, in dry, ordinary locations only.
- Door frame height: typical 7ft to 8ft (213 to 244 cm)
- Door frame width: typical 1ft to 4ft (30.5 to 122 cm)
- Door frame thickness: 1 1/2″ to 1 3/4″ (3.8 to 4.4 cm)
Battery Life Expectancy
5 years (for typical use) with all sensors enabled. (Not tested by UL/ULC).
Replace the battery with the exact replacement, 3V Panasonic CR2032 Lithium
(x2). Low battery threshold (2.55v). Note: For UL/ULC-certified installations
replace the battery yearly.
MAINTENANCE
CAUTION!
This product uses Lithium Batteries. Improper handling of lithium batteries
may result in HEAT GENERATION, EXPLOSION or FIRE, which may lead to personal
injuries.
WARNING! DANGER OF EXPLOSION IF BATTERIES ARE INSTALLED INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. KEEP AWAY FROM SMALL CHILDREN: IF SWALLOWED PROMPTLY SEE A DOCTOR. Do not try to recharge these batteries.
STEP 1
CHOOSE INSTALLATION LOCATION
- IQ Shock Mini-S can be installed on sliding glass doors, windows, doors that swing and more.
- The enclosure base is secured to the installation surface with double-sided tape, manufactured by 3M, part number 4945,
- UL is recognized under file MH17478 (QOQW2).
UL/ULC NOTE
The IQ Shock Mini-S has been listed by UL/ULC for residential applications
only and under the requirements in the Standards UL 634 and UKLC/ORDC634 for
Door and Window Contact with supplementary
- Shock Sensor. The shock sensor is for supplementary detection only and not for primary protection of the surface and is not intended for use as a glass break detector.
STEP 2
DIP SWITCH CONFIGURATION
Two dip switches allow you to customize the behaviour of this device:
DS#1 – Installer Test Mode
- Calibrates accelerometer orientation.
- LED is Active for dialling in shock sensitivity with a potentiometer.
- Please note, when test mode is enabled (ON) the IQ Shock Mini will NOT transmit signals to the compatible panel.
- This mode is only used for the initial installation and calibration of the shock sensor.
DS#2 – Reed Switch
ON: Enables reed switch (must be ON for UL installations).
OFF:- Disables reed switch
COUNTERCLOCKWISE
- Less Sensitive
IMPORTANT NOTE
The IQ Shock is intended to be installed on doors with or without glass
inserts and on window frames but not on the actual glass surface.
STEP 3
REMOVE BATTERY TABS
STEP 4
APPLY ADHESIVE
STEP 5
MOUNT SENSOR & MAGNET
STEP6
LEARN INTO PANEL
STEP 7
ADJUST SHOCK SENSITIVITY
Adjusting the Shock Sensitivity
IMPORTANT : Calibrate the IQ Shock Mini’s accelerometer from the final mounting position by moving dip switch 1 to ON (enable installer test mode). While in this mode the LED will flash RED when it detects a shock level strong enough to trigger an alarm at the control panel. There are 3 total sensitivity settings and the LED will flash each time the sensitivity threshold is changed. Please note that no RF transmission from the sensor occurs during installer test mode.
Gently hit (using the palm of your hand) the surface on which the device is
installed. Gradually increase the pressure or turn the shock sensitivity
adjustment dial clockwise with a small screwdriver until the desired response
is obtained. Ensure that the device is not triggered by accidental vibration
(e.g., wind, birds, window coverings) hitting the protected window or surface.
Normal traffic or operation of the door/window should not trip the shock
sensor. When testing the sensitivity of the unit, do not cause stress or
damage to the mounting surface or the glass.
WARNING: To avoid personal injury while testing sensitivity, do not apply
pressure to glass inserts or windows. Move dip switch 1 to OFF (disable
installer test mode) once shock sensitivity has been set to the desired level.
Verify that the IQ Shock Mini properly communicates with the Panel.
ADDITIONAL INFORMATION
PLACEMENT TESTING
Before permanently mounting any wireless device, temporarily mount the device
and perform a placement test from the control panel. For detailed placement
instructions refer to the control panel installation manual.
IMPORTANT! Only GOOD or STRONG signal strengths are acceptable. If you
receive a POOR signal from the device, re-locate it and re-test until a GOOD
or STRONG signal is received.
Note: For UL/ULC installations, only STRONG signal levels are acceptable.
After installation verify the product functionality in conjunction with the
compatible panel receiver.
GAP SEPARATION
The recommended maximum gap separation for installation depending on specified
materials and axes of use is 6.25mm (0.25”). See the table below.
Metallic (ferrous) Materials Non-Metallic (non-ferrous) Materials
COMPATIBLE RECEIVERS
For use only with IQ Panel 4, IQ4 Hub, IQ4 NS or IQ Pro variants with compatible SRF 319.5MHz daughter card receiver installed.
Document#: IQSM-IM01
Revision#: 04/27/23
Qolsys Product #: IQSM
FCC ID: 2AAJXQS-IQSKM
IC: 11205A-QSIQSKM
CAN ICES- 3 (B)/NMB- 3(B)
FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>