Purpose
The PZP float probe is designed for use in clean water tanks. It is equipped with electromechanical switches that signal the position of the probe based on which the presence or absence of water can be detected.
Fuctioning
A 3-wire cable is attached to the probe (colours: black, brown, blue). Raising the probe to an angle of +45 degrees (or higher) will close the contact between the black and brown wires. Lowering the probe at an angle of -45 degrees (or lower) will close the contact between the black and blue wires.
Probe positioning| Level detection| Internal contacts
positioning
---|---|---
| High liquid level|
| Low
liquid level|
Wiring diagram
Example of direct pump control
Technical data
voltage | ≤250 V AC |
---|---|
maximum load current (AC-1) | 8 A |
mechanical durability | 50.000 cycles |
electrical durability | 20.000 cycles |
working temperature terminal | ≤80°C |
cable | 3-wire (integrated with probe) |
cable leght | 3 m |
cable diameter | 7,5 mm |
wire cross-section | 1.5 mm² |
dimensions | 142×93×42 mm |
ingress protection | IP68 |
Warranty
F&F products are covered by a 24-month warranty from the date of purchase. The
warranty is only valid with proof of purchase.
Contact your dealer or contact us directly.
F&F Filipowski L.P.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail:
biuro@fif.com.pl
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>