3COM 3C16702A Office Connect Ethernet Hub User Guide
- June 17, 2024
- 3COM
Table of Contents
- 3C16702A Office Connect Ethernet Hub
- Product Information
- Specifications
- Introduction
- Creating Your Network
- Before You Start
- Stacking the Units Together
- Positioning Your OfficeConnect Hub
- Connecting Workstations and Other Equipment to Your Hub
- Connecting OfficeConnect Hubs Together
- Checking Hub Connections
- Q: How many workstations can I connect to the Ethernet Hub
- Q: Can I connect multiple hubs together to expand my
- Q: What type of cables should I use to connect my devices to
- Q: How do I check if my devices are properly connected to the
3C16702A Office Connect Ethernet Hub
Product Information
Specifications
- Model: 3C16702A
- Manufacturer: 3Com Corporation
- Address: 5400 Bayfront Plaza, Santa Clara, California,
95052-8145
Introduction
The OfficeConnect Ethernet Hub 16C is a networking device that
allows you to create a local area network (LAN) in your office or
home. It provides connections for multiple workstations and other
network equipment.
Creating Your Network
Before you start setting up your network, make sure you have the
necessary cables and equipment. The Ethernet Hub 16C has ports on
the front and rear for connecting devices.
Ethernet Hub 16C – Front
The front of the hub contains the Ethernet ports where you can
connect your workstations and other devices.
Ethernet Hub 16C – Rear
The rear of the hub includes additional ports for connecting
multiple hubs together to expand your network.
Before You Start
Prior to setting up your network, it is important to understand
the different connections and how to secure the hub in place.
Workstation Connections
Identify the Ethernet ports on your workstations and connect
them to the corresponding ports on the hub using Ethernet
cables.
Hub Connections
If you have multiple hubs, you can connect them together using
the ports on the rear of each hub. This allows you to expand your
network and connect more devices.
Stacking the Units Together
If you have multiple hubs, you can stack them together to save
space and keep your network organized.
The Rubber Feet
Each hub has rubber feet on the bottom to provide stability and
prevent slipping.
The Stacking Clip
Use the stacking clip provided with the hubs to securely stack
them together. This ensures that the hubs stay in place and
maintain proper connectivity.
Positioning Your OfficeConnect Hub
Choose a suitable location for your hub that is easily
accessible for connecting devices and cables.
Securing the OfficeConnect Hub
You can secure the hub in place using screws or other mounting
options available. This prevents accidental movement or
disconnection of cables.
Connecting Workstations and Other Equipment to Your Hub
Connect your workstations, printers, servers, and other network
equipment to the Ethernet ports on the front of the hub using
Ethernet cables.
Connecting OfficeConnect Hubs Together
If you have multiple hubs, you can connect them together using
the ports on the rear of each hub. This allows you to expand your
network and connect more devices.
Connecting Hubs Using 10BASE-2 (Coaxial)
If you are using 10BASE-2 (coaxial) cables, connect one end of
the cable to the BNC port on one hub and the other end to the BNC
port on another hub. Ensure a secure connection by tightening the
connectors.
Connecting Hubs Using 10BASE-T
If you are using 10BASE-T cables, connect one end of an Ethernet
cable to the RJ-45 port on one hub and the other end to the RJ-45
port on another hub. Ensure a secure connection by pushing the
connectors firmly into place.
Checking Hub Connections
After connecting your devices and hubs, it is important to
perform spot checks to ensure proper connectivity.
Spot Checks
Check the LED indicators on the hubs to verify that each device
is properly connected. The LED indicators will show the status of
the connection.
FAQ
Q: How many workstations can I connect to the Ethernet Hub
16C?
A: The Ethernet Hub 16C has 16 Ethernet ports, allowing you to
connect up to 16 workstations or devices.
Q: Can I connect multiple hubs together to expand my
network?
A: Yes, you can connect multiple hubs together using the ports
on the rear of each hub. This allows you to expand your network and
connect more devices.
Q: What type of cables should I use to connect my devices to
the hub?
A: You should use Ethernet cables (RJ-45) to connect your
devices to the hub. The type of cable depends on your network
setup, either 10BASE-2 (coaxial) or 10BASE-T.
Q: How do I check if my devices are properly connected to the
hub?
A: You can check the LED indicators on the hubs. Each LED
corresponds to a specific port and will indicate the status of the
connection.
OfficeConnect® Ethernet Hub 16C
User Guide (3C16702A)
3Com Corporation 5400 Bayfront Plaza Santa Clara, California 95052-8145
Copyright © 1999, 3Com Technologies. All rights reserved.
No part of this documentation may be reproduced in any form or by any means or
used to make any derivative work (such as translation, transformation, or
adaptation) without written permission from 3Com Technologies.
3Com Technologies reserves the right to revise this documentation and to make
changes in content from time to time without obligation on the part of 3Com
Technologies to provide notification of such revision or change.
3Com Technologies provides this documentation without warranty, term, or
condition of any kind, either implied or expressed, including, but not limited
to, the implied warranties, terms or conditions of merchantability,
satisfactory quality, and fitness for a particular purpose. 3Com may make
improvements or changes in the product(s) and/or the program(s) described in
this documentation at any time.
If there is any software on removable media described in this documentation,
it is furnished under a license agreement included with the product as a
separate document, in the hard copy documentation, or on the removable media
in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to
locate a copy, please contact 3Com and a copy will be provided to you.
UNITED STATES GOVERNMENT LEGEND
If you are a United States government agency, then this documentation and the
software described herein are provided to you subject to the following:
All technical data and computer software are commercial in nature and
developed solely at private expense. Software is delivered as “Commercial
Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a
“commercial item” as defined in FAR 2.101(a) and as such is provided with only
such rights as are provided in 3Com’s standard commercial license for the
Software. Technical data is provided with limited rights only as provided in
DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is
applicable. You agree not to remove or deface any portion of any legend
provided on any licensed program or documentation contained in, or delivered
to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the
United States and may or may not be registered in other countries.
3Com, the 3Com logo and OfficeConnect are registered trademarks of 3Com
Corporation.
Microsoft, MS-DOS, Windows, and Windows NT are registered trademarks of
Microsoft Corporation. Novell and NetWare are registered trademarks of Novell,
Inc.
All other company and product names may be trademarks of the respective
companies with which they are associated.
Year 2000 Compliance: For information on Year 2000 compliance and 3Com
products, visit the 3Com Year 2000 Web page:
http://www.3com.com/products/yr2000.html
Environmental Statement: Please recycle this user guide after use.
Please e-mail any comments about this document to 3Com at:
pddtechpubs_comments@3Com.com. Please include the document title
(OfficeConnect Ethernet Hub 16C), part number (DUA1670-2AAA02) and, if
appropriate, the page number.
Introduction 5
Creating Your Network 6 Ethernet Hub 16C–Front 6 Ethernet Hub 16C–Rear 7
Before You Start 8 Workstation Connections 8 Hub Connections 8
Stacking the Units together 9 The Rubber Feet 9 The Stacking Clip 9
Positioning Your OfficeConnect Hub 10 Securing the OfficeConnect Hub 10
Connecting Workstations and Other Equipment to Your Hub 11 Connecting
OfficeConnect Hubs Together 11
Connecting Hubs Using 10BASE-2 (Coaxial) 12 Connecting Hubs Using 10BASE-T 13
Checking Hub Connections 13 Spot Checks 13
Problem Solving 14
Networking Terminology 16
Dimensions and Standards 17 Dimensions and Operating Conditions 17 Standards
17
Environmental Statements 18 End Of Life Statement 18 Regulated Materials
Statement 18 Environmental Statement about the Documentation 18 Environmental
Statement about the Product Packaging 18
Important Safety Information 19
Wichtige Sicherheitshinweise 20
Consignes importantes de sécurité 21
Technical Support 22 Online Technical Services 22 3Com Knowledgebase Web
Services 22 Support from Your Network Supplier 23 Support from 3Com 23
Returning Products for Repair 26
3Com Corporation Limited Warranty 27
Electromagnetic Compatibility 30
3
4
INTRODUCTION
Welcome to the world of networking with 3Com® . In the modern business
environment, communication and sharing information is crucial. Computer
networks have proved to be one of the fastest modes of communication but,
until recently, only large businesses could afford the networking advantage.
The OfficeConnect® product range from 3Com has changed this, bringing networks
to the small office.
The OfficeConnect Ethernet Hub 16C is ideal for creating small networks. It is
compact and attractively designed for desktop use. This product forms part of
the OfficeConnect range which neatly stack together with the OfficeConnect
stacking clip.
When referring to the OfficeConnect Ethernet Hub 16C, this guide uses the term
`OfficeConnect hub’.
A single OfficeConnect hub allows you to create a small network with up to
sixteen workstations, as shown in Figure 1.
Figure 1 Small Network With OfficeConnect Hub And Optional Print Server
HP JetDirect OfficeConnect print server OfficeConnect hub
If you need to connect more workstations, simply use the stacking clip to
connect another OfficeConnect hub to form a stack (each hub is a single
repeater). The OfficeConnect Ethernet Hub 16C has sixteen 10BASE-T ports and
one 10BASE-2 (Coaxial) connector.
5
CREATING YOUR NETWORK
Ethernet Hub 16C–Front
Alert LED orange Alerts you to excessive network use or an isolated (partitioned) 10BASE-T port.
Power LED green Indicates that the power supply to the hub is present.
Collision LED yellow Flashes each time a collision is detected on the network. Collisions are part of normal network operation.
Port Status LEDs green/yellow Indicates the status of each port. If the LED is green, the link between the port and the next piece of network equipment is OK. If nothing is connected, the LED is off. If yellow, the port has partitioned due to a fault on that segment. The Coaxial port LED can only be yellow or off. It is yellow if the port has partitioned.
Network Utilization LEDs green/yellow/orange Indicates how much your network is being used.
Alert
Power Collision
Port Status 12345678 9 10 11 12 13 14 15 16 COAX
Green = OK, Yellow = Partitioned
Network Utilization 1% 2% 3% 6% 12% 25% 50% 80%
OfficeConnect Ethernet Hub 16C
6
Ethernet Hub 16C–Rear
COAX
8X
1X
Uplink/Normal
16
9X
POWER
10BASE-T
Power Adapter socket Only use the power adapter that is supplied with this OfficeConnect hub. Do not use any other adapter.
Coaxial port Can be used to connect your hub to other OfficeConnect hubs and equipment with 10BASE-2 (Coaxial) cabling.
Uplink/Normal switch Affects the operation of port 16. If you are connecting a hub to the port, set to Uplink (in), otherwise set to Normal (out). See the “Connecting OfficeConnect Hubs Together” section.
Sixteen 10BASE-T RJ-45 ports Use suitable TP cable with RJ-45 connectors. You can connect the OfficeConnect hub to any workstation or OfficeConnect hub that has a 10BASE-T port. See the “Connecting OfficeConnect Hubs Together” section.
7
Before You Start
Your OfficeConnect hub comes with: One power adapter for use with the
OfficeConnect hub. A Product Registration card for you to fill out and return.
Four rubber feet. A stacking clip. Two unit labels and eight cable ties. An
OfficeConnect Network Assistant CD-ROM.
3 One Straight-through’ 10BASE-T cable for every workstation or piece of equipment. A
Straight-through’ cable is one where the pins of one connector
are connected to the same pins of the other connector. 10BASE-T cables can be
shielded or unshielded. We recommend you use shielded. The maximum length you
can use is 100m (328ft).
In order to comply with the 10BASE-T standard, ports designed for workstation
connections have been marked with the graphical symbol `x’. This denotes a
crossover in the port’s internal wiring, for example 1x, 2x, 3x…
The extra parts mentioned in the next section are not supplied with the hub.
Workstation Connections
To connect workstations or other equipment to your hub, you need:
1 10BASE-T connections for all your equipment. 3Com produce a range of easy to install network adapters, which provide your workstations with 10BASE-T connections.
3
2 1
2 An operating system (for example, Netware or Windows 95/98) with network support configured, running on your workstations.
Hub Connections
If you have additional hubs you want to connect using 10BASE-2 (Coaxial), you
need:
One 10BASE-2 50 Ohm cable for each additional hub. The minimum cable length
you can use is 0.5m (1.6 ft). The maximum segment length you can have is 185m
(607ft).
One 10BASE-2 Y’ piece for each hub. You can use
T’ pieces but Y’ pieces provide optimum clearance of the other ports. Two 10BASE-2 50 Ohm terminators (end pieces). If you want to connect additional hubs using 10BASE-T, you need: One
Straight-through’ 10BASE-T cable for each additional hub.
8
Stacking the Units together
The Rubber Feet The four self-adhesive rubber feet prevent your hub from
moving around on your desk. Only stick the feet to the marked areas at each
corner of the underside of your hub if you intend to place the unit directly
on top of the desk. Do not fix the feet if you are going to use the clip.
The Stacking Clip The blue stacking clip allows you to stack your
OfficeConnect units together neatly and securely.
CAUTION: You can stack up to a maximum of four units. Smaller units must be
stacked above larger units.
To fit the clip: 1 Place your unit on a flat surface. 2 Fit the clip across
the top of the unit, as shown in
Figure 2 (picture 1), ensuring that the longer sections of the fastening
pieces are pointing downwards. 3 Align the fastening pieces over the slots
found on each side of the unit. 4 Push the clip down gently to secure it,
ensuring the fastening pieces snap into the slots on the unit.
To fit another unit:
1 Rest the second unit on top of the clip and align it with the front of the
unit below.
2 Press down gently on the unit to secure it onto the clip, ensuring the
fastening pieces fit into the slots on the unit below, as shown in Figure 2
(picture 2).
Figure 2 Stacking Your Units Together
1
Fastening
2
Piece
Fastening Piece
To remove the clip:
1 Remove the top unit together with the clip. If you hook a finger around one
of the the fastening pieces and then pull it gently from out of the slot, the
clip should come away with the upper unit attached to it.
2 Push the clip in the center, so it bends towards the base of the unit, and
then separate once the clip is loose.
9
Positioning Your OfficeConnect Hub
When installing your OfficeConnect hub, ensure:
It is out of direct sunlight and away from sources of heat.
Cabling is away from power lines, fluorescent lighting fixtures, and sources
of electrical noise such as radios, transmitters and broadband amplifiers.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents in the side of the case is not
restricted. We recommend you provide a minimum of 25.4 mm (1in.) clearance.
Securing the OfficeConnect Hub
There are two slots on the underside of the OfficeConnect hub which can be
used for wall mounting. It is recommended that you mount the hubs with the
LEDs facing upwards to prevent dust entering the cooling vents.
When wall mounting the unit, ensure that it is within reach of the power
outlet.
You need two suitable screws. Ensure that the wall you are going to use is
smooth, flat, dry and sturdy. Make two screw holes which are 142mm (5.6in.)
apart. Use the guide at the back of this manual to mark the position of the
holes. Fix the screws into the wall, leaving their heads 3mm (0.12in.) clear
of the wall surface.
Remove any connections to the unit and locate it over the screw heads. When in
line, gently push the unit on to the wall and move it downwards to secure.
When making connections, be careful not to push the unit up and off the wall.
CAUTION: Only wall mount single units, do not wall mount stacked units.
Also available from 3Com, is the OfficeConnect Mounting Unit (part number
3C16765). This allows you to firmly secure a stack of OfficeConnect devices to
the desktop or onto a shelf in a rack.
10
Connecting Workstations and Other Equipment to Your Hub
WARNING: Please read the Important Safety Information’ section before you start. WARNHINWEIS: Bitte lesen Sie den Abschnitt
Wichtige Sicherheitsinformationen’
sorgfältig durch, bevor Sie das Gerät einschalten.
AVERTISSEMENT: Veuillez lire attentivement la section “Consignes importantes
de sécurité” avant de mettre en route.
CAUTION: Do not power the hub off and on quickly. Wait about five seconds
between power cycles.
Connecting workstations and other equipment to your hub is easy. Connect them
using 10BASE-T cables to any of the hub’s sixteen 10BASE-T RJ-45 ports.
10BASE-T cables are very easy to use. To connect a 10BASE-T cable, simply slot
the connector into the relevant RJ-45 port. When the connector is fully in,
its latch locks it into place. To disconnect the cable, push the connector’s
latch in and remove it.
The hub detects all port connections, so you can start using your network
immediately. When you need more ports, simply add more OfficeConnect hubs.
If you are using port 16 to connect to a workstation, ensure the Uplink/Normal
switch is set to Normal (out).
Connecting OfficeConnect Hubs Together
You can increase the number of workstations that can connect to your network
by adding more OfficeConnect hubs. You can use either 10BASE-T or 10BASE-2
(Coaxial) to do this: With 10BASE-2 (Coaxial) you can connect up to 30 hubs
on a single segment, leaving all of the RJ-45 ports free.
With 10BASE-T you can connect up to four hubs in series.
CAUTION: Do not connect the same two hubs together using both 10BASE-T and
10BASE-2 (Coaxial). This causes a network loop.
11
Connecting Hubs Using 10BASE-2 (Coaxial)
When using 10BASE-2 (Coaxial) cable, it is important that both ends of the
segment are properly terminated with 50 Ohm terminators (end pieces).
Only use 50 Ohm 10BASE-2 (Coaxial) cables and use a Y’ piece for each hub. You can use
T’ pieces but Y’ pieces provide optimum clearance of the other ports. Connect a 10BASE-2
Y’ piece to each of your hubs. Daisy-chain each `Y’ piece
with 10BASE-2 (Coaxial) cable to form a single segment (as shown in Figure 3).
Remember to terminate the two free ends of the segment by fitting terminators
(end pieces).
To disconnect a 10BASE-2 (Coaxial) cable, twist each connector counter-
clockwise to unlock it, and remove it.
Figure 3 Correct Hub Connections Using 10BASE-2 (Coaxial)
50 Ohm terminator
POWER
8X
COAX
Uplink/Normal
16
POWER
8X
COAX
Uplink/Normal
16
10BASE-T 10BASE-T
POWER
8X COAX Uplink/Normal
16
10BASE-2 50 Ohm cable. Minimum length is 0.5m (1.6ft)
50 Ohm
10BASE-T
terminator
Maximum segment length is 185m (607ft)
(from terminator to terminator)
12
Connecting Hubs Using 10BASE-T
You can connect hubs together with 10BASE-T in a number of ways, but for
simplicity we recommend the following method:
1 Starting from the bottom, connect port 16 of the lower hub to port 15 of the
hub immediately above. Repeat for each hub (as shown in Figure 4).
2 Set all Uplink/Normal switches to Uplink (in) except for the top hub (the
one with port 16 not connected to another hub). This unused port can be
connected to a workstation provided that the Uplink/Normal switch is set to
Normal (out).
Checking Hub Connections When you have connected your hubs, power them on. The
Port Status LEDs for the ports you have used on the hubs should be green. If
they are not, check your connections and the settings of the Uplink/Normal
switches.
Spot Checks
At frequent intervals, visually check that: The Alert LED is off — this is the
best way to find out if
there are problems with your network.
Case vents are not obstructed.
Cabling is secure and not pulled taut.
Figure 4 Correct Hub Connections Using 10BASE-T
Switch set to Normal (out)
Switch set to Uplink (in)
10BASE-T cable with RJ-45 connectors.
Maximum length is 100m (328ft)
POWER
8X
COAX Uplink/Normal 16
POWER
8X COAX
Uplink/Normal 16
POWER
8X COAX
Uplink/Normal 16
10BASE-T 10BASE-T 10BASE-T
13
PROBLEM SOLVING
The OfficeConnect hub has been designed to aid you when detecting and solving
possible problems with your network. These problems are rarely serious; the
cause is usually a disconnected or damaged cable, or incorrect configuration.
If this section does not solve your problem, contact your supplier for
information on what to do next.
Perform these actions first:
Ensure all equipment is powered on.
Power each unit off, wait about 5 seconds and then power them on.
Check the following symptoms and solutions:
Power LED not lit. Check your power adapter connection. If there is still no
power, you may have a faulty power adapter which needs replacing with another
OfficeConnect power adapter. Do not use any other power adapter with the hub.
Port Status LED yellow for a 10BASE-T port. It is likely that there is a loop
in your network which has caused this port to partition. Examine your
connections and remove the loop. Each piece of equipment needs only one
connection to your OfficeConnect hub. The LED will change from yellow to
green, on receiving a valid packet on the port.
Link between two OfficeConnect hubs not working. Check your hub connections;
follow the information given in the “Connecting OfficeConnect Hubs Together”
on page 11. With 10BASE-T it is likely that an Uplink/Normal switch is
incorrectly set. With 10BASE-2 (Coaxial) it is likely a terminator (end piece)
is not properly fitted; this would cause the Coaxial Port Status LED to light
yellow (partition).
Alert LED continuously lit. There is either continual excessive use of your
network (over 80%) or, more likely, a 10BASE-T port has partitioned due to a
loop in your network (in which case the corresponding Port Status LED will be
yellow). Examine your connections and remove the loop. Each piece of equipment
needs only one connection to your OfficeConnect hub.
Port Status LED not lit for a port that has a connection. There is a problem
with this connection. Check that you are using a `Straight-through’ cable
which is properly connected at both ends, and is not damaged. If the cable is
connected to port 16, ensure that the Uplink/Normal switch is set to Normal
(out). Also check that the equipment being connected to the hub is powered on,
operating correctly and contains the correct type of connection.
14
Refer to Figure 5 below to compare the wiring of a straight-through and a
crossover cable.
Figure 5 Straight-through Cable/Crossover Cable
Normal
port
Pin
1
Rx+
2 Rx-
3 Tx+
4
5
6 Tx-
7
8
Uplink Normal
Pin
port
port
Pin
1
1
Rx-
Rx+
2
2
Rx+
Rx-
3
3
Tx-
Tx+
4
4
5
5
6
Tx+
Tx-
6
7
7
8
8
Normal
Pin
port
1 Rx+
2 Rx-
3 Tx+
4
5
6 Tx-
7
8
15
NETWORKING TERMINOLOGY
A Network is a collection of workstations (for example, IBM-compatible PCs)
and other equipment (for example, printers), connected for the purpose of
exchanging information or sharing resources. Networks vary in size, some are
within a single room, others span continents.
A Local Area Network (LAN) is a network, usually in an office, that spans no
more than a single site.
Ethernet is a type of LAN, referring to the technology used to pass
information around the network. It operates at 10Mbps (megabits per second).
10BASE-T is the name given to the Ethernet protocol that runs over Twisted
Pair (TP) cable at 10Mbps. The OfficeConnect hub uses RJ-45 type connectors
for connecting your TP network
10BASE-2 is the name given to the Ethernet protocol that runs over Coaxial
cable.
A Network Loop occurs when two pieces of network equipment are connected by
more than one path. Your hub detects this and partitions (isolates) one of its
ports to break the loop.
A segment is the length of cable connected to a port, whether this cable is
10BASE-T, 10BASE-2 (Coaxial), or another type. When you daisy-chain equipment
together with 10BASE-2 (Coaxial) cable, via single speed hubs, the entire
cable forms a single segment.
Packets are the units of information your workstations and other equipment
send to each other over the network.
Collisions are a part of normal Ethernet operation and occur if two or more
devices (pieces of network equipment) attempt to transmit at the same time. A
sudden sustained increase in the number of collisions can indicate a problem
with a device, particularly if it is not accompanied by a general increase in
traffic. On coaxial segments an increase in collisions can also indicate
faulty cabling.
16
DIMENSIONS AND STANDARDS
Dimensions and Operating Conditions
18 VA 61 BThU/hr power requirement
0 to 40°C (32 to 105°F) operating temperature
0 to 90% (non-condensing) humidity
228 mm (9.12 in.)
54.6 mm (2.1 in.)
185.4 mm (7.3 in.) + 15.2 mm (0.6 in.) 960 g (2.1 lb) for coaxial port
Standards
Functional:
ISO 8802/3 IEEE 802.3
Safety:
UL 1950, EN 60950 CSA 22.2 #950 IEC 950
EMC:
EN 55022 Class B
EN 50082-1 FCC Part 15 Class B*
ICES-003 Class B VCCI Class B
CNS 13438 Class A
Environmental:
EN 60068 (IEC 68)
Category 5 screened cables must be used to ensure compliance with the Class B requirements of this standard. The use of unscreened cables (category 3 or category 5) complies with the Class A requirements.
*Refer to “Electromagnetic Compatibility” on page 30 for conditions of operation.
17
ENVIRONMENTAL STATEMENTS
It is the policy of 3Com Corporation to be environmentally-friendly in all
operations. To uphold our policy, we are committed to:
Establishing environmental performance standards that comply with national
legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations.
Ensuring that all waste conforms to recognized environmental standards.
Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized environmental
standards.
Improving our environmental record on a continual basis.
End Of Life Statement 3Com processes allow for the recovery, reclamation and
safe disposal of all end-of-life electronic components.
Regulated Materials Statement 3Com products do not contain any hazardous or
ozone-depleting material.
Environmental Statement about the Documentation The documentation for this
product is printed on paper that comes from sustainable, managed forests; it
is fully biodegradable and recyclable, and is completely chlorine-free. The
varnish is environmentally-friendly, and the inks are vegetable-based with a
low heavy-metal content.
Environmental Statement about the Product Packaging The packaging for this
product is fully recyclable. It has a recycled (post consumer) waste content
of at least 40% by weight, and no heavy-metal content.
18
IMPORTANT SAFETY INFORMATION
WARNING: Warnings contain directions that you must follow for your personal
safety. Follow all directions carefully. You must read the following safety
information carefully before you install or remove the unit:
Exceptional care must be taken during installation and removal of the unit.
Only stack the OfficeConnect hub with other OfficeConnect units.
To ensure compliance with international safety standards, only use the power
adapter that is supplied with the unit.
The socket outlet must be near to the unit and easily accessible. You can only
remove power from the unit by disconnecting the power cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions according
to IEC 950. The conditions are only maintained if the equipment to which it is
connected also operates under SELV conditions.
There are no user-replaceable fuses or user-serviceable parts inside the hub.
If you have a physical problem with the unit that cannot be solved with
problem solving actions in this guide, contact your supplier.
Disconnect the power adapter before moving the unit.
WARNING: RJ-45 ports. These are shielded RJ-45 data sockets. They cannot be
used as telephone sockets. Only connect RJ-45 data connectors to these
sockets.
19
WICHTIGE SICHERHEITSHINWEISE
WARNHINWEIS: Warnhinweise enthalten Anweisungen, die Sie zu Ihrer eigenen
Sicherheit befolgen müssen. Alle Anweisungen sind sorgfältig zu befolgen. Sie
müssen die folgenden Sicherheitsinformationen sorgfältig durchlesen, bevor Sie
das Geräts installieren oder ausbauen:
Bei der Installation und beim Ausbau des Geräts ist mit höchster Vorsicht
vorzugehen.
Stapeln Sie das Geräts nur mit anderen OfficeConnect Gerätes zusammen.
Aufgrund von internationalen Sicherheitsnormen darf das Gerät nur mit dem
mitgelieferten Netzadapter verwendet werden.
Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die
Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels
aus der Netzsteckdose unterbrochen werden.
Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 950. Diese Bedingungen sind nur
gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter SELV-
Bedingungen betrieben werden.
Es sind keine von dem Benutzer zu ersetzende oder zu wartende Teile in dem
Gerät vorhanden. Wenn Sie ein Problem mit dem Switch haben, das nicht mittels
der Fehleranalyse in dieser Anleitung behoben werden kann, setzen Sie sich mit
Ihrem Lieferanten in Verbindung.
Vor dem Ausbau des Geräts das Netzadapterkabel herausziehen.
WARNHINWEIS: RJ-45-Anschlüsse. Dies sind abgeschirmte RJ-45-Datenbuchsen. Sie
können nicht als Telefonanschlußbuchsen verwendet werden. An diesen Buchsen
dürfen nur RJ-45-Datenstecker angeschlossen werden.
20
CONSIGNES IMPORTANTES DE SÉCURITÉ
AVERTISSEMENT: Les avertissements présentent des consignes que vous devez
respecter pour garantir votre sécurité personnelle. Vous devez respecter
attentivement toutes les consignes. Nous vous demandons de lire attentivement
les consignes suivantes de sécurité avant d’installer ou de retirer
l’appareil:
Faites très attention lors de l’installation et de la dépose du groupe.
Seulement entasser le moyer avec les autres moyeux OfficeConnects.
Pour garantir le respect des normes internationales de sécurité, utilisez
uniquement l’adaptateur électrique remis avec cet appareil.
La prise secteur doit se trouver à proximité de l’appareil et son accès doit
être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant
son cordon électrique au niveau de cette prise.
L’appareil fonctionne à une tension extrêmement basse de sécurité qui est
conforme à la norme CEI 950. Ces conditions ne sont maintenues que si
l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
Il n’y a pas de parties remplaceables par les utilisateurs ou entretenues par
les utilisateurs à l’intérieur du moyeu. Si vous avez un problème physique
avec le moyeu qui ne peut pas être résolu avec les actions de la résolution
des problèmes dans ce guide, contacter votre fournisseur.
Débranchez l’adaptateur électrique avant de retirer cet appareil.
AVERTISSEMENT: Ports RJ-45. Il s’agit de prises femelles blindées de données
RJ-45. Vous ne pouvez pas les utiliser comme prise de téléphone. Branchez
uniquement des connecteurs de données RJ-45 sur ces prises femelles.
21
TECHNICAL SUPPORT
3Com provides easy access to technical support information through a variety
of services. This section describes these services.
Information contained in this section is correct at time of publication. For
the most recent information, 3Com recommends that you access the 3Com
Corporation World Wide Web site.
Online Technical Services
3Com offers worldwide product support 24 hours a day, 7 days a week, through
the following online systems: World Wide Web site. 3Com Knowledgebase Web
Services.
World Wide Web Site To access the latest networking information on the 3Com
Corporation World Wide Web site, enter this URL into your Internet browser:
http://www.3com.com/
This service provides access to online support information such as technical
documentation and software, as well as support options that range from
technical education to maintenance and professional services.
3Com Knowledgebase Web Services
This interactive tool contains technical product information compiled by 3Com
expert technical engineers around the globe. Located on the World Wide Web at:
http://knowledgebase.3com.com.
This service gives all 3Com customers and partners complementary, round-the-
clock access to technical information on most 3Com products.
22
Support from Your Network Supplier
If you require additional assistance, contact your network supplier. Many
suppliers are authorized 3Com service partners who are qualified to provide a
variety of services, including network planning, installation, hardware
maintenance, application training, and support services.
When you contact your network supplier for assistance, have the following
information ready:
Product model name, part number, and serial number.
A list of system hardware and software, including revision levels.
Diagnostic error messages. Details about recent configuration changes, if
applicable.
If you are unable to contact your network supplier, see the following section
on how to contact 3Com.
Support from 3Com
If you are unable to obtain assistance from the 3Com online technical
resources or from your network supplier, 3Com offers technical telephone
support services. To find out more about your support options, call the 3Com
technical telephone support phone number at the location nearest you.
When you contact 3Com for assistance, have the following information ready:
Product model name, part number, and serial number.
A list of system hardware and software, including revision levels.
Diagnostic error messages.
Details about recent configuration changes, if applicable.
23
Here is a list of worldwide technical telephone support numbers:
Country
Telephone Number
Country
Asia, Pacific Rim Australia Hong Kong India Indonesia Japan Malaysia New Zealand Pakistan Philippines
1 800 678 515 800 933 486 +61 2 9937 5085 001 800 61 009 0031 61 6439 1800 801 777 0800 446 398 +61 2 9937 5085 1235 61 266 2602
P.R. of China
Singapore S. Korea
From anywhere in S. Korea: From Seoul: Taiwan, R.O.C. Thailand
Europe From anywhere in Europe, call: +31 (0)30 6029900 phone
+31 (0)30 6029999 fax
Europe, South Africa, and Middle East From the following countries, you may use the toll-free numbers:
Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy
0800 297468 0800 71429 800 17309 0800 113153 0800 917959 0800 1821502 00800 12813 1800 553117 1800 9453794 1678 79489
Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
Telephone Number
10800 61 00137 or 021 6350 1590 800 6161 463
00798 611 2230 (0)2 3455 6455 0080 611 261 001 800 611 2000
0800 0227788 800 11376 00800 3111206 0800 831416 0800 995014 900 983125 020
795482 0800 55 3072 0800 966197
24
Country
Latin America Argentina Brazil Chile Colombia
North America
Telephone Number
AT&T +800 666 5065 0800 13 3266 1230 020 0645 98012 2127
1 800 876-3266
Country
Mexico Peru Puerto Rico Venezuela
Telephone Number
01 800 CARE (01 800 2273) AT&T +800 666 5065 800 666 5065 AT&T +800 666 5065
25
Returning Products for Repair
Before you send a product directly to 3Com for repair, you must first obtain a
Return Material Authorization (RMA) number. Products sent to 3Com without
authorization numbers will be returned to the sender unopened, at the sender’s
expense.
To obtain an authorization number, call or fax:
Country
Telephone Number Fax Number
Asia, Pacific Rim
+ 65 543 6500
+ 65 543 6348
Europe, South Africa, + 31 30 6029900 and Middle East
+ 31 30 6029999
Latin America
1 408 326 2927
1 408 326 3355
From the following countries, you may call the toll-free numbers; select option 2 and then option 2:
Country
Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy
Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
U.S.A. and Canada
Telephone Number
0800 297468 0800 71429 800 17309 0800 113153 0800 917959 0800 1821502 00800
12813 1800553117 1800 9453794 1678 79489 0800 0227788 800 11376 00800 3111206
0800 831416 0800 995014 900 983125 020 795482 0800 55 3072 0800 966197
1 800 876 3266
Fax Number
1 408 326 7120 (not toll-free)
26
3Com Corporation LIMITED WARRANTY
3Com OfficeConnect Ethernet Hub 16C
The duration of the warranty for the OfficeConnect Ethernet Hub 16C (3C16702A)
is lifetime, including the power adapter.
Advance hardware exchange is available during the first year from your date of
purchase in accordance with 3Com’s standard terms and conditions for such
service. After the first year the warranty reverts to 3Com’s standard lifetime
limited warranty.
To qualify for the lifetime limited warranty and the advance hardware exchange
you must submit the appropriate product warranty registration card to 3Com,
otherwise this product will be warranted for a period of one (1) year without
advance hardware exchange.
HARDWARE
3Com warrants this hardware product to be free from defects in workmanship and
materials, under normal use and service, for the following length of time from
the date of purchase from 3Com or its authorized reseller:
One (1) year (unless otherwise specified above)
3Com’s sole obligation under this express warranty shall be, at 3Com’s option
and expense, to repair the defective product or part, deliver to Customer an
equivalent product or part to replace the defective item, or if neither of the
two foregoing options is reasonably available, 3Com may, in its sole
discretion, refund to Customer the purchase price paid for the defective
product. All products that are replaced will become the property of 3Com.
Replacement products may be new or reconditioned. 3Com warrants any replaced
or repaired product or part for ninety (90) days from shipment, or the
remainder of the initial warranty period, whichever is longer.
SOFTWARE
3Com warrants that each software program licensed from it will perform in
substantial conformance to its program specifications, for a period of ninety
(90) days from the date of purchase from 3Com or its authorized reseller. 3Com
warrants the media containing software against failure during the warranty
period. No updates are provided. 3Com’s sole obligation under this express
warranty shall be, at 3Com’s option and expense, to refund the purchase price
paid by Customer for any defective software product, or to replace any
defective media with software which substantially conforms to applicable 3Com
published
specifications. Customer assumes responsibility for the selection of the
appropriate applications program and associated reference materials. 3Com
makes no warranty or representation that its software products will meet
Customer’s requirements or work in combination with any hardware or
applications software products provided by third parties, that the operation
of the software products will be uninterrupted or error free, or that all
defects in the software products will be corrected. For any third party
products listed in the 3Com software product documentation or specifications
as being compatible, 3Com will make reasonable efforts to provide
compatibility, except where the non-compatibility is caused by a “bug” or
defect in the third party’s product or from use of the software product not in
accordance with 3Com’s published specifications or user manual.
YEAR 2000 WARRANTY
In addition to the Hardware Warranty and Software Warranty stated above, 3Com
warrants that each product sold or licensed to Customer on and after January
1, 1998 that is date sensitive will continue performing properly with regard
to such date data on and after January 1, 2000, provided that all other
products used by Customer in connection or combination with the 3Com product,
including hardware, software, and firmware, accurately exchange date data with
the 3Com product, with the exception of those products identified at 3Com’s
Web site, http://www.3com.com/products/yr2000.html, as not meeting this
standard. If it appears that any product that is stated to meet this standard
does not perform properly with regard to such date data on and after January
1, 2000, and Customer notifies 3Com before the later of April 1, 2000, or
ninety (90) days after purchase of the product from 3Com or its authorized
reseller, 3Com shall, at its option and expense, provide a software update
which would effect the proper performance of such product, repair such
product, deliver to Customer an equivalent product to replace such product, or
if none of the foregoing is feasible, refund to Customer the purchase price
paid for such product.
Any software update or replaced or repaired product will carry a Year 2000
Warranty for ninety (90) days after purchase or until April 1, 2000, whichever
is later.
OBTAINING WARRANTY SERVICE
Customer must contact a 3Com Corporate Service Center or an Authorized 3Com
Service Center within the applicable warranty period to obtain warranty
service authorization. Dated proof of purchase from 3Com or its authorized
reseller may be required. Products returned to 3Com’s Corporate Service Center
must be pre-authorized by 3Com with a Return Material Authorization (RMA)
number
27
marked on the outside of the package, and sent prepaid and packaged
appropriately for safe shipment, and it is recommended that they be insured or
sent by a method that provides for tracking of the package. The repaired or
replaced item will be shipped to Customer, at 3Com’s expense, not later than
thirty (30) days after 3Com receives the defective product.
Dead- or Defective-on-Arrival. In the event a product completely fails to
function or exhibits a defect in materials or workmanship within the first
forty-eight (48) hours of installation but no later than thirty (30) days
after the date of purchase, and this is verified by 3Com, it will be
considered dead- or defective-on-arrival (DOA) and a replacement shall be
provided by advance replacement. The replacement product will normally be
shipped not later than three (3) business days after 3Com’s verification of
the DOA product, but may be delayed due to export or import procedures. When
an advance replacement is provided and Customer fails to return the original
product to 3Com within fifteen (15) days after shipment of the replacement,
3Com will charge Customer for the replacement product, at list price.
3Com shall not be responsible for any software, firmware, information, or
memory data of Customer contained in, stored on, or integrated with any
products returned to 3Com for repair, whether under warranty or not.
ADDITIONAL SERVICES: Telephone Support. This OfficeConnect® product comes with
telephone technical support for ninety (90) days. The ninety (90) day period
begins on the date of Customer’s product purchase.
The telephone technical support is available from 3Com from 9 a.m. to 5 p.m.,
local time, Monday through Friday, excluding local holidays. Telephone
technical support is limited to the 3Com products designated above and may
include assistance with installation, product specific configuration, and
identification of equipment problems. Please refer to the Technical Support
appendix in the User Guide for telephone numbers.
Response to requests for telephone technical support will be in the form of a
return call from a 3Com representative by close of business the following
business day.
To qualify for this 90 days of telephone technical support, you must register
on the 3Com Web site at http://support.3Com.com/index.htm, and provide your
date of purchase, product number, and serial number. 3Com reserves the right
to modify or cancel this telephone support offering at any time, without
advance notice. This offer is not available where prohibited or restricted by
law.
3Com’s Web and Bulletin Board Service are available at no charge, and provide
software and firmware upgrades, a bug list, and technical information about
3Com products.
WARRANTIES EXCLUSIVE
IF A 3COM PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY
FOR BREACH OF THAT WARRANTY SHALL BE REPAIR, REPLACEMENT, OR REFUND OF THE
PURCHASE PRICE PAID, AT 3COM’S OPTION. TO THE FULL EXTENT ALLOWED BY LAW, THE
FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER
WARRANTIES, TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY
OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES, TERMS, OR
CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, SATISFACTORY
QUALITY, CORRESPONDENCE WITH DESCRIPTION, AND NON-INFRINGEMENT, ALL OF WHICH
ARE EXPRESSLY DISCLAIMED. 3COM NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON
TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE,
INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS.
3COM SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION
DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST
OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER
INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO OPEN, REPAIR OR MODIFY THE
PRODUCT, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY
ACCIDENT, FIRE, LIGHTNING, OTHER HAZARDS, OR ACTS OF GOD.
LIMITATION OF LIABILITY
TO THE FULL EXTENT ALLOWED BY LAW, 3COM ALSO EXCLUDES FOR ITSELF AND ITS
SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING
NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE
DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS
OF INFORMATION OR DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN
CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE,
FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF 3COM OR ITS AUTHORIZED
RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS
LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT
3COM’S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED
IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.
28
DISCLAIMER
Some countries, states, or provinces do not allow the exclusion or limitation
of implied warranties or the limitation of incidental or consequential damages
for certain products supplied to consumers, or the limitation of liability for
personal injury, so the above limitations and exclusions may be limited in
their application to you. When the implied warranties are not allowed to be
excluded in their entirety, they will be limited to the duration of the
applicable written warranty. This warranty gives you specific legal rights
which may vary depending on local law.
GOVERNING LAW
This Limited Warranty shall be governed by the laws of the State of
California, U.S.A. excluding its conflicts of laws principles and excluding
the United Nations Convention on Contracts for the International Sale of
Goods. 3Com Corporation 5400 Bayfront Plaza Santa Clara, CA 95054
408-326-5000
29
ELECTROMAGNETIC COMPATIBILITY
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules, and the Canadian
Department of Communications Equipment Standards entitled, “Digital
Apparatus,” ICES-003. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment causes interference to radio or television reception, which
can be determined by turning the equipment off and on, try to correct the
interference by using one or more of the following measures:
Reorient the receiving antenna.
Relocate the equipment with respect to the receiver.
Move the equipment away from the receiver.
Plug the equipment into a different outlet so that equipment and receiver are
on different branch circuits.
Consult the dealer or an experienced radio/television technician for help.
CSA STATEMENT
This Class B digital apparatus meets all requirements of the Canadian
interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du
Règlement sur le matériel brouilleur du Canada.
VCCI STATEMENT
BCIQ STATEMENT
INFORMATION TO THE USER
The user may find the following booklet prepared by the Federal Communications
Commission helpful: How to Identify and Resolve Radio-TV Interference Problems
This booklet is available from the U.S. Government Printing Office,
Washington, DC 20402, Stock No. 004-000-00345-4. In order to meet FCC
emissions limits, this equipment must be used only with cables which comply
with IEEE 802.3.
30
Wall mounting screw hole guide 142mm (5.6in.)
31
Part No. DUA 1670-2AAA02 Published June 1999
32
References
- Networking Products and Services | HPE
- Networking Products and Services | HPE
- Manual-Hub.com – Free PDF manuals!