ZEISS DTC 3-25 Thermal Imaging Clip User Manual

June 17, 2024
Zeiss

ZEISS DTC
3/25 | 3/35 | 4/50

DTC 3-25 Thermal Imaging Clip

ZEISS DTC 3-25 Thermal Imaging Clip

Removal instructions of the accumulator for recycling purposes

Safety instructions:

The device contains a lithium-ion accumulator, therefore appropriate safety measures must be applied:
– Make sure that the accumulator is discharged!
– Do not expose the accumulator to fire or high temperatures above 60°C!
– Do not damage, crush or open the accumulator!
– Do not short-circuit the accumulator and do not expose it to liquids!
– Dismantling and disposal of the accumulator may only be carried out by trained personnel!
– Wear suitable gloves and protective goggles when removing the accumulator!
– Recycle or dispose of the accumulator according to the locally valid regulations!

Steps for removing the accumulator:

  1. To remove the battery, loosen the four Torx screws at the front of the objective.
  2. Disconnect the cables connecting the electronic boards and disconnect the lens section from the rest of the system.
  3. Now loosen the four screws (A) that fix the battery holder in the housing.
  4. Remove the cable (B) of the charging electronics from the upper board.
  5. Pull the battery holder including battery and charging electronics out of the housing.
  6. Remove the charging electronics (3 screws from the top) from the battery compartment and disconnect the connector (C) of the battery from the circuit board.
  7. Push the battery out of the battery compartment from the side.

ZEISS DTC 3-25 Thermal Imaging Clip - parts

Carl Zeiss AG
Carl-Zeiss-Straße 22
D-73447 Oberkochen
www.zeiss.com/nature and www.zeiss.com/hunting

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Zeiss User Manuals

Related Manuals