MONOGRAM ZKR36R 36 Inch Trim Retro Kit Instruction Manual

June 4, 2024
MONOGRAM

MONOGRAM
ZKR36R 36 Inch Trim Retro Kit
Instruction Manual

ZKR36R 36 Inch Trim Retro Kit

Before you begin – Read these instructions completely and carefully.
Note to Installer: Be sure to leave these instructions with the Consumer.
Note to Consumer: Keep these instructions with your Installation Instructions for future reference.

Electrical Shock Hazard.
To avoid the risk of electric shock, make sure the power cord is not plugged into the wall outlet.

Tip Over Hazard. This appliance is top-heavy. Use extreme caution with moving to prevent tipping over which could result in death or serious injury.

The kit provides components to install product(s) in an opening that is 24” deep.

Parts List:

  • Water line jumper (72” only)
  • Water-fitting tee (72” only)
  • 2 power cords (One cord on 36”)
  • RH and LH Case side trims
  • Case top trim
  • 8 Phillips head trim screws

  • 10 Phillips head trim screws

  • 2 Spacer trim side (72” only)
  • Toe Kick (36” only)

Tools and Materials Required:

  • Adjustable wrench
  • 2 Phillips screwdriver

  • 1/4” driver/socket

INSTALL WATER LINE JUMPER/TEE (Only used on dual installation.)

Connect to potable water supply only.

  • Connect the jumper water line from the Trim Retro Kit to the house cold water line. Tighten the compression nut hand tight, then tighten one additional turn with a wrench.  Overtightening can cause leaks!
  • Connect the other end of the jumper water line to the water-fitting tee supplied in the trim retro kit. Tighten the compression nut hand tight, then tighten one additional turn with a wrench. Overtightening can cause leaks!

Installation Instructions

CHANGE POWER CORD
Longer power cords are required for retrofit installation.
Power cords are included in the Retro Trim Kit.
Replace power cords on both units. Both units can be plugged into the same electrical supply receptacle.
Remove the existing short power cord with string assembly:

  • Remove 1/4” hex screws attaching the rear access cover.
    1. Unplug the 3-pin power cord connector inside the machine compartment (press on the sides to release the locking tabs).
    2. Remove the power cord green ground 1/4” hex screw.
    3. Remove strain relief 1/4” hex screw.
    MONOGRAM ZKR36R 36 Inch Trim Retro Kit - fig 1

Install new longer power cord:

  1. Plug in the 3-pin connector (make sure locking tabs are engaged).
  2. Install the power cord green ground screw.
  3. Install the power cord strain relief.

MONOGRAM ZKR36R 36 Inch Trim Retro Kit - fig 2

Electrical Shock Hazard.
To avoid the risk of electric shock, make sure to re-install the ground screw after changing the power cord.

  • Replace the rear access cover. Make sure the power cord and ground wire are properly routed through the access cover cut-out.

Repeat all steps for the second unit.

CASE TRIM INSTALLATION

  • Install the trim kit side rails to the exposed right and left case walls using the provided #8 Phillips head screws – 14 screws per side. Install a spacer on each side of the 72” dual installation.
    MONOGRAM ZKR36R 36 Inch Trim Retro Kit - fig 3

  • Fit the top trim and side trim rails together by sliding the exposed edges of the corner trim into the right and left trim kit side rails. Align and drive the two number 10-24  Phillips head screws into the screw bosses in the side rails to ensure the top trim is snugly fit to the side rails.
    MONOGRAM ZKR36R 36 Inch Trim Retro Kit - fig 4

FOLLOW ALL INSTALLATION INSTRUCTIONS PROVIDED WITH THE APPLIANCE TO COMPLETE THE DUAL INSTALLATION

31-1000538 Rev. 1 05-21 GEA

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MONOGRAM User Manuals

Related Manuals