AVENTICS CAT Cushioning Adjustment Tool Instruction Manual
- June 4, 2024
- AVENTICS
Table of Contents
Operating instructions
About This Document
These instructions contain important information for the safe and appropriate assembly and commissioning of the product.
- Read these instructions carefully, especially chapter 2 “Notes on safety”, before you start working with the product.
Related documents
Also, follow the instructions for all system components.
Observe the system documentation from the system manufacturer.
Please also observe the generally relevant, statutory, and other binding
regulations of European and national legislation and the national regulations
for accident prevention and environmental protection in your country.
Notes on safety
The measuring instrument (CAT) has been manufactured according to the accepted rules of safety and current technology. There is, however, still a danger of personal injury or damage to equipment if the following general safety instructions and the warnings before the steps contained in these instructions are not complied with.
- Read these instructions completely before working with the CAT.
- Keep these instructions in a location where they are accessible to all users at all times.
- Always include the operating instructions when you pass the measuring instrument onto third parties.
Intended use
- The CAT measuring instrument is for commercial use only.
- The CAT measuring instrument is compatible with AVENTICS cylinders of series PRA, CSL-RD, MNI, CCL-IS, ITS, TRB, RPC, and ICS.
- Only use the CAT measuring instrument with AVENTICS actuators with integrated magnets.
- Use within the limits listed in the technical data.
Intended use includes having read and understood these instructions,
especially the chapter “Notes on safety”.
Improper use
It is considered improper use if the CAT measuring instrument
- is used for any application not stated in these instructions or
- is used under operating conditions that deviate from those described in these instructions.
Personnel qualifications
Assembly and commissioning require basic electrical and pneumatic knowledge.
Assembly and commissioning may therefore only be carried out by qualified
electrical or pneumatic personnel or an instructed person under the direction
and supervision of qualified personnel. Qualified personnel is those who can
recognize possible hazards and institute the appropriate safety measures, due
to their professional training, knowledge, and experience, as well as their
understanding of the relevant regulations pertaining to the work to be done.
Qualified personnel must observe the rules relevant to the subject area.
Safety instructions in this document
SIGNAL WORD
Hazard type and source
Consequences
- Precautions
Meaning of the signal word
WARNING
Indicates a hazardous situation that, if not avoided, could result in death or
serious injury.
CAUTION
Indicates a hazardous situation that, if not avoided, could result in minor or
moderate injuries.
NOTICE
Indicates that damage may be inflicted on the product or the environment.
The following must be observed:
General information
- Observe the regulations for safety, accident prevention and environmental protection for the country where the device is used and at the workplace.
- Do not modify or convert the CAT measuring instrument. The manufacturer can accept no liability claims if these instructions are not complied with or the device is interfered with; the warranty for appliances and accessory parts will no longer apply.
- All settings on the CAT measuring instrument, all assembly, and disassembly work, and commissioning may only be performed by trained personnel.
- Do not loosen any connecting cables or tubing if systems are under voltage or pressure!
- Do not place any deflection, torsion, or impact loads on the CAT measuring instrument.
- Only use the CAT measuring instrument within the performance range provided in the technical data.
- The CAT measuring instrument is not a safety component in terms of the Machinery Directive.
On installation
- Only use the included mounting straps for the assembly of the CAT measuring instrument.
- The CAT measuring instrument must be in gapless contact to the cylinder profile.
- Do not install any obviously damaged CAT measuring instruments and exchange defective CAT measuring instruments immediately.
- Ensure that the cylinder is equipped with a magnetic piston.
- Protect the system from being restarted. Hang signs on the main switches that warn workers against switching the system on.
- Avoid ferritic parts in the immediate vicinity of the CAT measuring instrument.
During operation:
- Immediately exchanges the CAT measuring instrument if any malfunctions occur.
- Make sure that permitted core data are not exceeded.
Device Description 1
The CAT measuring instrument is a non-contact measuring instrument and serves
to set the pneumatic cushioning for pneumatic cylinders with an integrated
magnetic piston.
The CAT measuring instrument guides the user through the set-up process and
indicates the current cushioning status as well as the next steps to be
carried out.
In addition, the optional app offers the possibility of displaying additional
information such as the piston speed and cushioning characteristics.
The CAT measuring instrument is customized to AVENTICS cylinders and
compatible with the series PRA, CSL-RD, MNI, CCL-IS, ITS, TRB, RPC, and ICS.
The CAT measuring instrument fulfills the radio installations directive
2014/53/EC.
Delivery Contents
- Transport case
- CAT measuring instrument
- 2 mounting straps
- USB charge cable
- Power pack with operating instructions
- CAT operating instructions
Assembly and Commissioning
WARNING
The danger of injury if assembled under pressure
Injuries and damage to the device or system components may occur if the
pressure is not
switched off before beginning assembly.
- Make sure that the relevant system part is not under pressure before you assemble the product.
**** Due to the magnetic measuring principle, observe the following:
Strong external magnetic fields (e.g. welding devices) or ferromagnetic add-on
parts located in the area of the proximity switch could possibly impair the
CAT measuring instrument function.
Charging the battery1
CAUTION
The danger of injury due to exploding batteries
Unapproved chargers or cables and faulty connection of the charger can lead to
an explosion of the battery or serious damage to the device.
- Only use the supplied chargers (USB charge cable + power pack). See “Delivery Contents”.
- Carefully connect the charger. Make sure that all plugs are properly connected.
NOTICE
Serious damage to the CAT measuring instrument
Open, loose, damaged, or missing covers can lead to water and dust entering
the CAT measuring instrument, which may damage it.
- Ensure that the cover on the micro USB socket (1) is tightly sealed.
- Prevent the cover of the micro USB socket (1) from becoming damaged or detached.
**** Damages due to faulty use are not covered by the warranty.
Charge the battery with the battery charger before you use the CAT measuring
instrument for the first time. You can also charge the CAT measuring
instrument by connecting it to a computer via the USB cable (9, 10).
The LED display (4) indicates the charge level at any time. The battery is
fully charged when the LED display (4) is illuminated green. If the charge
level is less than 20%, the LED (4) flashes red. The empty battery must then
be charged via the micro USB socket (1). The typical charging time is approx.
2.5 hours. The CAT measuring instrument can be used during the charging
process.
- Connect the USB cable (9, 10) to the USB power pack (11).
- Remove the cover of the CAT measuring instrument (1), the USB socket is located behind it.
- Insert the USB cable (8, 9) into the micro USB socket (1).
- Insert the USB power pack (11) into a power socket.
- Fully charge the battery. First, detach the charger from the CAT measuring instrument and then disconnect the charger from the electricity socket.
- Close the cover of the micro USB socket (1).
For energy-saving reasons, the CAT measuring instrument features an automatic
switch-off function that automatically switches off the device after 5 minutes
without
measurement.
Positioning and mounting the CAT measuring instrument on a cylinder, 2/1 2/2
The correct functioning of the CAT measuring instrument requires precise
positioning of the measuring instrument on the cylinder.
- Position the CAT measuring instrument on the cylinder at the point at which the pneumatic cushioning should be adjusted (see a sticker in Fig.).2/1
- Mount the CAT measuring instrument onto the cylinder with one of the included mounting straps (Fig. or). For cylinder diameters larger than 125 mm connect the two2/1 2/2 included mounting straps to each other and mount the CAT measuring instrument on the cylinder.
This prevents displacement of the CAT measuring instrument during the setting process.
** Incorrect mounting of the CAT measuring instrument may result in an
erroneous measurement outcome or failure of the CAT measuring instrument.
Commissioning the CAT measuring instrument1
WARNING**
Risk of uncontrolled actuator movements when the pneumatics are switched on
There is a danger of personal injury if the pneumatic system is in an
undefined state.
- Put the pneumatic system in a defined state before switching it on.
Commissioning may only be carried out by qualified electrical or pneumatic personnel or an instructed person under the direction and supervision of qualified personnel (see also “Personnel qualifications”).
- Switch the CAT measuring instrument on using the switch-on button (2) on the device. The 3 LEDs (cushioning status and throttle adjustment) (5, 6, 7) are illuminated in yellow. The setting process can start now.
- Set the cylinder cushioning as follows:
a) Move the piston into the two-cylinder end positions (calibration drive).
b) Start the first measurement drive. The CAT measuring instrument now shows the cushioning state and the required direction of rotation of the end position throttle.
c) Repeat the setting process of the measuring instrument until the desired state is reached.
-
Please note the various signals of the LED (see display and operation elements).
-
After the device is switched on for the first time or when setting the cushioning for another cylinder series, the calibration drive must be repeated (see description 2a)
under “Commissioning the CAT measuring instrument”). -
In some instances, despite the turning of the end position throttle, the CAT measuring instrument does not signal green but yellow. The reason for this is often an oversized cylinder for the mass and speed or an unstable load on the cylinder. In these cases, the setting can be kept on yellow. To benefit from the advantages of an optimally selected cylinder, a suitable cylinder can be selected for your application with the help of the AVENTICS CylinderFinder.
Display of the operating state1
The operating state of the CAT measuring instrument is displayed by means of
five LEDs.
- If no LED is illuminated, the CAT measuring instrument is not switched on or the battery charge level is at 0%.
- The state of the CAT measuring instrument is displayed by means of lit LEDs (see table below).
LED | Function |
---|---|
Green | Cushioning optimally set |
Yellow | Cushioning can be set |
Red | Cushioning must be set |
Yellow | Cushioning status on the set screw, throttle the movement to the |
left
| Yellow| Cushioning status on the setting screw, throttle the movement to the
right
| Green| Battery charge level = battery full, no charging required
Red, flashing| Battery charge level = battery must be charged
| LED is off| No Bluetooth connection
Blue| Bluetooth connection active
Optional: Create a Bluetooth connection between the CAT measuring
instrument and the mobile end device
The CAT measuring instrument uses Bluetooth radio technology for wireless
connection of the CAT measuring instrument with an app on your smartphone or
tablet. The radio technology does not cause interferences with the measuring
functions of the CAT measuring instrument. The app displays the measurements
on your smartphone or tablet monitor and allows the display at a certain
distance from the CAT measuring instrument within the reach of the Bluetooth
signal.
Requirements
- Android version at least 4.4
- Bluetooth interface at least 4.0
- The Bluetooth function must be activated on your mobile end device (e.g. smartphone) with which you want to establish a connection.
- The end device (e.g. smartphone) must be set to visible for all other Bluetooth devices.
- The GPS (Global Positioning System) must be activated in an Android device.
- The CAT measuring instrument must be switched on.
Downloading and installing the CAT app
The following information can be presented and read out with the help of the
CAT at AVENTICS app:
- Piston speed before reaching the cushioning
- Battery charge level
- Bluetooth connection status
- Path-time diagram in the cushioning area
- LED display for the setting process (for the cushioning state see the display of the operating state)
-
Search for the CAT by AVENTICS app at the “Play Store” or “Apple Store”.
**** The availability of this app may rely on the region or service provider. -
Download the CAT by the AVENTICS app free of charge.
-
Install the app on your mobile end device (e.g. smartphone)
Connect the CAT measuring instrument to the app on your mobile end device
-
Fulfill the requirements under “Optional: Create a Bluetooth connection between the CAT measuring instrument and mobile end device”.
-
Open the installed CAT by the AVENTICS app.
-
Actuating the CONNECT button creates a connection to the “AVENTICS device” (CAT measuring instrument).
**** No other CAT measuring instrument may be in operation within a diameter of approx. 10 m.
No PIN is required.
If a coupling prompt is shown, select cancel. -
The setting process can now be carried out as described under “Commissioning the CAT measuring instrument”.
-
Close the app when it is not in use to save energy.
Other app button functions:
“Bluetooth” button: reset the Bluetooth connection
“Connect” button: reconnect to the “AVENTICS Device” (CAT measuring
instrument).
Care and Maintenance
NOTICE
Damage to the surface caused by solvents and aggressive detergents
The surfaces and seals could be damaged by solvents or aggressive cleaning
agents.
- Never use aggressive solvents or detergents.
The CAT measuring instrument is maintenance-free.
- Regularly inspect the CAT measuring instrument for potential damage.
Disposal
Dispose of the measuring instrument according to the regulations in your country of sending the measuring instrument to AVENTICS GmbH, Ulmer Straße 4, 30880 Laatzen in Germany for disposal.
Declaration of conformity
Search for the current declaration of conformity of the product using the
search mask in the AVENTICS Media Centre at: www.aventics.com/en/media-
centre
Search term: CAT KOE
Technical Data
General data
Measuring ranges | 64 mm |
---|---|
Ambient temperature | —5 … +40 °C (23 … +104 °F) |
Charging temperature | 0 … +45 °C (32 … +113 °F) |
Protection class | IP50 |
Charging speed with the 5 V USB charger | 450 mA / 2.5 h |
Capture speed | 0.2 m/s … 2 m/s |
Operating voltage | 3.7 V DC |
Quiescent current (without load) | 150 mA |
Max. service life with constant operation | 4 h |
Bluetooth ISM band 2.4 … 2.48 GHz TX-Power | 7.5 dBm |
Elastic mounting strap for cylinder diameter | 16 … 125 mm and 125 … 320 mm |
Automatic switch off after | 5 min |
Housing material | Luran S |
Weight | 120 g |
Standards and directives complied with
2014/53/EC | Radio installations directive |
---|
See also the current declaration of conformity of the product at:
www.aventics.com/de/media-centre
Search term: CAT KOE
Figures: View varies according to the series.
Device overview
1 Cover of the micro USB socket
2 On/Off button
3 Status display of the Bluetooth connection
4 Battery charge level display
5 Throttle movement to the left| 6 Cushioning status
7 Throttle movement to the right
8 Micro USB plug
9 USB cable
10 USB plug (for connecting to the PC or power pack)
11 Powerpack
---|---
Assembling the CAT measuring instrument
Assembling the CAT measuring instrument
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of their own judgment and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.
An example configuration is depicted on the title page. The delivered product
may thus vary from that in the illustration.
Translation of the original operating instructions. The original operating
instructions were created in the German language.
R412026160–BAL–001–AD/2018-04 Subject to modifications. © All rights reserved
by AVENTICS GmbH, even and especially in cases of proprietary rights
applications. It may not be reproduced or given to third parties without its
consent.
A VENTICS GmbH
Ulmer Straße 4
30880 Laatzen, GERMANY
Phone +49 (0) 5 11-21 36-0
Fax: +49 (0) 511-21 36-2 69
www.aventics.com
info@aventics.com
Further addresses:
www.aventics.com/contact
Documents / Resources
|
AVENTICS CAT Cushioning Adjustment
Tool
[pdf] Instruction Manual
CAT Cushioning Adjustment Tool, CAT, Cushioning Adjustment Tool, Adjustment
Tool, Tool
---|---
|
AVENTICS CAT Cushioning Adjustment
Tool
[pdf] Instruction Manual
CAT Cushioning Adjustment Tool, CAT, Cushioning Adjustment Tool, Adjustment
Tool, R412026160
|
AVENTICS CAT Cushioning Adjustment
Tool
[pdf] Instruction Manual
CAT Cushioning Adjustment Tool, CAT, Cushioning Adjustment Tool, Adjustment
Tool
References
- AVENTICS – Intelligente, zuverlässige Lösungen für die pneumatische Automatisierung | Emerson DE
- AVENTICS – Intelligente, zuverlässige Lösungen für die pneumatische Automatisierung | Emerson DE
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>