Etac M1048 Flamingo Frame User Manual

May 15, 2024
Etac

Etac M1048 Flamingo Frame

Etac-M1048-Flamingo-Frame-PRODUCT-IMAGE

Product Information

The Flamingo Frame is a user manual for the Flamingo product by Etac Ltd. It provides detailed instructions on how to use the Flamingo frame.

Specifications

  • Product Name : Flamingo Frame
  • Model Number : M1048
  • Revision : 6.0
  • Website : www.etac.com

Product Usage Instructions

  1. Section 1: Introduction
    This section provides an introduction to the Flamingo Frame and its purpose.

  2. Section 2: Safety Precaution
    This section outlines important safety precautions that should be followed while using the Flamingo Frame.

  3. Section 3: Assembly
    This section provides step-by-step instructions on how to assemble the Flamingo Frame.

  4. Section 4: Adjustments
    This section explains how to make adjustments to the Flamingo Frame to ensure proper fit and comfort.

  5. Section 5: Usage
    This section provides detailed instructions on how to use the Flamingo Frame, including how to position the user and adjust the support features.

  6. Section 6: Maintenance
    This section outlines maintenance guidelines for the Flamingo Frame, including cleaning and storage recommendations.

  7. Section 7: Troubleshooting
    This section addresses common issues that may arise while using the Flamingo Frame and provides troubleshooting solutions.

FAQ

  1. Q: How do I adjust the height of the Flamingo Frame?
    A: To adjust the height of the Flamingo Frame, follow these steps:

  2. Step 1: Locate the height adjustment mechanism.

  3. Step 2: Loosen the adjustment knob or lever.

  4. Step 3: Raise or lower the frame to the desired height.

  5. Step 4: Tighten the adjustment knob or lever to secure the frame in place.

  6. Q: How do I clean the Flamingo Frame?
    A: To clean the Flamingo Frame, follow these steps:

  7. Step 1: Use a mild detergent and warm water to wipe down the frame.

  8. Step 2: Rinse with clean water and dry with a soft cloth.

  9. Step 3: Avoid using harsh chemicals or abrasive materials that may damage the frame.

  10. Q: How should I store the Flamingo Frame when not in use?
    A: To store the Flamingo Frame, follow these guidelines:

  11. Step 1: Disassemble any removable parts.

  12. Step 2 : Store the frame in a clean and dry location.

  13. Step 3: Avoid placing heavy objects on top of the frame to prevent damage.

  • Etac Ltd. Unit 60, Hartlebury Trading Estate, Hartlebury, Kidderminster, Worcestershire,
  • DY10 4JB +44 121 561 2222
  • R82 A/S Parallelvej 3 DK-8751 Gedved
  •  +45 796 858 88 R82
  • @etac.com
  • www.etac.com

OVERVIEW

Etac-M1048-Flamingo-Frame-IMAGE-5 Etac-M1048
-Flamingo-Frame-IMAGE-6

ASSEMBLY

Etac-M1048-Flamingo-Frame-IMAGE-11 Etac-M1048
-Flamingo-Frame-IMAGE-13 Etac-M1048
-Flamingo-Frame-IMAGE-15 Etac-M1048
-Flamingo-Frame-IMAGE-18 Etac-M1048
-Flamingo-Frame-IMAGE-19 Etac-M1048
-Flamingo-Frame-IMAGE-20

USAGE INSTRUCTIONS

Etac-M1048-Flamingo-Frame-IMAGE-22 Etac-M1048
-Flamingo-Frame-IMAGE-23 Etac-M1048
-Flamingo-Frame-IMAGE-26

Etac-M1048-Flamingo-Frame-IMAGE-28

Etac-M1048-Flamingo-Frame-IMAGE-29

Warning: This symbol appears in the User Guide along with a number referring to the instructions below. It draws at-tention to situations where the product or the user or career’s safety may be in danger

  1.  Entrapment Hazards
  2. Tilting Hazards
  3. Transportation in motor vehicles
  4. Squeezing Hazard

Consult instructions.
The latest version of all product User Manuals can be downloaded as a “pdf file” from the web page. The manuals can be read with a “Read Out Loud” functionality in e.g Adobe Acrobat and /or printed in a larger size to accommodate persons with visual impairments. The user information is not available in Braille.

  • Incorrect use
  • Ready for use
  • Ready for storage
  • Do not lift the product in the parts that can be raised / lowered
  • Lift only the product in the bottom frame
  • Prohibition: Incorrect lifting points, especially on stairs
  • Prohibition: Do not stand on the foot support or surface
  • Prohibition: No pushing
  • Correct lifting point
  • Emergency stop
  • For indoor and outdoor use
  • For indoor use
  • Inspection
  • Press button
  • Press the button/spring
  •  Listen to click sound
  • Press the pedal or button up
  • Press the pedal or button down
    • Battery charging
    • Battery charged
  • Washing, mild process, maximum 40° C
  • Washing, mild process, maximum 60° C
  • Do not wash
  • Manual cleaning: Keep clean to maintain optimum function
  • Ware washing machine
  • Warewashing machine
  • Foot-operated
  • Refer to the instruction manual
  • NOT intended to be used as a seat in a motor vehicle
  • Conforms to ISO 7176-19, intended to be used as a seat in a motor vehicle

General
We appreciate your choice of a new product from R82 – a worldwide supplier of technical aids and appliances for children and teenagers with special needs. To fully benefit from the options offered by this product please read this User Guide before use and save it for future reference.

  • Intended purpose
    The Flamingo Bath Frame is a toilet/bathing frame with user friendly angle and height adjustment. The Flamingo Bath Frame is designed for Flamingo seats and can be placed over the toilet or used freestanding with a pan. The product is for indoor use in a bathroom environment.

  • Enclosed tools:

    • 5 mm Allen key

Declaration of Conformity

This product conforms to the requirements of the Medical Devices Regulation (2017/745). Further, this product conforms to the requirements according to:

  • EN 12182
  • When using the product outdoors, then the product must be equipped with handbrakes. Handbrakes are optional and accessories for the product. The width of size 4 (700 mm) does not meet the requirement for maximum width of 650 mm for use in private homes. The CE mark must be removed when:
  • Rebuilding the product
  • Using the product outside the intended purpose and declaration of conformity
  • Using other than original R82 spare parts and fittings
  • When combining the device with other products, the combination must not change the intended purpose of the products or modify the products in such a way that compliance with the applicable requirements may be affected. The person / company responsible for the combination of the products must ensure that the applicable requirements are fulfilled. Applicable requirements examples:
  • Material safety (biocompatibility, flammability), mechanical safety (stability, squeezing hazards, inter connection), electrical safety

Disposal

  • When a product reaches the end of its lifetime, it should be separated by material type so that the parts can be recycled or disposed of properly. If required, please contact your local dealer for a precise description of each material. Please contact your local authorities to be informed of the options available for recycling in an environmentally-friendly way.
  • Accessories and spare parts
    • The products from R82 can be supplied with a variety of accessories which comply with the needs of the individual user. Spare parts can be ordered on request. Find the specific accessories on our website or contact your local dealer for further information.
  • R82 Warranty
    • www.etac.com/support
    • Presales information and instructions
    • Presales information and instructions are available at www.etac.com, under your product, in the documents section.

Safety

  • Signs, symbols and instructions placed on this product must never be covered or removed and must remain present and clearly legible throughout the entire lifetime of the product.
  • Immediately replace or repair illegible or damaged signs, symbols and instructions. Contact your local dealer for instructions.
  • Any adverse event in relation to the device must be reported to your local dealer and the national competent authority in a timely manner. The local dealer will forward information to manufacturer.

Caregiver

  • Read the “User Guide” carefully before use and keep it for future reference. Incorrect use of this product may cause serious injury to the user
  • This product contains small parts which could present a choking hazard if removed from their intended placing
  • Always use the correct lifting techniques and aids for this purpose
  • Never leave the user unattended in this product. Ensure permanent supervision by an adult
  • Repair/replacements must only be made using new original R82 spare parts and fittings and carried out in accordance with the guidelines and service intervals prescribed by the supplier
  • If there is any doubt as to the continued safe use of your R82 product or if any parts should fail, stop using the product immediately and contact your local dealer as soon as possible
  • Ensure that moving parts does not squeeze or trap body parts when adjusting them

Environment

  • Observe the surface temperature on the product, before placing an user in it. This goes especially for users with insensitive skin as they cannot feel the heat. If the surface temperature is above 41°C then allow the product to cool before use
  • Use this product on a level surface without any obstacles. Be aware of reduced maneuverability on slippery surfaces
  • When using on inclines, please refer to measurements

User

  • If the user is close to the max. load limit and/or has a lot of involuntary movements, e.g. rocking, a larger size with a higher max. load or a different R82 product should be considered

Product

  • Carry out all positional adjustments on the product and accessories and ensure that all knobs, screws and buckles are securely fastened before use. Keep all tools out of the reach of children
  • Activate the brakes before placing the user into the product
  • Ensure the stability of the product is maintained before placing the user in it
  • We recommend you notify the user before angling the seat and back
  • Ensure the wheels are fully-functional and secure before use
  • Inspect the product and all of its accessories and replace any worn out parts before use

Service & maintenance information

  • Service and maintenance of a medical device is wholly the responsibility of the owner of that device.
  • Failure to service and maintain a device in accordance with the instructions may invalidate the device’s warranty. Furthermore, failure to service and maintain a device may compromise the clinical condition or safety of users and/or their caregivers. Do not perform service and maintenance while the user is in the product. Contact the local dealer for assistance, if needed, in setting up, using or how to perform service and maintenance of the device.
  • Lifetime
    • The lifetime of this product in normal use is 8 years if all maintenance and servicing is carried out in accordance with the manufacturer’s instructions and demonstrably recorded.
  • Reuse
    • This product and its accessories/components are suitable for reuse.
  • Refurbishment for reuse
    • Before reuse or changing the user, follow the service checklist, maintenance and washing instructions and carry out regular inspections.
  • Service interval
    • The frequency of inspection may be altered depending upon use and wear. It is recommended that the product is inspected yearly, every time the product is re-issued for use and after a long-term storage (more than 4 months). The inspection should be carried out by a person who understands the use of the product. Service checklist:
  • Check and adjust the following as per their intended use
    • Product can be folded for storage or transportation
    • Frame is adjustable in height
    • Seat plane is adjustable and can be locked in position
    • Adjustment options for the foot rest, it is possible to lock the angle and fasten the telescopic tubes in position
    • Nuts and bolts on the product are tightened
    • Oil the swing-away parts
    • All labels on the product are intact Repair or replace any damaged or worn out parts.

Maintenance

  • Before every use it is recommended to:
  • Wipe off any residue and dirt from the product, using a cloth with warm water and a mild detergent/soap without chlorine and let it dry before use.
  • Carry out a visual inspection, for any damaged or worn-out parts.

Washing

  • Main product
    • This product can be washed at 60° using a mild detergent for 10 minutes in a washing machine designed for medical devices. Use the machine’s drying function to dry the product.
    • Unmount all accessories and wash them separately.
    • This product can be washed at 85° using a mild detergent for 3 minutes in a washing machine designed for medical devices. Use the machine’s drying function to dry the product.
    • Unmount all accessories and wash them separately.
  • Handwash
    • This product and its accessories can also be washed by hand. Use warm water and a mild detergent/ soap without chlorine and let all parts dry before use.
  • Disinfection
    • The product can be disinfected with a 70% disinfectant IPA solution. It is recommended to wipe off any residue and dirt from the product, using a cloth with warm water and a mild  detergent/soap without chlorine and let it dry before disinfection.
  • Materials
    • Aluminium
    • Plastic
    • Stainless steel
    • Fabric

Surface treatment
The following surface treatment processes were used to protect against corrosion:

  • Lacquered surfaces = Polyester powder coating or ED-coating
  • Non-lacquered aluminium parts = Anodized coating
  • Non-lacquered steel surfaces = Galvanized

Etac-M1048-Flamingo-Frame-IMAGE-62 Etac-M1048
-Flamingo-Frame-IMAGE-62

etac.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals